POWER SUPPLY aps-412_en 06/16

Similar documents
USER MANUAL. 10 January Certification of constancy of performance CNBOP No CPR-0454 Certificate of admittance CNBOP No.

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

User s Manual. Automatic Switch-Mode Battery Charger

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

AWZ 110. AWZ 13,8V/1A/7Ah/LM

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC.

NT1-200, NT1-200/296 Battery Backup. NT1-200 Add-on Battery. Installation Instructions. Specifications. NT1-200, NT1-200/296 Battery Backup

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Uninterruptible Power System

Uninterruptible power supply Supply MEg101.4

Elmdene International Ltd

Installation Instructions

PSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V

Sinewave Inverters. Jazz 700VA and 1000VA. User s manual

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

DIESEL Engine Fire Pump Controllers Features

CX-SERIES ADVANCED BATTERY CHARGER

General Precautions. Personnel Precautions

TRAVEL-PAK BW TRAVEL-PAK INSTRUCTIONS BWL-0375/ Old Road Clacton on Sea Essex CO15 3RH UK

Inverter User Manual

INTIEL THE ELECTRONICS ON YOUR SIDE UNINTERRUPTABLE POWER SUPPLY

Owner s Guide. DC TO AC Power Inverter

GENERALITIES TECHNICAL FEATURES

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

GSL Electronics Modified Sine Wave Power Inverters

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

SCC-MPPT Solar Charge Controller

BRAVER UPS. (Uninterruptible Power System) User s Manual

SMP3CTX Series Power Supply/Charger

Pure Sine Wave Inverter Charger

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

SCC-MPPT Solar Charge Controller

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Solar Charge Controller

Pulsar EXtreme CLA 1500C

KC5 PV Charge Controller Instruction Manual

SCC-MPPT Solar Charge Controller

12 amp RMS Battery Charger

Phoenix Inverter

GLM SERIES CONTROL Users Manual Rev:

R & D SPECIALTIES ROTROL I USER'S MANUAL

Ordering Information. DC Backup Block for S8TS S8T-DCBU-01. DC Backup Block (See note 1.) Bus Line Connector. Basic Block. Battery Holder.

5P 650 AU 5P 650i R 5P 850 AU 5P 850i R 5P 1150 AU 5P 1150i R 5P 1550 AU 5P 1550i R. User's guide

Pulsar EXtreme 2200C / 3200C

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

AL600ULX Series. Power Supply/Charger Installation Guide

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

LEAD ACID BATTERY CHARGER

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

ECONOMISER SERIES E2T USER MANUAL

Sola 3000 Guide Specifications

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

LAN Power Supply Module.

Installation Instructions

GEPA. ARG-24 Series Battery Charger & Battery Group. User Guide

UTILITY INPUT MAINS OUTLET

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Go Power! Manual. GP-SW1500 Inverter. Table of Contents. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Sinewave Inverters. SWING 150VA and 300VA. User s manual

Door Control Panel TS 960. instructions. (Design and functions subject to change) /

Power Distribution System User s Manual. Model: PDS-100

Sinewave Inverter. HIPHOP pro 1500 HIPHOP pro User s manual

EASY CHARGE Weather-resistant fixed mount Battery Charger

Product Installation Document

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

Uninterruptible Power Systems. SDU DC Series

S150,S300 Series Pure Sine Wave Inverter User s Manual

EC400 Power Control System

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

PSU-S-12V/L-1A/5/FTA/PTC-TR-MC AWZ v.1.0

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

DKG-114 MANUAL AND REMOTE START UNIT

AEROSTAT HP-N-Ex Ionising Air Blower

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

Documentation. RM-BV4 Micro DP. Filter control

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

BR133AE BR135AE. Random orbital sanders with dust extraction OPERATING AND MAINTENANCE INSTRUCTIONS

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

EB Conveyor Maintenance Guide

NOVATEK-ELECTRO LTD Research-and-Manufacture Company SINGLE PHASE VOLTAGE MONITORING RELAY RN-113 USERS MANUAL

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

CHARGING UNIT DEM 313

Battery Charger. Series EASY Charger. User s manual

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Transcription:

APS-412 POWER SUPPLY aps-412_en 06/16 The APS-412 switching power supply has been designed for use with 12 V DC electrical devices. It comes with a dedicated connector allowing for integration with Satel's devices. If the power supply is to be used in conjunction with the devices specified below, make sure their firmware version is at least: INT-ADR v. 2.02, INT-E v. 5.01, INT-IORS v. 2.01, INT-O v. 2.01, INT-ORS v. 2.01, INT-PP v. 2.01. The APS-412 power supply meets the requirements of EN50131 Grade 2. 1. Features Output current 4 A. Can be used with an emergency backup battery: battery charge status control, automatic cutoff of discharged battery. DIP switches enabling configuration of the power supply settings. 3 LEDs to indicate the status of: power supply unit, battery, AC mains power supply. 3 OC outputs to indicate the following troubles (in case of the trouble, the output is disconnected from the ground): AC mains power loss, low battery, power supply overload. Audible signaling of troubles. Dedicated connector for Satel's devices. Short-circuit protection of AC mains power supply circuit and battery charging circuit. Short-circuit and overload protection of the power output. Input interference filter. Precision voltage control. Suitable for mounting in OPU-3 P and OPU-4 P / PW enclosures, as well as in distribution switchboards on 35 mm DIN rail.

2 APS-412 SATEL 2. Description of the power supply Explanations for Fig. 1: Fig. 1. APS-412 power supply. F1 slow-blow fuse 3.15 A AC circuit protection. LEDs indicating present status of the power supply: red LED indicating current overload of the power supply: OFF current consumption not exceeding 4 A, blinking current consumption exceeding 4 A. yellow LED indicating the battery status (battery testing mode enabled): ON battery OK (or the battery testing mode disabled), blinking low battery (battery voltage below 11.5 V), OFF no battery or blown F3 fuse (3.15 A). green LED indicating the AC mains power supply status: ON AC power OK, blinking no 230 V AC power or blown F1 fuse (3.15 A). 2.1 Electronics board Description of terminals: L terminal for connecting phase conductor. N terminal for connecting neutral conductor. PE terminal for connecting protective conductor. +12V +12V DC power output. COM common ground. WS OC type output signaling loss of 230 V AC mains voltage. WB OC type output signaling low battery voltage (below 11.5 V). WP OC type output signaling current overload (above 4 A).

SATEL APS-412 3 Fig. 2. Part of power supply PCB visible after removal of cover. Explanations for Fig. 2: socket for connecting cable to devices with dedicated connector. DIP-switches (see section "DIP switches"). battery connector. F3 slow-blow fuse 3.15 A protection of battery charging circuit. 3. DIP switches The switch 6 must be set in OFF position. The switches 1-5 are intended for setting operating parameters of the power supply (see Table 1). By factory default, all of them are set in OFF position. Switch No. 1 2 3 4 5 Description audible trouble signal Enables (ON) / disables (OFF) the audible trouble signal (short beep every 3 seconds). battery test Enables (ON) / disables (OFF) the battery testing mode. Setting the OFF position will also disable the battery trouble indication on the WB output. battery charging current Defines the battery charging current (ON 1 A, OFF 0.5 A). AC power failure reporting delay Defines the time that must elapse after the moment of AC power failure for the WS output to be activated. The delay time shall be set in accordance with Table 2. Table 1. Do not charge the battery with current exceeding 10% of the battery capacity. If the power supply is connected to the dedicated expander connector and the expander has been identified as an expander with power supply, the AC power failure reporting delay set by means of the switches will be disregarded. The delay shall be programmed for the expander.

4 APS-412 SATEL Delay time Switch No. 3 s 60 s 600 s 1800 s 4. Installation 4 OFF ON OFF ON 5 OFF OFF ON ON Table 2. Disconnect power before making any electrical connections. The power supply should be permanently connected to the 230 V AC mains supply. Before you make the cabling, familiarize yourself with the electrical installation of the facility. Select a circuit which is always alive to supply the unit. The power circuit should be protected with a proper safety device. Instruct the owner / user of the power supply how to disconnect the unit from the mains (e.g. indicate the fuse protecting the power circuit). As the emergency power supply source, use a 12 V sealed lead-acid battery. The battery capacity must be appropriately selected to match the current consumption in the system. If the power supply is to be used in an alarm system which is to meet requirements of the EN 50131 standard for Grade 2, the battery should provide 12 hours of system operation in the event of mains power loss. The power supply has been designed for use with lead-acid batteries or other batteries having similar charging characteristics. Using other batteries than the recommended ones may cause an explosion. Do not connect deeply discharged battery to the power supply (with voltage across unloaded terminals below 11,5 V). The battery should be precharged with a proper charger. The used batteries must not be discarded, but should be disposed of in accordance with the existing rules for environment protection. Before proceeding to installation, estimate the current consumption by all devices which are to be supplied from the APS-412 power supply unit. The sum of currents consumed by these devices must not exceed: 3 A, if a battery is connected to the power supply, 4 A, if no battery is connected to the power supply. 1. Remove the screw fixing the cover of power supply terminals.

SATEL APS-412 5 2. Remove the cover of power supply terminals. 3. Configure the power supply using the DIP switches. 4. If the power supply is to be connected to a device provided with dedicated connector, connect the dedicated cable to the connector designated in Fig. 2. 5. Connect cables to the +12V and COM terminals, if they are to be used to supply the external device. 6. You may connect LEDs or relays to the trouble signaling outputs, or connect these outputs to control panel zones. 7. Connect battery cables to the connector designated in Fig. 2. 8. Remove the screws and take out the wire fastening element. 9. Run the cable through the cable grommet. 10. Screw the 230 V AC power leads to the corresponding terminals (phase conductor to L terminal, neutral conductor to N terminal, and protective conductor to PE terminal).

6 APS-412 SATEL 11. Screw the wire fastening element. 12. Replace the cover of power supply terminals. 13. Replace the screw fastening the cover of power supply terminals. 14. Connect the battery to the dedicated leads (positive terminal to RED one, negative terminal to BLACK one). 15. Turn on 230 V AC power. The power supply will signal voltage presence with 1 beep and the LED will go on. If the event of a ground fault of power supply output (due to installation mistake or cable defect) or a short circuit caused by failure of the fuse F3 in the battery circuit, the power supply will turn off. After the problem is cleared, the power supply will turn on automatically. 5. Battery testing by the power supply After starting the power supply, provided that the battery testing mode is enabled and a sufficiently charged battery is connected, the LED should go on after about 10 seconds. The battery is checked every 4 minutes for ten to twenty seconds. Duration of a full test of the battery charge status is up to 12 minutes. If the battery voltage drops below 11.5 V, the power supply will report a trouble on the WB output, and the LED will start blinking (optionally, the trouble may be audibly signaled). When the voltage goes down to 10.5 V, the power supply will disconnect the battery to protect it against full discharge and damage. The LED will go off.

SATEL APS-412 7 6. Specifications Power supply type...a Supply voltage...230 V AC Rated output voltage...12 V DC Output current...4 A Battery failure voltage threshold...11.5 V ±10% Battery cut-off voltage...10.5 V ±10% Battery charging current (selectable)... 0.5 A / 1 A Load-carrying capacity of outputs: WS, WB, WP (OC type)...50 ma Environmental class... II Operating temperature range...-10...+55 C Enclosure dimensions...77 x 122 x 59 mm Weight... 306 g The declaration of conformity may be consulted at www.satel.eu/ce SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. + 48 58 320 94 00 www.satel.eu