INDUSTRIAL GENERATOR SERVICE

Similar documents
Diesel generator set 4BT3.3 series engine

Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL

CLIENT: PROJECT: PO#: ESTIMATOR:

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Diesel generator set QSB7 series engine

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Diesel generator set QSK50 series engine

.3 Section Concrete Forms and Accessories: Installation of Anchor Devices, Setting Templates

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

70 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES: Standby Power Rating Model QT070 (Bisque) - 70 kw 60Hz

Diesel generator set 6BT5.9 series engine

Inspection, Testing, and Maintenance Fire Pumps NFPA 25, Chapter 8 as amended by CCR, Title 19 Page 1 of 8

Diesel generator set QSL9-G7 series engine

Rental Power QSB7 series engine

Spark-ignited generator set

PGDLS352KW 380/ / / / / / / / /

Diesel generator set QSK95 series engine

Diesel generator set QSX15 series engine

PGDLS / / / / / / / / /

Diesel generator set QSX15 series engine

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

of Fire Pump Assemblies

GMP400PX/ Features:

Spark-ignited generator set

Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw

STANDBY GENERATOR 130 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Spark-ignited generator set

STANDBY GENERATOR 100 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Diesel generator set QSK23 series engine

Rental Power 800 kw. Specification sheet. Description. Features. Options

GMP80PX/ Features:

STANDBY GENERATOR 80 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

PGDLS / / / / / / / / /

1P 120/240V, 3600 RPM,

SECTION PACKAGED ENGINE GENERATOR SYSTEMS

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

Power Ratings. Standby SG kva / 240 kw. Prime PG kva / 192 kw

Standby Rated Generators. Standby SG kva / 184 kw. Prime PG kva / 147 kw

Diesel generator set QSK23 series engine

Power Ratings. Standby SG kva / 160 kw. Prime and standby ratings based on 3-Phase voltages. Model number based on kw rating.

22 kva GENERAC STANDBY GENERATORS ISO. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES:

Diesel generator set QSK60 series engine

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GMS800C/ Features:

GENERAC GUARDIAN SERIES STANDBY GENERATORS

Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

SPECIFICATIONS. Stationary Emergency Generator Specifications STATIONARY EMERGENCY GENERATOR COOLING SYSTEM FUEL SYSTEM ENGINE ELECTRICAL SYSTEM

VoltPro VP4 Automatic Voltage Regulator

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Unit 32 Three-Phase Alternators

Rental Power QSL9 series engine

GENERAC GUARDIAN SERIES STANDBY GENERATORS

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

SPECIAL SPECIFICATION 5066 Packaged Engine Generator System

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Model NA 2 L

SPECIAL SPECIFICATION 8334 Packaged Engine Generator

QT025A 2.4L 25 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

Diesel generator set QSK60 series engine

Protector Series ISO FEATURES. Standby Generators Liquid-Cooled Gas Engine INCLUDES:

Diesel Generator Set S3.8 Series Engine

Diesel generator set QSK60 series engine

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

DIESEL GENERATOR SET MTU 16V2000 DS1100

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

INDEX Section Page Number Remarks

Rating Definitions and Conditions

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

STANDBY GENERATOR 25 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 130 kw 163 kva 60 Hz

WPS150/S EP Series. Features:

Model MP150 W W

Diesel Generator set QSK95 series engine

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Diesel Generator set QSK95 series engine

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

EMERGENCY GENERATOR SET

Power Ratings. Standby SG kva / 320 kw. Prime PG kva / 288 kw

Rental Power 1500 kw. Specification sheet. Description. Features. Options

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Rating Definitions and Conditions

Rating Definitions and Conditions

Siemens Liquid Cooled Standby Generators

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

Rental Power KTA50 G3 series engine

Diesel generator set QSK78 series engine

Electric Motor Controls BOMA Pre-Quiz

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

Rating Definitions and Conditions

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Data Center Continuous

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

Transcription:

INDUSTRIAL GENERATOR SERVICE PREVENTATIVE MAINTENANCE PROGRAM Customer: Date: Contact Person: Work Order #: Contact Number: ( ) Technician: INSPECTION COMPONENTS 1. GENERAL Check fuel tank level. Check lubricating oil level. Check engine coolant. Examine engine, generator, fuel tanks and cooling systems for evidence of leakage. Check louver settings and control panel settings (ensure the unit is ready for start-up). Check the engine room ventilation system for proper operation. 2. BATTERIES & CHARGING EQUIPMENT Check electrolyte level. Check electrical connections Check charger for electrical connections, cleanliness and operation. 3. ENGINE Check governor, control linkages and oil level (if applicable. Check fan belts and protection devices. Check crankcase breathers. Check governor. 4.. CONTROL PANEL Check security of panel covers and that the annunciator lamps are operational. Check electrical connections and main circuit breaker switch and breaker operation and clean insulators and bushings. Check voltage regulator operation Comments: Page 1 of 8

SERVICE COMPONENTS 5.* ENGINE Check valve settings Change lube oil and filters Check antifreeze PH level and freeze point. Change fuel filters. Inspect and clean exhaust system. 7*. CONTROL PANEL Isolate the panel, open all inspection covers and tighten all electrical connections. Operate all moving parts to ensure they move freely. Clean contacts as required. Remove all dust. Check gauge operation. 6.* GENERATOR Test surge suppressor and rotating rectifier on brushless machines Replace bearings. Clean rotor and stator windings (compressed air) Check coupling bolts and alignment. Check conduit tightness. Inspect windings at rotor and stator slots. Tighten all electrical connections. Check insulation of generator windings. 8.* TRANSFER SWITCH Isolate transfer switch, open all inspections covers and tighten all electrical connections Operate all moving parts to ensure they move freely. Clean contacts as required. Remove all dust. Clean and lubricate *These items require special skill. It is usually most economical to have this work carried out by a qualified technician. To check the insulation of the generator windings, use an insulation tester (megger). Resistance in megohms should be no less than: rated V + 1000 (If the resistance is less, troubleshoot to determine appropriate action). 1000 Comments: Customer Signature: GPR Technician: Page 2 of 8

Date: GPR Job # Work Order # Customer Name: Contact Name: Phone: Location #: Generator #: GENERATOR REPORT Manufacturer: Model Type Serial # Stator Voltage Amperage KW KVA Phase RPM Age Powerfactor HZ Thermal Class Stator Insulation Ambient Temp Field Volts Field Amps Standby Duty Rating Continuous Duty Rating AVR Manufacturer AVR Model Main Breaker Amps Hour Meter Reading Bearing # NDE Bearing # DE GENERATOR CONTROL PANEL Manufacturer Model Type ENGINE, NAMEPLATE Manufacturer Model Type Serial # Fuel Type Governor Manufacturer Governor Model Horsepower Cooling Type Battery Voltage NAMEPLATE DATA TRANSFER SWITCH/SYNCRONOUS PANEL Manufacturer Model Type Serial # Load Sharing Manufacturer Load Sharing Model Type AMPS Volts HZ Phase BATTERY CHARGER Manufacturer Model Type Volts IN DC Volts Out DC Amps Out VISUAL INSPECTION Inspect Anchorage Grounding Fluid Leaks Control Panel Mounts Muffler System Louvers Building Air Filters Battery NOTES: Page 3 of 8

TRANSFER SWITCH & SYNCRONOUS PANEL CHECKS Volt Meter Scale Applied Volts As Found As Left Amp Meter Scale Applied Amps As Found As Left Watt Meter Scale Applied Watts As Found As Left KVA Meter Scale Applied KVA As Found As Left HZ Meter Scale Applied HZ As Found As Left Power Factor Meter Applied PF As Found As Left Synchroscope Check Operation Volt/Amp Selector Switch Check Operation Synchronizing Lights Check Operation Generator Selector Switch Check Operation Automatic Transfer Test Simulate Loss of Normal Power Operation Test Return to Normal Power Operation Test Simulate Loss of Emergency Power Operation Test Engine Start Sequence Operation Test Time Delay Upon Transfer Operation Test Automatic Transfer Operation Operation Test Engine Cool Down & Shutdown Operation Test Notes: Page 4 of 8

MECHANICAL INSPECTION OF ELECTRICAL EQUIPMENT BATTERY & CHARGER Clean Battery Meter Batter Volts Battery Specific Gravity Check Battery Charger Volt Meter Amps Meter Water Top Up Yes / No Quantity Added Float Voltage Equalize Voltage Verify Alarms Float/Equalizer Switch Position; As Found As Left GENERATOR CONTROL PANELS Volt Meter Scale Applied Volts Found As As Left Amp Meter Scale Applied Amps Found As As Left Current Transform Ration Frequency Scale Applied HZ Found As As Left Hour Meter; As Found As Left Check Operation Panel & Alarm Lights Check Operation Low Oil Pressure Alarm/Shutdown Check Operation Low Oil Level Alarm/Shutdown Check Operation High Oil Temp Alarm/Shutdown Check Operation High Engine Temp Alarm/Shutdown Check Operation Low Coolant Level Alarm/Shutdown Check Operation Over Speed Shutdown Check Operation Over Crank Shutdown Check Operation Over Voltage Shutdown Check Operation Under Voltage Shutdown Check Operation Under Frequency Alarm Check Operation Over Frequency Alarm Check Operation Switch Not In Auto Alarm Check Operation Emergency Stop Check Operation Idle Control Switch Check Operation Voltage/Current Selector Switch Check Operation Notes: VOLTAGE REGULATOR Remote Voltage Adjust As Found As Left Page 5 of 8

Check Generator Connections and Torque Generator Connections Main Feed Connections STATOR VOLTAGE CONNECTED FOR: HI POT: ROTOR RESISTANCE: HI POT: EXCITER ARMATURE EXCITER FIELD RESISTANCE: HI POT: PMG HI POT: REVOLVING RECTIFIER DIODES: SURGE SUPPRESSORS: CONNECTIONS: REGULATOR MODEL: BEARING SURFACES BEARING # : DE: NDE: SHAFT: HOUSING: Page 6 of 8

INSPECT GENERATOR ELECTRICAL CONNECTION & TORQUE QTY. PARTS NUMBER DESCRIPTION NOTES: Page 7 of 8

11115 100 Avenue Telephone (780) 532-5900 Grande Prairie, Alberta Facsimile (780) 532-5904 Canada T8V 3J9 Website Form No: QF-11 Rev.: 0 Date: September 2004 GEN TEST SHEET CUSTOMER DATE JOB # UNIT # ENGINE MAKE MODEL SERIAL SPEC/ARRANGEMENT GOVERNOR FUEL GENERATOR MAKE MODEL RATING VOLTAGE SPEED VOLTAGE REGULATOR LOAD VOLTAGE KW SPEED WATER TEMP OIL TEMP INTAKE TEMP EXHAUST TEMP OIL PRESSURE DURATION COMMENTS: