Instructions for Installation, Operation, Care and Maintenance

Similar documents
Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation Care and Maintenance

Model DDX Deluge Valves 4" (100 mm), 6" (150 mm) and 165 mm Sizes

TECHNICAL DATA. Q= C v P S

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

Model DDX Deluge Valve 8 (200mm) Features

TECHNICAL DATA 1-1/2 (dn40)

Features 1. Differential Latch-type, lightweight, dependable

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

Instructions for Installation, Operation, Care and Maintenance 2 PSI (0,14 bar) Pneumatic Supervising Pressure with Electric Actuation

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

TECHNICAL DATA. Trimpac 249a. September 16, 2013

TECHNICAL DATA. Trimpac 244a. April 15, 2011

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

TECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE

TECHNICAL DATA CAUTION

Instructions for Installation, Operation, Care, and Maintenance

Easy Riser swing check valve Models E-1 & F-1

MODEL RCW NON-INTERLOCK PREACTION SYSTEM

TECHNICAL DATA CONCENTRATE CONTROL VALVE APPLICATIONS, PRIMING CONNECTIONS, AND TRIMS 1. GENERAL DESCRIPTION 2. LISTINGS AND APPROVALS.

MODEL RCW DELUGE SYSTEM ELECTRIC, WET PILOT, AND DRY PILOT ACTUATION

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

Q= C v P S. Flow control valve Model j-2 Halar coated

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL J-2 HALAR COATED 1-1/2 & 2 (DN40 & DN50) 1. DESCRIPTION

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL H-2 HALAR COATED 2 (DN50) - 6 (DN150)

Wet pipe low flow foam/water manifold system

TECHNICAL DATA. Q= C v P S. Table 1 - Valve Part Numbers and Specifications

Model F1 Model F1 Recessed Standard Response Sprinklers

AGCX Bulletin 519 C/Alfoz de Bricia nº4 P.l. Villalonquéjar Burgos (Spain) Tlfno: PAG 1 de 50

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

TECHNICAL DATA P S. Q= Cv MODEL E-2 DELUGE VALVE HALAR COATED ANGLE STYLE

FRAME STYLE SPRAY NOZZLES TECHNICAL DATA

Preaction System with DV-5 Deluge Valve Double Interlock Electric/Electric Actuation. General Description. Page 1 of 14 DECEMBER 2014 TFP1465

TotalPac 3 Deluge, Electric release Remote controlled system

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

TECHNICAL DATA 2-1/2-8 (dn65 - dn200)

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

SHORTER. LIGHTER. MORE VERSATILE. 1 VALVE 10 TRIM CONFIGURATIONS 4" AND 6" MODEL RCW WATER CONTROL VALVE FOR DRY, PREACTION AND DELUGE APPLICATIONS

DELUGE VALVE DATA SHEET

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

Model F1 Res Sprinklers engineered for the lowest flows to meet the minimum design density of.05 gpm/ft 2

TECHNICAL DATA OBSOLETE

DV-5a Automatic Water Control Valve Double Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

1-1/2 Inch (DN40) 9 lb (4,1 kg) Groove Groove 1 8 lb (3,6 kg) Flange Groove 1 N/A N/A. Flange Flange N/A N/A

TECHNICAL DATA OBSOLETE. Inlet Type Outlet Type in mm. Thread Thread in. ANSI B Flanged Flanged in.

TotalPac 3 Deluge system Pneumatic release

Worldwide Contacts.

DV-5 Deluge Valve Aluminium Bronze Diaphragm Style General Description

DV-5A Automatic Water Control Valve Remote-Resetting Deluge Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Model QRS Electronic Accelerator (Quick Opening Device) For Dry Pipe or Preaction Systems General Description

TotalPac 3 Firecyle III Wet pipe Remote controlled system

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 2-4

Technical Data. UL Listing is based on the following criteria:

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York Bulletin 617 Rev. C

Section O Preaction Systems

FireFlex DUAL Single Interlock, Remote controlled system

Maintenance Information

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

TotalPac 3 Non interlock Preaction system Pneumatic release

TotalPac 3 Non interlock Preaction, Electric release Remote controlled system

Model RM-1 Riser Manifold Commercial and Residential General Description

Series 758 FireLock Actuated System Valve

model E Spray nozzles vk810 - vk817

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Remote controlled system

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

Series 769 FireLock NXT Deluge Valve

TotalPac 3 Double interlock Preaction, Electric/Pneumatic release Remote controlled system

Section N Deluge Systems

Colt Series C400, C500

Grooved Piping System for Fire Protection Services

LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES

Baumann Series Flexsleev Control Valve Instructions

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

SD Bendix E-10PR Retarder Control Brake Valve DESCRIPTION. OPERATION - Refer to Figure 2

Baumann Sanitary Diaphragm Angle and Inline Control Valve

Anderson Greenwood Series 800 POSRV Installation and Maintenance Instructions

Installation for L1100, L1200, L1200N Series Liquid Level Switches and DVU150, DVU175, and DVU2105/2115/2120 Series Dump Valves. GENERAL INFORMATION

BLACKMER BYPASS VALVES

Table Summary of Sprinkler System Inspection, Testing, and Maintenance. Reference. Inspection , ,

Powers Controls 656 Powermite Valve with 3-inch Top Rebuilding

Fisher 657 Diaphragm Actuator Sizes and 87

Anderson Greenwood Series 400 Piston Pilot POPRV Installation and Maintenance Instructions

Inverted High Pressure Fluid Filters

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

CIRCLE SEAL CONTROLS

Maintenance Information

I-NXT.RBKIT 5-Year Rebuild Kit Instructions for FireLock NXT Valves

TYPE E Main Valve Sizes 3 /8 through 12

TotalPac 3 Double interlock Firecyle III Preaction Remote controlled system

CIRCLE SEAL CONTROLS

Transcription:

Model H Deluge Riser Assembly Bulletin 507 Rev.C Bulletin 507 Rev.C Instructions for Installation, Operation, Care and Maintenance 1 1 2 (40mm) Size Electric Actuation The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523

General Model H 1½ (40mm) Deluge Riser incorporates a solenoid operated diaphragm type valve as the primary valve in deluge, preaction, or special types of fire protection systems. The valve is easily reset by external means which eliminates the need for removing the cover. The trim is factory assembled for every Model H Deluge Riser. This trim provides valve supervising and waterflow alarm electric connections, pressure gauges, and system draining provisions. Actuation by solenoid enables a full range of electrical detectors to be used for remote sensing. Operation Model H 1½ (40mm) Deluge Riser employs a quick opening hydraulically operated, diaphragm actuated solenoid valve. De-energized: supply pressure is retained at the solenoid valve inlet. Flow through the valve is prevented by a plunger closing off the diaphragm pilot orifice and a diaphragm sealing against the main orifice. Energized: the plunger is lifted off the pilot orifice and vents the pressure behind the diaphragm. The venting creates a pressure imbalance across the diaphragm, which causes the diaphragm to open the main orifice allowing flow through the solenoid valve. Once the solenoid valve has opened, water flows from the supply through the Deluge Riser into the piping system and to the alarm initiating water flow pressure switch. After system shutdown and draining, the Deluge Riser is easily reset, without special tools, by first restoring detection devices to the ready condition. Once the detection system is ready, the releasing control panel can be reset which automatically resets the solenoid valve. Next, the water supply pressure can be restored and the Deluge Riser will be reset. The external reset feature of the Model H 1½ (40mm) Deluge Riser provides a means for simple, economical system testing which is one essential facet of a good maintenance program. Technical Data 1. Rated working pressure 175 psi (12,1 bar). Minimum Supply Pressure: 20 PSI (1,4 Bar) Note: 1 bar=100 kpa 2. End connections - American Standard Taper Pipe Threads per ANSI B2.1. Inlet and outlet 1½.Drain¾. 3. Color-galvanized pipe and fittings with bronze valves. 4. Shipping Weight - 52 lbs. (23.3 Kg) 5. Friction Loss - expressed in equivalent length of Sch. 40 pipe, based on Hazen & Williams formula with C=120 is 29 ft. (8.84m) for the Model H Riser Assembly. 6. Installation position: Vertical 7. Listed by Underwriters Laboratories, Inc. special system water control valves - deluge type (VLFT). Listed by Underwriters Laboratory of Canada. NYC MEA 258-93-E. Figure 1 Model H Deluge Riser Assembly 2.

Installation Model H 1½ (40mm) Deluge Riser Assembly is factory assembled as illustrated in Figure 1. The only piping connections required at the time of installation are an appropriate water supply connection, the system piping connection and a ¾ NPT (R¾) drain line connection. Installation is vertical as illustrated. Electrical connections are required from a releasing control panel to the solenoid valve, supply water control valve supervising switch, and the water flow alarm pressure switch. Refer to Bulletin 700 for further instructions when making these connections to the Potter PFC-4410-RC Releasing/Control Panel used with Reliable Special Hazards & Special Systems. Features and options available for Electrical Deluge and Preaction Systems, including fire detection means, are described in Bulletin 700. Resetting Deluge Riser Assembly Refer to Figures 1 & 2 1. Close the control valve, Item 1. 2. Open drain valve, Item 3, and emergency release station, Item 2, and drain system. 3. Open all drain valves and vents at low points throughout the system, closing them when flow of water has stopped. 4. Inspect and replace any portion of the detection system subjected to fire conditions. 5. Electric actuation - open the solenoid valve, Item 4, by operating a detector or an electric manual emergency station. After residual water has drained through the solenoid valve, cause it to close by resetting the detector or manual station; and thereafter, the Releasing/Control Panel. Refer to Bulletin 700, Special Hazards & Special Systems for details. 6. Close the emergency releasing station, Item 2. Open slightly the control valve, closing drain valve, Item 3, when water flows from it. Close the control valve again and observe supply pressure gauge, Item 6, for any drop in pressure. No pressure drop confirms all valves are leak tight and the Riser Assembly is properly set then the control valve, Item 1, is reopened. 7. Check that the control valve is fully open, and properly supervised. Inspection and Testing Refer to Figures 1 & 2 1. Water supply - be sure the valve, Item 1, controlling water supply to the Deluge Riser is open fully and properly supervised in this position. 2. Other valves - check that valves, Items 2, 3 and 37, are closed and not leaking, by performing Step 6 above. 3. The automatic drain valve, Item 38, monitors internal leakage. Push in on its plunger to be sure ball check is off its seat. If no water appears, the Deluge Riser Assemblyisleaktight. 4. Operation test - Open the solenoid valve, Item 4, using the procedure in Step 5 above. Note: Operation test will cause full flow into the deluge system unless the control valve is throttled or closed prior to performing this test. 5. Reset the Riser Assembly (Steps 1-7 above). Testing Detection System Without Flow Through Deluge Riser 1. Close the control valve, Item 1. 2. Operate detection system - refer to Bulletin 700. 3. Operation of the detection system must result in a sudden drop of water pressure indicated on supply pressure gauge, item 6. When gauge drops to zero, open drain valve until all water above the control valve drains away. 4. Reset detection system - reverse operations performed in Step 2 above. The solenoid valve closes when the Releasing/Control Panel is reset. 5. Reset the Riser Assembly (Steps 1-7 above). Maintenance Reliable Deluge Riser Assemblies and associated equipment shall periodically be given a thorough inspection and test. NFPA 25 provides minimum requirements for inspection, testing and maintenance. The Deluge Riser should be tested, operated, cleaned and inspected at least annually and parts replaced as required. Maintenance Procedures Refer to Figures 2 & 3 Steady water flow into the system, as evidenced by dripping at the automatic drain valve, is caused by water leaking past the solenoid valve or past the emergency station valve. To locate and correct the trouble, proceed as follows: 1. Maintenance of Solenoid Valve Caution: Do not expose plastic or elastomeric materials to any type of commercial cleaning fluid. Parts should be cleaned with a mild soap and water solution. 1.1 Disassemble valve as per the Disassembly Instructions on page 6. Remove extraneous matter. Clean parts in a mild soap and water solution. 1.2 Examine surface of the plunger seal and diaphragm. If damaged, replace plunger or diaphragm. 1.3 Inspect orifices in the body, cover, and diaphragm for nicks or dirt. Clean as necessary. Damage may require a new valve or replacement parts. 1.4 Examine surfaces of the diaphragm or seal in contact with the main orifice. Clean if dirty or replace if damaged or worn. 1.5 Check all springs. If broken, replace. 3.

1½ DELUGE RISER ASSEMBLY, P/N 6503003001 and P/N 6503003007 ( *), PARTS LIST 53 98085668 Couping, Reducer 2 X1½ (Galv.) 1 52 98840181 Valve, Check, ½ 1 51 98840180 Valve, Check, ¾ 1 50 98543209 Nipple, ½ X2 Lg. (Galv.) 1 49 98543228 Nipple, ½ X4½ Lg. (Galv.) 1 48 98543216 Nipple, ½ X3½ Lg. (Galv.) 1 47 98750005 Cross, ¾ (Galv.) 1 46 98815200 Union, ½ (Galv.) 1 45 98761651 Tee, ½ (Galv.) 2 44 98174401 Elbow, ½ (Galv.) 1 43 98174402 Elbow, ¾ (Galv.) 1 42 98048025 Bushing, ¾ X¼ (Galv.) 1 41 98048022 Bushing, ¾ X½ (Galv.) 1 40 98174400 Elbow, ½ Street (Galv.) 2 39 75000075 Cup, Priming, ¾ 1 38 78653100 Valve, Ball Drip, Automatic Drain 1 37 98840109 Valve, Ball ½ 1 36 95106904 Plate, Base, Manual Emer. Station 1 35 95200002 Plug, 1½ (Galv.) 1 33 98085680 Coupling, 1½ Grooved With ¾ NPT Outlet 1 32 98750025 Cross, 2 X1½ (Zinc Coated) 1 31 98614401 Plug, ¾ (Galv.) 1 30 98614403 Plug, ¼ (Galv.) 2 28 6999991339 Switch, Pressure (Eps10-1) 6999992366 Switch, Pressure (Epsa10-2) ( *) 1 27 94606910 Name Plate, Manual Emergency Station 1 26 94616910 Nameplate, 1½ Deluge System 1 25 98543204 Nipple, ½ X6 Lg. (Galv.) 1 24 95106905 Plate, Base 1 23 95306210 Clamping Ring (OETIKER #575) 2 22 95306209 Clamping Ring (OETIKER #515) 2 21 98543227 Nipple, ¼ X Close (Galv.) 2 20 98543212 Nipple, ½ X Close (Galv.) 4 19 98543279 Nipple, ¾ X Close (Galv.) 5 18 98543290 Nipple, ¾ X8 1 2 Lg. (Galv.) 1 17 98543288 Nipple, 1½ X9½ Lg. (Galv.) 1 16 98543276 Nipple, 1½ X3½ Lg. (Galv.) 2 15 98543274 Nipple, 1½ (thd X grv) X 4 Lg. (Galv.) 2 14 98543275 Nipple, 1½ X2½ Lg. (Galv.) 1 13 98543238 Nipple, 2 X Close (Galv.) 1 12 96606625 Tee, 2 X1½ X1½ (Galv.) 1 11 96606621 Tee, 1½ X¾ X1½ (Galv.) 1 10 96606622 Tee, 1½ X½ X1½ (Galv.) 1 9 96606601 Tee, ¾ (Galv.) 1 8 96606607 Tee, ½ X½ X¼ (Galv.) 1 7 98543230 Nipple, 1 2 X3 Lg. (Galv.) 1 6 98248001 Gauge, Pressure, Water 2 5 98840160 Valve, Gauge, 3-Way, ¼ 2 4 6871080000 Valve, Solenoid, 2 1 3 98840170 Valve, Globe, ¾ 1 2 6201001500 Valve, Butterball, 1½ (BB-SC100) 1 1 6201201500 Valve, Butterball, 1½ (BB-SCS02) 1 ITEM NO. PART NO. DESCRIPTION Number REQ D (*) Canadian Type 4.

Figure 2 When difficulty in performance is experienced, contact Reliable Technical Services before any field adjustment is made. Should replacement parts be needed, use only Reliable supplied parts. When ordering specify part number, name, size, model and serial number of the unit. 5.

DISASSEMBLY INSTRUCTIONS WARNING: Depressurize system and turn off electrical power to the valve before attempting repair. The valve need not be removed from the line. To remove the coil assembly: Unscrew the nut on the top of the coil assembly. The wave washer and coil assembly can now be removed. Maximum retightening torque on coil assembly nut is 53 inch-lbs (5.98 Nm). To disassemble the pressure vessel (Ref. Figure 3) Caut on: Do not use a pipe wrench directly on the sleeve tube. These valves contain a hex style flange in the sleeve assembly. A wrench may be applied directly to the hex flange in order to loosen the sleeve assembly. Unscrew the sleeve assembly. The plunger and return spring may now be removed. Maximum retightening torque is 270 inch-lbs (30.5 Nm). Unscrew the four (4) cover screws. If the cover cannot be easily lifted off the body, laterally tap the cover or gently pry the cover from the body with a screwdriver. Care must be taken not to damage diaphragm, cover, or body. Diaphragm return spring(s), diaphragm assembly, and o-rings can now be removed. Maximum retightening torque on cover screws is 135 inch-lbs (15.25 Nm). Replacement Parts: When ordering replacement parts kit, specify part number (P/N 6999991583). Parts included in each kit are marked with an asterisk (*). See exploded view, Figure 3. 2. Maintenance of Emergency Station Valve This valve, Item 2, is not field serviceable. In the event that leakage is occurring it must by replaced with a new manual emergency releasing station. Replacement is made by removing the coupling, Item 33 and loosening the union, Item 46, and then unscrewing the segment of piping which begins with nipple, Item 16, at the inlet to the valve. When ordering replacement valve, Item 2, also order two clamp rings, Item 22, for remounting the nameplate base, Item 36. Make certain both new clamp rings have been slipped onto the nipple, Item 16, above the valve before the new valve is attached to this nipple. After all piping is reconnected, reposition the nameplate, as shown, and tighten the new clamp rings over the two nameplate tabs using crimping pliers to draw the bands tight. FIGURE 3 The solenoid valve is manufactured by the Skinner Valve Division of Parker Hannifin Corp. For more detailed maintenance instructions contact The Reliable Literature Department and request Form 10M 7203. 6.

SOLENOID VALVE INSPECTIONS, TESTS AND MAINTENANCE WARNING: THE OWNER IS RESPONSIBLE FOR MAINTAINING THE FIRE PROTECTION SYSTEM IN PROPER OPERATING CONDITION. ANY SYSTEM MAINTENANCE OR TESTING THAT INVOLVES PLACING A CON- TROL VALVE OR DETECTION SYSTEM OUT OT SERVICE MAY ELIMINATE THE FIRE PROTECTION OF THAT SYSTEM. PRIOR TO PROCEEDING, NOTIFY ALL AUTHORITIES HAVING JURISDICTION. CONSIDERATION SHOULD BE GIVEN TO EMPLOYMENT OF A FIRE PATROL IN THE AFFECTED AREA. WARNING: PRIOR TO OPERATING THE SOLENOID VALVE, BE SURE TO CLOSE THE SYS- TEM CONTROL VALVE TO AVOID UNINTENTIONAL OPERATION OF THE DELUGE VALVE 1. Inspections: It is imperative that the system be inspected and tested in accordance with NFPA 25 on a regular basis. The frequency of the inspections may vary due to contaminated water supplies, corrosive water supplies, or corrosive atmospheres. In addition, the alarm devices, detection systems, or other connected trim may require a more frequent schedule. Refer to the system description and applicable codes for minimum requirements. 2. The valve must be operated at least monthly. The valve must open and close freely. When open, the water flow must be clear and clean at the proper flow rate. When closed, a total water shut-off must be observed. 3. The valve must be inspected at least monthly for cracks, corrosion, leakage, etc., and cleaned, repaired, or replaced, or replaced as necessary. 4. At least annually, the valve diaphragms and seats must be inspected and if necessary, repaired or replaced. WARNING: CLOSE SYSTEM CONTROL VALVE, TURN OFF POWER SUPPLY, AND DEPRESSURIZE VALVE BEFORE DISASSEMBLING VALVE. IT IS NOT NECESSARY TO REMOVE THE VALVE FROM THE PIPE LINE TO MAKE INSPECTIONS. 5. When lubricating valve components, use high grade silicone grease (Dow Corning 111 Compound Lubricant or equal). 6. When reassembling, tighten parts to torque values indicated in the manufacturer s maintenance instructions (packed with valve). 7. After maintenance is completed, operate the valve a few times to be sure of proper operation. A metallic click signifies the solenoid is operating. 8. It is recommended that the valve be replace at seven-year intervals. Shorter intervals may be required if the valve is subject to corrosive water supplies or atmospheres. 9. All service must be performed by qualified personnel. Upon completion of inspections or replacement of the valve, the entire system must be checked for proper operation. See appropriate system description and testing instructions for additional information. 7.

Ordering Information Specify (Ref. Figure 4): Item No. Component Part Mfgr. Description Technical Bulletin 1 Deluge Riser Assembly B Model H 507 2 Releasing / Control Panel Batteries Optional Accessories 3 Alarm Annunciator A 4 Trouble Annunciator C A Model PFC-4410-RC 12 VDC, 12 AMP Hours (90 Hours Backup) FM 12 VDC, 7 AMP Hours (60 Hours Backup) CA2Z (Class A Wiring Module for Initiating Circuits) CAM (Class A Wiring Module for Indicating Circuits) ARM-1 / ARM-2 (Auxiliary Relay Module) RA-4410-RC (Remote Annunciator) Model SSM24-8 24 VDC / Polarized Bell Model SSM24-10 24 VDC / Polarized Bell Model MA24-D 24 VDC / Polarized Sounder Model MASS24LO 24 VDC / Polarized Sounder Strobe Model SSM24-6 24 VDC / Polarized Bell Model MA24-D 24 VDC / Polarized Sounder Potter #5403550 Reliable 700 Reliable 700 Reliable 700 5 Manual Emergency Station (Elec.) A Model BNG-1 (SPDT) 1 & 2 Area Detection Model BNG-1F (DPDT) Cross Zoned Detection Reliable 700 6 Detection Various Smoke, Heat Detectors, etc. Reliable 722 7 Sprinklers B Open Type Reliable 104/106 System Equipment Manufacturers (A)Notifier (B)The Reliable Automatic Sprinkler Co., Inc. (C) Potter Electric Signal Company Patents U.S. Patent number 5,720,351 Figure 4 Model H Deluge System 8.

9.

Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Special hazards & special systems Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Www.reliablesprinkler.com Internet Address Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A 05/08 P/N 999990118