Height Adjustable Dual Flush Siphon

Similar documents
Compact Concealed Toilet Cistern with Dual flush CNC1001

C25. Parts supplied: 1: Flush Valve installation

DUAL FLUSH VALVE SKIPPER 45 BOTTOM INLET VALVE COMPACT 99B ASSEMBLY INSTRUCTIONS

C24 C30. Parts supplied: 1: Flush Valve installation

WC Frames CHRONO INTRAMUROS PPX 2 IN 1 PUSH PLATES WC FRAMES

Installation must be in Accordance with AS/NZS

Insert the lower end of the flush pipe into the pan via the flush cone (supplied as part of the cistern fittings). HANDY HINT

FlushMaster Cistern & Valve assembly

G SERIES - E TOUCH MIXER / TAP

OWNER S MANUAL GUZZLER MODEL 620 READ THESE INSTRUCTIONS BEFORE USING

Operating Manual. Hydra S (W)VAC

3 litres. 6 litres. Lever Flush Cistern Fittings - Close Coupled / Low Level Cistern 51cm - Close Coupled / Low Level Cistern 44cm

MASTER CYLINDER MC9601

SERIES II WALVIT + CUBE. 1.28/0.8 Gal (4.8/3 Litre)

Close Coupled/Low Level Cistern 51cm Ceramic lever C1 Close Coupled/Low Level Cistern 51cm Ceramic Front Button C2. 1: Inlet Valve 2: Flush Valve

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, STAINLESS STEEL, FLOOR MODEL, *SHOCK TESTED. Fresh water.

CALIFORNIA TRIMMER MOWER MAINTENANCE MANUAL

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

SP0 & SP1 Knapsack Sprayer

Installation Instructions 7024

Skim Skim V 2 Protein Skimmers

Installation and Operation Instructions

Easy Fountain Instructions 45040L Rattan Weave

Retro Kit 200 / 300. Installation & Operating Instructions. Note: Do not attempt to install this Module without first reading this manual thoroughly


Installation instruction do88 Performance Radiator for Volvo S60 V70 XC70 S

OPERATOR S MANUAL Model 60010

Troubleshooting Guide for Pumps ATD ATD ATD5289

EQUALIZER International Limited 10T(I) Integral Hydraulic Spreading Wedge Repair Instruction Manual

kb valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN):

Zip FlushMaster Surface mounted sensor

4. FUEL SYSTEM CK 1 4-0

Installation Instructions

DT34 and DT54 Series Rotary Sprinklers

Breezair TBA 550 Installation Manual

INSTALLATION INSTRUCTIONS

Installation Instructions

Lever Flush Cistern Fittings Arcade close coupled cistern ARC5C

MAINTENANCE MANUAL DI 16

Safety, Operation and Maintenance Instructions For Long & Short Nose Upholstery Air Stapler (NS10 & NS11)

INSTALLATION INSTRUCTIONS

Porsche 911/996/997 Carrera Do-It-Yourself Convertible Top Hydraulic Cylinder Inspection, Removal and Shipping Instructions

INSTALLATION INSTRUCTIONS PATIENCE

INSTALLATION INSTRUCTIONS for EXPOSED SENSOR-FLUSH FLUSH VALVES

5. FUEL SYSTEM 5-0 FUEL SYSTEM MXU 250R/300R

Inst all a ti o n and Oper a tin g Instru c ti o n s

1 of 11 4/11/ :35 AM

Quadra Single Lever Mono Basin Mixer. Telephone Parts and Specification

DP33 Pump. 60:1, 3+3, Air-operated, Grease. General. Operation. Technical Data. Installation R2 08/15

TRENCH & CLAY DIGGERS

Tools Needed for Mounting Cleá Filling Station

AIR CLEANER GENERAL REMOVAL. 1CAUTION Do not run engine without filter element in place. Debris could be drawn into the engine causing damage.

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL

Installation Instructions

Level 1 and Level 2/3 Fork Upgrade Fitting Instructions

DAH Left Hand Hose Inlet Kit Instruction Sheet For Use with 700 SERIES DAH Dilution at Hand Blend Centers

OPERATION AND MAINTENANCE MANUAL

WARNING: the engine does not come with oil in it. Please fill the oil before starting. The 200cc hardknock requires 9/10 of a quart of oil.

DT35 and DT55 Series Rotary Sprinklers Installation & Service Instructions

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

12. CARBURETOR 12-0 CARBURETOR VITALITY 50

HE Stewart Vacuum Gasoline System employs a small tank, installed under the hood. This tank is connected by brass tubing to the intake manifold, also

Central locking system

Instruction Model 18537

and 1/4 TURN SECOND STAGE REGULATOR TAL 502 (L) Rev. 0 MSA 2005 Prnt. Spec (I) Mat Doc

INSTALLATION INSTRUCTIONS for EXPOSED PULSAR FLUSH VALVES

Installation Instructions

Transmission MV702. Product Installation & Troubleshooting

Brake Upgrade Kit Fitting Instructions Bonneville America

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

OWNER S MANUAL. Model: LG-25-BL-QR ( ) (25 Gallon ATV Dual Nozzle Sprayer) ***IMPORTANT REMINDER*** Technical Specifications

2006 RECON SERVICE GUIDE

SW20 Coolant System Maintenance.

Service Bulletin Trucks Date Number Page


D L Y AU S T L IAN D ESI SPRINTA PLUS OWNER S MANUAL. SOC33548 Sprinta instructions_art3.indd 1

180 Lake Ave North Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

OWNER S MANUAL Model: LG ( ) (25 Gallon Lawn & Garden Trailer Sprayer)

Technical Manual. Table of Contents


Stand Alone Fog Lights Installation Instructions

MS604114CEF(G) MS634114CEF(G) MS853113E MS853113S MS854114ES(L) MS863113(E) MS864114(E)(L) MS MS924154F

WARNING Carefully Read These Instructions Before Use

Installation Instructions

INSTALLATION INSTRUCTIONS STUDIO S

SW14.5TI INTEGRAL HYDRAULIC FLANGE SPREADING WEDGE. Repair Manual INNOVATION IN ITS MOST FUNCTIONAL FORM

FUEL SYSTEM. Table of Contents. Specifications. Section 3A Fuel Delivery System. Models 6/8/9.9/10/15 CARBURETOR SPECIFICATIONS

Pneumatic Mechanisms

Key Installation Points. Table of Contents

Aquaflush. Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6000 Z6003

Backpack Sprayer. Use and Care Manual

Installation Instructions

Plastic Overflow Pipe and Fittings SECTION

Plastic Overflow Pipe and Fittings SECTION. Plastic Overflow Pipe and Fittings

Thermo-Bob 4 Installation Manual. TB4-KT4A Kit KTM 450 SX-F KTM 450 XC-F Husky FC450

XP-AIR Multi-Port Power Pack Operation and Maintenance Manual

Aquaflush. Z6100 Series Aquaflush Concealed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6140

150 Series Brass Horizontal Float Valve. Technical Information

IBT Series Square Drive Torque Wrenches

Installation Instructions Series Series

Transcription:

No Code No Description 7 00 00 Macdee Motion Flush selector Macdee Motion siphon cap with chimney 00 Macdee Motion piston base and flaps 8 007 008 009 Macdee Motion Lock Macdee Motion bell housing Macdee Motion threaded collar Height Adjustable Dual Flush Siphon 7 8 000 00 Macdee Motion u bend Macdee Motion o ring FITTING INSTRUCTION LEAFLET 9 00 Macdee Motion down leg 0 007 Macdee Motion instruction leaflet 00 For full range Wirquin products go to : www.wirquin.com Macdee Motion fittings pack (siphon washer - siphon backnut - siphon coupling nut - low level sealing washer - x / c-link x /8 c-link) 9 PRODUCT FAMILY FOR THE MACDEE MOTION DCA0WH White Ceramic Handle DCA0CP Chrome Handle DCA700 Universal Adjustable Arm and Screw DCP00 Close Coupling Plated Kit and Bolted Kit DCA80 Close Coupling (Foam) DCA00 Close Coupling (Rubber) DFP0WH x 9 White Flushpipe DFP09WH x White Flushpipe DFP0WH Ê pce Back to Wall High Level Flushpipe DFPWH 7Ê 0 pce Back to Wall High Level Flushpipe DFPWH 7Ê 0 pce Side Wall High Level Flushpipe CONTENTS Tools required : - Sponge - Bucket - Adjustable spanner - / grips - Sheet - Tape Measure Pre-Installation Page Installation for High or Low Level Cisterns Page Installation for Close Coupled Level Cisterns Page Reduced / Full Flush Settings / Lid Locking Page Trouble Shooting Page - 7 Code Number Issue Date Version 007 09/08/0 0 Technical services number - + (0) 0 0

PRE - TROUBLESHOOTING DIAGRAMS Turn f water supply to cistern and remove cistern lid. Internal Overflow Before emptying cistern water, mark water level inside cistern (if cistern does not have water line inside cistern) and empty cistern water. Tip : Use sponge to take residual water out inside = height water level in Cistern Disconnect water supply from inlet valve and remove cistern, remove old siphon, clean inside cistern any debris / dirt. Chamber = height water level in Cistern REMOVE THE LOCK clip. Measure height water level inside cistern and adjust height siphon (see picture). Fit LOCK clip to lock height siphon. 7

TROUBLESHOOTING OBSERVATIONS PROBLEMS SOLUTIONS The water level in cistern is above internal overflow height siphon Water is running into pan Water is leaking back into pan or onto floor flushing pan clean flushing pan clean on part flush The siphon will not flush The siphon is not flushing The inlet valve is not shutting f. Water is leaking from base cistern - in between pan and cistern or flushpipe. Water is running down flushpipe. amount water into pan. flush into pan When flushed only setting small flush into pan on part flush. The is in downward postion. No water is being flushed. One or both flapper(s) has come f retaining clip(s). Increase height siphon as per instruction page 7. Internal overflow height is marked on siphon. Clean inlet valve diaphragm if problem continues replace inlet valve. Check sealing washer has been fitted on inside cistern and backnut is tight if required give backnut / turn until watertight. Check backnut is tight if required give backnut / turn until watertight - check flushpipe sealing washer is not kinked or twisted and coupling nut is watertight. The siphon is dual flush Full flush hold down until flush has stopped - Part flush press down and release. Check flush selection instruction page 7. Check that siphon is correctly set as per instruction page 7. Make sure adjustable arm is attached to c-link and see page instruction. Make sure chamber by piston rod has water in it as this acts as a seal diagram page 7. Remove Motion from cistern leaving syphon leg in situ, remove c-link and gently squeeze clips on piston rod and n slowly push push rod down until piston base is free bell-housing and n clip flapper(s) back onto retaining clip(s), once this has been completed put piston base/rod back in bell-housing - attach c-link to piston rod and put Motion back onto siphon leg. INTERNAL OVERFLOW INFORMATION The Macdee Motion siphon comes complete with internal overflow but always check internal overflow level (marked on siphon) is always below any hole inside cistern where water can escape. Always check internal overflow can cope with incoming water supply by holding inlet valve down and allow water to fill inside If internal overflow cannot cope reduce incoming water by turning isolation valve down until internal overflow can cope. FOR HIGH OR LOW LEVEL CISTERNS Place rubber sealing washer (item ) on threaded tail Macdee Motion siphon and insert through cistern outlet hole (sealing washer must be on inside cistern). Place backnut (item ) on threaded tail and hand tighten and n / turn using adjustable spanner or grips. Tip : Put small amount water inside cistern and check for leaks if required give furr / turn using adjustable spanner or grips. Place coupling nut (item ) and flushpipe sealing washer (item ) onto flushpipe and insert flushpipe into tail siphon (0mm maximum), make sure sealing washer is not kinked or twisted n hand tighten coupling nut up. Attach adjustable arm on cistern lever to metal c-link. Use appropriate c-link so is set in o clock position. Turn water supply on and check installation is functional and water tight. on siphon. * Not included replacement * DFP0WH x 9 flushpipe * DCA700 Universal arm and screw Back nut Coupling nut Flush pipe Cistern base

FOR CLOSE COUPLED CISTERNS Place rubber sealing washer (item ) on threaded tail Macdee Motion siphon and insert through cistern outlet hole (sealing washer must be on inside cistern). Place close coupling plate (item ) onto threaded tail siphon and hand tighten siphon backnut (item ) and n turn / turn using adjustable spanner or grips. Tip : Put small amount water inside cistern and check for leaks if required give furr / turn using adjustable spanner or grips. Place close coupling washer (item ) onto threaded tail siphon and slide bolts into close coupling plate. Tip : Use new close coupling sealing washer when changing or replacing existing flushing siphon or valve this will stop chance leaks. Carefully connect cistern to pan and secure in place. Attach adjustable arm on cistern lever to metal c-link. Use appropriate c-link so is set in o clock position. Turn water supply on and check installation is functional and water tight. FOR THE REDUCED FLUSH Press cistern Release. R down Adjustable reduced flush. depends on t FOR THE FULL FLUSH P Press cistern Hold until flush has down finished Adjustable full flush. H on siphon. Screws* T depends on LID LOCKING SECURITY SYSTEM The cistern lid can be secured to siphon but only if cistern lid has hole already punched into it. (screw not included). Metal plate* Back nut Close Coupling *Not included DCP 00 CLOSE COUPLING KIT Nuts*

FOR CLOSE COUPLED CISTERNS Place rubber sealing washer (item ) on threaded tail Macdee Motion siphon and insert through cistern outlet hole (sealing washer must be on inside cistern). Place close coupling plate (item ) onto threaded tail siphon and hand tighten siphon backnut (item ) and n turn / turn using adjustable spanner or grips. Tip : Put small amount water inside cistern and check for leaks if required give furr / turn using adjustable spanner or grips. Place close coupling washer (item ) onto threaded tail siphon and slide bolts into close coupling plate. Tip : Use new close coupling sealing washer when changing or replacing existing flushing siphon or valve this will stop chance leaks. Carefully connect cistern to pan and secure in place. Attach adjustable arm on cistern lever to metal c-link. Use appropriate c-link so is set in o clock position. Turn water supply on and check installation is functional and water tight. FOR THE REDUCED FLUSH Press cistern Release. R down Adjustable reduced flush. depends on t FOR THE FULL FLUSH P Press cistern Hold until flush has down finished Adjustable full flush. H on siphon. Screws* T depends on LID LOCKING SECURITY SYSTEM The cistern lid can be secured to siphon but only if cistern lid has hole already punched into it. (screw not included). Metal plate* Back nut Close Coupling *Not included DCP 00 CLOSE COUPLING KIT Nuts*

TROUBLESHOOTING OBSERVATIONS PROBLEMS SOLUTIONS The water level in cistern is above internal overflow height siphon Water is running into pan Water is leaking back into pan or onto floor flushing pan clean flushing pan clean on part flush The siphon will not flush The siphon is not flushing The inlet valve is not shutting f. Water is leaking from base cistern - in between pan and cistern or flushpipe. Water is running down flushpipe. amount water into pan. flush into pan When flushed only setting small flush into pan on part flush. The is in downward postion. No water is being flushed. One or both flapper(s) has come f retaining clip(s). Increase height siphon as per instruction page 7. Internal overflow height is marked on siphon. Clean inlet valve diaphragm if problem continues replace inlet valve. Check sealing washer has been fitted on inside cistern and backnut is tight if required give backnut / turn until watertight. Check backnut is tight if required give backnut / turn until watertight - check flushpipe sealing washer is not kinked or twisted and coupling nut is watertight. The siphon is dual flush Full flush hold down until flush has stopped - Part flush press down and release. Check flush selection instruction page 7. Check that siphon is correctly set as per instruction page 7. Make sure adjustable arm is attached to c-link and see page instruction. Make sure chamber by piston rod has water in it as this acts as a seal diagram page 7. Remove Motion from cistern leaving syphon leg in situ, remove c-link and gently squeeze clips on piston rod and n slowly push push rod down until piston base is free bell-housing and n clip flapper(s) back onto retaining clip(s), once this has been completed put piston base/rod back in bell-housing - attach c-link to piston rod and put Motion back onto siphon leg. INTERNAL OVERFLOW INFORMATION The Macdee Motion siphon comes complete with internal overflow but always check internal overflow level (marked on siphon) is always below any hole inside cistern where water can escape. Always check internal overflow can cope with incoming water supply by holding inlet valve down and allow water to fill inside If internal overflow cannot cope reduce incoming water by turning isolation valve down until internal overflow can cope. FOR HIGH OR LOW LEVEL CISTERNS Place rubber sealing washer (item ) on threaded tail Macdee Motion siphon and insert through cistern outlet hole (sealing washer must be on inside cistern). Place backnut (item ) on threaded tail and hand tighten and n / turn using adjustable spanner or grips. Tip : Put small amount water inside cistern and check for leaks if required give furr / turn using adjustable spanner or grips. Place coupling nut (item ) and flushpipe sealing washer (item ) onto flushpipe and insert flushpipe into tail siphon (0mm maximum), make sure sealing washer is not kinked or twisted n hand tighten coupling nut up. Attach adjustable arm on cistern lever to metal c-link. Use appropriate c-link so is set in o clock position. Turn water supply on and check installation is functional and water tight. on siphon. * Not included replacement * DFP0WH x 9 flushpipe * DCA700 Universal arm and screw Back nut Coupling nut Flush pipe Cistern base

PRE - TROUBLESHOOTING DIAGRAMS Turn f water supply to cistern and remove cistern lid. Internal Overflow Before emptying cistern water, mark water level inside cistern (if cistern does not have water line inside cistern) and empty cistern water. Tip : Use sponge to take residual water out inside = height water level in Cistern Disconnect water supply from inlet valve and remove cistern, remove old siphon, clean inside cistern any debris / dirt. Chamber = height water level in Cistern REMOVE THE LOCK clip. Measure height water level inside cistern and adjust height siphon (see picture). Fit LOCK clip to lock height siphon. 7