Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Similar documents
Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Thermocouple For additional thermowell Model TC10-B

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Measuring insert for process resistance thermometer

Thermocouple Without thermowell Model TC10-H

Resistance thermometer Without thermowell Model TR10-H

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Measuring insert for resistance thermometer Model TR10-A

Resistance thermometer Model TR10-E, for additional thermowell

Thermocouple with spring-loaded tip Model TC55

Surface thermocouple Model TC50

Thermocouple Model TC10-E, for additional thermowell

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Thermocouples Model TC10-B, for Additional Thermowell

Resistance thermometer Model TR10-B, for additional thermowell

Thermocouple Model TC10-H without thermowell

Thermocouples Model TC10-E, for Additional Thermowell

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Resistance thermometer with digital display Model TR75, battery operation

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J

Cable resistance thermometer Model TR40

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Cable thermocouple Model TC40

Tubeskin thermocouple assembly Model TC59-W

Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A

Tubeskin thermocouple assembly Model TC59-V

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Tubeskin thermocouple assembly Model TC59-V

Resistance thermometer For sanitary applications Model TR22-A, exchangeable sensor

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

Duct thermometer Model TF40

Resistance thermometer with digital indicator Model TR75, battery operation

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

Reed sensor For bypass level indicators Model BLR

Cable resistance thermometer Model TR40

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Cable thermocouple Model TC40

Cable resistance thermometer Model TR40

Insertion thermometer With connection lead Model TF45

Temperature multi-function calibrator Model CTM

Hot runner thermocouple Model TC46

Differential pressure gauge with switch contacts For the process industry, all-metal media chamber Models DPGS43.100, DPGS43.160

Differential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT and DPGT43.160

Compact temperature switch Model TCS

Mechatronic pressure measurement. Applications. Special features. Description

Bimetal thermometer Model 52, industrial series

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40TA, with component testing

Bourdon tube pressure gauge with switch contacts Stainless steel case Model PGS21, NS 100 and 160

Bimetal thermometer Model 52, industrial series

Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Mini temperature switch Stainless steel switch enclosure Model TXS

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40

Differential pressure gauge For the process industry Models , , high overload safety up to 40, 100 or 400 bar

Differential pressure gauge with electrical output signal Model A2G-15

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

Compact pressure switch Model PCS

Thermowell For sanitary applications Model TW61, for orbital welding

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Thermowell For sanitary applications Model TW61, for orbital welding

High-pressure thermocouple Model TC90

Mini pressure switch Stainless steel switch enclosure Model PXS

Gas-actuated thermometer Highly vibration resistant Model 75, stainless steel version

Bourdon tube pressure gauge, copper alloy Panel mounting series Models and

Differential pressure gauge with switch contacts For the process industry Models DPGS43HP.1x0, high overload safety up to 40, 100, 250 or 400 bar

Compact differential pressure switch Models DC, DCC

Cable thermocouple Model TC40

Differential pressure switch Model DPS40

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Diaphragm seal with threaded connection Plastic version Model

Diaphragm seal with sterile connection For homogeniser machines Model

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Accessories for diaphragm seals Block flange and saddle flange Models , ,

Gas-actuated thermometer with switch contacts Model 73, stainless steel version

Diaphragm pressure gauge, flush For sanitary applications Model PG43SA-S, NS 100

OEM pressure transmitter with thin-film technology For mobile hydraulics Model MH-2

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

Pressure switch, high adjustability of switch differential

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

INSTRUCTION MANUAL (ATEX / IECEx)

Diaphragm seal with sterile connection With union nut (milk thread fitting) Models , , and

Thermocouples TE Measuring Insert. rigid Model TC 001 flexible Model TC 002. Electronic Temperature Measurement

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB

Bimetal thermometer with Pt100 electrical output signal Model 54, stainless steel version

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB

Diaphragm pressure gauge, flush For sanitary applications, NS 100 Model PG43SA-D, with integrated diaphragm element monitoring

Diaphragm seal with flange connection For the pulp and paper industry Model

INSTRUCTION MANUAL (ATEX / IECEx)

Gas-actuated thermometer Model 73, stainless steel version

Thermowell For sanitary applications Model TW61, for orbital welding

Spring loaded resistance thermometer

For the plastics machinery industry Manifold thermocouple Model TC47-MT

Pressure gauge per EN with mounted diaphragm seal With threaded connection, threaded design Model DSS10M

Screw-in thermometer with connection lead Model TF37

Differential pressure gauge Model , copper alloy Model , stainless steel version

Hot Runner Thermocouples Model TC46

Transcription:

Temperature Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L WIKA data sheet TE 65.12 for further approvals see page 2 Applications Chemical industry Petrochemical industry Offshore Special features Sensor ranges from -40... +1,200 C (-40... +2,192 F) Measuring insert replaceable For many thermowell designs Description Thermocouples in this series can be combined with a large number of thermowell designs. Use without a thermowell is not permitted. Fig. left: Model TC10-L with connection head 7/8000 Fig. right: Model TC10-L with connection head 1/4000 A wide variety of possible combinations of sensor, connection head, insertion length, neck length, connection to thermowell etc. are available for the thermometers; suitable for almost any thermowell dimension. Page 1 of 12

Explosion protection (option) The permissible power P max as well as the permissible ambient temperature for the respective category can be seen on the EC-type examination certificate, the Ex certificate or in the operating instructions. Attention: Only with the correspondingly suitable protective components is operation in dust Ex hazardous areas permissible. The built-in transmitter has its own certificate. The permissible ambient temperature ranges of the built-in transmitters can be taken from the corresponding transmitter approval. Approvals (explosion protection, further approvals) Logo Description Country EU declaration of conformity EMC directive 1) EN 61326 emission (group 1, class B) and immunity (industrial application) RoHS directive ATEX directive (option) Hazardous areas European Union - Ex d Zone 1 gas [II 2G Ex db IIC T1... T6 Gb] - with suitable solid-machined thermowell [II 2G Ex db IIB + H 2 T1... T6 Gb] Zone 21 dust [II 2D Ex tb IIIC T85 C Db IP66] IECEx (option) International (in conjunction with ATEX) Hazardous areas - Ex d Zone 1 gas [Ex db IIC T1... T6 Gb] - with suitable solid-machined thermowell [Ex db IIB + H 2 T1... T6 Gb] Zone 21 dust [Ex tb IIIC T85 C Db IP66] EAC (option) Hazardous areas - Ex d Zone 1 gas [1 Ex d IIC T1... T6] Zone 21 dust [DIP A21 Ta 80... 440 C] INMETRO (option) Hazardous areas - Ex d Zone 1 gas [Ex d IIC T* Gb IP66] [Ex d IIB + H 2 T* Gb IP66] DNOP - MakNII (option) Hazardous areas - Ex d Zone 1 gas [II 2G Ex d IIB + H 2 T4... T6] + [II 2G Ex d IIC T4... T6] Zone 21 dust [II 2D Ex td A21 IP66 T85 C] GOST (option) Metrology, measurement technology KazInMetr (option) Metrology, measurement technology - MTSCHS (option) Permission for commissioning BelGIM (option) Metrology, measurement technology UkrSEPRO (option) Metrology, measurement technology Uzstandard (option) Metrology, measurement technology Eurasian Economic Community Brazil Ukraine Russia Kazakhstan Kazakhstan Belarus Ukraine Uzbekistan Manufacturer s information and certificates Logo Description SIL 2 Functional safety (only in conjunction with model T32 temperature transmitter) 1) Only for built-in transmitter Approvals and certificates, see website Page 2 of 12

Sensor Thermocouple per IEC 60584-1 or ASTM E230 Types K, J, E, N, T (single or dual thermocouple) Measuring point Ungrounded (standard) Grounded Sensor types Type Operating temperatures of the thermocouple IEC 60584-1 ASTM E230 Class 2 Class 1 Standard Special K -40... +1,200 C -40... +1,000 C 0... 1,260 C J -40... +750 C -40... +750 C 0... 760 C E -40... +900 C -40... +800 C 0... 870 C N -40... +1,200 C -40... +1,000 C 0... 1,260 C T -40... +350 C 0... 370 C The table shows the temperature ranges listed in the respective standards, in which the tolerance values (class accuracies) are valid. The actual operating temperature of the thermometer is limited both by the maximum permissible working temperature and the diameter of the thermocouple and the sheathed cable, as well as by the maximum permissible working temperature of the thermowell material. Listed models are available both as single or dual thermocouples. The thermocouple will be delivered with an ungrounded measuring point. For detailed specifications for thermocouples, see IEC 60584-1 or ASTM E230 and Technical information IN 00.23 at www.wika.com. Tolerance value For the tolerance value of thermocouples, a cold junction temperature of 0 C has been taken as the basis. Electrical connection Single thermocouple Dual thermocouple The colour coding at the positive poles of the instrument decides the correlation of polarity and terminal. 3166822.03 For the electrical connections of built-in temperature transmitters see the corresponding data sheets or operating instructions. Page 3 of 12

Connection head 1/4000 F 1/4000 S 7/8000 W 7/8000 S 7/8000 W / DIH50 7/8000 S / DIH50 Cover / Cap Surface Connection Model Material Cable entry thread size Ingress protection (max.) 1) to neck tube 1/4000 F Aluminium ½ NPT, ¾ NPT, M20 x 1.5 IP66 4) Screw-on lid Blue, lacquered 2) ½ NPT 1/4000 S Stainless steel ½ NPT, ¾ NPT, M20 x 1.5 IP66 4) Screw-on lid Blank ½ NPT 7/8000 W Aluminium ½ NPT, ¾ NPT, M20 x 1.5 IP66 4) Screw-on lid Blue, lacquered 2) ½ NPT 7/8000 S Stainless steel ½ NPT, ¾ NPT, M20 x 1.5 IP66 4) Screw-on lid Blank ½ NPT 7/8000 W / Aluminium ½ NPT, ¾ NPT, M20 x 1.5 IP66 4) Screw-on lid Blue, lacquered 2) ½ NPT DIH50 3) 7/8000 S / DIH50 3) Stainless steel ½ NPT, ¾ NPT, M20 x 1.5 IP66 4) Screw-on lid Blank ½ NPT 1) The ingress protection refers to the connection head, for information on the cable glands, see page 5 2) RAL 5022 3) DIH50 LC display 4) Suitable seal/cable gland required Connection head with digital display Flame path fitting A flame path fitting is built into the connection head which, in conjunction with the measuring insert, generates a flameproof gap. Connection head 7/8000 W with LC display model DIH50 see data sheet AC 80.10 To operate the digital display, a transmitter with a 4... 20 ma output is always required. Fig. left: Flame path fitting for model 1/4000 connection head Fig. right: Flame path fitting for 7/8000 and 7/8000 connection heads with DIH50 Page 4 of 12

Cable entry Ex d cable gland stainless steel Plain threaded Sealing plugs for transport The figures show examples of threaded connections and connection heads. Cable entry Ex d cable gland stainless steel Plain threaded Sealing plugs for shipping Cable entry thread size M20 x 1.5 or ½ NPT M20 x 1.5 or ½ NPT M20 x 1.5 or ½ NPT Cable entry Colour Ingress protection (max.) Min./max. ambient temperature Ex d cable gland stainless steel Blank IP66-60 1) / -40... +80 C Plain threaded - IP00 - Sealing plugs for transport Transparent - -40... +80 C 1) Special version on request (only available with selected approvals), other temperatures on request Ingress protection to IP66 per IEC/EN 60529 under the following conditions: Use of a suitable cable gland Use of a cable cross-section appropriate for the gland or select the appropriate cable gland for the available cable Adhere to the tightening torques for all threaded connections Transmitter Mounting onto the measuring insert With mounting on the measuring insert, the transmitter replaces the terminal block and is fixed directly to the terminal plate of the measuring insert. Measuring insert with mounted transmitter (here: model T32) Measuring insert prepared for transmitter mounting Page 5 of 12

Transmitter models Output signal 4... 20 ma, HART protocol, FOUNDATION Fieldbus and PROFIBUS PA Transmitter (selectable versions) Model T16 Model T32 Model T53 Data sheet TE 16.01 TE 32.04 TE 53.01 Output 4... 20 ma x x HART protocol x FOUNDATION Fieldbus and PROFIBUS PA x Input Thermocouples IEC 60584-1 K, J, E, N, T K, J, E, N, T K, J, E, N, T Explosion protection Optional Optional Standard Possible mounting positions for transmitters Connection head T16 T32 T53 1/4000 F, 1/4000 S 7/8000 W, 7/8000 S 7/8000 W / DIH50, 7/8000 S / DIH50 - Mounted instead of terminal block Mounting not possible The mounting of a transmitter on the measuring insert is possible with all the connection heads listed here. The fitting of a transmitter in the (screw) cap of a North American design connection head is not possible. Mounting of 2 transmitters on request. For a correct determination of the overall measuring deviation, the sensor and transmitter measuring deviations must be added. Functional safety (option) with temperature transmitter model T32 In safety-critical applications, the entire measuring chain must be taken into consideration in terms of the safety parameters. The SIL classification allows the assessment of the risk reduction achieved by the safety installations. Selected TC10-L thermocouples, in combination with a suitable temperature transmitter (e.g. model T32.1S, TÜV certified SIL version for protection systems developed in accordance with IEC 61508), are suitable as sensors for safety functions to SIL 2. For detailed specifications, see Technical information IN 00.19 at www.wika.com. Page 6 of 12

Components model TC10-L Nipple-union-nipple neck tube Double threaded hex bushing (tube section) Double threaded hex bushing (with hexagonal spanner flats) 3112287.03 3112147.04 Neck tube with counter nut to head Legend: Connection head Neck tube Connection to thermowell Measuring insert Transmitter (option) Flame path fitting A (l 1 ) Insertion length (with parallel threads) A (U 2 ) Insertion length (with tapered threads) l 5 Measuring insert length Ø d Measuring insert diameter NL Nominal length N (M H ) Neck length Page 7 of 12

Neck tube Neck tube designs Nipple-union-nipple neck tube Double threaded hex bushing (tube section) 3116003.01 14235871.01 Thread Thread Double threaded hex bushing (with hexagonal spanner flats) Neck tube with counter nut to head 14235871.01 3115995.01 Thread Thread Legend: A (l 1 ) Insertion length (with parallel threads) A (U 2 ) Insertion length (with tapered threads) N (M H ) Neck length Ø d K E Measuring insert diameter Screw-in length by hand - with ½ NPT approx. 8.1 mm - with ¾ NPT approx. 8.6 mm Page 8 of 12

Neck tube versions Neck tube design Diameter Connection to head Connection to thermowell Material Nipple-union-nipple neck tube ~ 22 mm ½ NPT Mounting thread 316 Double threaded hex bushing (tube section) Double threaded hex bushing (with hexagonal spanner flats) ~ 27 mm ¾ NPT ~ 22 mm ½ NPT Mounting thread 316 ~ 27 mm ¾ NPT - M24 x 1.5 / ½ NPT Mounting thread 1.4571 Neck tube with counter nut to head 14 x 2.5 mm M20 x 1.5 (with counter nut) Mounting thread 1.4571 Thread sizes Neck tube design Diameter Thread to the thermowell Nipple-union-nipple neck tube ~ 22 mm ½ NPT ~ 27 mm ¾ NPT Double threaded hex bushing (tube section) ~ 22 mm ½ NPT ~ 27 mm ¾ NPT Double threaded hex bushing (with hexagonal spanner flats) - G ½ B G ¾ B G ¼ B ½ NPT ¾ NPT M14 x 1.5 M18 x 1.5 M20 x 1.5 Neck tube with counter nut to head 14 x 2.5 mm ½ NPT ¾ NPT G ½ B G ¾ B G ¼ B M14 x 1.5 M18 x 1.5 M20 x 1.5 Neck lengths Neck tube design Neck length Min. / Max. neck length Nipple-union-nipple neck tube 150 mm (approx. 6 inch) 75 mm (approx. 3 inch) / 250 mm (approx. 10 inch) Double threaded hex bushing (tube section) 50 mm (approx. 2 inch) 50 mm (approx. 2 inch) / 250 mm (approx. 10 inch) Double threaded hex bushing (with hexagonal 25 mm spanner flats) Neck tube with counter nut to head 150 mm (approx. 6 inch) 75 mm (approx. 3 inch) / 250 mm (approx. 10 inch) The neck tube is screwed into the connection head. The neck length depends on the intended use. Usually an isolation is bridged by the neck tube. Also, in many cases, the neck tube serves as a cooling extension between the connection head and the medium, in order to protect a possible built-in transmitter from high medium temperatures. Other versions on request Page 9 of 12

Measuring insert Within the TC10-L, the measuring insert of model TC10-K is fitted. The replaceable measuring insert is made of a vibration-resistant, sheathed measuring cable (MI cable). Pay special attention to the assembly/disassembly of the measuring insert. The surface of the sheathed cable of the measuring insert must not be damaged! (No creases, grooves, scratches etc.). Any damaged measuring insert must be replaced. It is advisable to renew the corresponding flame path fitting in this case. Attention: Only correct measuring insert length and correct measuring insert diameter ensure sufficient heat transfer from thermowell to the measuring insert. The bore diameter of the thermowell should be a max. 1 mm larger than the measuring insert diameter. Gaps of more than 0.5 mm between thermowell and the measuring insert will have a negative effect on the heat transfer, and they will result in unfavourable response behaviour of the thermometer. When fitting the measuring insert into a thermowell, it is very important to determine the correct insertion length (= thermowell length for bottom thicknesses of 5.5 mm). In order to ensure that the measuring insert is firmly pressed down onto the bottom of the thermowell, the measuring insert must be spring-loaded (spring travel: max. 10 mm). Dimensions in mm Spring-loaded screw Insulation washer Terminal plate Connection terminal Design prepared for transmitter mounting Design with mounted transmitter Measuring insert with sleeve in the sensor area 11449307.03 Legend: A (l 5 ) Measuring insert length Ø d Measuring insert diameter * Ø 45 mm with 2 x Pt100 in 4-wire connection Measuring insert diameter Ø d in mm Sheath material 3 1) 1.4571, 316L 1) 6 1.4571, 316L 1) 8 (6 mm with sleeve) 1.4571 1) Not possible with 2 x 4-wire versions Page 10 of 12

Thermowell selection TW10 TW15 TW20 TW25 TW30 TW45 Data sheets: TW 95.10 TW 95.11 TW 95.12 TW 95.15 TW 95.20 TW 95.25 TW 95.30 TW 95.45 TW50 TW55 TW 95.50 TW 95.55 Special thermowells on request Page 11 of 12

Operating conditions Mechanical requirements Version Standard Option 6 g peak-to-peak, wire-wound measuring resistor or thin film Vibration-resistant probe tip, max. 20 g peak-to-peak, thin-film measuring resistor Highly vibration-resistant probe tip, max. 50 g peak-to-peak, thin-film measuring resistor The information on vibration resistance refers to the tip of the measuring insert. For detailed specifications on the vibration resistance of Pt100 sensors, see Technical information IN 00.17 at www.wika.com. Ambient and storage temperature -60 1) / -40... +80 C 1) Special version on request (only available with specific approvals) Other ambient and storage temperatures on request Certificates Certification type Measurement accuracy 2.2 test report x x 3.1 inspection certificate x x DKD/DAkkS calibration certificate x - Material certificate 2) The different certifications can be combined with each other. 2) Thermowells have their own material certificates Ordering information Model / Explosion protection / Process connection / Version and material of threaded connection / Thread size / Measuring element / Connection method / Temperature range / Probe diameter / Insertion length A / Neck length N(M H ) / Certificates / Options 09/2003 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. 07/2018 EN Page 12 of 12 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de