Thermocouple Model TC10-H without thermowell

Similar documents
Thermocouple with spring-loaded tip Model TC55

Thermocouple Without thermowell Model TC10-H

Cable thermocouple Model TC40

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Resistance thermometer Without thermowell Model TR10-H

Tubeskin thermocouple assembly Model TC59-V

Tubeskin thermocouple assembly Model TC59-W

Cable resistance thermometer Model TR40

Tubeskin thermocouple assembly Model TC59-V

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Cable thermocouple Model TC40

Resistance thermometer Model TR10-B, for additional thermowell

Cable thermocouple Model TC40

Thermocouple For additional thermowell Model TC10-B

Measuring insert for resistance thermometer Model TR10-A

Thermocouples Model TC10-B, for Additional Thermowell

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Cable resistance thermometer Model TR40

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Cable resistance thermometer Model TR40

Resistance thermometer Model TR10-E, for additional thermowell

Surface thermocouple Model TC50

Thermocouple Model TC10-E, for additional thermowell

Measuring insert for process resistance thermometer

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Thermocouples Model TC10-E, for Additional Thermowell

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

Resistance thermometer For sanitary applications Model TR22-A, exchangeable sensor

High-pressure thermocouple Model TC90

Hot runner thermocouple Model TC46

Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A

Hot Runner Thermocouples Model TC46

Resistance thermometer with digital display Model TR75, battery operation

Bimetal thermometer Model 52, industrial series

Gas-actuated thermometer Highly vibration resistant Model 75, stainless steel version

Resistance thermometer with digital indicator Model TR75, battery operation

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Reed sensor For bypass level indicators Model BLR

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Bimetal thermometer Model 52, industrial series

Compact pressure switch Model PCS

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Compact temperature switch Model TCS

Duct thermometer Model TF40

Mini temperature switch Stainless steel switch enclosure Model TXS

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB

For the plastics machinery industry Manifold thermocouple Model TC47-MT

Compact differential pressure switch Models DC, DCC

Mini pressure switch Stainless steel switch enclosure Model PXS

Differential pressure gauge Model , copper alloy Model , stainless steel version

Gas-actuated thermometer with switch contacts Model 73, stainless steel version

Thermowell For sanitary applications Model TW61, for orbital welding

Thermowell For sanitary applications Model TW61, for orbital welding

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Thermowell For sanitary applications Model TW61, for orbital welding

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG

Screw-in thermometer with connection lead Model TF37

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40TA, with component testing

Bimetal thermometer with Pt100 electrical output signal Model 54, stainless steel version

Pressure gauge per EN with mounted diaphragm seal With threaded connection, threaded design Model DSS10M

Thermowell For sanitary applications Model TW61, for orbital welding

Differential pressure switch Model DPS40

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

High-quality pressure sensor with mounted diaphragm seal With threaded connection, welded design Model DSS34T

High-quality pressure sensor with mounted diaphragm seal With threaded connection, threaded design Model DSS10T

Insertion thermometer With connection lead Model TF45

Gas-actuated thermometer Model 73, stainless steel version

Pressure switch, high adjustability of switch differential

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

Thermocouples TE Measuring Insert. rigid Model TC 001 flexible Model TC 002. Electronic Temperature Measurement

Portable pressure calibrator, Wally Box III Model CPH7600

Mechatronic pressure measurement. Applications. Special features. Description

Differential pressure gauge with switch contacts For the process industry Models DPGS43HP.1x0, high overload safety up to 40, 100, 250 or 400 bar

Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and

Differential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT and DPGT43.160

Temperature multi-function calibrator Model CTM

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Diaphragm seal with threaded connection Plastic version Model

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection

Differential pressure gauge with electrical output signal Model A2G-15

Thermowell For sanitary applications Model TW22

Accessories for diaphragm seals Block flange and saddle flange Models , ,

High-quality pressure sensor with mounted diaphragm seal With clamp connection Model DSS22T

Pressure gauge per EN with mounted diaphragm seal With SMS threaded connection Model DSS19F

Machine glass thermometers Model 32, V-Form

High-quality pressure sensor with mounted diaphragm seal With flange connection, flush diaphragm Model DSS27T

Differential pressure gauge For the process industry Models , , high overload safety up to 40, 100 or 400 bar

Diaphragm seal with sterile connection For homogeniser machines Model

Pressure gauge in hygienic design with mounted diaphragm seal With clamp connection Model DSS22P

Diaphragm pressure gauge, flush For sanitary applications Model PG43SA-S, NS 100

Bourdon tube pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21PB, NS 60, 80 and 100

Transcription:

Electrical temperature measurement Thermocouple Model TC10-H without thermowell WIKA data sheet TE 65.08 for further approvals see page 7 Applications For direct installation in the process Machine building Motors Storage Pipelines and vessels Special features Application ranges from 0... 1,200 C For insertion, screw-in with optional process connection Connection head form B or JS Explosion-protected versions Ex i Thermocouples without thermowell, model TC10-H Description Thermocouples without thermowell are particularly suitable for those applications in which the metallic sensor tip is mounted directly into bored holes (e.g. in machine components) or directly into the process for any application with no chemically aggressive media or abrasion. For mounting into a thermowell, a spring-loaded compression fitting should be provided, since only this can press the sensor tip into the bottom of the thermowell. Otherwise a potentially critical force could be exerted on the measuring tip. Mounting is usually made directly into the process. Fastening elements such as threaded fittings, union nuts, etc. can also be used. The flexible part of the sensor is a mineral-insulated cable (sheathed cable). It consists of a stainless steel outer sheath, which contains the insulated internal leads, embedded within a high-density ceramic compound and is also suitable for use at higher temperatures. Optionally we can fit analogue or digital transmitters from the WIKA range into the connection head. WIKA data sheet TE 65.08 02/2015 Page 1 of 8

Sensor Sensor types Type Recommended max. operating temperature K 1,200 C J 800 C E 800 C T 400 C N 1,200 C Sensor tip designs Measuring point ungrounded Thermocouple Measuring point Measuring point grounded Thermocouple Measuring point Thermocouple Class Type IEC 60584-1:2013 ASTM E230 K 1 and 2 Standard, special J 1 and 2 Standard, special N 1 and 2 - E 1 and 2 - T 1 and 2 - Tolerance value For the tolerance value of thermocouples, a cold junction temperature of 0 C has been taken as the basis. For detailed specifications for thermocouples, see Technical information IN 00.23 at www.wika.com. Listed models are available both as single or dual thermocouples. The thermocouple will be delivered with an insulated measuring point, unless explicitly specified otherwise. The actual application range of these thermometers is limited by the permissible maximum temperature of the thermocouple and of the thermowell material. Sheath Sheath For temperature measurement in a solid body, the diameter of the bore into which the sensor should be inserted, should be no more than 1 mm larger than the sensor diameter. Sheathed thermocouples may be flexed with a radius 3-times of the sheath diameter. Sheath diameter: 3.0 mm 4.5 mm 6.0 mm 8.0 mm Others on request Please note: The flexibility of the sheathed thermocouple must be considered, especially when the flow rates are relatively high. Designs in which the process connection is not located directly at the connection head should be considered critical in applications where vibratory or oscillating stresses occur. Sheath material Ni-alloy 2.4816 (Inconel 600) - up to 1,200 C (air) - standard material for applications which require specific corrosion resistance properties under exposure to high temperatures, resistant to induced stress corrosion cracking and pitting in media containing chloride - resistant to corrosion caused by aqueous ammonia in all temperatures and concentrations - highly resistant to halogens, chlorine, hydrogen chloride Stainless steel - up to 850 C (air) - good corrosion resistance with aggressive media as well as steam and flue gases in chemical media Others on request Permissible ambient temperature -40... +80 C IP protection Standard ingress protection: IP 65 Page 2 of 8 WIKA data sheet TE 65.08 02/2015

Process connections The model TC10-H sheathed thermocouples can be fitted optionally with the process connections shown below. The insertion length A (U 1 or U2) can be customised. The neck length, N (M H ), depends on the type of the process connection selected. To minimise heat dissipation errors via the threaded connection, the insertion length, A, should be at least 25 mm long. The position of the threaded connection is specified by the dimension N (M H ), and is not dependent on the connection type. Please note: - For parallel threads (e.g. G ½) the dimensioning always refers to the sealing collar of the threaded connector nearest the process. - For tapered threads (e.g. NPT) the measurement plane is located approx. in the centre of the thread. Without process connection This version is designed mainly for mounting in one of the available compression fittings. All heads of the size form B and KN can be used. The neck length, N (M H ), in this case only specifies the height of the hexagon on the head of the thermowell. N (M H ) is always 10 mm. Cable gland optional; compulsory for Ex n 11360224.01 Without process connection (miniature version) This version is designed mainly for mounting in one of the available compression fittings. Only connection heads of the JS design can be used. The neck length, N (M H ), in this case only specifies the height of the hexagon on the head of the thermowell. N (M H ) is always 7 mm. 11360216.01 WIKA data sheet TE 65.08 02/2015 Page 3 of 8

Protruded fixed thread This version is used for the mounting of thermometers into threaded couplings with female threads. Insertion length A: to customer specification Material: stainless steel, others on request 11360232.01 The sensor must be rotated in order to screw it into the process. Therefore, this design must first be mounted mechanically and it can then be electrically connected. Thread Thread (NPT) Compression fitting This version allows simple adjustment to the required insertion length at the installation point. Since the compression fitting is movable on the sensor, the A and N (M H ) dimensions define the as-delivered condition. The length of the compression fitting determines the smallest possible neck length, N (M H ), of approx. 40 mm. 11360241.01 Material: stainless steel Sealing ring material: stainless steel or PTFE Stainless steel sealing rings can be adjusted once; once they have been unscrewed, sliding along the sheath is no longer possible. Max. temperature at process connection 500 C Max. pressure load 40 bar PTFE sealing rings can be adjusted several times, after unscrewing, repeated sliding along the sheath is still possible. Max. temperature at process connection 150 C Max. pressure load 25 bar For sheathed resistance thermometers with a Ø of 2 mm, only PTFE sealing rings are approved. Thread Thread (NPT) Page 4 of 8 WIKA data sheet TE 65.08 02/2015

Spring-loaded compression fitting This version allows easy adjustment to the desired mounting length at the mounting point, while at the same time sustaining the spring pre-tension. Since the compression fitting is movable on the sensor, the A and N (M H ) dimensions define the as-delivered condition. The length of the compression fitting determines the smallest possible neck length N (M H ) of approx. 80 mm. 11360267.01 Material: stainless steel Sealing ring material: stainless steel Stainless steel sealing rings can be adjusted once; once they have been unscrewed, sliding along the sheath is no longer possible. Max. temperature at process connection 500 C Pressure load is not provided for Thread Thread (NPT) Spring-loaded compression fitting, can work with pressures up to max. 8 bar allows easy adjustment to the desired insertion length at the mounting point, while at the same time maintaining the spring pre-tension, intended for use with hydraulic oil 14121593.01 Since the compression fitting is movable on the sensor, the A and N (M H ) dimensions define the as-delivered condition. The length of the compression fitting determines the smallest possible neck length N (M H ) of approx. 80 mm. Material: stainless steel Ferrule material: stainless steel Stainless steel ferrules can be adjusted once; once they have been unscrewed, sliding along the sheath is no longer possible. Permissible temperature at process connection -30... +100 C A pressure load on the spring-loaded compression fitting is permissible up to a max. 8 bar. Double nipple version Using a double-sided threaded nipple, the thermometer can be screwed directly into the process. In this case the permissible temperature ranges must be observed. The neck length, N (M H ), for parallel threads depends on the height of the hexagon. This is 10 mm. The neck length, N (M H ), of NPT threads not only includes the hexagon height but also half of the thread height. This gives us a neck length, N (M H ), of approx. 19 mm. Thread Thread (NPT) 11360372.01 WIKA data sheet TE 65.08 02/2015 Page 5 of 8

Connection head JS Type Material Cable outlet Ingress protection Cap Surface JS Aluminium M16 x 1.5 1) IP 65 Cap with 2 screws Blue, lacquered 2) BS Aluminium M20 x 1.5 1) IP 65 Cap with 2 screws Blue, lacquered 2) BSZ Aluminium M20 x 1.5 1) IP 65 Hinged cover with cylinder head screw Blue, lacquered 2) BSZ-K Plastic M20 x 1.5 1) IP 65 Hinged cover with cylinder head screw Black BSZ-H Aluminium M20 x 1.5 1) IP 65 Hinged cover with cylinder head screw Blue, lacquered 2) BSZ-HK Plastic M20 x 1.5 1) IP 65 Hinged cover with cylinder head screw Black BSS Aluminium M20 x 1.5 1) IP 65 Hinged cover with clip Blue, lacquered 2) BSS-H Aluminium M20 x 1.5 1) IP 65 Hinged cover with clip Blue, lacquered 2) BVS Stainless steel M20 x 1.5 1) IP 65 Screw cap Precision casting, electropolished 1) Standard 2) RAL 5022 BS BSZ, BSZ-K BSZ-H, BSZ-HK BSS BSS-H BVS Connection head with digital indicator (option) As an alternative to the standard connection head the thermometer can be fitted with an optional DIH10 digital indicator. The connection head used for this is similar to the model BSZ-H head. For operation, a 4... 20 ma transmitter is needed, which is mounted to the measuring insert. The indication range is configured identically to the measuring range of the transmitter. Designs with ignition protection type intrinsically safe, Ex i (gas), are also available. For the fixed protruded thread and double nipple versions, final orientation cannot be predicted when screwing the connection head on. Therefore, the alignment of the digital indicator cannot be predefined. In order to ensure safe readability of the display the DIH10 can only be delivered with the following ordering options: with compression fitting without process connection Connection head with digital indicator, model DIH10 Transmitter (option) Depending on the connection head used, a transmitter can be mounted within the thermometer. Mounted instead of terminal block Mounted within the cap of the connection head Mounting not possible Mounting of 2 transmitters on request. Connection head Transmitter model T12 T32 T53 T91.20 JS - - BS - - - BSZ / BSZ-K - BSZ-H / BSZ-HK - BSS - BSS-H - BVS - Type Description Explosion protection Data sheet T91.20 Analogue transmitter, fixed measuring range Without TE 91.01 T12 Digital transmitter, PC configurable Optional TE 12.03 T32 Digital transmitter, HART protocol Optional TE 32.04 T53 Digital transmitter FOUNDATION Fieldbus and PROFIBUS PA Standard TE 53.01 Page 6 of 8 WIKA data sheet TE 65.08 02/2015

Electrical connection Single thermocouple Dual thermocouple The colour coding at the positive poles of the instrument decides the correlation of polarity and connection terminal. 3166822.03 For the electrical connections of built-in temperature transmitters see the corresponding data sheets or operating instructions. Explosion protection (optional) Thermocouples of the TC10-H series are available with an EC-type examination certificate for intrinsically safe, Ex i, ignition protection. These instruments comply with the requirements of 94/9/EC (ATEX) directive for gas and dust. The classification/suitability of the instrument (permissible power P max as well as the permissible ambient temperature) for the respective category can be seen on the EC-type examination certificate and in the operating instructions. Built-in transmitters have their own EC-type examination certificate. The permissible ambient temperature ranges of the built-in transmitters can be taken from the corresponding transmitter approval. The system operator is responsible for using suitable thermowells. CE conformity EMC directive 1) 2004/108/EC, EN 61326 emission (group 1, class B) and interference immunity (industrial application) ATEX directive (option) 94/9/EC, EN 60079-0, EN 60079-11, EN 60079-26, EN 61241-11 1) Only for built-in transmitter Approvals (option) IECEx, ignition protection type i - intrinsic safety, ignition protection type id - dust protection through intrinsic safety, international certification for the Ex area NEPSI, ignition protection type i - intrinsic safety, ignition protection type id - dust protection through intrinsic safety, ignition protection type n, China EAC, import certificate, ignition protection type i - intrinsic safety, ignition protection type id - dust protection through intrinsic safety, ignition protection type n, customs union Russia/Belarus/Kazakhstan GOST, metrology/measurement technology, Russia INMETRO, Institute of Metrology, ignition protection type i - intrinsic safety, ignition protection type id - dust protection through intrinsic safety, Brazil KOSHA, ignition protection type i - intrinsic safety, ignition protection type id - dust protection through intrinsic safety, South Korea PESO (CCOE), ignition protection type i - intrinsic safety, ignition protection type id - dust protection through intrinsic safety, India Certificates (option) Certification type Measuring accuracy 2.2 test report x x 3.1 inspection certificate x x DKD/DAkkS calibration certificate x - Material certificate The different certifications can be combined with each other. Approvals and certificates, see website WIKA data sheet TE 65.08 02/2015 Page 7 of 8

Ordering information Model / Explosion protection / Connection head / Cable outlet / Terminal block, transmitter / Version of the threaded connection / Measuring element / Temperature range / Sensor diameter / Materials / Thread size / Neck length / Insertion length / Certificates / Options 2008 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 8 of 8 WIKA data sheet TE 65.08 02/2015 02/2015 EN WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de