Experimental Study of Heat Transfer Augmentation in Concentric Tube Heat Exchanger with Different Twist Ratio of Perforated Twisted Tape Inserts

Similar documents
Heat Transfer Enhancement for Double Pipe Heat Exchanger Using Twisted Wire Brush Inserts

Visualization of Flow and Heat Transfer in Tube with Twisted Tape Consisting of Alternate Axis

NOVATEUR PUBLICATIONS INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT] VOLUME 1, ISSUE 1 NOV-2014

Enhance the Performance of Heat Exchanger with Twisted Tape Insert: A Review

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October ISSN

An Experimental Study of Thermo-Hydraulic Performance of Modified Double Pipe Heat Exchanger Using Mesh Inserts

An Approach for Enhancement of Heat Transfer Using Conical Convergent Ring Inserts In Tube

HEAT TRANSFER ENHANCEMENT BY V-NOZZLE TURBULATORS

EFFECT OF EXTERNAL THREADED INSIDE TUBE ON HEAT TRANSFER RATE IN A CONCENTRIC TUBE HEAT EXCHANGER: A CRITICAL REVIEW

HEAT TRANSFER ENHANCEMENT BY USING TWISTED TAPE INSERTS WITH CIRCULAR HOLES IN FORCED CONVECTION

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

HEAT TRANSFER ENHANCEMENT IN A CIRCULAR TUBE FOR TURBULENT FLOW OF WATER USING PERFORATED RECTANGULAR STRIPE INSERT

Department of Mechanical Engineering, D Y Patil College of Engineering, Akurdi, Pune , Savitribai Phule Pune University, India

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

CFD Analysis of Double Pipe Heat Exchanger with Twisted Tape Insert in Inner Pipe

ABSTRACT I. INTRODUCTION III. GEOMETRIC MODELING II. LITERATURE REVIW

EXPERIMENTAL INVESTIGATIONS OF DOUBLE PIPE HEAT EXCHANGER WITH TRIANGULAR BAFFLES

International Journal of Advance Engineering and Research Development

ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR AND NANOFLUID

Comparison of Heat transfer Enhancement in Tube in Tube heat exchanger using Different Turbulent Generator.

Analysis to Determine Heat Transfer Using Twisted Tape Inserts In a Horizontal Tube

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Experimental Investigation on Turbulent Flow Heat Transfer in a Horizontal Circular Pipe using Coil and Twisted Tape Inserts

Simulation Studies on the Effect of Porous Twisted Plate Inserts on the Performance of Fire Tube Steam Packaged Boiler

Experimental Study of Heat Transfer Enhancement in a Heated tube Caused by Wire-Coil and Rings

Experimental Investigation of Heat Transfer characteristics Enhancement through Grooved Tube

Numerical Investigation of Convective Heat Transfer and Pressure Loss in a Round tube Fitted with Circular-Ring Turbulators

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March ISSN

Thermal Stress Analysis of Diesel Engine Piston

SINGLE-PHASE CONVECTIVE HEAT TRANSFER AND PRESSURE DROP COEFFICIENTS IN CONCENTRIC ANNULI

THERMAL ANALYSIS OF HELICALLY GROOVED COIL IN A CONCENTRIC TUBE HEAT EXCHANGER

AUGMENTATION OF TURBULENT FLOW HEAT TRANSFER IN A HORIZONTAL TUBE WITH VARYING WIDTH TWISTED TAPE INSERTS

Heat Transfer in Rectangular Duct with Inserts of Triangular Duct Plate Fin Array

PERFORMANCE ANALYSIS ON DOUBLE PIPE HEAT EXCHANGER USING WIRE COILED AND PIN WIRE COILED TURBULATOR INSERTS

Experimental Analysis of Heat Transfer and Friction Factor Characteristics in Turbulent Flow through a Tube Fitted with Screw Tape

Heat Transfer Augmentation Technique Using Twisted Tape Insert

A REVIEW ON INVESTIGATION OF HELICAL COIL HEAT EXCHANGER

A Review on Experimental Investigation of U-Tube Heat Exchanger using Plain Tube and Corrugated Tube

Design and experimental analysis of pipe in pipe heat exchanger

Numerical and Experimental Investigations of Heat Transfer in Double Pipe Heat Exchangers with Inner and Annular Twisted Tape

TEMPERATURE APPROACH OPTIMIZATION IN THE DOUBLE PIPE HEAT EXCHANGER WITH GROOVE

Review on Comparative Study between Straight Tube Heat Exchanger and Helical Coil Heat Exchanger

Heat Transfer Enhancement In Pipe With Passive Enhancement Technique

Prediction of Thermal Deflection at Spindle Nose-tool Holder Interface in HSM

Heat transfer enhancement of a single row of tube

CONJUGATE HEAT TRANSFER ANALYSIS OF HELICAL COIL HEAT EXCHANGE USING CFD

Experimental Study on Heat Enhancement of Helixchanger with Grooved Tubes

International Journal of Engineering Research and General Science Volume 5, Issue 3, May-June, 2017 ISSN

ENHANCEMENT OF HEAT TRANSFER COEFFICIENT THROUGH HELICAL COIL

CFD analysis of heat transfer enhancement in helical coil heat exchanger by varying helix angle

Chapter 7: Thermal Study of Transmission Gearbox

Flow Characteristics of Air in Square Channel Using Perforated Ribs

GEOMETRICAL PARAMETERS BASED OPTIMIZATION OF HEAT TRANSFER RATE IN DOUBLE PIPE HEAT EXCHANGER USING TAGUCHI METHOD D.

Modeling and Fluid Flow Analysis of Wavy Fin Based Automotive Radiator

Enhanced Heat Transfer Surface Development for Exterior Tube Surfaces

Design, Fabrication and Testing of helical tube in tube coil heat exachanger

Experimental investigation of shell-and-tube heat exchanger with different type of baffles

Effect of Nanofluid on Friction Factor of Pipe and Pipe Fittings: Part I - Effect of Aluminum Oxide Nanofluid

CFD Analysis and Comparison of Fluid Flow Through A Single Hole And Multi Hole Orifice Plate

CFD ANALYSIS ON LOUVERED FIN

Abstract In this study the heat transfer characteristics inside a rectangular duct with circular, rectangular, drop

Design and Performance Analysis of Louvered Fin Automotive Radiator using CAE Tools

EXPERIMENTAL ANALYSIS AND PERFORMANCE CHARACTERISTIC OF HEAT TRANSFER IN SHELL AND TWISTED TUBE HEAT EXCHANGER

NUMERICAL INVESTIGATION OF PISTON COOLING USING SINGLE CIRCULAR OIL JET IMPINGEMENT

SWIRL MEASURING EQUIPMENT FOR DIRECT INJECTION DIESEL ENGINE

COMPUTATIONAL ANALYSIS TO MAXIMIZE THE HEAT TRANSFER RATE OF DOUBLE TUBE HELICAL COIL HEAT EXCHANGER

FLOW AND HEAT TRANSFER ENHANCEMENT AROUND STAGGERED TUBES USING RECTANGULAR VORTEX GENERATORS

Experimental Analysis and Performance Characteristic Of Heat Transfer In Shell and Twisted Tube Heat Exchanger.

An Experimental Investigation for the Rate of Heat Transfer in Double Pipe Heat Exchanger with Fins on Inside Surface of Internal Tube

CFD analysis of triple concentric tube heat exchanger

CRITICAL ASSESSMENT OF LITERATURE IN THE FIELD OF ENHANCED HEAT TRANSFER TECHNIQUES

Numerical Investigation of the Effect of Excess Air and Thermal Power Variation in a Liquid Fuelled Boiler

Research Article Thermohydraulic Analysis of Shell-and-Tube Heat Exchanger with Segmental Baffles

Forced Convection Heat Transfer Analysis through Dimpled Surfaces with Different Arrangements

Efficiency Improvement in Shell and Tube Heat Exchanger Using CFD Tool

ADVANCES in NATURAL and APPLIED SCIENCES

International Research Journal of Engineering and Technology (IRJET) e-issn:

HEAT TRANSFER AUGMENTATION OF LAMINAR NANOFLUID FLOW IN HORIZONTAL TUBE INSERTED WITH TWISTED TAPES

Effects of Dilution Flow Balance and Double-wall Liner on NOx Emission in Aircraft Gas Turbine Engine Combustors

Effect of Helix Parameter Modification on Flow Characteristics of CIDI Diesel Engine Helical Intake Port

Study on Flow Fields in Variable Area Nozzles for Radial Turbines

A Study on Performance Enhancement of Heat Exchanger in Thermoelectric Generator using CFD

CFD Analysis of Heat Transfer Prediction for Corrugated Shell & Tube Heat Exchanger

Effect of Stator Shape on the Performance of Torque Converter

Load Analysis and Multi Body Dynamics Analysis of Connecting Rod in Single Cylinder 4 Stroke Engine

EFFECT OF SURFACE ROUGHNESS ON PERFORMANCE OF WIND TURBINE

Effect of Wavy Tube on Heat Transfer in a Concentric Tube Heat Exchanger: A Review

INVESTIGATION OF HEAT TRANSFER CHARACTERISTICS OF CIRCULAR AND DIAMOND PILLARED VANE DISC BRAKE ROTOR USING CFD

Experimental Investigation on Mixing time Analysis of Jet Mixer

Optimization of Seat Displacement and Settling Time of Quarter Car Model Vehicle Dynamic System Subjected to Speed Bump

Optimisation of Double Pipe Helical Tube Heat Exchanger and its Comparison with Straight Double Tube Heat Exchanger

Exhaust Waste Heat Recovery of I. C. Engine by Thermoelectric Generator

International Journal of Advance Engineering and Research Development

FLUID FLOW. Introduction

Heat transfer and friction characteristics of rotor-assembled strand heat exchanger studied by uniform design experiment

Experimental Study of Heat Transfer Enhancement in Tube in Tube Heat Exchanger using Rectangular Wing Type Vortex Generator

Use of Flow Network Modeling for the Design of an Intricate Cooling Manifold

e t Performance of Extended Inlet and Extended Outlet Tube on Single Expansion Chamber for Noise Reduction

Computational Investigation of Normal and Hybrid Cooling Fins of Internal Combustion Engine

Flow Behavior and Friction Factor. in Internally Grooved Pipe Wall

Transcription:

International search Journal of Advanced Engineering and Science Experimental Study of Heat Transfer Augmentation in Concentric Tube Heat Exchanger with Different Twist Ratio of Perforated Twisted Tape Inserts Ganesh Kumar 1, Parmanand Kumar 2, Ramesh Murmu 3, Sandip Kumar 4 1 PG Scholar Dept. of Mechanical Engg, N.I.T Jamshedpur 2 Associate Professor Dept. of Mechanical Engg, N.I.T Jamshedpur 3 search Scholar Dept. of Mechanical Engg, N.I.T Jamshedpur 4 PG Scholar Energy System Engg, N.I.T Jamshedpur Abstract In this study an experimental investigation has been carried out for heat transfer and pressure drop characteristics in a concentric double tube heat exchanger using perforated twisted (PT) tape inserts in inner tube of various twist ratio. The experiment was perform with perforated tape of two different twist ratio (p/w= 3, 4) and fixed axial pitch ratio (s x /w=25) and constant hole diameter ratio (d/w=0.208). The experiments were performed in counter flow manner of the fluid cold water flow in inner tube and hot water flow in annulus part. In this experiment ynolds number varies from 1900 to 5200. For comparison experiments were also performed with typically twisted (TT) tape and plane tube. The experimental result shows that heat transfer rate and friction factor of plane tube and with TT tape insert. The result shows that nusselt number increases with decrease in twist ratio (p/w). PT inserts with p/w=3 and 4, provides nusselt number up to 26% and 14% higher than plane tube respectively, 10% and 8% higher than typically twisted tape respectively. In inner tube an average friction factor generated by PT tape with twist ratio d/w=3 and 4 is found up to 207% and 87% more than plane tube respectively, 46% and 38% more than TT tape respectively. The empirical correlation of nusselt number and friction factor are also developed by experimental results. Keywords Perforated twisted tape, pitch, twist ratio, space ratio, free space introduction. I. INTRODUCTION It has been commonly known that the performance of heat exchangers, for single-phase flow can be improved by many augmentation techniques in general, heat transfer enhancement technique can be divided into two groups, namely active and passive techniques. The active technique requires extra external power source. The other is passive technique, which requires no direct employment of the external power. Heat transfer enhancement technology has been developed and widely applied to heat exchanger applications; for example, refrigeration, automotive, chemical process industry and so on. Among various techniques, insertion of twisted tapes is one of the most promising techniques, which has been widely adopted for heat transfer augmentation. Tube with twisted tape insert is frequently used in heat exchanger systems because of it low cost, less maintenance and compact. But the increase in friction factor is seemed to be the punishment of this technique. Optimization of the twisted tape design is therefore a challenging assignment to meet the requirement of satisfactory heat transfer enhancement with the acceptable friction increase. S. S. Giri, Dr. V. M. Kriplani [1] have been done their effort to increase the heat transfer characteristic using inserts in the tube. Panida Seemawute, Smith Eiamsa- Ard [2] have been worked on visualization of flow and heat transfer in tube with twisted tape consisting of alternate axis. S. K. Saha, A. Dutta, S. K. Dhal [3] have been given their effort to study on heat transfer characteristics and friction factor of laminar swirl flow through a circular tube fitted with regularly spaced twisted-tape elements. Some modified twisted tapes were designed to minimize pressure loss [3 8]. But all modified twisted tapes mentioned above generated lower pressure drop than TT tape inserts, they give significantly lower heat transfer rate, so overall heat transfer performance is decreases. It happens because of lower swirl intensity due to modified twisted tape. Ferroni et al. [9] reported the experimental data for investigated physically separated, multiple, short length twisted tapes. It was observed that pressure drops at least % lower than that of full length twisted tape. Smith et al. [10, 11] done experiment on helical screw tape with and without core-rod inserts and with alternate clockwise and counter-clockwise arrangement. The heat transfer rate gained by using the tape without core -rod is better than that by one with core-rod. In this my experiment, I have made modification on PT tape. Holes are made in the middle of the twisted tape due to this more turbulence is generated in the tube. Therefore, in the present study, the effects of PT tape inserts on heat transfer performance with corresponding increase in friction factor through a concentric double pipe heat exchanger with different twist ratio of PT tape are experimentally investigated. The empirical correlations are developed for predicting the heat transfer, friction. Laminar Flow: the flow of a fluid when each particle of the fluid follows a smooth path, paths which never interfere with one another. One result of laminar flow is that the velocity of the fluid is constant at any point in the fluid. 22 tube heat exchanger with different twist ratio of perforated twisted tape inserts, International search Journal of Advanced Engineering

International search Journal of Advanced Engineering and Science Turbulent Flow: irregular flow that is characterized by tiny whirlpool regions. The velocity of this fluid is definitely not constant at every point. II. Fig. 1. Laminar and turbulent flow. EXPERIMENTAL SETUP AND PROCEDURE exchanger are: di = 28 mm, do = 32 mm, Di =42 mm, and Lo = 10 mm. Cold water was passed through the inner pipe, while hot water was flowing through the annulus. In this experimental effort, it is intended to search for the changes in the convection heat transfer coefficients of the inner pipe side in turbulent flow producing by PT tape. For this purpose, the PT tape insert was installed on the inner pipe side of the concentric double pipe heat exchanger as a swirl generator. For comparison, in this study also tested inner pipe without insert (plain tube) and with TT tape insert. The inlet and outlet temperatures of the hot water and cold water measures with the help of K-type thermocouples. The temperatures were read by using a multi-channel digital thermometer. Pressure loss of the inner pipe side was determined by using U-tube manometer that was filled with water. The inlet temperature at the hot water side was kept constant at 56 and cold water side was ambient temperature at 29. The hot water constantly flowed at 0.142 kg/s whereas the hot water flow rate was adjusted Fig. 3. Photographic view of experimental setup. Fig. 2. Schematic diagram of experimental setup. A schematic diagram of the experimental setup is shown in Fig. 1. This schematic diagram consists of a test section, hot water loop, cold water loop and data measurement system. The test section is the horizontal double pipes heat exchanger with twisted tape insert. The test section designed such that inserts can be changed easily. In addition to the loop component, a full set of instruments for measuring and control of temperature and flow rate of all fluids is installed at all important points in the circuit. The test section made from the straight cupper pipe consists of an outer pipe and inner pipe. The dimensions of the inner and outer pipes of the heat Fig. 4. Perforated twisted tape. Fig. 5. Perforated and typically Twisted tapes. 23 tube heat exchanger with different twist ratio of perforated twisted tape inserts, International search Journal of Advanced Engineering

International search Journal of Advanced Engineering and Science Twisted tape insert was made from aluminum strip with a thickness of 1 mm, a width of 24 mm and the length of 10 mm. Twisted tape insert was fabricated by twisting a straight strip, about its longitudinal axis of different pitch length of y = 76 and 96 mm and tape-twist ratio of 3 and 4. So PT tape insert have two different twist ratio. PT tape inserts were the modified from the TT tape by drilling the small holes with hole diameters of 5 mm along the tape longitudinal axis with fixed axial pitch lengths of Sx = 15 mm and constant values of perforation hole diameter ratio 0.208. Rotameter- Two rotameters are used for measuring discharge of water, one for hot water and one for cold water. Thermocouples- Four thermocouples are used for measuring inlet and outlet temperature of water. Water pump- Two water pumps are used one for hot water and one for cold water. Manometer- Manometer is use for measuring the pressure difference between inlet and outlet of cold fluid in terms of water head. Test section- Concentric tube part is called test section, where cold water flow in inner tube and hot water flow in annulus. Twisted tape is inserted in inner tube. Electric heater- Electric heater used for making hot water, which is supply in test section. Control panel- Control panel is use where all readings are shown, pumps and electric heaters are control. Working fluid- Working fluid water is used in both section. III. DATA REDUCTION The experimental data taken at steady state condition were used to calculate the Nusselt number, friction factor at different ynolds number in turbulent flow region in the inner pipe side for the cases plain tube, with using TT tape insert and PT tape inserts. Mass flow rate is calculated by =ρ*q, where Q is discharge which can be obtained by rotameter Velocity of water V= Heat supplied by hot water is calculated by = ( - ) Heat gained by cold water is calculated by = ( - ) Now average heat transfer = Nusselt number can be calculated by Nu= =, Friction factor f is calculated by f= Now theoretical Nusselt number is obtained by Nu=.023*, where = and Where all the properties are calculated at bulk mean temperature ( ) =, IV. UNCERTAINTY IN MEASUREMENTS Uncertainty is determined by an analyzing the measured data. The uncertainty in the measurement of the pressure drop, flow rate in the tube, friction factor and ynolds number are calculated from kline and McClintock equation. The uncertainties of flow rate, pressure and temperature measurement are estimated to ±2.5%, ± 2% and ± 0.5% respectively. The maximum uncertainty in the ynolds number, friction factor and Nusselt number are found as ± 4.8%, ± 6.5% and ± 8.4%. V. RESULTS AND DISSCUSSION Variation of Friction Factor with ynolds Number f 1.0 0.8 0.2 plain twisted perforated 0.0 Fig. 6. Variation of friction factor for twist ratio 3. = - (w*t), p= +2*(t+w) 24 tube heat exchanger with different twist ratio of perforated twisted tape inserts, International search Journal of Advanced Engineering

International search Journal of Advanced Engineering and Science 0.5 PLAIN CONDITION TWISTED TAPE PERFORATED TAPE PLAIN CONDITION TWISTED TAPE PERFORATED TAPE f 0.3 Nu 0.2 0.1 0.0 Fig. 7. Variation of friction factor for twist ratio 4. As we decreases twist ratio the friction factor is increses because more restiction is produces in flow and larger area comes in contact of water in case of lower twist ratio, So higher friction factor is obtained in twist ratio3. Variation of Nusselt factor with ynolds number Nu plain tube twisted tape perforated tape 30 Fig. 8. Variation of Nusselt number with ynolds number for twist ratio 3. 30 Fig. 9. Variation of Nusselt number with ynolds number for twist ratio 4. Variation in Nusselt number with ynolds number in case of twist ratio 3 is higher than twist ratio 4 because more turbulence and longer path travelled by water in case of twist ratio 3. Hence heat transfer is higher in case of twist ratio 3 than twist ratio 4. Effect of twist ratio on heat transfer coefficient- The influences of the twist ratios (P/W = 3and 4) on the heat transfer enhancement in terms of average Nusselt number in the inner pipe is displayed in Fig. It is seen that the Nusselt number rises with increasing ynolds number for all cases. This show to the increase of turbulent intensity as the ynolds number is increases. Which led to an amplification of convective heat transfer. The influence of using the PT tape inserts at various twist ratios on heat transfer rate is significant for all the ynolds number. As expected from Fig. The Nusselt number obtained from the inner pipe with PT tape insert is significantly higher than those of the plain tube and the TT tape inserts. The PT tape inserts with twist ratios of 3 and 4, enhance heat transfer rate in a range of 26% and 14% above the plain tube, respectively. At the same ynolds number, PT tape inserts consistently provide higher Nusselt numbers than TT tape insert. The better heat transfer offered by PT tape inserts caused by an extra fluid turbulence in the tube due to the presence of holes on the tapes, apart from a common swirl flow. PT tape inserts with P/W = 3 and 4, give Nusselt number up to 10% and 8% higher than TT tape insert, respectively. From the experimental results, it can be revealed that the heat transfer rate also changes with the twist ratio of the PT tape inserts. 25 tube heat exchanger with different twist ratio of perforated twisted tape inserts, International search Journal of Advanced Engineering

f International search Journal of Advanced Engineering and Science Nu 70 plane tube TT, P/W=4 PT, P/W=4 TT, P/W=3 PT, P/W=3 Correlations for prediction of Nusselt number and friction factor- The Nusselt number for the inner pipe fitted with PT tape inserts are correlated as a function of ynolds number, Prandtl number and twist ratio. The friction factor is correlated as a function of ynolds number and twist ratio. The experimental results of the Nusselt number and friction factor for the inner pipe of a concentric tube heat exchanger equipped with PT tape inserts with two different twist ratios 3 and 4 are fitted by the following empirical equations. The goodness of the fit is indicated by the value of correlation coefficient for Nusselt number 0.974 and for friction factor 0.976. 30 Fig. 10. Effect of twist ratio on Nusselt number. Effect of twist ratio on friction factor- Effect of the PT tape inserts with two twist ratios (P/W = 3 and 4) on the pressure drop in terms of friction factor in the inner pipe. The friction factor of the plain tube is also plotted for comparison. For all cases, friction factor decreases with increasing the ynolds number. The increase in friction factor for the inner pipe with the PT tape inserts, is much higher than the plain tube. This is because of the flow blockage, larger contact surface area with longer flow path and the dissipation of dynamic pressure of the fluid due to high viscosity loss near the tube wall. Similar to the results mentioned for Nusselt number, friction factor increases with decreasing the twist ratio of the PT tape inserts. At the same ynolds number, PT tape inserts generate higher flow frictions than TT tape insert. This is because of the extra dissipation of dynamic pressure of the fluid during act caused by the additional fluid disturbance due to the presence of holes on the tapes, resulting in an increase of interaction of the pressure force with inertial force around a velocity boundary layer. An average friction factor in the inner pipe generated by PT tape insert with twist ratios 3 and 4 is found to be around 46% and 38% higher than that induced by TT tape insert respectively. 1.0 0.8 plane tube TT, P/W=4 PT, P/W=4 TT, P/W=3 PT, P/W=3 Predicted results Predicted results 70 70 Experimental results Fig. 12. Comparison between predicted and experimental Nussel number. 1.0 0.9 0.8 0.7 0.5 0.2 0.0 Fig. 11. Effect of twist ratio on Friction factor. 0.3 0.3 0.5 0.7 0.8 0.9 1.0 Experimental results Fig. 13. Comparison between predicted and experimental friction factor. 26 tube heat exchanger with different twist ratio of perforated twisted tape inserts, International search Journal of Advanced Engineering

International search Journal of Advanced Engineering and Science VI. CONCLUSION An experimental study has been done to investigate the heat transfer and friction factor characteristics in a concentric double pipe heat exchanger with different twist ratio of PT tape inserts. The experiments were performed using PT tape inserts with constant axial pitch of 25 and two different twist ratio of 3 and 4 for ynolds number ranging from 1900 to 5200. The experiments using plain tube and the inner tube with TT tape insert were also conducted, for comparison. Based on the obtained results, the conclusion can be drowning as follows. 1. The PT tape inserts gives more heat transfer rate and friction factor compared to that of the plain tube and TT tape insert. 2. At the given ynolds number, heat transfer rate and friction factor increases with decreasing twist ratio. REFERENCES [1] S. S. Giri and Dr. V. M. Kriplani, Heat transfer characteristics using inserts in tubes: A review, International Journal of Engineering search & Technology (IJERT), vol. 3, issue 2, pp. 1033-1036, 2014. [2] Panida Seemawute and Smith Eiamsa-Ard, Visualization of flow and heat transfer in tube with twisted tape consisting of alternate axis, 4 th International Conference on Computer Modelling and Simulation (ICCMS 2012) IPCSIT, vol. 22, IACSIT Press, Singapore, 2012. [3] S. K. Saha, A. Dutta, and S. K. Dhal, Friction and heat transfer characteristics of laminar swirl flow through a circular tube fitted with regularly spaced twisted-tape elements, International Journal of Heat and Mass Transfer, vol. 44, pp. 4211-4223, 2001. [4] A. G. Patil, Laminar flow heat transfer and pressure drop characteristics of power-law fluids inside tubes with varying width twisted tape inserts, J. Heat Transfer, vol. 122, issue 1, pp. 143 149, 1999. [5] S. Eiamsa-ard, K. Wongcharee, and S. Sripattanapipat, 3-D Numerical simulation of swirling flow and convective heat transfer in a circular tube induced by means of loose-fit twisted tapes, Int. Common. Heat Mass Transfer, vol. 36, issue 9, pp. 947-9, 2009. [6] S. K. Saha, A. Dutta, and S. K. Dhal, Friction and heat transfer characteristics of laminar swirl flow through a circular tube fitted with regularly spaced twisted-tape elements, Int. J. Heat Mass Transfer, vol. 44, issue 22, pp. 4211-4223, 2001. [7] S. Eiamsa-ard, C. Thianpong, P. Eiamsa-ard, and P. Promvonge, Thermal characteristics in a heat exchanger tube fitted with dual twisted tape elements in tandem, Int. Common. Heat Mass Transfer, vol. 37, issue 1, pp. 39-46, 2010. [8] S. Eiamsa-ard, C. Thianpong, P. Eiamsa-ard, and P. Promvonge, Convective heat transfer in a circular tube with short-length twisted tape insert, Int. Common. Heat Mass Transfer, vol. 36, issue 4, pp. 3 371, 2009. [9] P. Ferroni, R. E. Block, N. E. Todreas, and A. E. Bergles, Experimental evaluation of pressure drop in round tubes provided with physically separated, multiple, short-length twisted tapes, Experimental Thermal and Fluid Science, vol., issue 7, pp. 17 1369, 2011. [10] Smith Eiamsa-ard, Pongjet Promvonge, Heat transfer characteristics in a tube fitted with helical scre tape with/without core-rod inserts, International Journal of Heat and Mass Transfer, vol. 34, pp. 176-185, 2007. [11] Smith Eiamsa-ard and Pongjet Promvonge, Performance assessment in a heat exchanger tube with alternate clockwise and counterclockwise twisted-tape inserts, International Journal of Heat and Mass Transfer, vol. 53, issue 7-8, pp. 1364 1372, 2010. [12] K. Maruta Micro and mesoscale combustion, Proc. Combust. Inst., vol. 33, issue 1, pp. 125-1, 2011. [13] Z. Turkeli-Ramadan, R. Sharma, and R. Raine, Clean flat flame combustor for ultra-micro gas turbine, in Proc. of 19 th Australasian Fluid Mechanics Conference, 2014. [14] Z. Turkeli-Ramadan, R. Sharma, and K. Yamaguchi, Combustion characteristics of HEX-combustor for ultra-micro gas turbine, in Proc. of the European Combustion Meeting, 2011. 27 tube heat exchanger with different twist ratio of perforated twisted tape inserts, International search Journal of Advanced Engineering