IOM IR-910M0-X. Hydrometer Magnetic Drive with solenoid control

Similar documents
IOM IR-110-X. Solenoid Control Valve

Flow Control & Pressure Reducing Valve with Hydraulic Control (Sizes 3''- 12"; DN80-DN300)

Flow Control Valve IOM 770-U

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

ZTM AND ZTMB ZENNER TURBINE METERS INSTALLATION, MAINTENANCE AND SERVICING

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

WW - Spare Parts - Ordering Guide

PRESSURE RELIEF VALVE

Pressure Reducing Valve Type 2114/2415

SINGLE ACTING ALTITUDE VALVE

ROOTS Meters Series B3 Meter Models 8C175-56M175

INSTRUCTION MANUAL INSTALLATION OPERATION TROUBLESHOOTING MAINTENANCE PRESSURE RELIEF VALVE WITH SURGE ANTICIPATION (HYDRAULIC) FEATURE MODEL 50RWR-A

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

Ordering Guide. Ordering Guide. May Water Control Solutions

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

Butterfly valves Figure 56 Installation & Maintenance Instructions

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

4 - Way Control 4 - Way Control 4 - Way Control with lock

V-SEGMENT SERIES V-Port Segment Control Valves (VS/VV/VM) Installation & Maintenance Manual

INSTALLATION & MAINTENANCE MODEL mm

KIT CONTENTS

Operation and Maintenance Manual

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

Industrial Turbo Meters, Sizes 2" through 6"

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

BERMAD Irrigation. Hydraulic Control Valves 900 series - Hydrometers. Water Control Solutions

Model DFR 070/156/220 Rotary Actuator

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

Operating Manual. Hydra S (W)VAC

MODEL 1100 TURBINE FLOW METER

AUTOMATIC FLOW CONTROL VALVE. INSTRUCTIONS Installation - Operation - Inspection - Maintenance

200 Series - Plastic Hydraulic/Electric Control Valves. Water Control Solutions

ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

KEYSTONE. Butterfly valves Figure 9 Installation & Maintenance Instructions. Please read these instructions carefully

CIRCLE SEAL CONTROLS

I & M MK96 & MK96C. Ideal Installation. Start-Up. Maintenance PROTECT VALVES WITH LINE STRAINERS

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

METERING VALVE 2" STEM GUIDED

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions

DC-501 Double Check Backflow Preventer OPERATIONS, MAINTENANCE AND TROUBLESHOOTING GUIDE

I & M Mark 708. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & 14M Actuator and Motor Valve

APT10-2 Automatic Pump Trap

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

CIRCLE SEAL CONTROLS

1451 Control Valve. General Instructions. Table of Contents

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

Figure DC03. Double check valves for medium hazard rated applications BSP screwed connections. Features

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

Instructions for Installing and Operating Clark Reliance EA100 Series Levalarm

CHEM-TEX POWER MAX 25 GOLD EDITION TRUCK MOUNT MANUAL

KEYSTONE OPTISEAL F14/16-15/17 AND BREWSEAL BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

CV Control Valves Installation and Operation Manual

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

Section 7.1. Wheel Drive Circuit - General System

CAUTION: The possible problems and causes are listed in order of likelihood and ease of checking.

2001 SERIES CRYOGENIC BAR STOCK BODY VALVES

CAUTION: The possible problems and causes are listed in order of likelihood and ease of checking.

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

Type EZR Relief Valve or Backpressure Regulator

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

Three Way Pilot Control

EZH and EZHSO Series. Pressure Reducing Regulators. EZH and EZHSO Series. Introduction. Scope of the Manual. Product Description !

Fisher 2052 Diaphragm Rotary Actuator

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

Track Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel

Installation Instructions

Warning and Safety Precautions

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

Operating Procedures for 4 to 24 Double Block and Bleed Test and Isolation Plugs

APT14 Automatic Pump Trap Installation and Maintenance Instructions

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

GP-2000 : Trouble Shooting. Cause of problems

HYDROMETERS OPERATION, INSTALLATION & MAINTENANCE GUIDE

IOM WW Electronic-Control Valve

J Flow Controls Model Numbering

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

TECHNICAL DATA 1-1/2 (dn40)

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

CUSTOM COMBINATION AIR VALVE

Pilot-Operated Regulators

SEASONAL MAINTENANCE CHECKLISTS Johnson Controls

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03

INSTRUCTIONS Installation - Operation - Inspection - Maintenance 4" - 16" ROSS MODEL - 30AWR FIGURE 29 SINGLE ACTING ALTITUDE VALVE

INSTRUCTIONS FOR INSTALLATION, START-UP, AND OPERATION

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

HYDRAULIC PUMP. INSTALLATION, OPERATION, & MAINTENANCE MANUAL MAINTENANCE MANUAL #: MM-HP Rev. A Page 1 of 12

Transcription:

IOM IR-910M0-X Hydrometer Magnetic Drive with solenoid control (Sizes 1.5''- 4"; DN40-100) Description: The BERMAD Hydrometer with Solenoid Control integrates a Vertical turbine Woltman-type water meter with a diaphragm actuated hydraulic control valve. The impeller drive is magnetically coupled to a vacuum-sealed meter register in the control head. As the system's Flow Meter and Main Valve, it controls system irrigation together with the iriigation controller. The BERMAD Model IR-910-M0-X opens and Shuts in response to an electric signal. Installation: 1. Ensure enough space around the valve assembly for future maintenance and adjustments. 2. Prior to valve installation, flush the pipeline to insure flow of clean fluid through the valve. 3. For future maintenance, install Isolation gate valves upstream and downstream from Bermad control valve. 4. Install the valve in the pipeline with the valve flow direction arrow in the actual flow direction. 5. For best performance, it is recommended to install the valve horizontally and upright. 6. After installation carefully inspect/correct any damaged accessories, piping, tubing, or fittings. 7. Cross-Check solenoid specifications with design requirements and solenoid/coil label. 8. Ensure approved cable protection. Confirm that the wires data meet solenoid specifications. Note: Energizing the solenoid coil when it is not fixed in its place, is dangerous and might burn the coil. 9. It is highly recommended to install a strainer Bermad model 70F upstream from the pressure reducing hydrometer, to prevent debris from damaging valve operation. Commissioning & Calibration: 1. Confirm that the In-line filter arrow [4A] direction is in the valve flow direction. 2. Allow the valve to open by using the solenoid manual override or by: Operating the solenoid. 3. Open fully the upstream isolating valve and slowly open the downstream isolating valve, to fill-up, carefully, the consumers' line downstream from the Valve. 4. Vent air from the valve's control loop by loosening cover tube fitting at the highest point, allowing all air to bleed. Then Retighten the tube fitting. 5. Check valve solenoid control feature by De-Energizing & Energizing the solenoid to close & open the valve.

IOM IR-910-M0-X Trouble-Shooting: Symptoms Cause Remedy Valve fails to open Valve fails to close 1. Not sufficient inlet pressure. 2. Not sufficient flow. 3. Solenoid functioning 1. Control circuit is clogged. 2. Debris. 3. Diaphragm. 4. Solenoid functioning 1. Check for sufficient inlet pressure. 2. Create demand/flow. 3. Check solenoid power supply, coil & Manual Override Handle position 1. Check for any debris trapped in the valve control circuit. 2. Check for any debris trapped in the valve body. 3. Check diaphragm is not leaking. 4. Check solenoid power supply, coil & Manual Override Handle position Preventive Maintenance: 1. System operating conditions that effect on the valve should be checked periodically to determent the required preventative maintenance schedule. 2. Maintenance instructions: 2.1. Tools required: 2.1.1. Metric and imperial wrenches 2.1.2. Anti-seize grease 2.1.3. Visual inspection to locate leaks and external damages 2.2. Functional inspection including: closing, opening and regulation. 2.3. Close upstream and downstream isolating valves (and external operating pressure when used) 2.4. Once the valve is fully isolated vent pressure by loosening a plug or a fitting. 2.5. Open the screw nuts and remove the cover unit from the valve body. Disassemble necessary control tubs. 2.6. It is highly recommended to stock a reserve parts assembly for each size. This allows minimum system field work. And system down time. 2.7. Disassemble the cover and examine the inside parts carefully for signs of wear, corrosion, or any other abnormal conditions. 2.8. Replace worn parts and all the Elastomers. Lubricate the bolts and screws threads with Anti seize grease. 2.9. Winterizing /freezing prevention: drain the valve & the valve accessories (pilot, solenoid) on time. Spare Parts Bermad has a convenient and easy to use ordering guide for valve spare-parts and control system components. For solenoid valves refer to model and S/N on solenoid tags. Pub # : IOMIR-910-M0-X-1.5'' 4'' By : YG 7/12 Rev: YG 7/12 File name : IOMIR-910-M0-X-1.5"-4''- 7/12 PT1AE08-01

CBM - Magnetic Drive Hydrometers Sizes: ; R 1½-3 DN40-80R 15a

CBM - Upgrading-Kit For Magnetic Drive Hydrometer Sizes: ; R 1½-3 DN40-80R 15f

CBM - Magnetic Drive Hydrometer Sizes: ; 3-4 DN80-100 * 15f *

CBM - Upgrading Kit Magnetic Drive Hydrometer Sizes: ; 3-4 DN80-100 16f

CBM - Magnetic Drive Hydrometer Sizes: ; 6-10 DN150-250 17a

CBM - Upgrading Magnetic Drive Hydrometer Sizes: ; 6-10 DN150-250 17f

G, A & H Bodies Patterns Options Sizes: ; 1½-10 DN40-250 17g

WPH Series Woltman Turbo-Bar Water-Meters Sizes: ; 1½-5 DN40-125 19