ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

Similar documents
ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZS10-PE Screw Clamp Terminal Blocks Ground

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

ZS4-PE Screw Clamp Terminal Blocks Ground

ZS35 Screw Clamp Terminal Blocks Feed-through

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

ZS6 Screw Clamp Terminal Blocks Feed-through

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZS50-PE Screw Clamp Terminal Blocks Ground

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZK4-PE PI-Spring Terminal Blocks Ground

ZS4-PE Screw Clamp Terminal Blocks Ground

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK6 PI-Spring Terminal Blocks Feed-through

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits

ZS4 Screw Clamp Terminal Blocks Feed-through

ZS10 Screw Clamp Terminal Blocks Feed-through

ZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

ZK4-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK2.5-PE-4P PI-Spring Terminal Blocks Ground with 4 connections

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

ZS6 Screw Clamp Terminal Blocks Feed-through

ZDP Pluggable Terminal Blocks Feed-through

ZP2.5-PE Spring Terminal Block Ground

DBL distribution blocks 3x1 pole

ZP2.5-4P Spring Terminal Block Feed-through

ZS4-SF1 Screw Clamp Terminal Block

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

Main catalog. SNK series Terminal blocks. Phone: Fax: Web: -

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Electronic overload relay EF65, EF96 and EF146

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Electronic overload relays EF205 and EF370

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Thermal overload relay TF140DU and TF140DU-V1000

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Thermal overload relay TF65 and TF96

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Mini contactors B6, BC6 with 3 pole

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

MS General Information Extended Product Type: MS

Thermal Overload Relays

Manual motor starter MS116

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Manual motor starter MS132

Manual motor starter magnetic only MO325

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Manual motor starter MS116

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

AF40... AF96 3-pole contactors Technical data

DX³ RCCBs - ID 4P up to 100 A

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Manual motor starter MS132

Manual motor starter MS132

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

RX 3 M.C.B A up to 63 A

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

RX 3 M.C.B A up to 63 A

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

ABB i-bus KNX DG/S x DALI-Gateway Basic

Voltage limiting device HVL

Phase + Neutral, neutral on left side

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Data sheet. W-Series WDU 4 SL/EN

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

Surge arrester POLIM-H..SD

Voltage limiting device HVL

up to 63 A (1 module per pole)

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

B Mini Contactor V Hz

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

TX³ RCCBs 2P up to 100 A

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Transcription:

Technical Datasheet SNK6D00 Catalogue Page ZS-SF Screw Clamp Terminal Blocks For 5 x 0 and 5 x 5 fuses Protect your circuit with 5x5 and 5x0 fuse terminal blocks, compliant with IEC 607-7-3 standard (fuse not supplied with the terminal blocks). SNK607F00 SNK50005F0000 3D CAD outline drawings available on "Control Product 3D" portal SNC5005 F0000 Screw Clamp Terminal Blocks mm² AWG Ordering Details Color Grey, Dark Grey ey, Dark Grey 8 mm 0.35 in Spacing Type Order Code EAN Code Pack (ing) Weight ( pce) g ZS-SF SNK508R0000 375508 50 3.30 Declarations and Certificates CE CB RoHS USR CNR CSA EAC BV RINA DNV

Declarations and Certificates CE CE CB CB RoHS RoHS USR CNR USR CNR SND53U* SND630A0* SND30F0* SND60A0* CSA CSA SND670A0* EAC EAC SND60A* BV BV SND673A0* RINA RINA SND688A0* DNV DNV SND687A0* Explosive Atmosphere: ATEX Classification Group Category Protection Method In the presence of explosive dust atmosphere, terminal blocks are to be installed in certified enclosure II D General Information Wire stripping length TH 35-7.5, TH 35-5 Denudage IP0 TH 35-7.5, TH 35-5 NEMA Ex e: increased security The following information must be strictly adhered to in order to guarantee the terminal block electrical, mechanical and environmental performance. Protection Rail IEC 607- mm 0.3 in Operating tool Torque Flat screwdriver Tete de viscouple Screw clamp Flat screwdriver 3.5 mm 0.38 in 0.6 N.m 5.3 N.m ± 0. N.m ± 0.885 N.m Screw rail contact (Maximum value) Disconnect device Material Specifications Insulating material CTI Flammability Polyamide 600 V UL V0 NF F 6 IF Connecting capacity per clamp Rigid - Solid / Stranded conductor Flexible conductor Flexible conductor with non insulated ferrule Flexible conductor with insulated ferrule Gauge Ferrule maximum outer diameter or conductor insulation maximum outer diameter 0.... mm² 0.... mm² 0.... mm² 0.... mm² A3-B3 IEC 607- Needle flame testec 6065--5 Compliant Screw clamp... AWG... AWG... AWG 3 mm 0.8 in Ferrule 5.5 mm 0.6 in The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to mm²). Technical Datasheet SNK6D00 ABB

Multi Connecting capacity per clamp Rigid - Solid / Stranded conductors 0.....5 mm²... AWG Flexible conductors 0.....5 mm² Flexible conductors with twin ferrule 0.....5 mm²... AWG Don't mix solid and flexible conductors in the same clamp Don't mix solid or flexible conductors of different sizes in the same clamp The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to mm²) Cross section Rated cross section mm² AWG Maximum Cross section mm² AWG Electrical characteristics Current Rated current 6.3 A Field and factory wiring Cat. UL 5 A Factory wiring Cat. UL 5 A CSA-C-. n 58 6.3 A Maximum Exe current IEC/EN 6007-7 Rated short-time withstand current s (Icw) Short-time withstand current 0.5 s 5 s s 30 s min Rated short-circuit withstand current UL 5 Max. current (5 temperature increase) / Max. cross section (mm²) 6.3 A Maximum short circuit current (s) mm² Short Circuit Current Rating (SCCR) SA UL 5 supplement SCCR UL 5 With the following configurations: Suitable conductor wire range Maximum voltage Fuse class / Max. amp. Rating J T RK RK5 G CC Voltage Rated voltage IEC 607-630 V Rated voltage UL 5 300 V Use Group UL 5 B, C, D Rated voltage CSA-C-. n 58 300 V Rated voltage Ex e IEC/ EN 6007-7 Rated impulse withstand voltage IEC 607-8000 V Dielectric test voltage IEC 607-00 V Pollution degree IEC 607-3 Overvoltage category IEC 607- III ABB Technical Datasheet SNK6D00 3

Temperature range Ambient temperature min/max Storage -55... + C Installing -5... +0 C Service -55... + C -67... +30 F +3... + F -67... +30 F Current Derating curve for continuous service temperature SNK5000F0000 Dissipated power Maximum dissipated power at rated current IEC 607- Maximum dissipated power at maximum Exe current IEC 6007-7 Rated power dissipation at an ambient temperature of 3 C - IEC 607-7-3 Separate arrangement / Overload and short-circuit protection.5 Separate arrangement / Exclusive short-circuit protection fuse and feed-through blocks Compound arrangement / Overload and short-circuit protection.6 Compound arrangement / Exclusive short-circuit protection 5 fuse blocks Environmental Characteristics Additional climatic tests Dry heat Cyclic damp heat Cold Damp heat steady state IEC 60068- Compliant Temperature +0 C 6 h IEC 60068-30 Compliant Temperature +55 C Relative humidity Number of cycles ( cycle = h) IEC 60068- Compliant Temperature -0 C 6 h IEC 60068--78 Temperature Relative humidity Corrosion Salt mist IEC 60068- Compliant 6 h Concentration 5 % SO ISO 688 Compliant 8 h Concentration 0. dm³ Flowing mixed gas corrosion test IEC 60068-60 Number of the test method Technical Datasheet SNK6D00 ABB

Vibrations and shocks Sinusoidal vibrations IEC 60068--6 Compliant Frequency range... 55 Hz Number of cycles Acceleration m/s² Functional random vibrations IEC 6373 Category Class B 3 axes Frequency range Acceleration Long life testing at increased random vibrations Category Class B 3 axes Shock Category Class B 3 axes ZS-SF Terminal Block Accessories Compatibility Some accessories may modify the terminal block's rating. See complete information in the accessories catalog page. IEC 6373 Frequency range Acceleration IEC 6373 Acceleration Description Type Order Code Pack (ing) Weight pieces g ( pce) MG-CPM 3 SNB07R06 680 0.73 3 5 6 7 8 End Sections End Stops End Stops Protecting Covers Protecting Cover Kits Tools Lateral Jumper Bars Assembly Rods Assembly Rods Assembly Rods Spring Retaining Rings MC8 MC8-YL MC8PA UMH PROCAP8 SAT8 PR3.G PR PR5 PR30 PR3.Z ES-SF BAM BAZ CO KCO PS-3 PC8- FU50 FU50 FU50 FU50 FU50 FU55 FU55 FU55 FU55 FU55 TGA8 TGA8 TGA8 ANT SNK60000R0000 SNK6000R0000 SNK6R0000 SNK006R0000 SNK0063R0000 SNK0066R0000 SNA6800R0300 SNA68500R00 SNA68700R00 SNA730R0500 SNA7300R700 SNK50860R0000 SNK0000R0000 SNK0000R0000 SNK0060R0000 SNK006R0000 SNK00650R0000 SNA7353R0 SNA00888R500 SNA0088R600 SNA0080R300 SNA008R0000 SNA008R00 SNA6756R00 SNA6757R300 SNA6758R000 SNA675R0500 SNA67550R000 SNA6867R0 SNA68673R00 SNA6867R300 SNA68675R00 0 0 5 0 50 50.00.00.00 0.0.00 6.00 78.00 5.00 700 38.00 78.00.80.00 5.30 300.00 7.80 380.00 5.00.00.00.50.00 ABB Technical Datasheet SNK6D00 5

Contact us ABB France Electrification Products Division PG Connection 3, rue Jean Perrin F-6687 Chassieu cedex / France Tel. +33 (0) 7 7 Fax +33 (0) 7 35 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 0 ABB All rights reserved SNK6D00 - PDF