Table of Contents. Classifications.. 5. Installation.,12. Focusing..14. Operating Instructions..15. Charts Description Maintenance...

Similar documents
AMCON AUTOMATIC CHART PROJECTOR USER S MANUAL EQ-6002

AP250 Automated Projector

OPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH

LED HANDHELD SLIT LAMP

Preface. Scope of Application. General Requirements for Safety THE SAFETY MARKS USED IN THIS INSTRUMENT

USER MANUAL. SLIT LAMP MICROSCOPE Model: GR-7. Version: 1.0. Gilras LLC

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY

Xenon Fiberoptic Lightsource

USER MANUAL LUX-LD30W LED MOVING HEAD

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

USER MANUAL SLIT LAMP MICROSCOPE

LED Twister II. User manual UK Version 1.0

XPERT SL 45 Slit Lamp. Instruction Manual

28W WORK LAMP Model: CTL28 Part No:

Stereo Microscopes Instruction Manual

PRECISION MICROSCOPES

CENTERING DEVICE. Model CE-1 OPERATOR S MANUAL

SZ2-ILA INSTRUCTIONS TRANSMITTED ILLUMINATION ATTACHMENT SZ-ADD SZ-POL-2 SZH-CLJ. Optional Modules

BEL-50N DENTAL CHAIR OPERATING INSTRUCTIONS IMPORTANT

Alternating Current Revolution per minute Protective Earth Ground. Protected from dripping water Fuse Attention, Consult Accompanying Document

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

LONGLIFE Project-O-Chart

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Corded and Cordless LED Worklight

MEDICAL IRRIGATION K PUMP OPERATING MANUAL: Manufactured for: K.M.I 3185 Palisades Dr Corona CA USA Model No.

The POWER In PRESENTATION PRODUCTS

FL Halogen light generator for use with fibre optic lighting. Mounting and installation instruction. Item no.: FL 20-2 Ø9 230V

1200W INVERTER GENERATOR

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-17B & AEU-17BV2 Implant / Surgery Systems

NearBright Illuminated Near Vision Kit. User s Guide

Isolation Transformer for Medical Applications

Dedicated PIR Light Controller c/w RF remote control for LEDPRO Floodlights

PLATE LOUPE PL-2 INSTRUCTION MANUAL. NEITZ INSTRUMENTS CO., LTD. International Division

Cordless Screwdriver

OPERATING INSTRUCTION

ORIGINAL INSTRUCTIONS

CURING LIGHT LED.B USER S MANUAL

1200W CaR PoliSheR en RS4900

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

AM-3000 Surgical Microscope User s Manual

Instructions For Use VATEA. Endodontic Irrigation Device

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

Triple Output Power Supply

USER MANUAL PAR56 LED PAR CANS

DC POWER SUPPLY ALIMENTATION C.C.

Instruction Manual LAMI CORPORATION INC.

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

SCAN OPTICS SO-161-R MICROSCOPE USER MANUAL

INTRODUCTION. Thank you for purchasing the Omni PINNACLE.

User Manual SONESTA S2 & S3

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

IsoLED FLEX I CUSTOMER MANUAL

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

ACROBAT SWING STAND MODEL

The Powermatic User Guide Test Sieve Shaker

INTRODUCTION...5 PARTS LIST...6 PACKAGING...9

INSTRUCTION MANUAL WARNING

MOVING HEAD. User manual CAUTION!

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

INTRODUCTION...5 PARTS LIST...6 PACKAGING...9 ASSEMBLY INSTRUCTIONS... 10

30,000mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Mania EF1 user manual

Snapshot Ok on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Instructions manual / Position Controller 1. GY-G Series INSTRUCTIONS MANUAL

1.Safe testing IMPORTANT:

Cordless two speed drill/driver K 10613

User Guide for Logo Projector

A B 0 0 C D E 6 7 G F F H 8 9 K M O O L N I J 1

Cordless High Speed Drill

4V LITHIUM-ION SCREWDRIVER OWNER S OPERATING MANUAL

Ego 01 Ego 02 Ego 03 Logo Projector user manual

USER S MANUAL TUBE SEALER. Model SE250. No. CAT.SE25010Ce

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

INSTRUCTION MANUAL ANGLE GRINDER PT W

TWIN HALOGEN SHOP LIGHT

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

KAC-8104D INSTRUCTION MANUAL CLASS D MONO POWER AMPLIFIER B /00 (MV)

MODEL No s: PP3, PP3K

KAC-9104D INSTRUCTION MANUAL

Clinical Electric OPERATION MANUAL

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

BATTERY BOOSTER/CHARGER MODEL NO: DIGICAR 600

KAC-718 INSTRUCTION MANUAL MONO POWER AMPLIFIER B (EM)

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

Compact LED profile with zoom

1/2 HP SUMP PUMP OWNER'S MANUAL

Via Michelangelo Buonarroti, 52/B Cologno M.se (Mi) USER S MANUAL

Snapshot. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120 V/230 V Switchable Replaceable Fuse User-Serviceable.

INSTRUCTION MANUAL. Tel / Fax SOM-S056S-KE Rev.5

ECO Spot 2500 User Manual

Rechargeable Air Compressor

MANUAL EXC-120 MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

Register your product within 30 days of purchase to activate your one-year limited manufacturer s warranty at ovente.com/register

ECO Spot 2500 User Manual

Transcription:

-1-

Table of Contents Introduction 3 Package Contents 4 Classifications.. 5 Designated Symbols 6 Safety Instructions 7 Instrument Components 9 Installation.,12 Focusing..14 Operating Instructions..15 Charts Description...17 Maintenance...20 Basic Trouble Shooting. 24 Transportation.25 Technical Specifications..26-2-

Introduction Congratulations on your purchase of the ECP 5400 Auto Chart Projector. In the area of subjective refraction, the ECP 5400 is best used for measuring visual acuity. It is fully recommended that you carefully read, understand and follow the steps in this manual in order to ensure safe operation, optimum performance and a longer service life from your new instrument. Please retain this manual for future reference. -3-

Package Contents ECP 5400 and accessories were carefully checked and packed prior to the shipment. However, please check condition and contents upon delivery. In addition to ECP 5400, this shipment includes: 1 Metal Screen (400mm x 350mm) 1 Power Cord 1 Dust Cover 1 Remote Control 1 Pair polarized glasses 2 Spare fuses [1A, 250V] 2 AA-sized batteries -4-

Classifications [ Classification under the provision of 93/42/EEC(MDD)] ClassⅠ ECP 5400 is classified into ClassⅠ system. [Protection method against electric shock] ClassⅠ ECP 5400 is Classified into ClassⅠ instrument. ClassⅠ instrument in which protection against electric shock does not rely on basic insulation only, but which includes an additional safety precaution with the provision of the connection of the instrument to the protective earth conductor in fixed wiring of the installation in such a way that any accessible conductive parts cannot become live in the event of a failure of the basic insulation. [Degree of protection against ingress of liquids] IPX0 ECP 5400 is the ordinary instrument (enclosed instrument without protection against ingress of liquids). Be careful not to splash water on the instrument. [Degree of protection against flammability] ECP 5400 is classified as an equipment not suitable to be used in a Potentially flammable anesthetic mixture with air or with oxygen or nitrous oxide. Do not use near flammable materials. [Mode of operation] Continuous operation -5-

Designated Symbols Symbol Description This symbol indicates a protective earth This symbol indicates that important operating and maintenance Instructions are included in this User s Guide. This symbol on the main switch indicates that the power is OFF. This symbol on the main switch indicates that the power is ON. Manufacturer Date of Manufacturer Authorized Representative in the European community This symbol indicates a fuse. For EU Countries The following mark, the name & address of the EU Representative shows compliance of the instrument with Directive 93/42/EEC. -6-

Safety Instructions At Operation - Never disassemble or touch the inside of the instrument. This may result in an electric shock or instrument malfunction. -Never yank the power cord to disconnect from wall outlet but hold the plug while disconnecting. This can weaken the metal core of the cord and may result in a short circuit or an electric shock. At Storage - Do not store the instrument in a place where it may get wet or where poisonous gas or liquid is stored. - Avoid storing the instrument in an area with excessive heat, humidity, or dust. Recommended ranges: Temperature range within -10 to +70 Relative humidity range within 30% to 85% Atmospheric pressure range within 500 to 1060hPa At Installation - Do not install the instrument near water. If water gets into the internal structure, there is the possibility of electrical Shock or instrument malfunction. -7-

- Install the instrument in a stable and level place where vibration or shock does not occur. The instrument may not perform observation correctly or may malfunction. Also, if the instrument is tripped over because of any accidental shock, it may result in possible injury. After Use - If the instrument is not be used for a long time, disconnect the power cord from the wall outlet. Otherwise, it may cause a tire. - Remove batteries from the battery case of the remote controller when the remote controller will not be used for a long time. At Disposal - Follow local governing ordinances and recycling plans regarding disposal or recycling of device components. Check the specified disposing method for the specific waste in advance, especially when disposing the batteries used in the remote controller. - When disposing packing materials, sort them by the materials and follow local governing ordinances and recycling plans. -8-

Instrument Components 1. Upper Case 2. Projection Lens 3. Window for remote detection 4. Table stand -9-

5. Focusing Wheel 6. Pilot Lamp 7. Power Switch 5. 8. RS-232C Connector 9. Power Connector 10. Fuse Holders -10-

11 12 13 18 14 19 15 16 20 21 17 11. Inflated ray transmitter 17. Vertical, horizontal line, single 12. Letters chart Letter Masking 13. Number chart 18. Children chart 14. Snellen chart 19. Vectograph chart 15. Program 20. Red/Green Test 16. Lamp ON/OFF 21. Direction -11-

INSTALLATION The ECP 5400 should be installed according to the following procedures: 1. If using a wall mount, it is best to locate a wall stud to support the weight of instrument. 2. Determine the refracting distance (form the patient s eye to the screen) and install the projection screen. 3. Position the instrument at the same distance from the screen to the patient within the range between 2m and 7m. To obtain longer refracting distances in small rooms, a mirror or systems of mirrors can be used. In this case, a high quality front surface mirror is required. -12-

4. Check the three-dimensional alignment of the system. The instrument is optimized when the projection screen is angled to direct light to the patient s head. Place a mirror on the screen. The light should project where the patient s head would be. -13-

FOCUSING To obtain the correct focus: 1. Measure the distance from the patient to the screen (refracting distance). 2. Turn the Auto Chart Projector on, and using the remote control, project the 0.05 K onto the screen. 3. If using a wall mount, it is best to locate a wall stud to support the weight of instrument. 4. Adjust the position of the instrument forward or backward for sizing. 5. Adjust for sharpness and clarity by turning the focusing wheel left or right as needed. -14-

OPERATING INSTRUCTIONS 1. Turn on the power switch of the instrument. The projection lamp lights and the chart for 0.05 vision shall be viewed in 3 seconds. 2. Changing the chart Press the appropriate chart button on the remote controller. The charts have 31 selections. 3. Isolating the visual acuity chart To use Vertical line masking: Press To move the position right or left Press or To move the position up or down Press or To use Horizontal line masking: Press To move the position right or left Press or To move the position up or down Press or To use Single letter masking: Press To move the position right or left Press or To move the position up or down Press or To use Red/Green filter: Press To release masking and filter: Press any chart button -15-

4. Programmed operation To install Program A 1) Make sure press the button of LAMP to turn off the lamp. 2) Keep pressing the left button to be heard buzzer sound 4 times. Then, start the mode of program A. 3) Press one of the chart buttons to memorize. 4) And then, press the right button and heard buzzer sound 1 time to memorize the selected chart. 5) Repeat the process 3, 4to memorize the selection you want. 6) Press the left button and heard buzzer sound 3 times to complete the installation of Program A. To install Program B 1) Make sure press the button of LAMP to turn off the lamp. 2) Keep pressing the right button to be heard buzzer sound 4 times. Then, start the mode of program B. 3) Press one of the chart buttons to memorize. 4) And then, press the right button and heard buzzer sound 1 time to memorize the selected chart. 5) Repeat the process 3, 4to memorize the selection you want. 6) Press the left button and heard buzzer sound 3 times to complete the installation of Program B. Programmed Operation 1) Turn on ECP 5400, press the button of RESET to select the program A or B. 2) After operate the program, change the chart by the button of PROGRAM. (Left : move to previous chart / Right : move to next chart) -16-

CHARTS DESCRIPTION A-TYPE letters Duochrome Balance Cross Cylinder Dots Red / Green Astigmatism Clock Dial Snellen Worth For Dot Phoria Fixation Phoria with Fixation Schober Coincidence Number Cross Grid Minute Stereo Children Binocular Balance -17-

B-TYPE letters Snellen Children Binocular Balance Duochrome Balance Cross Cylinder Dots Red / Green Astigmatism Clock Dial Landolt Worth For Dot Phoria with Fixation Number Fixation Coincidence Schober Minute Stereo Cross Grid -18-

C-TYPE letters Horizontal Line Red / Green Cross Cylinder Dots Snellen Worth For Dot Astigmatism Clock Dial Fixation Phoria Schober Phoria with Fixation Number Cross Grid Coincidence Vertical Children Binocular Balance Minute Stereo Children Vertical Line -19-

MAINTENANCE Risk of electric shock. Always disconnect the power cord from the wall and the instrument prior to performing any of the following procedures. Maintenance There is no periodic or routine user maintenance required. Cleaning There are no cleaning requirements other than regular office housekeeping, such as dusting. Cleaning the main body < Projection Lens > 1) Blow dusts with a blower brush. 2) If it is not clean enough, wipe with lens cleaning paper. < Cover and Screen > 1) Wipe with a dry and soft cloth. 2) If for some reason the instrument becomes soiled, wipe it with the damp lint-free cloth and mild detergent. Then, wipe off with a dry cloth to finish. Disassembling the upper case 1) Turn off the power and pull out the power cord. 2) Unfasten the screw in counterclockwise at the back side of case 3) Disassemble the Upper Case by lifting it. 4) In case of reassembling, place the Upper case on the main body and adjust t he front position. Then, fasten the screw in clockwise. -20-

Replacement of lamp The lamp may be HOT! Do not touch the Lamp directly and allow the sufficient amount of time to cool down the heat. 1) Unfasten the screw at the Lamp Cover. 2) Disassemble the Lamp Cover by lifting it and pull out the Lamp. 3) Place the new Lamp at the hole of Lamp Holder. 4) Turn on the power switch. 5) Place the white paper in front of the projection lens in order to project the filament image of lamp. -21-

6) Adjust the filament image at the center of paper with the screw at the lamp plate. (Note : Do not look into the lamp directly) 7) Place the Lamp Cover and fasten the screw. 8) Turn off the power switch. Replacement of Fuses 1) Turn off the power switch and disconnect the power cord. -22-

2) Push and turn the fuse holder a quarter counterclockwise with your finger and remove it. 3) Pull out the fuse from the fuse holder and check the condition. 4) Replace the fuse with the provided spare or equivalent as specified below. VOLTAGE 100V ~ 240V FUSE 1A 250V ; T1AL 5) Simply return it with the fuse holder to the socket. Push and turn it a quarter clockwise to lock. -23-

Basic Trouble Shooting Note: Risk of electric shock. Always disconnect the power cord from the wall and the instrument prior to performing any of the following procedures. If the instrument does not function at all: 1) Check the facility power source. (Circuit Breakers) 2) Check the electrical connections. (Power Cord) 3) Check the main fuse located on the rear of the unit. If the projector lamp does not light: 1) Check the main On/Off Switch. 2) Replace the lamp with the spare lamp. The lamp may be HOT! Do not touch the Lamp directly and allow the sufficient amount of time to cool down the heat. If the projector turns on but does not function: 1) Check the batteries in the remote control. -24-

Transportation Make sure the instrument is disconnected from the power source. If the instrument was installed on a custom mount, please remove the unit from the mount. Pack the instrument in a sturdy carton with suitable packing materials. After packing, do not hurl and impact cause of breakable goods. - Do not use this machine near by other machines or electric bulb (ex. Halogen lamp), it will improperly operate on the effect of electronic waves. -25-

Technical Specifications Chart 31 Selections Chart selection speed Average 0.3 sec. 1 open Mask 3 horizontal lines 3 vertical lines 21 single letters Filter Red/Green Projection distance 2.0m~7.0m (3m is standard) Projection magnification 30 x (at 5m) Projection size φ252mm and 330mm(W) x 225mm(H) (at 5m) Tilt angle Ball joint (±10 degree) Lamp 6V 20W(Halogen) Power source AC 100~240V 50/60Hz Power consumption 80VA Auto-Off function 5~10minutes after Dimensions Main body : 265(H) x 230(W) x 360(D)mm Remote controller : 20(H) x 64(W) x 195(D)mm Net weight Main body : 6.0Kg Remote controller : 180g Accessories Optional accessories 1 dust cover 1 metal screen (400mm x 350mm), 1 Pair of polarizing spectacles 2 spare fuses 2 batteries (AA-sized) wall bracket floor stand red/green glasses Interface 8-pin connector for simultaneous control of chart, mask and R/G filter by a motorized refractor's control unit. -26-

-27-