PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

Similar documents
PRIME 1360 ekw 1700 kva 50 Hz 1500 rpm 400 Volts

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1500 ekw 1875 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

STANDBY 250 ekw 313 kva 60 Hz 1800 rpm 208 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

STANDBY 1250 ekw 1562 kva 60 Hz 1800 rpm 480 Volts

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts

STANDBY 900 ekw 1125 kva 60 Hz 1800 rpm 480 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 484 ekw 605 kva 50 Hz 1500 rpm 400 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

DIESEL GENERATOR SET FEATURES

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 480 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

PRIME 1825 ekw 2281 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm 480 Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm Volts

STANDBY 1600 ekw 2000 kva 50 Hz 1500 rpm Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 480 Volts

STANDBY 400 ekw 500 kva

Voltage 220 to or 1800 RPM

Mission Critical Standby 1800 ekw 2250 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

3412C Generator Set Electric Power. Specifications. Benefits and Features

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 225 ekw 281 kva

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

Mission STANDBY Critical Standby 2000 ekw 2500 kva 60 Hz 1800 rpm 480 Volts

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

STANDBY 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

PRIME 292 ekw 365 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

Specifications. C13 Generator Set Electric Power

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

DIESEL FEATURES GENERATOR SET

Mission Critical Standby 1400 ekw 1750 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

Specifications. 3406C Generator Set Electric Power

STANDBY 520 ekw 650 kva 50 Hz 1500 rpm 400 Volts

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

PRIME 365 ekw 456 kva 60 Hz 1800 rpm 480 Volts

400 to 11,000 Volts. Standby, Prime, Continuous

Caterpillar 2500 kw 3516C

STANDBY 240 ekw 300 kva 50 Hz 1500 rpm 400 Volts

220 to volts. Electronic unit injection

PRIME 480 ekw 600 kva 50 Hz 1500 rpm 400 Volts

Transcription:

DIESEL GENERATOR SET PRIME 1200 ekw 1500 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Image shown may not reflect actual package. FEATURES FUEL/EMISSIONS STRATEGY Low fuel consumption DESIGN CRITERIA The generator set accepts 100% rated load in one step. FULL RANGE OF ATTACHMENTS Wide range of bolt-on system expansion attachments, factory designed and tested Flexible packaging options for easy and cost effective installation SINGLE-SOURCE SUPPLIER Fully prototype tested with certified torsional vibration analysis available WORLDWIDE PRODUCT SUPPORT Caterpillar dealers provide extensive post sale support including maintenance and repair agreements Caterpillar dealers have over 1,600 dealer branch stores operating in 200 countries The Cat S O S SM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products CAT 3512B TA DIESEL ENGINE Reliable, rugged, durable design Field-proven in thousands of applications worldwide Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight CAT SR5 GENERATOR Matched to the performance and output characteristics of Caterpillar engines Industry leading mechanical and electrical design Industry leading motor starting capabilities High Efficiency CAT CONTROL PANELS Simple user friendly interface and navigation Scalable system to meet a wide range of customer needs Integrated Control System and Communications Gateway

FACTORY INSTALLED STANDARD& OPTIONAL EQUIPMENT System Standard Optional Air Inlet Single element canister type air cleaner Dual element & heavy duty air cleaners (with pre-cleaners) Air inlet adapters & shutoff Cooling Radiator with guard (43ºC) Coolant drain line with valve Fan and belt guards Caterpillar Extended Life Coolant Low coolant level & high temperature alarm or shutdown Radiator with 50ºC ambient capability Radiator removal Heat exchanger and expansion tank Radiator duct flange Coolant level switch gauge Jacket water heater Exhaust Stainless steel exhaust flex and ANSI outlet flange Mufflers (10, 20 & 35 dba) Fuel Generator Power Termination Primary & secondary fuel filters Fuel priming pump Flexible fuel lines Class H insulation Class F temperature (105ºC prime/130ºc standby) Reactive droop CAT digital voltage regulator (CDVR) with KVAR/PF control, 3-phase sensing Bus bar connections Winding temperature detectors Anti-condensation space heaters Segregated low voltage (AC/DC) wiring panel Bus bar (NEMA and IEC mechanical lug holes)- right side standard Top and bottom cable entry Fuel cooler Primary fuel filter with fuel water separator Oversize & premium generators Circuit breakers, UL listed, 3 pole shunt trip,100% rated, choice of trip units, manual or electrically operated (low voltage only) Circuit breakers, IEC compliant, 3 or 4 pole with shunt trip (low voltage only), choice of trup inits, manual or electrically operated Shroud cover for bottom cable entry Power terminiations can be located on the left and/or rear as an option. Also, multiple circuit breakers can be ordered (up to 2) Governor ADEM II Low emissions conversion Load share governor Control Panels EMCP II+ EMCP II+ with Auto-Paralleling Switchgear conversion Customer Communication Module Local alarm & remote ammunciator modules Lube Lubricating oil and filter Oil drain line with valve; piped to edge of base frame Fumes disposal; piped to front of radiator Manual prelube with sump pump Electric & air prelube pumps Oil level regulator Mounting Mounting Starting/Charging Rails- engine/generator/radiator mounting Anti-vibration mounts (shipped loose) Rubber anti-vibration mounts (shipped loose) 330 mm (13 in) structural steel rails Spring-type, anti-vibration mounts (shipped loose) 45 amp charging alternator Energize to run (ETR) fuel shutoff solenoid 24 volt starting motor(s) Battery with rack, cables and disconnect switch Isolator removal Spring-type vibration isolator Battery chargers (5 or 10 Amp) Oversize batteries Ether starting aids Heavy duty starting motors Barring device (manual) 2 February 09 2009 03:23 AM

SPECIFICATIONS CAT GENERATOR Caterpillar Generator Frame size... 824 Excitation... Permanent Magnet Pitch... 0.6667 Number of poles...4 Number of bearings... Single Bearing Number of Leads... 6 Insulation... UL 1446 Recognized Class H with tropicalization and antiabrasion Alignment... Pilot Shaft Overspeed capability - % of rated... 180 Wave form...003.00 Paralleling kit/droop transformer... Standard Voltage regulator.3 Phase sensing with selectible volts/hz Voltage regulation...less than +/- 1/2% (steady state) Less than +/- 1% (no load to full load) Telephone Influence Factor... Less than 50 Harmonic distortion... Less than 5% CAT DIESEL ENGINE 3512B TA, 4-stroke-cycle watercooled diesel Bore - mm... 170.00 mm (6.69 in) Stroke - mm... 190.00 mm (7.48 in) Displacement - L... 51.80 L (3161.03 in 3 ) Compression ratio... 14.0:1 Aspiration... TA Fuel system... Electronic unit injection Governor type... Caterpillar ADEM control system CAT CONTROL PANELS EMCP II+ 24 Volt DC Control NEMA 1, IP22 enclosure Electronically dead front Lockable hinged door Generator instruments meet ANSI C-39-1 Single location customer connection point Panel illuminating lights Warning / Shutdowns with indicating lights for: - Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (over crank) - Low coolant level - Auto / start / stop control Voltage adjust potentiometer True RMS AC metering, 3-phase Digital indication for : - RPM - System DC Volts - Operating hours - Oil pressure (psi, kpa or bar) - Coolant temperature - L-L volts, L-N volts, Phase amps, Hz - ekw, kva, kvar, kwhr, %kw, PF(*) Programmable protective relaying functions - Under and over voltage - Under and over frequency - Reverse power - Overcurrent Consult your Caterpillar Dealer for Details 3 February 09 2009 03:24 AM

TECHNICAL DATA Open Generator Set - - 1500 rpm/50 Hz/400 Volts Low Fuel Consumption DM3062 Generator Set Package Performance Genset Power rating @ 0.8 pf Genset Power rating with fan 1500 kva 1200 ekw Coolant to aftercooler Coolant to aftercooler temp max 90 º C 194 º F Fuel Consumption 100% load with fan 75% load with fan 50% load with fan Cooling System 1 Air flow restriction (system) Engine coolant capacity 318.1 L/hr 84.0 Gal/hr 238.8 L/hr 63.1 Gal/hr 169.7 L/hr 44.8 Gal/hr 0.12 kpa 0.48 in. water 156.8 L 41.4 gal Inlet Air Combustion air inlet flow rate 95.6 m³/min 3376.1 cfm Exhaust System Exhaust stack gas temperature Exhaust gas flow rate Exhaust flange size (internal diameter) Exhaust system backpressure (maximum allowable) Heat Rejection Heat rejection to coolant (total) Heat rejection to exhaust (total) Heat rejection to aftercooler Heat rejection to atmosphere from engine Heat rejection to atmosphere from generator Alternator 2 Motor starting capability @ 30% voltage dip Frame Temperature Rise Emissions (Nominal) 3 NOx mg/nm3 CO mg/nm3 HC mg/nm3 PM mg/nm3 492.3 º C 918.1 º F 258.6 m³/min 9132.4 cfm 203.2 mm 8.0 in 6.7 kpa 26.9 in. water 539 kw 30653 Btu/min 1149 kw 65343 Btu/min 212 kw 12056 Btu/min 138 kw 7848 Btu/min 47.4 kw 2695.6 Btu/min 2626 skva 824 105 º C 189 º F 3556.4 mg/nm³ 594.4 mg/nm³ 70.8 mg/nm³ 25.3 mg/nm³ 1 For ambient and altitude capabilities consult your Caterpillar dealer. Air flow restriction (system) is added to existing restriction from factory. 2 Generator temperature rise is based on a 40º C (104º F) ambient per NEMA MG1-32. 3 Emissions data measurement procedures are consistent with those described in EPA CFR 40 Part 89, Subpart D & E and ISO8178-1 for measuring HC, CO, PM, NOx. Data shown is based on steady state operating conditions of 77ºF, 28.42 in HG and number 2 diesel fuel with 35º API and LHV of 18,390 btu/lb. The nominal emissions data shown is subject to instrumentation, measurement, facility and engine to engine variations. Emissions data is based on 100% load and thus cannot be used to compare to EPA regulations which use values based on a weighted cycle. 4 February 09 2009 03:24 AM

RATING DEFINITIONS AND CONDITIONS Meets or Exceeds International Specifications: AS1359, CSA, IEC60034-1, ISO3046, ISO8528, NEMA MG 1-22, NEMA MG 1-33, UL508A, 72/23/EEC, 98/37/EC, 2004/108/EC Prime - Output available with varying load for an unlimited time. Average power output is 70% of the prime power rating. Typical peak demand is 100% of prime rated ekw with 10% overload capability for emergency use for a maximum of 1 hour in 12. Overload operation cannot exceed 25 hours per year. Prime power in accordance with ISO3046. Prime ambients shown indicate ambient temperature at 100% load which results in a coolant top tank temperature just below the alarm temperature. Ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO3046 standard conditions. Fuel rates are based on fuel oil of 35º API [16º C (60º F)] gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29º C (85º F) and weighing 838.9 g/liter (7.001 lbs/u.s. gal.). Additional ratings may be available for specific customer requirements, contact your Caterpillar representative for details. For information regarding Low Sulfur fuel and Biodiesel capability, please consult your Caterpillar dealer. 5 February 09 2009 03:24 AM

DIMENSIONS Package Dimensions Length 5689.9 mm 224.01 in Width 2150.5 mm 84.67 in Height 2230.3 mm 87.81 in Weight 15 082 kg 33,250 lb NOTE: For reference only - do not use for installation design. Please contact your local dealer for exact weight and dimensions. (General Dimension Drawing #1558403). Performance No.: DM3062 Feature Code: 512DE07 Gen. Arr. Number: 1662704 Source: European Sourced February 09 2009 14161362 6 www.cat-electricpower.com 2009 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, SAFETY.CAT.COM their respective logos, "Caterpillar Yellow," and the POWER EDGE trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.