INSTRUCTION MANUAL. AMS 1500 One Piece. Negative Pressure Unit (AMS-1500 NPU 230V)

Similar documents
INSTRUCTION MANUAL. AMS 4000 One Piece. Negative Pressure Unit (AMS-4000 NPU 230V)

SPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL. Issue No: 1

FILTRATION FUME CABINET MODELS T800 T1800 OPERATING AND MAINTENANCE MANUAL

Cummins and Fleetguard are registered trademarks of Cummins, Inc. Mann+Hummel is a registered trademark of Mann+Hummel GMBH

Operating Instructions. International English. CCS Dust Extractor

P&G MANUFACTURING INC.

Warning. Document ref: A October 2015

TITAN, ATLAS & SIRIUS SMALL, PORTABLE. economical cabinets. with low energy consumption

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

PURE SINE WAVE DC TO AC POWER INVERTER

PRECISION UK Ltd DUPLEX AGSS PLANT

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

Installation and Operating Guidelines Battery Back-up Pump System

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

VT Oil-Free Range Operators Handbook

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

(UK) Date : January 2014

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Mobile recleanable HEPA filter units for a flow of m 3 / h

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

Operators Guide: RoboSign Stop/Go Traffic Control System

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

Duct filter units. Duct HEPA filter units AKF

Operators Guide: RoboSign Stop/Go Traffic Control System

A I R C O M P R E S S O R S R O L L A I R E

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour

OPERATING AND MAINTENANCE INSTRUCTIONS HYDRAULIC ELECTRICAL PUMPS HAM (Manual control) HAE (Electrical control)

Fume Hood Standard. The appropriate maintenance/engineering division on each campus or other business unit operating on UofT property shall:

PowerPleat Air Cleaners

V-9B Battery Tub Vacuum Operating Instructions

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

X-3400A, X-3500, X-3700 OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS

World Leaders in Diesel Fuel Injection Test Equipment. HM1000. Microdiesel Clean Cabinet. Installation and Operation Manual

Operating Instructions

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

MAINTENANCE AND TESTING OF PORTABLE ELECTRICAL EQUIPMENT, RCDS AND TOOLS CS-OHS-33

Call us now: (+44) Fuel Polishing And Filtration Equipment. Page 1

RECHARGEABLE PORTABLE EVAPORATIVE COOLER

About Dustcontrol Filter Units

The Powermatic User Guide Test Sieve Shaker

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

Affordable portable filtration unit

Operations and Service Manual. X30208 Load Bank

Class II biological safety cabinets

1200W INVERTER GENERATOR

IAQ-V mm Ø Carbon Filtered Supply Valve

ECONOMISER SERIES E2T USER MANUAL

OPERATION INSTRUCTIONS

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Design Standard - Fume Hoods & Fume Hood Exhausts

PCR 6. Operators Manual. Vertical Laminar Airflow Cabinet with U.V. Sterilisation. Issue 05 September 2013

MPS14 Rack Mount Power Supply

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

DEPAUL UNIVERSITY. Fume Hoods Manual. Environmental Health & Safety. April 2017

OPERATIONAL INSTRUCTIONS

Process Inline Filter Protective filter PLF2-9HF

Type NAK. Gas-tight shut-off damper with pneumatic actuator

OPERATING MANUAL C-1350 CABLE PUSHER. Copyright 2003 by CBS Products (KT), Ltd

HEPA AIR FILTRATION SYSTEM

XS400 Load Bank. Read all instructions before using the load bank. Contents

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Single Phase Floor Grinder

Breezair TBA 550 Installation Manual

MOBILE FILTRATION FUME CABINET

General safety and installation information.

Medium and high pressure pumps

SUBMERSIBLE WATER PUMP

THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

X100P Load Bank. Read all instructions before using the load bank. Contents

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

POTENTIAL HEALTH & SAFETY HAZARDS

Safety Sensor CSS 180 Product Information


MiniRoom. Isolation cubicles flexibility with containment. Horizontal laminar flow of air for greater protection - positive or negative

Wilo-Control SC-Fire Jockey

THERMOSTATIC CONCENTRIC DUAL CONTROL SHOWER VALVES Installation & aftercare instructions

Thermo Scientific 1300 Series A2. Class II, Type A2 Biological Safety Cabinets. Good for you good for the environment

Sieve Shaker 200mm/300mm - 8/12 inch SV003

Fixed Range Exhaust Flow Canopies for NU 540 (Series 1 ), NU 543 (Series 1 ) Class II, Type A2, Biological Safety Cabinets

KenkoAir_Purifier manual ENG-FR_FDA 10/12_Air Filter manual 8/15/13 10:44 AM Page 1 OPERATING MANUAL

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents

PowerPleat Air Cleaners

LNG Screw Down Non-Return Valve Installation, Operation and Maintenance Manual

The Stannah Stairiser SX User Manual

6L Oil-less Air Compressor 53103

6 Litre Oil-Less Air Compressor

Septic Tank. Installation Guidelines

Eazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

CIRCULAIRE FILTRATION FUME CUPBOARDS

is with a variety of standard dimensions. Also our units can be custom engineered to any size.

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

RESTWELL RISE & RECLINE ARMCHAIRS OWNER S HANDBOOK PARTS DESCRIPTION

Transcription:

INSTRUCTION MANUAL AMS 1500 One Piece Negative Pressure Unit (AMS-1500 NPU 230V) Page 1 of 19

WARNING Asbestos exposure can cause severe and fatal diseases. Approved Code of Practices should be applied at all times when using this equipment to ensure safe working conditions. Manufactured by: Air Management Systems Ltd Unit 1 9 Cannon Lane Tonbridge Kent TN9 1PP Tel: +44 (0) 1732 368359 Fax: +44 (0) 1732 368361 Web: www.ams-holdings.com About this Manual: The purpose of this manual is to enclose all relevant information and data to this particular product and related uses. This manual is to be utilised by the user of this product to ensure correct and safe methods are used during related operations. All Rights Reserved Contents of this manual are not be copied or distributed by anyone without permission of the manufacturing company of this product. Page 2 of 19

Table of Contents 1. Description and Data... 5 1.1 General Description... 5 1.2 Technical Data... 7 1.3 Airflow Performance... 8 2. Installation... 9 2.1 Power Requirements... 9 2.2 Positioning & Location of NPU... 9 2.3 Fixing & Installation of NPU... 9 3. Operation... 12 3.1 Preparatory... 12 3.2 Start up... 12 3.3 Normal Running Checks... 12 3.4 Shut Down... 12 4. Safety Procedures... 13 4.1 General... 13 4.2 Handling... 13 4.3 Transportation... 13 4.4 Storing... 13 5. Maintenance... 14 5.1 Periodical... 14 5.2 Preventative Maintenance... 14 5.3 Replacing Filters... 14 5.3.1 Pre-Filter Change Description... 14 5.3.2 Illustration of Pre-Filter Change... 15 5.3.3 HEPA Filter Change Description... 16 5.4 Fault Finding... 16 6. Equipment to be Serviced... 17 7. Accessories... 17 Page 3 of 19

7.1 Recommended Accessories... 17 7.2 Optional Extras... 17 8. Technical System Information... 18 8.1 Wiring Diagram... 18 9. Test Reports... 19 9.1 Airflow Tests... 19 Page 4 of 19

1. Description and Data 1.1 General Description AMS manufacture a range of Negative Pressure Units (NPU s) to provide a powerful filtered air extraction system. The NPU s are mobile, easy to handle, install and operate. All NPU s are manufactured from durable, robust, safe and easy to clean materials. AMS NPU s are mostly used in the Asbestos Removal Industries in Europe and other countries around the world that apply regulations to safely remove asbestos. The equipment is also used in other industries to control environments where air contamination is a problem, including the nuclear industry. NPU s are normally attached to a contained area (working enclosure) that is likely to become contaminated during the maintenance or removal work. Extraction of filtered air will provide Negative Pressure in the contained area preventing contamination to adjacent areas. In Europe and in other parts of the world it is a regulation to use this equipment during the removal of asbestos materials. AMS are specialist manufacturers of NPU s and other equipment used for the European asbestos removal industry. All equipment is manufactured to recognised European standards as well as adapted for the specific local requirements of a particular country. The AMS 1500 NPU provides a nominal airflow of 2400m 3 / hour (refer to test report section 9) with a filtration of 99.95% The NPU is compact and lightweight enough to be easily handled by one person and will pass through standard doorways. The standard NPU (AMS-1500) contains the following main components: - Main Case Enclosure - Electric Motor Fan - Pre-filter - HEPA Filter - Operation Control Instrumentation - Pressure Difference Indicator (manometer) For Optional Extras please refer to Section 7 of this manual The NPU case is constructed from welded polypropylene, reinforced with welded polypropylene internal ribs. Critical joints are triple-welded. Non-return flaps are fitted on the exhaust and the Basic Unit has an On/Off Switch, a Speed Controller and a Pressure Drop Indicator (manometer). Page 5 of 19

Product Details On/Off Switch Speed Controller Manometer (Indicates Pressure Difference) Figure 1.1 NPU Control & Monitor Components Exhaust Spigot (Ducting Connection Point) Handles for Transport Power Cord Figure 1.2 NPU View of Exhaust Spigot Page 6 of 19

Pre-Filter Castors Figure 1.3 NPU View of Pre-Filter Side 1.2 Technical Data AMS-1500 NPU Supply Voltage 230v @ 50Hz Current 7A Motor Output 1000w RPM 3000 Temperature Range -20 to +40 0 C Controls On/Off Switch and Speed Control Protection Inbuilt thermal cut-out with automatic reset Air Flow rate 2400m³ / hour Dimensions: Height Width Length Weight 561 mm 489 mm 850 mm 48kg Pre-filter Size Pre-filter Efficiency HEPA Filter Size 368 mm x 368 mm x 98 mm EU4 380 mm x 380 mm x 292 mm HEPA Filter Efficiency 99.995% Ducting Connection Size 305 mm diameter Page 7 of 19

1.3 Airflow Performance Airflow ratings for this particular NPU can be found in section 9 within the test report. When exhaust ducting is used the following considerations should be made: - If flexible ducting is used on the exhaust to a length of 5 metres in a straight line, airflow will not be impaired. - Any length of flexible ducting above this criterion will result in reduced flow performance and appropriate adjustments are recommended. - Typical airflow losses of 0.05-0.07 m³ per 6 metre length of ducting should be considered. - The exhaust of the NPU should be ducted outside of the building, where practicable. - It is recommended that the Pre-filter is changed at regular intervals to optimise the performance of the Negative Pressure Unit. Regular inspections of the filter must be carried out before, during and after use by competent, trained personnel. - When the reading on the manometer increases, this could indicate that the Pre-filter may require changing. If this reading remains relatively high with a clean Pre-filter, this could indicate that the HEPA Filter requires changing. We would recommend that the HEPA Filter is tested by an approved service centre at this stage. All type of filter changing is required to be done under controlled conditions. Page 8 of 19

2. Installation 2.1 Power Requirements The AMS-1500 NPU utilises an electric motor fan to generate the reduced enclosure pressure and the unit must be connected to a power supply capable of 13A continuous current. The 230V Negative Pressure Unit is supplied with a 5m fixed power cord. 2.2 Positioning & Location of NPU Considerations should be made to which location the unit will be installed. - The NPU should be located outside of the enclosure at all times - The NPU should be positioned on a sturdy base to avoid unwanted movement of unit, which could damage or break the seal between the NPU and enclosure. - Consider exhaust ducting path if needed before connecting the NPU to enclosure. - The unit shall be located in dry conditions, away from any water penetration or damp environments, to avoid the unit or any of its components becoming wet. - The power supply cables should be run in a manner that does not create a tripping hazard and avoid locations where excessive traffic is present, which could result in unit damage or injury. - The unit should not be located externally to any buildings ideally. If this cannot be avoided then the unit shall be located within a waterproof enclosure. 2.3 Fixing & Installation of NPU THE NEGATIVE PRESSURE UNIT SHOULD NOT BE INSTALLED INSIDE THE ENCLOSURE - FAILURE to comply will result in contamination of the NPU s clean side. Page 9 of 19

Example depicted in figure 2.1 2.3 applies to fixing and sealing a Negative Pressure Unit to a polythene enclosure. The Filter End of the NPU should be outside of the enclosure, with the inlet flange (Pre-filter inlet face) being taped to the polythene with cloth tape (refer to figures 2.2 & 2.3 to follow). - Position the Filter End of the NPU against the inside or outside of the enclosure. - Mark and cut a hole in the enclosure around the Pre-filter to accommodate the unit (figure2.2). - Install the NPU against the opening and seal with conventional materials such as Polythene and Tape. - Install the Pre-filter (pleats aligned vertically) and tape the edges to the enclosure to make a seal. The Pre-filter can then be changed without this seal between the enclosure and the NPU being disturbed. Enclosure Wall (Polythene) NPU Positioned Outside Enclosure INSIDE OUTSIDE Figure 2.1 NPU Positioned Outside Enclosure Page 10 of 19

Enclosure Wall (Polythene) Cut Polythene along all four edges to Fit Flange of NPU allowing Area for Tape Figure 2.2 Hole Cut to NPU Flange Size Enclosure Wall (Polythene) Edges to be taped from inside to form seal between NPU and Enclosure Figure2.3 All Four Edges to be Sealed via Tape Page 11 of 19

3. Operation 3.1 Preparatory The NPU should be operated under the supervision of competent and trained personnel. - Ensure that the unit is correctly installed according to Section 2. - Ensure that the enclosure is properly sealed to the Filter End of the NPU inlet face according to section 2.3. - Ensure that the installed Pre-filter is the recommended type and the pleats are aligned vertically (section 2.3). - Ensure that the NPU is switched off, prior to connecting to an appropriate power supply. 3.2 Start up - Once the enclosure is complete and the NPU has been prepared, as detailed under section 3.1, turn the Speed Controller to its minimum setting. - Switch on the first fan motor - Switch on the second fan motor. - Turn the Speed Controller clockwise until the required airflow is achieved. - Note the reading on the manometer and record this as the initial reference level 3.3 Normal Running Checks - Periodically check the pressure differential in the enclosure and adjust the Speed Controller accordingly. - If negative pressure reduces cannot be maintained, check the manometer on the NPU to determine the efficiency of the filters. Check this new reading against the initial reference level. If there is no significant increase in the pressure differential there could be a leak in the enclosure. If there is a significant increase in the pressure differential then the filter system could be blocked and would need to be inspected. 3.4 Shut Down - Switch both of the fan motors off via the switches on control panel Page 12 of 19

4. Safety Procedures 4.1 General - Power cables should be routed so that they do not create a tripping hazard. - Whilst not in use, the Transit Cover Plate should be fitted to the NPU s Filter End. - Whilst in use, the Pre-filter should be taped into place to prevent contamination ingress to the NPU. - Check that the NPU has not been damaged in any way to ensure the integrity of the casing and components. 4.2 Handling The NPU must not be moved whilst in operation. - The NPU must be moved with care and attention at all times to prevent damage. - The NPU should only be moved by competent personnel - You should consider the weight of the unit before deciding to move it and take all necessary precautions. 4.3 Transportation - Prior to transporting the NPU ensure that either the transit cover has been located over the Pre-filter or a suitable seal has been achieved with polythene and tape. - Whilst in transit, it is imperative that the NPU is secured, to minimise movement. This can be partially achieved by locking the braked castors, but further securing will be required. - Care is to be taken to ensure safe handling whilst inserting and removing the NPU from the vehicle. 4.4 Storing The NPU must be stored in a place that satisfies the following: - Dry and damp free - Internal temperatures between 0 o c and 40 o c - In A Safe manner so as to prevent hazards to personnel - Stacked on top of each other a maximum of one high - All castors should be locked on the NPU This list is not exhaustive and common sense must prevail. Page 13 of 19

5. Maintenance 5.1 Periodical - D.O.P testing and Inspection should be carried out every 6 months. - It is recommended to use authorised centres only. 5.2 Preventative Maintenance - Keep the NPU clean and dry. - Periodically check the condition of the power lead and keep in good condition. - Check the manometer reading against the initial reference level - Ensure that all personnel comply with your own filter change regime 5.3 Replacing Filters 5.3.1 Pre-Filter Change Description - Carefully remove tape from the dirty Pre-filter, remove the Pre-filter from the aperture and seal it in an approved asbestos waste bag. - All types of filter changing are required to be done under controlled conditions while using appropriate Personal Protective Equipment. - From NPU installation (section 2) the seal between the NPU and polythene sheet should still exist after Pre-filter has been removed. The new filter can now be inserted and must be sealed to the NPU via cloth tape. - Also refer to NPU installation to aid understanding of process. Replace the Pre-filter with an approved replacement, installing it with the pleats vertical & seal to NPU flange with tape Page 14 of 19

CORRECT ALLIGNMENT! PLEATS VERTICAL INCORRECT ALLIGNMENT! PLEATS HORISONTAL 5.3.2 Illustration of Pre-Filter Change Figure 5.1 Illustration of Pre-filter Pleat Alignment. (Example illustrates filter change of new and clean machine. PPE should always be used during filter changes) Insert Pre-Filter Figure 5.2 Installation of Pre-Filter Tape along Edges to Form Seal Figure 5.3 Taping of Pre-Filter to form Seal Page 15 of 19

Transit Cover Fixings Figure 5.4 Installation of Transit Cover 5.3.3 HEPA Filter Change Description - Under no circumstances can the HEPA filter be changed whilst operational and in situ. - All HEPA filter changes must be undertaken by qualified and competent service engineers under fully controlled conditions. 5.4 Fault Finding Problem Initial/Action Fault Further Action NPU not operational Cannot maintain Negative Pressure Check power supply is available and the unit is turned on Check Manometer against Initial Reference Level reading Faulty Fan or Electrical component Pre-filter may be blocked HEPA Filter may be blocked Call Service Engineer Replace Pre- Filter Call Service Engineer Enclosure has Leak Seal all leaks to Enclosure No reading on pressure indicator (Manometer) Speed Controller is not operational Check if Unit Operational Switch On/Off. Gauge Faulty Controller Faulty Call Service Engineer Call Service Engineer Page 16 of 19

6. Equipment to be Serviced - Before despatching for Service ensure that the NPU is suitable for movement, refer to Section 4 of this manual - All equipment to be despatched for Service must be clean and free from any contamination - Liaise with the Service Engineer for collection/delivery 7. Accessories 7.1 Recommended Accessories - Pre-filters to recommended standards. - Flexible Ducting, either aluminium foil or PVC. - Extension Pre-Filter box 7.2 Optional Extras In addition, the following optional extras can be supplied, these would have to be factory fitted at the NPU s next service or supplied when new. - Hour Counter o Allows the monitoring of a unit s processing time and could be used to determine when filter change is likely. - Residual Current Device o A safety device that cuts the power supply when an electrical short circuit occurs within the system. - Extension Pre-Filter Box o An additional pre-filter box connected to the NPU by means of flexible ductwork to allow the air intake of the unit to be located to suit site conditions. - Alarm Socket Page 17 of 19

o Alarm that sounds when power supply to NPU fails. Backup batteries allow alarm to function during power cut. - Remote alarm Device o An audible and visual alarm indicator to be connected to the Alarm socket - Remote Device Power Outlet o A power outlet to be used for other appliances or tools (to correct power rating). 8. Technical System Information 8.1 Wiring Diagram Figure 8.1 Wiring Diagram for AMS-1500 NPU Page 18 of 19

9. Test Reports 9.1 Airflow Tests NPU1 NPU2 NPU3 NPU4 NPU5 Serial No 12743 12744 12745 12746 12747 Manometer Reading 550 550 550 600 600 Skirt Area m 2 (A) 0.1383 0.1383 0.1383 0.1383 0.1383 Average Face Velocity 4.75 4.82 4.8 4.77 4.98 m/s (Y) Maximum Airflow Performance (m 3 /h) Calculation: + + + + + / 5 = A x 3600 x 2364.93 2398.12 2389.82 2373.22 2481.1 Y = 2401.44 Total: 12007.19 Model Tested: AMS-2500 NPU One Piece Anemometer Type: KIMO Tested By: Engineer: Air Management Systems Ltd Unit One, 9 Cannon Lane Tonbridge, Kent, TN9 1PP Test Date: Chris Barlow Engineer Signature: 14/12/10 Page 19 of 19