Designed for ease of integration with automation systems

Similar documents
Submittal Data Information

TDX - Taco Duplex Starter with

Submittal Data Information

INDUSTRIAL STARTERS ADVANCED SOLUTIONS FOR INDUSTRIAL APPLICATIONS

EPS-ECONOMY PUMP STARTER

EPS-ECONOMY PUMP STARTER

RVS-DN Digital Reduced Voltage Motor Starter

SECTION MOTOR CONTROL

Series Motor Protection

MAGNETIC MOTOR STARTERS

KD LV Motor Protection Relay

Flight Systems. Replacement for KASSEC DESCRIPTION

Softstarters. Softstarters Power electronic brakes Type PEB

RVS-DX Digital Reduced Voltage Motor Starter

Application Engineering

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

REVISED ATM72 Auto Transfer Module

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

Combined Ventilation Controller RVWS-T-224HA

Technical Specification. RCS Electric Actuators with a ProfiBus Field Control and Communication Module

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

Application Engineering

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

CTi Automation - Phone: Fax: Web:

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

DEEP SEA ELECTRONICS PLC

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

RVS-AX Instruction Manual

The JR Linear Drive System

Table of Contents. Chapter 1: Introduction 1.1 General Description 1. Chapter 2 - Installation 2.1 Receiving and Unpacking.. 5


Three-Phase Soft Starters

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

825-P Modular Protection System for motors Specification Guide

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters

Enclosed Full-Voltage Starters

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

BROCHURE. ABB drives for HVAC applications ACH550, 1 to 550 Hp

Application Description

Enclosed Full-Voltage Starters

Installation, Operation and Maintenance Manual

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Diesel generator set C17D5T series

Bulletin 825 SMM Smart Motor Manager

USERS MANUAL MCD REMOTE OPERATOR

Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

Table of Contents. 2 Installation and Start-up Instructions for AF-600 Bypass, NON Bypass & Disconnect Drive Panels - DEH40600

TRIPS AND FAULT FINDING

DSEULTRA DSE6000 Quick Start Guide Document Number

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

Installation, Operation and Maintenance Manual

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Installation, Operation and Maintenance Manual

Guardian Series. GUARDIAN SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Guardian Series INCLUDES:

Centurion Series. CENTURION SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Centurion Series INCLUDES:

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Heating Cable. Description

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Power electronic brakes

Fincor Series 2230 MKII/2240

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

RVS-DN Digital Soft Starter A, V Instruction Manual

Single & Three-Phase Soft Starters

Application Engineering Europe

GLM SERIES CONTROL Users Manual Rev:

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Large Drive. Variable Speed Control is Just the Beginning. Franklin FastApp Firmware. Variable Speed Control NEMA. Standard Features (Enclosed Drives)

Aldi V4 & V V1.1 5/23/2014

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

Product Description. Application Description

70 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES: Standby Power Rating Model QT070 (Bisque) - 70 kw 60Hz

LF Series Spring Return Direct Coupled Actuator

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

320 to 327 M Series Low and Medium Voltage Motor Protection Relays

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents

GENERAC GUARDIAN SERIES STANDBY GENERATORS

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Installation, Operation and Maintenance Manual

22 kva GENERAC STANDBY GENERATORS ISO. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES:

MAQ Series Electric Actuator

DEEP SEA ELECTRONICS PLC

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

IT. IEC Contactors, Starters, Overload Relays, and Accessories Product Focus

P-SERIES VFD WITH BYPASS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

Quietsource Series ISO. QUIETSOURCE SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Quietsource Series INCLUDES:

Transcription:

BAS, 200 ~ 600V, 1/2-30HP BUILDING AUTOMATION STARTER SMARTER AND MORE VERSATILE THAN EVER Smartstart Equipped with advanced I/O including Fireman s Override and damper control, the BAS was designed from the ground up for easy integration with automation systems. With a 200 to 600V input and 1-40A adjustable overload, the BAS is the right starter for almost any job. features Designed for ease of integration with automation systems Comprehensive inputs/outputs for building automation systems Reduces installation costs High reliability Smartstart patented superior motor protection Electronic overload protection including locked rotor, cycle fault and maximum time to start (due to mis-sized motor or overload) FLA out of calibration indication--ensures installer sets overload correctly based on calculated motor size Advanced control inputs eliminate interposing relays Three dry inputs for auto-run, permissive auto and shutdown Two voltage inputs (12-250VAC) for auto run and fireman s override Logging retains critical information Logging information is obtainable for starter failure (Factory retrievable only) Last 10 start conditions, including FLA setting, max inrush, run current, time to start, and safety start mode. Last 10 fault conditions, including FLA setting, fault type, fault current, and run time. Universal application Automatically detects voltage (200 to 600VAC) Converts to 24V for control power UL Type 1 and 3R enclosures Lockable enclosure 3R features lockable keypad cover Type 4 & 4X enclosure options available (consult factory) Hand/Off/Auto keypad with LED status indicators Intuitive operation and control with Hand (manual run), Off, and Auto run modes Combination versions include disconnect Motor circuit protection disconnect provides short circuit protection High interrupting ratings for maximum electrical system compatibility No fuses required Lockable handle for safety 2 www.franklin-controls.com 1.800.962.3787

BAS The BAS is automation ready. Building Management System (BMS) Signal in Signal out Signal in Signal out BAS Only BAS & SAS Motor Status Fault Alarm Fireman s Override Emergency Shut-down Auxiliary Input - Stop Command Damper Control Output Limit Switch Closed Signal Auxiliary Input - Run Command Motor Fan Damper Image provided by Greenheck Fan Corporation The Technology behind Smartstart Smart - Start safely even without calibration! Smartstart patented technology predicts a safe operating range for your motor based on the measured inrush current Intelligent - Smartstart detects if your starter needs to be calibrated, protecting you from operators trying to overcome motor jams or problems by oversetting the overload. With Smartstart enabled, if the starter isn t in range, it alarms and trips notifying you before damage occurs Motor Inrush 6-10x FLA Current (amps) Locked Rotor Trip Stall Trip (Disabled during startup) Max Time to Start Trip Active - Smartstart detects harmful extended starting conditions with maximum time to start. Monitors motor inrush current conditions and trips if the motor doesn t start within 10 seconds (class 10 overload) regardless of FLA setting. Ingenious - Active current monitoring provides superior protection against locked rotor and stall conditions, tripping faster than a standard inverse trip curve, regardless of the FLA setting! Thoughtful - Blackbox recording feature retains critical information on last ten faults and starts (factory retrievable only). FLA Standard Start Curve 1 2 3 4 5 6 7 8 9 10 Start Time (seconds) Locked Rotor Current Motor Never Reaches FLA Typical Motor Stall Current Standard Motor Starting Current 3

BAS Specification Starter Type BAS - Building Automation Starter 200-600VAC, 3-Phase, 50/60Hz input, Across the line, full-voltage non-reversing NEMA Type 1 or 3R Enclosed User Interface Hand/Off/Auto Keypad with LED mode indication Standard Control Operations Inputs Outputs Operational Voltage Auto-Run Dry Contact Auto-Run Fireman s Override Shutdown Permissive Auto Damper Limit Switch Status Relay Fault Relay Damper/Actuator Overload Type Fault Reset Power Fail Modes Accepts 12-250VAC/DC. Applying voltage will send a run command to the starter when in Auto mode. Open dry contact. When closed, the starter will be commanded to run when in Auto mode. Accepts 12-250VAC/DC. Applying voltage will cause the starter to run in all modes and all LEDs will flash. Closed dry contact. When closed, the starter will disengage the contactor and will not accept a run command (except Fireman s Override). Hand/Off/Auto LEDs will flash. Closed dry contact. When closed, the starter will not accept run commands in Auto mode (except Fireman s Override) Open dry contact. When used with the damper motor output, the contactor coil is in series with customer provided damper contacts which disable the motor starter until the damper is in position. Open relay contacts. Status Relay will close when the motor draws 60% of the FLA dial setting. Fault Relay will close in the event of a fault trip. Contact Ratings: 110VDC, 0.3A Resistive 125VDC, 0.5A GP 30VDC, 2.0A Resistive 120VAC 50/60Hz, 0.5A Resistive 125VAC 50/60Hz, 1.0A GP 240VAC 50/60Hz, 0.25A Resistive 24VDC, 1A max. Electronic I 2 t trip curve Manual (default) or Automatic Return to last mode the starter was placed in (Hand/Off/Auto) with no delay (default) Return to last mode the starter was placed in (Hand/Off/Auto) with a 10 second delay Return to Off mode (LED of last mode the starter was placed in will be flash) Environmental Ambient Operating Temp -5 to 140 F (-20 to 60 C) Ambient Storage Temp -5 to 185 F (-20 to 85 C) Relative Humidity 5% to 95% non-condensing Motor Protection Adjustment / Description Default Setting Overload Current Setting Range 1-40A Per FLA Overload Trip Class Adjustable: Class 10 or 20, Trip current = 115% of FLA setting Class 10 Cycle Fault Trip if cycle rate exceeds 20 starts/minute Always On Stall Trips within 0.5 seconds (disabled during startup) Always On Smartstart Protection Adjustment / Description Default Setting Current Phase Unbalance Trips within 3 sec @ 25% current unbalance. *Trip threshold changes to 80% unbalance when switched to Off Locked Rotor Trips within 0.5 seconds On/Off Trips after 10 seconds if the FLA dial setting is incorrect (set above calculated FLA Out of Calibration range), ie. Start current is outside of an acceptable range (fla setting * 5 < inrush < fla On setting * 14). Max Time to Start Regardless of FLA or I 2 t curve, always trip at start if starting current is outside of an acceptable range (inrush / 5) and still decreasing after 10 seconds. 4 www.franklin-controls.com 1.800.962.3787

BAS Ordering and Sizing Information (200~600 VAC) UL Type 1 Enclosed Combination UL Type 1 Enclosed - Combination Starter, Electronic Overload Includes MCP Disconnect Part Number 1Ø BAS1-9/P-G1.6-40 1/10 - - 3/4 3/4 100 65 25 BAS1-9/P-G2.5-40 1/6 1/2 1/2 1 1.5 100 65 25 BAS1-9/P-G4-40 1/3 3/4 3/4 2 3 100 65 25 BAS1-9/P-G6-40 1/2 1 1.5 3 3 100 65 25 BAS1-9/P-G8-40 1 2 2 5 5 100 65 25 BAS1-18/P-G10-40 1.5 2 3 5 7.5 100 65 25 BAS1-18/P-G13-40 2 3 3 7.5 10 100 65 25 BAS1-18/P-G17-40 3 3 5 10 15 100 30 10 BAS1-32/P-G22-40 3 5 7.5 15 20 100 30 10 BAS1-32/P-G26-40 3 7.5 7.5 15 20 100 30 10 BAS1-32/P-G32-40 5 7.5 10 20 25 100 30 10 BAS1-40/P-G40-40 7.5 10 10 30 30 100 30 10 1+ 00 0 1 Standard UL Type 1 Enclosed - Standard Starter, Electronic Overload Disconnect Not Included Part Number 1Ø BAS1-9/P-40 1 2 2 5 7.5 5 5 5 00 BAS1-18/P-40 3 5 5 10 15 5 5 5 0 BAS1-32/P-40 5 7.5 10 20 25 5 5 5 1 BAS1-40/P-40 7.5 10 10 30 30 5 5 5 2 5

Combination Ordering and Sizing Information (200~600 VAC) UL Type 3R Enclosed UL Type 3R Enclosed - Combination Starter, Electronic Overload Includes MCP Disconnect Part Number 1Ø BAS3R-9/P-G1.6-40 1/10 - - 3/4 3/4 100 65 25 BAS3R-9/P-G2.5-40 1/6 1/2 1/2 1 1.5 100 65 25 BAS3R-9/P-G4-40 1/3 3/4 3/4 2 3 100 65 25 00 BAS3R-9/P-G6-40 1/2 1 1.5 3 3 100 65 25 BAS3R-9/P-G8-40 1 2 2 5 5 100 65 25 BAS3R-18/P-G10-40 1.5 2 3 5 7.5 100 65 25 BAS3R-18/P-G13-40 2 3 3 7.5 10 100 65 25 0 BAS3R-18/P-G17-40 3 3 5 10 15 100 30 10 BAS3R-32/P-G22-40 3 5 7.5 15 20 100 30 10 BAS3R-32/P-G26-40 3 7.5 7.5 15 20 100 30 10 1 BAS3R-32/P-G32-40 5 7.5 10 20 25 100 30 10 BAS3R-40/P-G40-40 7.5 10 10 30 30 100 30 10 1+ Standard UL Type 3R Enclosed - Standard Starter, Electronic Overload Disconnect Not Included Part Number 1Ø BAS3R-9/P-40 1 2 2 5 7.5 5 5 5 00 BAS3R-18/P-40 3 5 5 10 15 5 5 5 0 BAS3R-32/P-40 5 7.5 10 20 25 5 5 5 1 BAS3R-40/P-40 7.5 10 10 30 30 5 5 5 2 The new BAS 3R enclosure is significantly smaller and lighter than its predecessor *NEMA 4X & 12 enclosures available upon request 6 www.franklin-controls.com 1.800.962.3787

BAS Wiring DIAGRAM BAS CONTROL WIRING PCB Power Coil BAS STARTER POWER WIRING A2 contactor coil BAS 10 15 20 5 25 1 30 Voltage Inputs Auto Run Fireman s Override 12-250VAC/DC Input 12-250VAC/DC Input 35 FLA (A) 40 Overload Setting Relay Outputs Status Common Fault OL Keypad PCB Power Dry Inputs Actuator Control Coil Shut Down Permissive Auto Run Motor Limit Switch A1 A2 Closed Input Open Input Open Input 24VDC, 1A Output Open Input M 24V Output to contactor coil MCP (Optional) 208-600 VAC Input L1 T1 T2 T3 L2 L3 M 43 31 T1 T3 T3 44 32 T1 T2 T3 AUX CONT MTR 3PH All dimensions are in inches BAS STARTER POWER WIRING ul type 1 dimensions OL 43 31 MCP (Optional) M T1 T3 T3 44 32 208-600 VAC Input T1 T2 T3 L1 L2 L3 T1 T2 T3 AUX CONT MTR All dimensions are in inches 3PH ul type 3R dimensions *NEMA 4X & 12 enclosures available upon request 7