Strutting Beams Supporting Underpurlins Only

Similar documents
01 CONTENTS. e-beam. e-beam. Technical Information 03

JD3 rated for greater connection strength. makes it easy to spot in the warehouse or on site

Span guide for residential framing. September Fully supported by

LINTELS WITH TG. Single Spans. Lintels Supporting Truncated Girder Truss INCLUDES TG Set Back 2.4m Maximum 40 kg/m 2 90 kg/m 2

SHAPING THE FUTURE OF FORMWORK SHAPING THE FUTURE OF FORMWORK

INDEX OF W.T.I. BEAMS

SPAN TABLES FOR RESIDENTIAL BUILDING NOW AVAILABLE H2-S TREATED TO PROTECT AGAINST TERMITES

RAFTERS. Single and Continuous Spans

Formwork Solutions Guide

SmartLVL 18 Design Guide

Prolam LVL 15 Design Guide. Register Free for our Beam Calculator

Meypine. Handy Span Guide

Product grading of all members is compliant with AS1720: Timber Structures.

SPAN TABLES SPAN TABLES

SmartFrame Product Warranty*

SmartLam GL18 Design Guide

GP Lam LVL. (20!and 22! by special order) 13 4! 31 2! 1.5E. Lengths: up to 60 feet. Referenced dimensions are nominal and used for design purposes.

1¾" BEAMS & HEADERS. [1¾" THICKNESS] NER F b E Design Values LAMINATED VENEER LUMBER. Finnforest USA, Engineered Wood Division

GP Lam LVL. Grade Thickness Depth , , , , , 149, 169, 189, 249 (209and 229 by special order) 2.

GP Lam LVL. Grade Thickness Depth , 9 1 4, 9 1 2, , , 14, 16, 18, 24 (20 and 22 by special order) 2.

SmartLVL15 Design Guide

Maximum Span Tables. for Joists and Rafters. MSR Lumber. for Performance. Figure provided courtesy of the American Forest & Paper Association

2.0E ES LVL U.S. Design Manual

LP SolidStart Engineered Wood Products

COMMERCIAL & INDUSTRIAL FLOORING DESIGN EWPAA

WESTERN SPECIFIER. Technical Data for PWI Joists, PWLVL Headers, Beams, Rim Board, Stud, and Dimension

Bending strength, density and modulus of elasticity of BauBuche laminated veneer lumber in comparison with other materials.

Technical Data Sheet Timber Decks Commercial, Industrial & Marine 7

TECHNICAL DATA SHEET ISSUED BY TIMBER QUEENSLAND TIMBER DECKS

SmartLam GL 17 Design Guide

TRUS JOIST BEAMS, HEADERS, AND COLUMNS

National Evaluation Service, Inc.

Requirements for Use of Allowable Load Tables

Anthony Glulam Advantages

Allowable Holes in VERSA-LAM Beams

ROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS DESIGN GUIDE PURLINS AND GIRTS S&T029N

western for products manufactured in White City, Oregon

WESTERN SPECIFIER GUIDE. for products manufactured in White City, Oregon

BOISE GLULAM Beam and Column Specifier Guide

Rosboro TM. Next-Generation Glulam. n Architectural Appearance. n Full Framing-Width Stock. Glulam. n I-Joist and Conventional.

Model H100 - H400 EXPLODED VIEW TECHNICAL DATA SHEET ALUMUNIUM DOME. GLASS REINFORCED NYLON 6 BEARING HOLDER & HOLDER ARMS (MODEL H300 & H400 only)

Model S S2 400

Premium Structural Engineered Wood Products. Technical Data for. LVL Flange and MSR Flange I-Joists

BOISE GLULAM 24F-V4 IJC

DESIGN CHART # 1: Lamit Basic S.I.P Properties

This technical bulletin aims to supplement the information relating to holes in the web of James Jones I- Joists given in the Technical Manual.

Design principles and Assumptions

MINI. Technical Data for. PWI Joists, PWLVL Headers, Beams, and Dimension

mini orb w.a. design and installation guide

APPENDIX D. D.1 Macalloy Bars. Approximate safe working loads (kn) Appendix D - Proprietary Components (1/9) Stainless steel architectural ties

NEW RESIDENCE - Sample Takeoff UpState Estimating / Material Takeoff

Purlins and Girts. A division of Canam Group

Trade Brochure & Price List 2015/16

PLANK-AND-BEAM FRAMING FOR RESIDENTIAL BUILDINGS

LVL User s Guide. Technical Data for LVL Headers, Beams, Column Applications for Residential Floor and Roof Systems

Load Bearing Capacity lb kg. Type of Surface Fibreglass bonded on steel. Clearance (Inclined roof) 22 9 to to 7.

GENERAL INFORMATION FEATURES.

Standard Range Sheds / Workshops SPECIFICATION

Length and Depth 42 4 x x m Clearance (Inclined roof) 22 9 to to 7.76 m Maximum Height from Banners

Kark Residence Page 1 of 6

STREAMLINED SOLAR CHECKLIST Owner Name:

Trusted ICC ES. Conformity! Look. Evaluation. ICC-ES Evaluation

NEW ZEALAND GLULAM SPAN TABLES

Testing of Baier Plasterboard to AS/NZS (Electronic copy (PDF format) original signed by author) Materials Scientist.

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council

ADDENDUM DOOR COMPATIBILITY FOR MODEL 3950

Rosboro Manufactured Timber. Preferred lengths Dry stable timber Full-Framing Width

Multideck 50-V2 Features and Applications

CELEBRATING 32 YEARS PRICE LIST. JANUARY 2018 All prices exclude VAT. Members Number WE MANUFACTURE FREE

a space for life WEAVER BARNS PRICE LIST 2016

Commercial Hopper Tanks (CHT)

Mirage Series Span Table

4.5 COMPOSITE STEEL AND CONCRETE

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued May 1, Legacy report on the 1997 Uniform Building Code

Roof Lifting Capacity 3800 lb 1725 kg. Type of Surface Fibreglass bonded on aluminiun. Clearance (Inclined roof) 14 7 to to 3.

Quick Selection Guide

Spruce Line photovoltaic modules

FireFree ScandiBoard 850 Passive Fire Protection of Steel Constructions R30 - R180

The design superimposed load combination is G SDL + Q and must not be greater than the superimposed loads given in the tables.

Structural. Guide. Inside this

Ajax ISO. Centrifugal Pump ISO Application Application. Designation Designation. Operating Data - 50 Hz. Design. Type Series Booklet

Company name: Created by: Phone: Note! Product picture may differ from actual product

Heating with a. Difference. Now Available. Keeping Australia Warm! LOW EMISSION HIGH EFFICIENCY SERIES 8 RANGE. Up to 72% As low as 1.

Lifting Capacity 8000 lb 3626 kg. Type of Surface Fibreglass bonded on steel. Clearance (Inclined roof) 18 1 to m to 5.

Length and Depth 31 8 x x 8.26 m Clearance (Inclined roof) 14 6 to to 5.15 m Maximum Height from Ground

CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.

GETO City body kit A high-performance solution for Sprinter Class vehicles

Timber RETAIL PRICE LIST SUPPLYING WA BUILDINGS SINCE 1981

LINK-BELT MODEL HTC-8675LB - 75 TON CAPACITY 48 7" (.80m) 41 0" /8" (3.52m) /16" (2.02m) /4" (.34m) 25" 11 0" (.

WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL

Dimensions - Z Sections. Dimensions - C Sections

DeltaStud - Lightweight Steel Framing

ENLIGHTENED LIVING RESIDENTIAL SKYLIGHTS E-CLASS CURB-MOUNT ARCHITECTURAL SERIES

Lenght and Depth 34 5 x x 8.41 m Clearance (Inclined roof) 20 to m to 5.42 m Maximum Height with Banner

9120 EBCU Battery Charger MODELS: 9120EBCU96V 9120EBCU240V

Distributed by SPECIALISED RUBBER PRODUCTS. Donut Springs Spring Covers Rubber Bumpers Tensions Bands

2013 IOWA FFA AGRICULTURAL MECHANICS CAREER DEVELOPMENT EVENT WRITTEN EXAMINATION

REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS 9050 CENTRE POINTE DRIVE, SUITE 400 WEST CHESTER, OHIO EVALUATION SUBJECT:

DESIGN TABLE OF PURLIN, GIRT, EAVE BEAM, TIE RUNNER

MODEL ERH-40J171 2 BEDROOM, 1 BATH NOMINAL SIZE: 28 X40 TOTAL AREA: 960 SQ. FT.

Transcription:

Strutting Beams Supporting Underpurlins Only fan struts strutting beam roof area supported by strutting beam = L/2 x B/2 block underpurlin strutting beam strut L = total rafter span strutting beam span B = total span of underpurlin 2

Strutting Beams Supporting Underpurlins Only WInd Classification N3 Limits on deflection Dead load: span/300 or 20mm max. Live load: span/250 or 20mm max. e-beam Section D X B (mm) Roof Area supported (m 2 ) 2 3 4 5 6 7 8 10 12 Maximum Span (m) Sheet Roof 150 x 45# 4.0 3.7 3.2 2.9 2.7 2.5 2.3 2.1 NS 150 x 63 4.7 4.2 3.7 3.4 3.1 2.9 2.7 2.5 2.3 2/150 x 35# 5.0 4.4 3.9 3.6 3.3 3.1 2.9 2.6 2.4 170 x 45# 4.8 4.3 3.8 3.5 3.2 3.0 2.8 2.5 2.2 170 x 63 5.4 4.9 4.4 4.0 3.7 3.5 3.3 2.9 2.7 200 x 63# 6.4 6.0 5.5 5.0 4.7 4.4 4.1 3.7 3.4 2/200 x 35# 6.7 6.2 5.7 5.3 4.9 4.6 4.3 3.8 3.3 2/200 x 45# 7.0 6.5 6.1 5.7 5.4 5.1 4.8 4.4 4.0 240 x 45# 6.9 6.5 6.1 5.6 5.2 4.9 4.5 3.9 3.5 240 x 63# 7.5 7.0 6.6 6.2 5.9 5.6 5.3 4.8 4.4 2/240 x 45# 7.9 7.5 7.1 6.8 6.5 6.3 6.1 5.6 5.2 300 x 63 8.9 8.3 7.9 7.5 7.2 7.0 6.7 6.4 6.0 300 x 75 9.1 8.6 8.2 7.8 7.5 7.3 7.0 6.7 6.3 300 x 82 9.2 8.6 8.4 8.1 7.8 7.6 7.4 6.6 6.1 360 x 63 10.0 9.5 9.1 8.7 8.4 8.2 7.9 7.5 7.1 400 x 63 10.7 10.3 9.9 9.5 9.2 8.9 8.6 8.2 7.8 400 x 75 10.9 10.5 10.1 9.8 9.5 9.2 9.0 8.5 8.2 400 x 82 11.1 10.7 10.3 10.0 9.8 9.5 9.3 8.8 8.5 450 x 63 11.6 11.1 10.7 10.4 10.1 9.8 9.5 9.1 8.7 450 x 82 12.6 12.1 11.6 11.3 11.0 10.7 10.3 9.9 9.1 Tile Roof 150 x 45# 3.0 2.5 2.2 NS NS NS NS NS NS 150 x 63 3.5 2.9 2.5 2.3 2.1 NS NS NS NS 2/150 x 35# 3.7 3.1 2.7 2.4 2.2 2.1 NS NS NS 170 x 45# 3.6 3.0 2.6 2.3 2.1 2.0 1.9 NS NS 170 x 63 4.1 3.5 3.0 2.7 2.5 2.3 2.2 2.0 NS 200 x 63# 5.2 4.4 3.8 3.5 3.2 3.0 2.8 2.5 2.3 2/200 x 35# 5.4 4.6 4.1 3.7 3.4 3.2 3.0 2.7 2.4 2/200 x 45# 5.9 5.1 4.5 4.1 3.8 3.5 3.3 3.0 2.7 240 x 45# 5.7 4.9 4.3 3.9 3.5 3.3 3.1 2.8 2.5 240 x 63# 6.3 5.6 5.0 4.5 4.1 3.9 3.6 3.3 3.0 2/240 x 45# 6.9 6.3 5.7 5.3 4.9 4.5 4.3 3.9 3.5 300 x 63 7.7 7.0 6.5 6.1 5.7 5.3 5.0 4.5 4.1 300 x 75 7.9 7.3 6.8 6.4 6.1 5.7 5.4 4.9 4.5 300 x 82 8.2 7.6 7.1 6.7 6.4 6.1 5.8 5.3 4.9 360 x 63 8.9 8.2 7.6 7.2 6.8 6.6 6.3 5.9 5.4 400 x 63 9.6 8.9 8.3 7.9 7.5 7.2 7.0 6.5 6.2 400 x 75 9.9 9.2 8.7 8.2 7.9 7.6 7.3 6.9 6.5 400 x 82 10.1 9.5 9.1 8.5 8.3 7.9 7.6 7.2 6.8 450 x 63 10.5 9.8 9.2 8.8 8.4 8.0 7.8 7.3 6.9 450 x 82 11.4 10.7 10.0 9.6 9.1 8.7 8.5 7.9 7.5 e-maximus LVL 1. All sections with depth to breadth ratio greater than three must be laterally restrained against rollover at mid-span, strutting points and at supports as per AS1684. 2. A minimum initial clearance of 25mm to ceiling framing member shall be provided at mid-span. 3. Bearing lengths at end supports shall not be less than 65mm. 4. Beam ends may be chamfer cut to a minimum depth of 90mm or D/3, whichever is the greater. 3

Counter Beams Supporting Hanging Beams counter beam CLW = ( H 1 + H 2 ) / 2 hanging beam spans H 1 H 2 counter beam span hanging beam 4

Counter Beams Supporting Hanging Beams WInd Classification N3 Limits on deflection Dead load: span/300 or 15mm max. Live load: span/270 or 15mm max. e-beam Section D X B (mm) Ceiling Load Width CLW (m) 1.8 2.4 3.0 3.6 4.2 4.8 5.4 6.0 Maximum Span (m) 150 x 35 3.8 3.4 3.2 3.0 2.9 2.8 2.7 2.6 150 x 45 4.0 3.7 3.4 3.3 3.1 3.0 2.9 2.8 170 x 35 4.2 3.9 3.6 3.4 3.3 3.1 3.0 2.8 170 x 45 4.5 4.2 3.9 3.7 3.5 3.4 3.2 3.1 200 x 35 4.8 4.4 4.1 3.8 3.6 3.5 3.2 3.1 200 x 45 5.1 4.8 4.5 4.3 4.1 3.9 3.8 3.7 200 x 63 5.4 5.1 4.9 4.7 4.5 4.4 4.2 4.1 240 x 35 5.2 4.8 4.4 4.1 4.0 3.8 3.6 3.5 240 x 45 5.8 5.4 5.2 5.0 4.8 4.6 4.3 4.2 240 x 63 6.1 5.8 5.6 5.3 5.2 5.0 4.9 4.8 300 x 45 6.7 6.4 6.0 5.6 5.3 5.1 4.8 4.7 300 x 63 7.1 6.8 6.5 6.3 6.1 5.9 5.7 5.6 300 x 75 7.4 7.0 6.7 6.5 6.3 6.1 6.0 5.8 300 x 82 7.6 7.2 6.9 6.7 6.5 6.3 6.2 6.0 360 x 63 8.1 7.7 7.4 7.1 6.9 6.7 6.5 6.4 400 x 63 8.7 8.3 7.9 7.7 7.4 7.2 7.1 6.9 400 x 75 8.9 8.5 8.2 7.9 7.7 7.5 7.3 7.2 400 x 82 9.1 8.7 8.4 8.1 7.9 7.7 7.5 7.3 450 x 63 9.4 8.9 8.6 8.3 8.1 7.9 7.7 7.4 450 x 82 10.0 9.7 9.4 9.0 8.8 8.6 8.4 8.0 e-maximus LVL 1. Average Hanging Beam Span = (H1 + H2)/2, where H1 and H2 are the spans of the hanging beams on each side of the Strutting-Counter beam. 2. All sections with depth to breath ratio exceeding three must be restrained against rollover as per AS1684. 3. Bearing lengths at end supports to be not less than 65mm. 4. Beam ends may be chamfer cut to a minimum depth of 90mm or D/3, whichever is greater. 5

Strutting Hanging Beams Supporting Underpurlins and Ceiling Joists strut L = total rafter span underpurlin strutting-hanging beam W = total ceiling joist span both sides of the strutting beam roof load width (RLW) = L/2 ceiling load width (CLW) = W/2 6

Strutting Hanging Beams Supporting Underpurlins and Ceiling Joists e-beam Section D X B (mm) Ceiling Load Width CLW (m) WInd Classification N3 Limits on deflection Dead load: span/300 or 12mm max. Live load: span/300 or 12mm max. 1.8 2.4 3.0 Roof Load Width RLW for underpurlin (m) 1.8 2.4 3.0 3.6 1.8 2.4 3.0 3.6 1.8 2.4 3.0 3.6 Maximum Span for Sheet Roof & Ceiling (m) 170 x 63 3.8 3.6 3.4 3.3 3.6 3.5 3.3 3.2 3.5 3.3 3.2 3.1 2/170 x 35 3.9 3.7 3.6 3.4 3.7 3.6 3.5 3.3 3.6 3.5 3.3 3.2 2/170 x 45 4.1 3.9 3.8 3.7 3.9 3.8 3.7 3.6 3.8 3.7 3.6 3.5 200 x 63 4.2 4.1 3.9 3.8 4.1 3.9 3.8 3.7 3.9 3.8 3.7 3.6 2/200 x 35 4.4 4.2 4.0 3.9 4.2 4.1 3.9 3.8 4.1 3.9 3.8 3.7 2/200 x 45 4.6 4.4 4.2 4.1 4.4 4.3 4.1 4.0 4.3 4.1 4.0 3.9 240 x 45 4.5 4.3 4.1 4.0 4.3 4.2 4.0 3.9 4.2 4.0 3.9 3.8 240 x 63 4.8 4.6 4.5 4.3 4.7 4.5 4.4 4.2 4.5 4.4 4.2 4.1 2/240 x 45 5.2 5.0 4.8 4.7 5.0 4.9 4.7 4.6 4.9 4.7 4.6 4.5 300 x 63 5.7 5.4 5.3 5.1 5.5 5.3 5.1 5.0 5.3 5.1 5.0 4.9 300 x 75 5.9 5.7 5.5 5.3 5.7 5.5 5.3 5.2 5.5 5.3 5.2 5.1 2/300 x 45 6.1 5.9 5.7 5.5 5.9 5.7 5.5 5.4 5.7 5.6 5.4 5.3 300 x 63 5.5 5.3 5.1 5.0 5.3 5.1 5.0 4.9 5.1 5.0 4.9 4.8 300 x 75 5.7 5.5 5.3 5.2 5.5 5.3 5.2 5.1 5.3 5.2 5.1 5.0 300 x 82 5.9 5.7 5.5 5.4 5.7 5.6 5.4 5.3 5.5 5.4 5.3 5.2 360 x 63 6.2 6.0 5.8 5.7 6.0 5.9 5.7 5.6 5.8 5.7 5.6 5.4 400 x 63 6.7 6.4 6.3 6.1 6.5 6.3 6.2 6.0 6.3 6.1 6.0 5.9 400 x 75 7.0 6.7 6.6 6.4 6.8 6.6 6.4 6.2 6.6 6.4 6.2 6.1 400 x 82 7.2 7.0 6.8 6.6 7.0 6.8 6.6 6.5 6.8 6.6 6.5 6.4 450 x 63 7.3 7.1 6.9 6.7 7.1 6.9 6.7 6.5 6.9 6.7 6.5 6.4 450 x 82 8.2 7.9 7.6 7.4 7.9 7.7 7.5 7.3 7.7 7.5 7.3 7.1 Maximum Span for Tile Roof & Ceiling (m) 170 x 63 3.2 3.0 2.8 2.6 3.1 2.9 2.7 2.6 3.0 2.8 2.7 2.6 2/170 x 35 3.3 3.1 2.9 2.8 3.2 3.0 2.8 2.7 3.1 2.9 2.8 2.7 2/170 x 45 3.6 3.3 3.1 3.0 3.5 3.2 3.1 2.9 3.4 3.2 3.0 2.9 200 x 63 3.7 3.5 3.3 3.1 3.6 3.4 3.2 3.0 3.5 3.3 3.1 3.0 2/200 x 35 3.8 3.6 3.4 3.2 3.7 3.5 3.3 3.2 3.7 3.4 3.3 3.1 2/200 x 45 4.0 3.8 3.6 3.5 3.9 3.7 3.6 3.4 3.8 3.7 3.5 3.4 240 x 45 3.9 3.7 3.5 3.3 3.8 3.6 3.4 3.3 3.7 3.6 3.4 3.2 240 x 63 4.2 4.0 3.8 3.7 4.1 3.9 3.8 3.6 4.0 3.9 3.7 3.6 2/240 x 45 4.6 4.3 4.2 4.0 4.5 4.3 4.1 4.0 4.4 4.2 4.0 3.9 300 x 63 5.0 4.7 4.5 4.3 4.9 4.6 4.4 4.3 4.8 4.6 4.4 4.2 300 x 75 5.2 4.9 4.7 4.5 5.1 4.8 4.6 4.5 5.0 4.7 4.6 4.4 2/300 x 45 5.4 5.1 4.9 4.7 5.3 5.0 4.8 4.7 5.2 4.9 4.8 4.6 300 x 63 4.9 4.6 4.4 4.3 4.8 4.5 4.4 4.2 4.7 4.5 4.3 4.2 300 x 75 5.1 4.8 4.6 4.5 5.0 4.7 4.6 4.4 4.9 4.7 4.5 4.4 300 x 82 5.3 5.0 4.8 4.7 5.2 4.9 4.8 4.6 5.1 4.9 4.7 4.5 360 x 63 5.6 5.3 5.1 4.9 5.4 5.3 5.0 4.8 5.3 5.1 4.9 4.8 400 x 63 6.0 5.7 5.5 5.3 5.9 5.6 5.4 5.2 5.8 5.5 5.3 5.2 400 x 75 6.2 5.9 5.7 5.5 6.1 5.8 5.6 5.5 6.0 5.7 5.5 5.4 400 x 82 6.5 6.2 6.0 5.8 6.4 6.1 5.9 5.7 6.2 6.0 5.8 5.6 450 x 63 6.5 6.2 6.0 5.8 6.4 6.1 5.9 5.7 6.3 6.0 5.8 5.6 450 x 82 7.3 6.9 6.6 6.4 7.1 6.7 6.5 6.3 7.0 6.6 6.4 6.2 e-maximus LVL 1. All sections with depth to breath ratio s exceeding three must be restrained against rollover as per AS1684. 2. Roof Load Width RLW for the underpurlin is the average of the rafter spans either side of the underpurlin supported by the Strutting-Hanging beam. 3. Underpurlin span assumed to be one-half of the Strutting-Hanging beam span. 4. Ceiling Load width CLW is the average of the ceiling joist spans either side of the Strutting-Hanging beam. 5. Bearing lengths at end supports to be not less than 65mm. 6. Beam ends may be chamfer cut to a minimum depth of 90mm or D/3, whichever is greater. 7

Strutting Counter Beams Supporting Underpurlins and Hanging Beams strutting-counter beam average hanging beam span = ( H 1 + H 2 ) / 2 hanging beam spans H 1 H 2 roof area supported by strutting beam = L/2 x B/2 underpurlin strut hanging beam L = total rafter span strutting beam span B = total span of underpurlin 8

Strutting Counter Beams Supporting Underpurlins and Hanging Beams WInd Classification N3 Limits on deflection Dead load: span/300 or 12mm max. Live load: span/300 or 12mm max. e-beam Section D X B (mm) Maximum Span for Sheet Roof & Ceiling (m) Average Hanging Beam Span (m) 2.4 4.2 Roof area supported (m 2 ) 2 4 6 8 10 12 2 4 6 8 10 12 170 x 63 4.0 3.6 3.3 3.0 2.7 2.6 3.7 3.3 3.1 2.8 2.6 2.5 2/170 x 35 4.1 3.8 3.5 3.2 2.9 2.7 3.8 3.5 3.2 3.0 2.8 2.6 2/170 x 45 4.3 4.0 3.7 3.5 3.2 3.0 4.0 3.7 3.5 3.3 3.1 2.9 200 x 63 4.5 4.2 3.9 3.7 3.4 3.2 4.2 3.9 3.7 3.5 3.2 3.1 2/200 x 35 4.7 4.3 4.0 3.8 3.6 3.4 4.3 4.0 3.8 3.6 3.4 3.2 2/200 x 45 4.9 4.5 4.3 4.0 3.8 3.7 4.5 4.3 4.0 3.9 3.7 3.6 240 x 45 4.8 4.4 4.1 3.9 3.7 3.5 4.4 4.1 3.9 3.7 3.6 3.4 240 x 63 5.2 4.8 4.5 4.3 4.1 3.9 4.8 4.5 4.3 4.1 3.9 3.8 2/240 x 45 5.6 5.2 5.0 4.7 4.5 4.3 5.1 4.9 4.7 4.5 4.3 4.2 300 x 63 6.1 5.7 5.4 5.2 5.0 4.8 5.6 5.3 5.1 4.9 4.7 4.6 300 x 75 6.3 6.0 5.7 5.4 5.2 5.0 5.8 5.5 5.3 5.1 5.0 4.8 300 x 82 6.5 6.2 5.9 5.7 5.5 5.3 6.0 5.8 5.6 5.4 5.2 5.1 360 x 63 6.9 6.6 6.3 6.0 5.8 5.6 6.3 6.1 5.9 5.7 5.5 5.4 400 x 63 7.4 7.1 6.8 6.6 6.3 6.1 6.8 6.6 6.4 6.2 6.0 5.8 400 x 75 7.7 7.4 7.1 6.8 6.6 6.4 7.1 6.8 6.6 6.4 6.3 6.1 400 x 82 7.9 7.6 7.3 7.1 6.9 6.7 7.3 7.1 6.9 6.7 6.5 6.4 450 x 63 8.1 7.7 7.4 7.2 7.0 6.8 7.4 7.2 7.0 6.8 6.6 6.4 450 x 82 8.8 8.4 8.0 7.8 7.6 7.4 8.0 7.8 7.6 7.4 7.2 7.0 Maximum Span for Tile Roof & Ceiling (m) 170 x 63 3.5 2.8 2.4 2.1 1.9 NS 3.2 2.7 2.3 2.1 1.9 NS 2/170 x 35 3.7 3.0 2.6 2.3 2.0 1.9 3.4 2.8 2.5 2.2 2.0 1.9 2/170 x 45 3.9 3.3 2.8 2.5 2.3 2.1 3.7 3.1 2.7 2.4 2.2 2.1 200 x 63 4.1 3.5 3.0 2.7 2.4 2.2 3.8 3.3 2.9 2.6 2.4 2.2 2/200 x 35 4.2 3.7 3.2 2.8 2.6 2.4 4.0 3.5 3.1 2.8 2.5 2.3 2/200 x 45 4.4 3.9 3.5 3.1 2.9 2.6 4.2 3.8 3.4 3.1 2.8 2.6 240 x 45 4.3 3.8 3.3 3.0 2.7 2.5 4.1 3.6 3.2 2.9 2.6 2.4 240 x 63 4.7 4.1 3.8 3.4 3.1 2.9 4.4 4.0 3.7 3.3 3.1 2.8 2/240 x 45 5.1 4.6 4.2 3.9 3.7 3.4 4.8 4.4 4.1 3.8 3.6 3.3 300 x 63 5.6 5.0 4.6 4.3 4.1 3.9 5.3 4.8 4.5 4.2 4.0 3.8 300 x 75 5.9 5.3 4.8 4.5 4.3 4.1 5.5 5.0 4.7 4.4 4.2 4.0 300 x 82 6.1 5.5 5.1 4.8 4.5 4.3 5.7 5.3 4.9 4.6 4.4 4.2 360 x 63 6.5 5.9 5.4 5.1 4.8 4.6 6.0 5.6 5.2 4.9 4.7 4.5 400 x 63 7.0 6.4 5.9 5.6 5.3 5.0 6.5 6.1 5.7 5.4 5.1 4.9 400 x 75 7.3 6.7 6.2 5.9 5.6 5.3 6.8 6.3 6.0 5.7 5.4 5.2 400 x 82 7.5 7.0 6.5 6.1 5.8 5.5 7.0 6.6 6.2 5.9 5.6 5.4 450 x 63 8.7 8.2 7.7 7.4 7.1 6.8 8.1 7.7 7.4 7.1 6.9 6.6 450 x 82 8.3 7.6 7.2 6.7 6.4 6.1 7.7 7.3 6.9 6.5 6.2 6.0 e-maximus LVL 1. Average Hanging Beam Span = (H1 + H2)/2, where H1 and H2 are the spans of the hanging beams on each side of the Strutting-Counter beam. 2. All sections with depth to breath ratio exceeding three must be restrained against rollover as per AS1684. 3. Bearing lengths at end supports to be not less than 65mm. 4. Beam ends may be chamfer cut to a minimum depth of 90mm or D/3, whichever is greater. 9

Roof Beams Ridge, Intermediate, Eave and Bressummer Beams strut L = total rafter span underpurlin strutting-hanging beam W = total ceiling joist span both sides of the strutting beam roof load width (RLW) = L/2 ceiling load width (CLW) = W/2 10

Ridge Beam ridge beam rafter Intermediate Beam rafter intermediate beam Eave Beam rafter eave beam Bressumer trussed roof bressumer 11

Roof Beams Ridge, Intermediate, Eave and Bressummer Beams e-beam Section D X B (mm) Maximum Single Span (m) Sheet Roof and Ceiling Roof Load Width RLW (m) WInd Classification N3 Limits on deflection Dead load: span/300 Live load: span/250 Wind load: span/150 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.8 5.4 6.0 150 x 35 2.8 2.6 2.5 2.4 2.3 2.2 2.1 2.1 2.0 1.9 1.8 1.8 150 x 45 3.0 2.8 2.7 2.6 2.5 2.4 2.3 2.2 2.2 2.1 2.0 1.9 170 x 35 3.1 3.0 2.8 2.7 2.6 2.5 2.4 2.4 2.3 2.2 2.1 2.0 170 x 45 3.3 3.2 3.0 2.9 2.8 2.7 2.6 2.5 2.5 2.3 2.2 2.1 200 x 35 3.7 3.5 3.3 3.2 3.1 2.9 2.9 2.8 2.7 2.6 2.4 2.3 200 x 45 3.9 3.7 3.5 3.4 3.3 3.2 3.1 3.0 2.9 2.7 2.6 2.5 200 x 63 4.3 4.1 3.9 3.8 3.6 3.5 3.4 3.3 3.2 3.1 2.9 2.8 240 x 35 4.4 4.1 4.0 3.8 3.7 3.5 3.4 3.3 3.2 3.1 2.8 2.7 240 x 45 4.7 4.4 4.2 4.1 3.9 3.8 3.7 3.6 3.5 3.3 3.1 3.0 240 x 63 5.2 4.9 4.7 4.5 4.4 4.2 4.1 4.0 3.9 3.7 3.5 3.4 300 x 45 5.8 5.5 5.3 5.1 4.9 4.7 4.6 4.4 4.3 4.1 3.9 3.8 300 x 63 6.4 6.1 5.8 5.6 5.4 5.2 5.1 4.9 4.8 4.6 4.4 4.2 300 x 75 6.7 6.4 6.2 5.9 5.7 5.5 5.4 5.2 5.1 4.8 4.6 4.4 300 x 82 7.0 6.7 6.5 6.2 6.0 5.8 5.7 5.5 5.4 5.0 4.8 4.6 360 x 63 7.6 7.3 7.0 6.7 6.5 6.3 6.1 5.9 5.7 5.5 5.2 5.0 400 x 63 8.4 8.0 7.7 7.4 7.2 6.9 6.7 6.5 6.4 6.1 5.8 5.6 400 x 75 8.8 8.4 8.1 7.8 7.5 7.3 7.1 6.9 6.7 6.4 6.1 5.9 400 x 82 9.1 8.8 8.5 8.2 7.9 7.7 7.5 7.3 7.1 6.7 6.4 6.2 450 x 63 9.4 9.0 8.6 8.3 8.0 7.8 7.5 7.3 7.1 6.8 6.5 6.3 450 x 82 10.2 9.8 9.4 9.0 8.7 8.5 8.2 7.9 7.7 7.4 7.1 6.9 Maximum Continuous Span (m) 150 x 35 3.7 3.5 3.3 3.2 3.1 3.0 2.9 2.8 2.7 2.6 2.5 2.3 150 x 45 4.0 3.8 3.6 3.4 3.3 3.2 3.1 3.0 2.9 2.8 2.6 2.5 170 x 35 4.2 4.0 3.8 3.6 3.5 3.4 3.3 3.2 3.1 2.9 2.8 2.6 170 x 45 4.5 4.2 4.1 3.9 3.7 3.6 3.5 3.4 3.3 3.1 3.0 2.9 200 x 35 4.9 4.6 4.4 4.2 4.1 3.9 3.8 3.7 3.5 3.3 3.2 3.0 200 x 45 5.2 5.0 4.8 4.6 4.4 4.2 4.1 4.0 3.9 3.7 3.5 3.4 200 x 63 5.8 5.5 5.3 5.1 4.9 4.7 4.6 4.4 4.3 4.1 3.9 3.8 240 x 35 5.8 5.4 5.1 4.9 4.7 4.4 4.3 4.1 4.0 3.8 3.6 3.5 240 x 45 6.3 6.0 5.7 5.5 5.3 5.1 4.9 4.8 4.6 4.4 4.2 4.0 240 x 63 6.9 6.6 6.3 6.1 5.8 5.7 5.5 5.3 5.2 4.9 4.7 4.5 300 x 45 7.8 7.3 7.0 6.6 6.3 6.1 5.9 5.7 5.5 5.2 5.0 4.7 300 x 63 8.6 8.2 7.8 7.5 7.3 7.0 6.8 6.6 6.4 6.1 5.9 5.6 300 x 75 9.0 8.6 8.2 7.9 7.7 7.4 7.2 7.0 6.8 6.5 6.2 5.9 300 x 82 9.5 9.1 8.7 8.4 8.2 7.9 7.7 7.5 7.3 7.0 6.7 6.4 360 x 63 10.2 9.7 9.3 9.0 8.7 8.4 8.1 7.9 7.7 7.3 7.0 6.7 400 x 63 11.3 10.8 10.3 9.9 9.6 9.3 8.9 8.7 8.3 7.9 7.5 7.2 400 x 75 11.8 11.3 10.9 10.5 10.1 9.8 9.5 9.2 9.0 8.6 8.2 7.9 400 x 82 12.2 11.7 11.3 10.9 10.5 10.2 9.9 9.6 9.4 9.0 8.6 8.3 450 x 63 12.8 12.3 11.9 11.5 11.1 10.8 10.7 10.3 10.1 9.7 9.3 9.0 450 x 82 NS NS 12.9 12.4 11.9 11.6 11.2 10.9 10.6 10.2 9.7 9.3 e-maximus LVL For Tile Roof and Ceiling, see next page. 12

Roof Beams Ridge, Intermediate, Eave and Bressummer Beams e-beam Section D X B (mm) Maximum Single Span (m) Tile Roof and Ceiling Roof Load Width RLW (m) 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.8 5.4 6.0 150 x 35 2.2 2.0 1.9 1.9 1.8 1.7 1.7 1.6 1.6 1.5 1.5 1.4 150 x 45 2.3 2.2 2.1 2.0 1.9 1.9 1.8 1.8 1.7 1.6 1.6 1.5 170 x 35 2.4 2.3 2.2 2.1 2.0 2.0 1.9 1.9 1.8 1.7 1.7 1.6 170 x 45 2.6 2.5 2.4 2.3 2.2 2.1 2.1 2.0 2.0 1.9 1.8 1.7 200 x 35 2.9 2.7 2.6 2.5 2.4 2.3 2.3 2.2 2.1 2.0 1.8 1.8 200 x 45 3.1 2.9 2.8 2.7 2.6 2.5 2.4 2.4 2.3 2.2 2.1 2.0 200 x 63 3.4 3.3 3.1 3.0 2.9 2.8 2.7 2.6 2.6 2.4 2.3 2.3 240 x 35 3.4 3.3 3.1 3.0 2.9 2.7 2.6 2.5 2.4 2.2 2.0 1.9 240 x 45 3.7 3.5 3.3 3.2 3.1 3.0 2.9 2.8 2.8 2.6 2.5 2.4 240 x 63 4.1 3.9 3.7 3.6 3.5 3.3 3.2 3.2 3.1 2.9 2.8 2.7 300 x 45 4.6 4.4 4.2 4.0 3.9 3.7 3.6 3.5 3.4 3.3 3.1 3.0 300 x 63 5.1 4.8 4.6 4.5 4.3 4.2 4.0 3.9 3.8 3.7 3.5 3.4 300 x 75 5.4 5.1 4.9 4.7 4.5 4.4 4.3 4.2 4.1 3.9 3.7 3.6 300 x 82 5.7 5.4 5.2 4.9 4.7 4.6 4.5 4.4 4.3 4.1 3.9 3.8 360 x 63 6.1 5.8 5.5 5.3 5.2 5.0 4.8 4.7 4.6 4.4 4.2 4.0 400 x 63 6.7 6.4 6.1 5.9 5.7 5.5 5.4 5.2 5.1 4.9 4.7 4.5 400 x 75 7.1 6.8 6.5 6.2 6.0 5.8 5.7 5.5 5.4 5.1 4.9 4.7 400 x 82 7.4 7.2 6.9 6.6 6.3 6.1 6.0 5.8 5.7 5.4 5.1 4.9 450 x 63 7.6 7.2 6.9 6.6 6.4 6.2 6.0 5.9 5.7 5.5 5.2 5.0 450 x 82 8.3 7.9 7.5 7.2 7.0 6.8 6.5 6.4 6.2 6.0 5.7 5.5 Maximum Continuous Span (m) 150 x 35 2.9 2.7 2.6 2.5 2.4 2.3 2.3 2.2 2.1 2.0 1.9 1.8 150 x 45 3.1 2.9 2.8 2.7 2.6 2.5 2.4 2.4 2.3 2.2 2.1 2.0 170 x 35 3.3 3.1 3.0 2.8 2.7 2.6 2.6 2.5 2.4 2.3 2.1 2.0 170 x 45 3.5 3.3 3.2 3.1 2.9 2.9 2.8 2.7 2.6 2.5 2.4 2.3 200 x 35 3.8 3.6 3.5 3.3 3.2 3.1 3.0 2.9 2.8 2.6 2.5 2.3 200 x 45 4.1 3.9 3.7 3.6 3.5 3.4 3.2 3.2 3.1 2.9 2.8 2.7 200 x 63 4.6 4.4 4.2 4.0 3.9 3.7 3.6 3.5 3.4 3.3 3.1 3.0 240 x 35 4.6 4.4 4.1 3.9 3.8 3.5 3.4 3.3 3.2 3.0 2.8 2.6 240 x 45 4.9 4.7 4.5 4.3 4.2 4.0 3.9 3.8 3.7 3.5 3.4 3.1 300 x 63 6.8 6.5 6.2 6.0 5.8 5.6 5.4 5.3 5.1 4.9 4.7 4.5 300 x 75 7.2 6.9 6.6 6.3 6.1 5.9 5.7 5.6 5.4 5.2 5.0 4.8 300 x 82 7.7 7.4 7.1 6.8 6.6 6.4 6.2 6.1 6.0 5.8 5.6 5.4 360 x 63 8.2 7.8 7.4 7.2 6.9 6.7 6.5 6.3 6.2 5.9 5.6 5.3 400 x 63 9.0 8.6 8.2 7.9 7.7 7.4 7.1 6.9 6.7 6.3 5.9 5.7 400 x 75 9.5 9.1 8.7 8.4 8.1 7.8 7.5 7.4 7.2 6.9 6.6 6.4 400 x 82 10.0 9.6 9.2 8.9 8.6 8.3 8.0 7.9 7.7 7.4 7.1 6.9 450 x 63 10.6 10.2 9.8 9.5 9.1 8.9 8.6 8.5 8.2 8.0 7.6 7.5 450 x 82 10.4 9.9 9.5 9.2 8.8 8.5 8.3 8.1 7.9 7.5 7.2 7.0 e-maximus LVL WInd Classification N3 Limits on deflection Dead load: span/300 Live load: span/250 Wind load: span/150 1. The above Span Tables for Roof Beams assume no lateral restraint to the bottom edge under wind uplift conditions. 2. Bearing lengths at end supports to be not less than 65mm. 13

14

15

specification Veneer Thickness Constant through the product thickness Species Plantation timber Joints Outer 2 plies are scarf jointed Inner plies scarf and/or butt jointed Moisture Content 8% 15% (at time of despatch) Dimensional Tolerances Available on request Straightness Available on request Density 650 kg/m³ (approximately) Adhesive Phenolic AS 2754.1 Bond Type A AS/NZS 2098.2 Joint Group JD3 for nails, bolts and screws Finish Pre-primed to provide a defect free surface ready to top coat without any further preparation. Edges arrised. Branding Each piece of Wesbeam LVL is branded as least once with the product name for identification and evidence of compliance with manufacturing control standards Storage Store on level bearers at maximum 1800mm centres well clear of the ground, and cover to keep dry but allow ventilation Source Plantation timber certified to AS4707-2006/PEFC Condition Treated to H3 Level as per AS/NZS 1604.4 Wesbeam Pty Limited ABN 89 004 268 017 Date of publication: August 2016 PO Box 217 Wanneroo, WA 6946 190 Pederick Road Neerabup, WA 6031 Australia T (08) 9306 0400 F (08) 9306 0444 E wesbeam@wesbeam.com W www.wesbeam.com