Low Surge Special WCAg contact limits the chopping current up to 1A to protect the load from high surge.

Similar documents
High voltage vacuum contactors

Ensuring excellent switching capability and high quality with various advantages

Contactor V-Contact VSC/P

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

22AF 40AF AF 150AF 225AF 400AF 800AF

AF series contactors (9 2650)

Contactor-Fuse Combination 3TL62 / 63 / 66

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Air-insulated switchgear UniGear type ZS1

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

General data 5/37. Overview

AF series contactors (9 2650)

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage

Metal Clad Air Insulated Switchgear

We build a better future!

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

JOSLYN CLARK VACUUM CONTACTOR FEATURES

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

3TM Vacuum Contactors

Pro-MEC Vacuum Circuit Breakers Vacuum Interrupter

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Medium Voltage Metal-Enclosed Switches

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

Technical Information

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Memshield - ACB Ratings & Specifications

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

Gas Insulated Metal-clad Switchgear, HMGS!

Power systems Protection course

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Meta Solution. Contactors and Overload relays

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

Electronic circuit breaker EBU10-T

Medium Voltage Metal-Enclosed Switches

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

W-SLC Medium Voltage fused contactor truck A safe, reliable and efficient motor starter

AF40... AF96 3-pole contactors Technical data

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

PIX-H Metal-clad switchgear up to 17.5kV

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Powering business worldwide

Ktec Contactors and thermal overloads

Low & Medium Voltage Vacuum Contactors

Vacuum Circuit Breaker

CPG.0 Single busbar gas-insulated cubicles

B4 Load Break Switches

SafeGear TM Motor Control Center Arc resistant metal-clad construction

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

EMPAC Metal enclosed capacitor bank for wind applications

Motor Protection Circuit Breakers

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Short form catalogue. Motor protection & control

Vacuum Circuit Breaker VS1

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

Meta Solution. Contactors and Overload relays

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

NXPLUS C Single busbar. Maintenance-free for lifetime

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

ASL09..S 3-pole Contactors - Spring Terminals

TECHNICAL DESCRIPTION

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

3 - Protection components Motor circuit-breakers

Horizontal Circuit Switchers

Unitole UP kv Primary substations Motor control centres

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

(Example) In case of DC24 to 48V, it is operating time for DC24V.

Unitole UP kv Primary substations Motor control centres

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

CI-TI Contactors and motor starters Types CI 61 - CI 98

Medium voltage vacuum circuit breaker. E-VAC series

Motor-drive mechanism, type BUL. Technical guide

Contactors. CT1115/04, CT1130/04 CT1215/04, CT1230/04 CT1315/04, CT1330/04 1, 2 and 3 pole power contactors for AC and DC Catalogue C20.

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

3VU13, 3VU16 Circuit-Breakers

JOSLYN CLARK VACUUM CONTACTORS

ACS motor protection circuit breakers KT 7 Introduction

Star Series Motor protection & control

H.V. Distribution Equipment Vacuum circuit breakers New-Auto. V


Protection Equipment

MS Overview. General purpose contactors. MS Overview. General purpose contactors. The main benefits: Handling of the contactors

Section Contents. 1. Introduction 2-5. Salient features, internal & general appearance of Drawout ACB

Transcription:

Vacuum Contactor HYUNDAI Vacuum Contactors are designed and manufactured for frequent switchings, especially taking into account safety and quality assurance. They are suitable for switching and controlling squirrel cage and slipring motors, medium voltage loads and resistance furnaces, and capacitors and transformers.

[ CONTENTS ] Features / Operation and Application 04 Ⅰ Ratings 05 Technical Data 06 Ⅰ Accessories 10 Ⅰ Circuit Diagrams 11 Dimensions 12 Ⅰ Order Information 18

VC Vacuum Contactor >> Features Superior Switching Performance Switching a vacuum makes for rapid breaking. Rapid buildup of the dielectric strength ensures safety breaking. The fuse mounted type also provides for protection against shortcircuit currents. Optimum Design Optimized structure and mechanism complement frequent switching. Low Surge Special WCAg contact limits the chopping current up to 1A to protect the load from high surge. High Reliability Rigid insulation frame and operating mechanism offer high reliability, especially for safety and quality assurance. Customer Convenience Light weight and compact size enable easy installation with high efficiency in space. Optimum design makes maintenance convenient. >> Operation and Application Continuously Energized Type Having longer mechanical life time than a latched type, more suitable for frequent switching. When the transformer for controlling power fails to supply power due to accidents, continuously energized type protects the loads by tripping automatically. Latched Type Latched type keeps the closing condition without the supply of power, so it is suitable for the system which has unstable power or the load which requires automatic closing with power. With the separate tripping circuit, DC control voltage is recommended for stable power supply. When AC control voltage is used, the CTD(condesor trip device) should be installed. [ 3.6/ M1 cradle ] [ 3.6/ E1/F1 cradle] 5 6 7 8 1 2 3 1 2 9 3 4 4 [ Continuously energized type] [ Latched type] ON/OFF indicator Counter Control jack Drawout mechanism Fuse Fuse holder Fuse melting detector (Optional) Manual checking hole (Latched type only) Trip button (Latched type only) 4

HCA Type >> Ratings Qualified Standard & Approval Standard IEC 60470 NEMA ICS 3 Approval KR/Korea Korean Register of Shipping GL/Germany Germanischer Lloyd LR/U.K Lloyd s Register of Shipping NK/Japan Nippon Kaiji Kyokai Type Fixed type F Without fuse holder A With single fuse holder J With double fuse holder 1) Drawout type B Without fuse holder D With single fuse holder H With double fuse holder 1) Operating method Continuously energized Latched 32C 34C 62C 64C 82C 84C 32C 34C 62C 64C 82C 84C 32L 34L 62L 64L 82L 84L 32L 34L 62L 64L 82L 84L Rated insulation voltage (kv) Rated operation voltage (kv) Rated frequency (Hz) Rated current (A) 3.6 7.2 12 3.6 7.2 12 3.3 6.6 11 3.3 6.6 11 50/60 200 400 200 400 200 400 200 400 200 400 200 400 Withstand voltage Impulse (kv) Power frequency (1min, kv) 45 60 75 45 60 75 16 20 28 16 20 28 Control dielectric strength(min, kv) Utilization category Breaking capacity 2 2 2 2 2 2 AC3 AC4 AC3 AC4 4kA (O3minCO3minCO) Shorttime current (ka) Mechanical life time 1 sec 30 sec Continuously energized (1,000 times) Latched (1,000 times) 6.3 6.3 6.3 6.3 6.3 6.3 2.4 2.4 2.4 2.4 2.4 2.4 1,000 1,000 1,000 1,000 1,000 1,000 250 250 250 250 250 250 Electrical lifetime (1,000 times) Control voltage (V) Auxiliary contact 300 AC110/220, DC110/220 2a2b 2) 5a5b Applicable load capacity Motor (kw) Transformer (kva) Condensor (kvar) 750 1,500 1,500 3,000 3,000 6,000 750 1,500 1,500 3,000 3,000 6,000 1,000 2,000 2,000 4,000 4,000 8,000 1,000 2,000 2,000 4,000 4,000 8,000 750 1,200 1,500 2,000 3,000 4,000 750 1,200 1,500 2,000 3,000 4,000 F 21 F 22 F 61 B 383) B 413) B 80 4) Weight without fuse(kg) A 30 A 32 A 68 D 403) D 433) D 834) J 33 J 35 H 433) H 463) 1) Double fuse holder is not applicable to. 2) In case of 3.6/ fixed type without fuse, 3a3b is standard. 3) The weight of 3.6/ drawout type is based on F1 cradle. 4) The weight of drawout type is measured without cradle. 5

VC Vacuum Contactor >> Technical Data Operating Time and Current Closing current (A) 3.6/ Holding current (A) 3.6/ Opening current (A) Closing time (ms) Opening time (ms) Continuously energized type DC110V DC220V AC110V AC220V 2.5 1.6 2.0 1.0 10.0 10.0 10.0 10.0 1.0 0.7 0.8 0.5 3.0 3.0 3.0 3.0 Max. 80 Max. 80 Max. 40 Max. 40 Latched type DC110V DV220V AC110V AC220V 2.7 1.7 1.9 1.2 10.0 10.0 10.0 10.0 5.0 4.0 3.5 3.0 Max. 120 Max. 120 Max. 25 Max. 25 Control Voltage Rated Current of Auxiliary Contact Closing 85 110% of rated voltage AC110V 5A Opening 70 110% of rated voltage AC220V 2A Closing & Opening HCA type vacuum contactor consists of a threepole insulated monoblock containing three vacuum interrupters. The following are main components in relation to operations of the vacuum contactor. [ CLOSED condition ] [ Continuously energized ] [ Latched ] Latch device 6

HCA Type [ OPEN condition ] [ Continuously energized ] [ Latched ] Latch device Closing coil Main shaft Resistance Rear shaft Moving core Charging spring Latch device Opening spring Vacuum interrupter Insulation frame Pressing plate Auxiliary switch Shaft for auxiliary switch Closing When the closing coil( ) is energized, the moving core( ) moves to the closing coil and compresses the opening spring( ). At the same time the pressing plate( ), which is fixed on the main shaft( ), pushes the charging spring( ), so the movable stem of the vacuum interrupter( ) is moved up to make the CLOSED condition. Continuously energized type: When the moving core( ) moves, the auxiliary switch( ) leads the control power to resistance( ) and reduces the current of the closing coil( ). Latched type: When the contactor is closed, the latch device ( ) of the contactor fixs the moving core( ) mechanically and keeps the closed condition. Then the control power is removed. Opening Continuously energized type: When the closing coil( deenergized by the OFF signal, the opening spring( released to the OPEN condition. ) is ) is Latched type: When the opening coil is energized by the OFF siginal or the opening button is pushed, the latch device( ) is released and the opening spring( ) lets the moving core( ) move to the OPEN condition. During a power failure, the trip button or condensor trip device(ctd) of the latched type also enable the opening of the contactor. 7

VC Vacuum Contactor >> Technical Data Interlock Function Case Principle Release When the contactor is closed, it cannot be drawnin from test position to connection position it cannot be drawnout from connection position to test position The interlock pin of the contactor, which is inserted in the TEST/CONNECTION hole of cradle, mechanically prevents the contactor from moving. Open the contactor and draw in/out to required position. When the contactor is located in between each named position(disconnection TEST, TESTCONNECTION), it cannot be closed. When you draw in the contactor, it stops at the TEST position. The interlock pin of the contactor mechanically prevents the contactor from closing. Electrical interlock (option): The auxiliary switch cuts off the control power when the contactor is in the incorrect position. The interlock pin of the contactor is inserted in the TEST hole of the cradle and mechanically prevents the contactor from moving to the CONNECTION position. After drawing in/out the contactor to the required position, close it. E1/F1 Cradle: Hold up the interlock lever of the contactor, and push the contactor to the CONNECTION position. M1/T1 Cradle: Insert the drawin/out handle to the stopper, and drawinto the contactor to CONNECTION position by turning the handle in a clockwise direction. Interlock Mechanism Incorrect position Test & Connection position Closing coil Closing coil Moving core Moving core Interlock pin 1 Cradle TEST or CONNECTION hole Interlock pin 1 Cradle TEST or CONNECTION hole Interlock Release E1/F1 cradle M1 cradle Stopper Interlock lever Drawin/out handle 8

HCA Type Fuse without Fuse Holder Type The breaking current of without fuse type is limited, so a circuit breaker should be installed in the upper circuit of the line side. In the case of drawout types, the fuse holder connection part is replaced by a busbar. When it is required, the fuse holder can be installed under our instruction. with Fuse Holder Type The user can select and install fuses according to the specifications of the system. Fuses shall cut the shortcircuit current within the capacity of the contactor. A protection relay is recommend for overcurrent protection. A fuse Melting Detector can be offered as an option. The user can compose protection circuits for earth leakage and shortcircuit of singlephase by using a fuse melting detector. Fuse Selection Load Applicable fuse current 20A 30A 40A 50A 63A 80A 100A 125A 160A 200A 250A 315A 355A 2 160A 2 200A 2 250A 3φMotor (kw) 3φTransformer (kva) 3φCondenser (kvar) 3.3kV 6.6kV 3.3kV 6.6kV 3.3kV 6.6kV 50 100 30 60 80 160 50 100 100 200 75 150 90 160 125 250 100 200 100 200 160 315 125 250 125 250 200 400 150 300 160 330 250 500 200 400 200 400 315 630 250 500 275 550 400 800 300 650 315 650 500 1,000 375 750 400 830 630 1,250 500 1,000 500 1,000 750 1,500 600 1,200 600 1,200 900 1,800 700 1,400 500 1,000 800 1,600 600 1,200 650 1,300 1,000 2,000 750 1,500 750 1,500 1,250 2,500 1,000 2,000 This table is based on SIBA catalogue, and is for the 3phase motor with starting time max. 15 seconds and starting frequency 2 times per hour. SIBA recommends choosing the next highest voltage range in the condensor load. Please contact us for the further details of application data. Operating Condition Altitude : less than 1,000m A.S.L(above sea level) Multiply the impuise and the withstand voltage in accordance with the following correction factor (k) for high locations. Applied altitude Correction factor (k) 1,000m 1,500m 2,000m 2,500m 3,000m 1.0 1.05 1.1 1.15 1.2 Relative humidity : below 85% Please consider a heater in switchgears for extremely humid conditions. Ambient temperature : 5 +40 Multiply the rated current in accordance with the following correction factor (α) in high temperature conditions. Proper ventilation should be considered when installing more than three vacuum contactors into one switchgear. Ambient temperature Correction factor (α) 40 45 50 55 60 1.0 1.05 1.1 1.15 1.2 Special conditions Please contact us for information on special cases like seashore use, corrosive chemical environments, and so on. 9

VC Vacuum Contactor >> Accessories Standard Accessories Control lead cable (1.2m) Manual closing handle for latched type Additional Option Fuse melting detector Position switch Electrical Interlock Potential Transformer Condensor Trip Device When the latched type vacuum contactor is used in AC control voltage, the condensor trip device should be installed inside the 3.6/ contactor as an internal option. For contactor, it should be installed in switchgear. Order code Rated input voltage Ordinary charging voltage Ordinary current Frequency Applied standard HCAS0012 HCAS0013 AC110V AC220V DC145V DC290V DC2A 50/60Hz IEC 60694/KSC 4611 Terminal Connection 1,2: Input power(ac) / 5,6: Closing power(dc) / 5,7: Trip power Vacuum Checker The portable vacuum checker can be used to check the condition of vacuums. Order code Rated input voltage Rated output voltage Dimension Weight HAFSVC9 AC200/220V AC11/22kV W200 x L350 x H176mm 22kg 10

HCA Type >> Circuit Diagrams 3.6/ DC Control [ Continuously energized ] [ Latched ] 3.6/ AC Control [ Continuously energized ] [ Latched ] [ Continuously energized ] [ Latched ] Option [ 3.6/ ] [ ] Vza, Vzb: Control Switch R: Resistor CC: Closing Coil Aux. Switch: Auxiliary Switch X: Relay TC: Trip Coil CTD: Condensor Trip Device SCU: Control Unit S8, S9: Internal Position Switch 11

VC Vacuum Contactor >> Dimensions 3.6/ Fixed type without fuse holder Dimension Y 200A 400A 25 32 3.6/ Fixed type with single fuse holder Dimension A 200A 400A 25 32 3.6/ Fixed type with double fuse holder Dimension A 200A 400A 25 32 Dimensions may be revised without notice. 12

HCA Type 3.6/ Drawout type, E1 cradle without fuse holder 3.6/ Drawout type, E1 cradle with single fuse holder Dimensions may be revised without notice. 13

VC Vacuum Contactor >> Dimensions 3.6/ Drawout type, F1 cradle without fuse holder 3.6/ Drawout type, F1 cradle with single fuse holder 3.6/ Drawout type, F1 cradle with double fuse holder Dimensions may be revised without notice. 14

HCA Type 3.6/ Drawout type, M1 cradle without fuse holder 3.6/ Drawout type, M1 cradle with single fuse holder 3.6/ Drawout type, M1 cradle with double fuse holder Dimensions may be revised without notice. 15

VC Vacuum Contactor >> Dimensions 3.6/ Drawout type, T1 cradle with double fuse holder Fixed type without fuse holder [ front ] [ side ] [ top ] Fixed type with single fuse holder [ front ] [ side ] [ top ] Dimensions may be revised without notice. 16

HCA Type Drawout type, E1/F1 cradle without fuse holder / with single fuse holder Drawout type, M1 cradle without fuse holder / with single fuse holder Dimensions may be revised without notice. 17

VC Vacuum Contactor >> Order Information HCA 6 4 C D 4 Model Name Rated Voltage Rated Current Operating Method Structure Contactor Fuse Holder Control Voltage HCA HCA 3 6 2 200A 4 400A C Continuously Energized F A Fixed type up to Fixed type up to Single 1 DC110V 2 DC220V 8 L Latched J Fixed type up to Double 3 AC110V B Drawout type up to 4 AC220V D Drawout type up to Single H Drawout type up to Double Standard Order Continuously energized Specification Latched Specification Category HCA32CF 4000000 HCA62CF 4000000 HCA82CF 4000000 200A Fixed type without fuse holder, No cradle, No fuse holder HCA32LF 4000000 AF HCA62LF 4000000 AF HCA82LF 4000000 BF 1) 200A Fixed type without fuse holder, No cradle, No fuse holder, AC220V CTD HCA32CD 4F16000 HCA62CD 4F16000 HCA82CD 4F1600A 200A Drawout type with single fuse holder, F1 cradle, No fuse HCA32LD 4F16000 AF HCA62LD 4F16000 AF HCA82LD 4F16000 BF 1) 200A Drawout type with single fuse holder, F1 cradle, No fuse, AC220V CTD HCA32CD 4M16000 HCA62CD 4M16000 HCA82CD 4M1600A HCA34CF 4000000 HCA64CF 4000000 HCA84CF 4000000 200A 400A Drawout type with single fuse holder, M1 cradle, No fuse Fixed type without fuse holder, No cradle, No fuse holder HCA32LD 4M16000 AF HCA62LD 4M16000 AF HCA82LD 4M16000 BF 1) HCA34LF 4000000 AF HCA64LF 4000000 AF HCA84LF 4000000 BF 1) 200A 400A Drawout type with single fuse holder, M1 cradle, No fuse, AC220V CTD Fixed type without fuse holder, No cradle, No fuse holder, AC220V CTD VC V2 HCA34CD 4F16000 HCA64CD 4F16000 HCA84CD 4F1600A 400A Drawout type with single fuse holder, F1 cradle, No fuse HCA34LD 4F16000 AF HCA64LD 4F16000 AF HCA84LD 4F16000 BF 1) 400A Drawout type with single fuse holder, F1 cradle, No fuse, AC220V CTD HCA34CD 4M16000 HCA64CD 4M16000 HCA84CD 4M1600A 400A Drawout type with single fuse holder, M1 cradle, No fuse HCA34LD 4M16000 AF HCA64LD 4M16000 AF HCA84LD 4M16000 BF 1) 400A Drawout type with single fuse holder, M1 cradle, No fuse, AC220V CTD 1) CTD of contactor will be delivered as separate part. 18

HCA Type M1 6000 AMAP Cradle Fuse Application Fuse Holder Fuse Specification Additional Option Application Mounting 00 E1 F1 M1 T1 N/A (for Fixed type) without Shutter with Insulation Shutter with Metal Shutter and Bushing with Metal Shutter, Bushing and Earthing Switch 0000 6000 Single up to 250A, 192mm 600A 600B 600C Single Double Single Fuse is not included. 3.6/ 315/355A,, 292mm 3.6/, 192mm 442mm AE BE AF BF AL BL AM BM AP BP T1 T3 T4 T6 CTD, AC110V CTD, AC220V Electrical Interlock Fuse Melting Detector Position Switch Potential Transformer, x 1EA Potential Transformer, x 1EA Potential Transformer, x 2EA Potential Transformer, x 2EA 3.6/ 3.6/ Latched type, AC control Inside of 3.6/ Drawout type contactor 3.6/ for Fuse 3.6/ Drawout type Cradle 3.6/ All Inside of contactor Spare Parts Specification Category Specification Category HCAS0001 Counter (5 digit) HCAS6032 Fuse /31.5A/63kA, 192mm, 1EA (SIBA) HCAS0002 Manual closing handle (for latched type) HCAS6040 Fuse /40A/63kA, 192mm, 1EA (SIBA) HCAS0003 Latch device (DC110V) HCAS6050 Fuse /50A/63kA, 192mm, 1EA (SIBA) HCAS0004 Latch device (DC220V) HCAS6063 Fuse /63A/63kA, 192mm, 1EA (SIBA) HCAS0005 Fuse melting detector (3.6/) HCAS6080 Fuse /80A/63kA, 192mm, 1EA (SIBA) HCAS0006 Position indicator (3.6/) HCAS6100 Fuse /100A/63kA, 192mm, 1EA (SIBA) HCAS0007 Closing coil (DC110/220V, 3.6/, 1EA) 1) HCAS6125 Fuse /125A/63 ka, 192mm, 1EA (SIBA) HCAS0008 Closing coil (DC110/220V,, 1EA) 1) HCAS6160 Fuse /160A/63kA, 192mm, 1EA (SIBA) HCAS0009 Potential transformer (/200VA) HCAS6200 Fuse /200A/50kA, 192mm, 1EA (SIBA) HCAS0011 Potential transformer (/200VA) HCAS6250 Fuse /250A/50kA, 192mm, 1EA (SIBA) HCAS0012 Condenser trip device (AC110V) HCAS6315 Fuse /315A/50kA, 292mm, 1EA (SIBA) HCAS0013 Condenser trip device (AC220V) HCAS6355 Fuse /355A/50kA, 292mm, 1EA (SIBA) HCAS0015 HCAS0016 Control lead cable (length 1.5m, 3.6/) Control lead cable (length 2.0m, 3.6/) VC V8 HCAS7006 HCAS7010 Fuse /6.3A/63kA, 292mm, 1EA (SIBA) Fuse /10A/63kA, 292mm, 1EA (SIBA) VC V8 HCAS0019 Fuse holders for single type (3.6/, 1EA) 1) HCAS7016 Fuse /16A/63kA, 292mm, 1EA (SIBA) HCAS0020 Fuse holders for double type (3.6/,1EA) 1) HCAS7020 Fuse /20A/63kA, 292mm, 1EA (SIBA) HCAS0018 Fuse holders for single type (, 1EA) 1) HCAS7025 Fuse /25A/63kA, 292mm, 1EA (SIBA) HCAS0021 Isolating contact (3.6/, 200A) HCAS7032 Fuse /32A/63kA, 292mm, 1EA (SIBA) HCAS0022 Isolating contact (3.6/, 400A) HCAS7040 Fuse /40A/63kA, 292mm, 1EA (SIBA) HCAS0023 Isolating contact (, 400A) HCAS7050 Fuse /50A/63kA, 292mm, 1EA (SIBA) HVC00704 Vacuum interrupter (, 400A) HCAS7063 Fuse /63A/63kA, 292mm, 1EA (SIBA) HVC01204 Vacuum interrupter (, 400A) HCAS7080 Fuse /80A/63kA, 292mm, 1EA (SIBA) HCAS6006 Fuse /6.3A/63kA, 192mm, 1EA (SIBA) HCAS7100 Fuse /100A/63kA, 292mm, 1EA (SIBA) HCAS6010 Fuse /10A/63kA, 192mm, 1EA (SIBA) HCAS7125 Fuse /125A/63kA, 292mm, 1EA (SIBA) HCAS6020 Fuse /20A/63kA, 192mm, 1EA (SIBA) HCAS7160 Fuse /160A/63kA, 292mm, 1EA (SIBA) HCAS6025 Fuse /25A/63kA, 192mm, 1EA (SIBA) HCAS7200 Fuse /200A/50kA, 292mm, 1EA (SIBA) 442mm fuse is applicable to vacuum contactor, but not supplied by HHI. 1) 2EA is required for 1set of vacuum contactor. 2) 6EA is required for 1set of vacuum contactor. 19