H 29 H 29 H 29 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

Similar documents
ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

W 12 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. DRIESCHER - Air-Insulated Medium-Voltage Switchgears

STROM SICHER SCHALTEN

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

15/60 15/60. FLa ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. Operating and maintenance instructions

Rated voltage 12 kv to 38.5 kv Rated current 630 A to 2500 A

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & S HNE GMBH D MOOSBURG TEL. ( ) FAX ( )

18D according to ATEX

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & S HNE GMBH :85366 MOOSBURG TEL. ( ) FAX ( )

Clamping systems. LinClamp/HLGClamp. LinClamp SA. LinClamp SK. LinClamp A

STROM SICHER SCHALTEN

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

Modular medium-voltage switchgear. NorMax

Outdoor disconnectors FTr (previously 6400 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current 400 and 630 A

SF6 LOAD BREAK SWITCH. Remote Controlled OCR TELE_1_2013.EN

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

I B D Q I B D Q O I B D Q O

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

CPG.0 Single busbar gas-insulated cubicles

Medium Voltage Metal-Enclosed Switches

MEDIUM VOLTAGE DISCONNECTOR SWITCHES for indoor installation

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

HD4. Gas insulated MV circuit-breakers kv A ka

GRUNDFOS DATA BOOKLET. CHV booster. Hydro Pack, Hydro Dome 50 Hz

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Overhead line switchgear

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

Medium voltage Low voltage Outdoor Railway Accessories ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Medium Voltage Metal-Enclosed Switches

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

Cartridge pressure switch Type CB

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

JFC Series Rack & Pinion Actuators SGS MD 2006/42/EC

DYNAMIC BRAKING (DB) OPTION

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

ABB AG - Calor Emag Medium Voltage Products OEM Products Medium Voltage Products. ABB OEM Products 1

cpg.0 y cpg.1 Reliable innovation. Personal solutions. Families of single and double busbar GIS-type cubicles

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

CGMCOSMOS Fully gas-insulated modular and compact (RMU) system Up to 24 kv

Air-insulated medium voltage switchgear metal-enclosed type-tested factory-assembled withdrawable-unit design 12 kv / 24 kv

UniSec licensed by ABB, produced by Metix WHERE ENERGY LIVES COMPLETE SOLUTIONS

Pretest Module 29 High Voltage Unit 1

Summary Catalogue. In 1998, the daughter company DRIBO Stará Turá s.r.o. (Ltd.) was founded in the Slovak Republic.

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

Special conveyor chains

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

B kv Gas-insulated Substations

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

SF6 Gas-Insulated Metal Enclosed Switchgear

SENTRON Switching and Protection Devices Switch Disconnectors

Content. Uniswitch. 1. Design philosophy Applications Switchgear construction Cubicle types... 9

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition

vertical fuse switch disconnectors

GRUNDFOS DATA BOOKLET. Hydro Grundfos Hydro 1000 booster sets with 1-4 CR pumps 50 Hz

PIX-H Metal-clad switchgear up to 17.5kV

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

Gas Insulated Switchgear

GRUNDFOS DATA BOOKLET. Hydro 1000 G - X. Grundfos Hydro 1000 G - X booster sets with 1-4 CR pumps 50 Hz

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

Magnefix kv Insulation enclosed switchgear. Magnefix. Compact switchgear for medium voltage distribution

Medium Voltage Outdoor Apparatus Portfolio 2009

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

Medium voltage products HD4/R MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM

Medium Voltage Distribution PI 100. up to 24 kv Air-insulated circuit-breaker switchgear for primary distribution. System configuration

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

8DJ. Maintenance-free for lifetime

B kv T&D GAS INSULATED SWITCHGEAR

VD4/R. Medium Voltage vacuum circuit-breakers for secondary distribution

RAPIER DSB Disconnectors

cpg.0 & cpg.1 Reliable innovation. Personal solutions. Single and double busbar panel type GIS system

OHB Outdoor sulphur Hexafluoride circuit-breaker

Series 32D Electronic Pressure Switch for Hydraulic and High Pressure Applications. Series 18D Hydraulic. Pressure Switch

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Gas Insulated Metal-clad Switchgear, HMGS!

TECHNICAL SPECIFICATIONS

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C up to 24 kv, SF 6 -Insulated. Medium-Voltage Switchgear Catalog HA 35.

COMPACT AND EXTENSIBLE RING MAIN UNIT. insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

Transcription:

H 29 DRIESCHER Indoor SwitchDisconnector and switchfuse combination H29 24 and 36 current 29 H 29 H 29 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D85366 Moosburg Phone: +49 861 6810 Fax: +49 861 68113 www.driescher.com infoservice@driescher.de

DRIESCHER Indoor SwitchDisconnector and switchfuse combination H 29 acc. to EN 6221103 and EN 6221105 2 Tyes of SwitchDisconnectors, Oerating conditions 3 Main advantages, Energie storage mechanism, rc extiniction 4 dditional equiment, Technical data 5 SwitchDisconnector H 29,, Tye E 6 Switchfuse combination H 29,, Tye SE SwitchDisconnector H 29,, Tye E, singleole 8 Range of roducts includes Tyes of SwitchDisconnectors and switchfuse combinations For many years DRIESCHER indoor switchdisconnectors H29 have guaranteed an excellent osition in switchgear engineering. These switchdisconnectors master the daily loads exerted under normal switching duty for interruting ring feeders, disconnecting network transformers and such with very high oerating frequencies and a minimum amount of maintance. These loadbreak switches are distiguished by simle design, absolute reliability in oeration and easy actuation. * see age 3, Energy storage mechanism Tye H 29 E with trifree mechanism* Tye H 29 E, singleole with trifree mechanism* Tye H 29 SE with trifree mechanism* as well as with fuse holders mounted bellow for HV HBC fuses with in release, for allole disconnection of the switch when a fuse oerates. The devices are fitted with an energy storage mechanism for quickmake and quickbreak oeration. In switchfuse combination (Tye SE) only HV HBC fuses with in release and a triing imact force of min. 80 N are to be used (DRIESCHER / SIB; refer also to 91). Oerating conditions The switches are designed for normal oerating conditions according to EN 62211 class Minus 5 Indoor. The eak value of the ambient temerature is 40 O C; the average value over 24 hours is 35 O C at best. The values of the insulating ower are related to sealevel. Reduction in insulating caacity at hights u to 1000 m are negligible due to the decreasing insulating caacity of the air. t hights over 1000 m above sealevel the values for rated withstand alternating and rated imulse withstand must be adjusted (e. g. at a hight of 2000 m above sealevel, the insualting ower of the air gas is reduced by a factor of 0.89). To each switchgear an instruction for transortation, mounting and utting into service is inclosed. This instruction which we certainly would send you in advance, has to be absolutely obeyed. 2

DRIESCHER Indoor SwitchDisconnector H 29 Substantial advantages High oerating safety Isolating distance visible after load disconnection High oerating frequency with minimum amount of maintenance Efficient and reliable arc extinction Convenient dimensions Easy oeration Energy storage mechanism One of the robust, lowmaintenance energy storage mechanisms of tye H 29 E is mounted on the base frame on which the three switch oles are installed. Hundreds of thousands of these devices have already been used successfully in the Switch Disconnector H 22. The E energy storage mechanism oerates with two torsion srings for quickmake and quickbreak oeration with trifree release. Both torsion srings are tensioned when the switch is closed. While the ON switch sring relaxes after tensioning and releases the energy for switching ON, the OFF switch sring remains tensioned and can be released by the triing device, HV HBC fuse with in triggering or manually for switching OFF. With nonmanual release the oerating shaft remains in ON osition and must be moved to the neutral osition manually for reclosing. The actuation for wallmounting devices can take lace via a linkage system oerated by a lever or using any of the manual actuators given in or motorized actuator given in brochure 4, according to requirements and situation. rc extinction When closing the switch the switch blade (5) with the arcing ti (6) is withdrawn from the contact jaw (2). The arc which occurs is extinguished in the arcing chamber (4). This chamber is enclosed, has four sections and comrises a ressure and an exansion chamber. In the ressure chamber two airs of extinguishing lates (3) are forced into the ath of the arc by lateral sring ressure. t low currents the arc is extinguished by deionising action based on the cooling effect of the walls. rc extinction is achieved in the higher current ranges by the arc extinguishing gases roduced in the ressure chamber flowing out into the exansion chamber. Based on the rational combination of several arc quenching rinciles the entire current range of the loadbreak switch is always effectively covered. 1 Uer connecting contact Lower connecting contact The arcing chambers require no maintenance. ON OFF 1 1 2 2 3 4 5 3 4 6 6 5 3

DRIESCHER Indoor SwitchDisconnector H 29 dditional equiment ll tyes are available with earthing switches mounted above and below. In tyes H 29 E the earthing switch is mounted above or below, on the switch frame (retrofitting is ossible). Tye H 29 SE are available with earthing switches integrated in the switch frame. ositive locking between switchdisconnector and earthing switch is ossible. The earthing switches generally have shortcircuit making caacity and are therefore makeroof. uxiliary switches, Release coils or shunt releases (110 V, 230 V C, or 24 V, 60 V, 110 V, 220 V DC) can be mounted on all switches including earthing switches. ll steel arts are galvanised and chromatised. Design switchfuse combination These switchfuse combination acc. to EN 6221105 consists of a function unit of switchdisconnector acc. to EN 6221103 and currentlimiting fuses acc. to EN 602821. The use of the switchfuse combination is on transformer rotection, esecially for lower and mean ower. The HV HVC fuse in combination with a switchdisconnector rovides a simle solution which is very economical to rocure and run. This rovides a clearcut advantage over a circuit breaker with the associated current transformers and overcurrent time rotection. Besides this, the HV HVC fuse has a current limiting effect when shortcircuits occur and reliably interruts the fault current of the first half cycle. These roerties are advantageous for the dimensional design of the network. The actuation of the loadbreak switch H 22 can be carried out with a linkage system oerated by a lever or with a motoroerated mechanism. Indoor actuators and accessories see brochure 4. Drive rods and fuse tongs see brochure 3 (system accessories). Technical data acc. to EN 6221103 frequency current eak withstand current shorttime current shortcircuit making current mainly active breaking current closedloo breaking current transformer offload breaking current cablecharging breaking current earth fault breaking current cablecharging breaking current under earth fault conditions Electrical class Mechanical class Ur fr Ir I Ik Ima I1 I2a I3 I4a I6a I6b Hz k k k 24 50 50 1) 20 1) 36 22 163 35 E1 M1 36 50 50 1) 20 1) 20 5 24 134 20 E1 M1 1) These values also aly to earthing switches or earthing devices Insulation level acc. to EN 62211 lightning imulse withstand 1,2/50 µs Conductor Earth Conductor Conductor Insulating distance Ur Uw 24 125 125 145 36 10 10 195 ower frequency withstand Conductor Earth Conductor Conductor Insulating distance Ud 50 50 60 0 0 80 4

DRIESCHER Indoor SwitchDisconnector H 29 SwitchDisconnector H 29 E, t 36 Head of screw at the front: 1) Hexagon screw with nut, washer and sring washer Phase searating lates (5mm thick) only for 36 Tye H 29 E with earthing switch mounted below Earthing switch with or without without earthing switch 24 36 current PartNo.: 29 52000 29 62200 c 1 30 30 c 2 50 50 d 90 90 f 48 502 g 63 80 h 445 550 H 340 445 H 1 354 H 2 439 i 950 k 1060 x/y 565 435 42,5 4,0 DrawingNo.: LG303842 LG303842 earthing switch mounted below current PartNo. with PartNo. without b 1 L x 1 /y 1 DrawingNo.: 24 36 29 52014 29 62214 29 52011 29 62211 315 326 436 565 435 55,5 90,0 LG303842 LG303842 5

DRIESCHER Indoor SwitchDisconnector H 29 Switchfuse combination H 29 SE t 36 Head of screw at the front: 1) Hexagon screw with nut, washer and sring washer Phase searating lates (5mm thick) only for 36 Tye H 29 SE with earthing switch mounted below und fuse holders for HV HBC fuses u to 125 rated current without earthing switch 24 36 current 3) /125 /125 a 1 b b 1 c 1 c 2 c 3 d f g h H 1 H 2 1105 30 50 90 1058 63 445 335 655 1200 310 30 50 50 90 11 80 550 430 439 i 950 k 135 24 36 current 3) /125 /125 s 45 50 u 615 10 x/y 565 435 PartNo.: 29 54000 29 64200 2) 0,5 113,5 DrawingNo.: LG326622 LG326622 earthing switch mounted below 24 36 current 3) /125 /125 l 530 x1/y1 650 PartNo. with 29 54014 29 64014 PartNo. without 29 54000 29 64000 2) 130,5 132,5 DrawingNo.: LG326622 LG326622 2) s without HV HBC fuses 3) current of the fuse holder 125 6

DRIESCHER Indoor SwitchDisconnector H 29 SwitchDisconnector H 29 E singleole, 1) Hexagon screw with nut, washer and sring washer Tye H 29 E singleole, with earthing switch mounted below (Motor drive on the left or right side ossible) without earthing switch current PartNo.: DrawingNo.: 24 29 52904 29 LG449819 earthing switch mounted below current PartNo. with DrawingNo.: 24 29 52903 34 LG449819

Our range of roducts includes: Medium systems Singlebusbar and dulicatebusbar switchgear Fixed mounting, withdrawable design and trucktye units Comact switchgear assemblies Customersecific models Industrial switchgear Power factor correction and filter equiment Medium switches Indoor loadbreak switches, disconnectors, and earthing switches (single and trile ole) Indoor circuit breakers (low oil content and vacuum) Outdoor loadbreak switches, disconnectors, and earthing switches (single and trile ole) Railway switches for ower suly and catenary High highbreakingcaacity fuses Customersecific switches Low systems Oenframework design Enclosed switchgear (u to 6.300 ) Motor Control Center (MCC) Cable and fixedstation distribution cabinets Low switches Switch disconnectors Switching stris and fuse blocks Comact substation Concrete construction Container construction Driving gear Handoerated and motoroerated mechanisms for indoor and outdoor alication ccessories For medium and low For station equiment Insulators (0,5 38,5 ) Plastic and glass fibrereinforced lastic screening Service Maintenance and Service of all switches and switchgear Training courses and seminars Thermograhy; Liveline working Dimensions, weights, diagrams and descritions in the list are nonbinding. Subject to change without notice. STROM SICHER SCHLTEN ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH 85366 Moosburg Tel.: +49 861 6810 Fax: +49 861 68113 www.driescher.de infoservice@driescher.de Order No.: 3810291 018