HV-Fuse-links SSK type SSK 10/02

Similar documents
High voltage high-breaking capacity VV fuse-links

Thermal system protection of switchgear through high voltage fuse links with integrated temperature limiter under consideration of IEC 420:1990

FUSES. Safety through quality

HIGH VOLTAGE FUSE-LINKS HIGH VOLTAGE FUSE-LINKS WITH THERMAL STRIKER HIGH VOLTAGE FUSES POWER NEEDS CONTROL

High-voltage high-breaking capacity VV fuse-links

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

Limitor -G General Purpose Fuses

Use of switch-fuse combinations at the medium-voltage level for the protection of distribution transformers siemens.com/tip-cs

Medium voltage fuses - European Fuses

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

Fuse-Links according to VDE 0670 T 402. Hi gh-voltage

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

High-Voltage Fuse Links according to IEC

LOW VOLTAGE FUSES EUROPEAN NH KNIFE-BLADE FUSE SYSTEM

Medium Voltage current limiting Fuse links

High-voltage high-breaking capacity VV fuse-links

Current Limiting Fuses, CEF Motor Circuits Fuses, CMF. Catalogue 1YMB en. Industrial IT. enabled

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear

Medium Voltage current limiting Fuse links

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

Our experience is the protection for your installation

Technical information No. 01. IT systems. The basis for reliable power supply

Standardized fuse characteristics

LG HRC Power Fuses ISO 9001 ISO 14001

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Contactor-Fuse Combination 3TL62 / 63 / 66

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Parallel connection of fuses

Section ( VI ) TECHNICAL SPECIFICATIONS AND SCHEDULES

High voltage current limiting Fuse links type CEF

Medium voltage products. Fuses

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

MEDIUM VOLTAGE DIN Fuse-Links

Selective main circuit breakers S 750 series Technical Data

RAPIDPLUS. high speed fuse links for semiconductors

2013 JEAN MÜLLER Products

3.6kV 36kV High Voltage DIN Distribution Fuses

Special Purpose Fuses

Ultra-Rapid Fuse Links for the Protection of Semiconductor Rectifiers

MEDIUM VOLTAGE DIN Fuse-Links

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Medium voltage products. Fuses

RAPIDPLUS. high speed fuse links for semiconductors

EUROPEAN HIGH VOLTAGE FUSES

B4 Load Break Switches

MEDIUM VOLTAGE FUSES FOR CAPACITORS NORTH AMERICAN STYLE

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear (In Air)

Bussmann 7.2 kv Medium voltage fuse links

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Technical information

Low voltage NH knife-blade fuse-links

Bussmann series NH catalogue. Leadership in circuit protection

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

3.2. Current Limiting Fuses. Contents

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

Ultra Rapid Fuses. For Semiconductor Protection

34-SDMS-02 SPECIFICATIONS FOR

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Circuit Protection Solutions. Medium Voltage DIN Fuses

Paramount HRC Cartridge

Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil)

FUSE: SAFE & RELIABLE

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

IEC Standard Back-Up Fuse-Links

2006 IEEE PES General Meeting June 2006, Montreal, Canada Paper 06GM0613. Fault Current Limiters - Report on the Activities of Cigre WG A3.

Technical background information provided by SIBA: Know-how on Electrical Fuses

Applications. Fuse range selection. Motors Power transformers. Voltage (kv)

How to Use Coordinaide to Protect Transformers Against Secondary-Side Arcing Faults.

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N

Semiconductor Fuses European Fuses

onlinecomponents.com

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

Issue Title Remarks. Instrument transformers See IEC 61869

W DATA SHEET: COMBINED RCD/MCB DEVICES BO, 3-POLE

UL248 North American Low Voltage Fuses

TECHNICAL DESCRIPTION

Medium Voltage Fuse Links Full Line Catalogue

HIGH VOLTAGE CURRENT LIMITING FUSE-LINKS CAPABLE OF BREAKING ALL CURRENTS THAT CAUSE MELTING OF THE FUSE-ELEMENT. D. van der Scheer H.F.J.

NEXT STEP B) SAFETY :

Miniature circuit breaker Application guide

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

NH LOW VOLTAGE a FUSE SYSTEM

EnergieBlock TEB. Industrial unit substation air-insulated 12 kv / 24 kv AN-/AF-Operation roof-ventilators arc fault tested with HRC fuses

Air-insulated switchgear UniGear type ZS1

General information on current-limiting fuse-links. The main characteristics of the CNC fuse-links. Construction. Operating.

3 - Protection components Motor circuit-breakers

Transcription:

HV-Fuse-links SSK type SSK 10/0 Reg.-Nr. 0/QM/07.00 QM-System-Audit DIN EN ISO 9001 UMWELTMANAGEMENTSYSTEM DQS - zertifiziert nach DIN EN ISO 1001 Reg.-Nr. 1-0 SICHERUNGEN/FUSES SIBA Sicherungen-Bau GmbH Borker Straße D-5 Lünen

SICHERUNGEN/FUSES HV-Fuse-links SSK type High-voltage fuse-links for switch-fuse combination The SIBA high-voltage fuse-link type SSK extends the range of usage for switch-fuse combinations up to larger transformer sizes. In connection with the temperature sensitive striker pin, which avoids switchgear damage caused by higher temperatures, this high-voltage fuse type allows proper and cost-effective fusing of distribution transformers by means of switch-fuse combinations. When fuse rated currents are selected for protection of distribution transformers, uncertainties may arise when the engineer considers the applicable standards. Whilst the fuse manufacturers recommendations usually refer to DIN VDE 070-0 (VDE 070 part 0): 19-05 [1], the manufacturers of fused load break switches recommend fuse rated currents which comply with their testing according to DIN EN 00 (VDE 070 part 0): 199-09 [], respectively IEC 00 [], and many times these currents will be considerably lower. The application of both standards therefore leads to a different fuse-rated current so that one could come to the conclusion that fuse protection on the basis of both standards is practically impossible. A solution is provided here by using the newly developed SIBA high-voltage fuse links [5], which consider the specialities and practical advantages of both standards. Fuse protection of distribution transformers Because high-voltage fuses are related to transformers (and most of the time to the switch), their protective range extends up to the fuse on the low voltage side of the transformer. This means that overcurrents rise because of faults on the low voltage busbar, due to winding or earth faults inside the transformers which are reliably cut off by the high-voltage fuses fitted on the highvoltage side of the transformer before the dynamic effects can affect the medium voltage network. Operating currents and times of the high-voltage fuse are coordinated with the transformer, the low-voltage fuse (NH-fuse-link service class gtr or gg) and the medium voltage protective device respectively. Picture 1 a) to 1 c) show typical protection variants of transformers. The dependence of all components involved, as there are transformer high-voltage fuse-links, secondary side protection devices and upstream protection on the high-voltage side, are shown in the diagram (picture ). The high voltage fuse has to comply with the following criteria: The high voltage fuse must withstand the transformer inrush current (picture, point A), which can have a value of between to 0 times the transformer rated current (for 0,1 second) depending on the transformer size. The maximum short circuit current, defined from the relative voltage uk of the transformer, must be interrupted within the permitted short circuit time according to DIN 575-5 (VDE 05 part 5): 19-05 []. The high voltage fuse must be able to hold the transformer service current (transformer rated current) continuously. a) b) c) NH-gG HH NH-gTr NH-gG Heinz-Ulrich Haas Ralf Löffler When the transformer is overloaded by 150% (permitted overload), the temperature that the switchgear is designed for must not be exceeded. In the time-current characteristic, the operating current and times of the high-voltage fuse must discriminate with the low-voltage fuse. Possible intersections of both characteristic currents can only be accepted above the maximum short-circuit current (picture, point B) On the transformer high-voltage side, there must be discrimination with the upstream protection of the high-voltage network. Avoidance of undesirable high temperatures High-voltage fuse-links are fitted with striker pins, which are also used as an indicator. Where high-voltage fuse-links are fitted in a switch-fuse combination, this striker pin will open the switch via its tripping mechanism and switch off all three phases. In order to avoid undesirable high temperatures in switchgear, SIBA highvoltage fuse-links are fitted with integrated temperature limiting striker pins. High temperatures can for example arise when the fuses are operated in the so-called forbidden range, meaning below the minimum breaking current. Higher temperatures can also arise when lightning influences the fuse-links. HH NH-gG NH-gG Picture 1: Distribution transformer with typical protection variants (a - c) HH

SICHERUNGEN/FUSES HV-Fuse-links SSK type Transformer rated capacity in kva Rated voltage kv / 7, 10 / 1 0 / 0 / 100 15 0 50 15 00 500 0 00 1000 u z = % *) u z = 5 % *) Highest admissible short-circuit duration s*) High-voltage fuse-links rated voltage in A 0 5 1,5 0 50 0 100 15 10 10 and 5 and 1,5 and 0 and 50 and and 0 and 100 and 15 and 10 and 00 1 1 0 5 1,5 0 50 0 100 15 and 5 and 1,5 and 0 and 50 and and 0 and 100 and 15 and 10 0 1 1 1 5 5 1,5 0 up to 5 and 1,5 and 0 and 50 and 0, 0 1 1 0 5 5 1,5 0 0 up to 5 and 5 and 1,5 and 0 and 50 and 50 *) Rated short circuit voltage u z and highest admissible short circuit duration according to DIN 575-5 (VDE 05 Teil 5):19-05 [] Fuse recommendation to DIN VDE 070-0 (VDE 070 Teil 0):19-05 [1] values in the millisecond range (switch opening time at striker pin operation) according to DIN EN 00 (VDE 070 part 0): 199-09. Considering both standards, this can also result in high voltage fuse rated currents of different values. The responsible network engineer has two alternatives to solve this problem: Either he will make his own calculations and comparison of time-current characteristics in order to comply with the criteria for fuse protection of transformer circuits, or he can use the latest development in high-voltage fuse-links which comply with both standards. High-voltage fuse-links SSK type SIBA has made a new development in order to enable DIN high-voltage fuses [] to comply with the requirements mentioned above. The result of this development is the high-voltage fuselink SSK type. The new fuse-links look identical to the existing design, only the designation "SSK-type" and "VDE 070 part 0" indicate this specific application. The melting elements show the wellknown profile. However, the dimensions of the notches and the correlation to the total cross section were optimised and modified. The priority in development was to achieve a reduction in the melting times in the range below 100 milliseconds, without negatively influencing other fuse rated values. The switchgear manufacturer s requirements for low temperature rise are complied with; the power loss at rated value of the transformer is only 70-75Watts. The well known low value of the minimum breaking current being.5 times fuse rated current was maintained from our standard high-voltage fuse-links. In the range below 100 milliseconds, the time-current characteristic of the new SSK high-voltage fuse-link is positioned on the lower limit-line of DIN VDE 070-0 (VDE 070 part 0): 19-05 [1]. By this feature, the specific requirements of the switchgear manufacturers were fully realized. Discrimination with the low-voltage NH fuse-links of operating class gtr or gg is ensured, where the very steep time-current characteristics of the NH-fuse-links are advantageous. DIN EN 00 (VDE 070 part 0): 199-09 [] requirements are also considered by the fast characteristic in the range below 100 milliseconds. This results in low take-over currents of the fuse-link which very positively comply with the standard requirements: rated take-over current of the switch take-over current of the fuse-link maximum secondary short-circuit current > take-over current of the fuse-link High-voltage fuse-links SSK type are new products as an extension of the existing product range. The specific application is for switchgear with relatively low values of switch opening times and take-over currents, which are used to protect transformers 0 kva. For smaller transformers, the well known standard SIBA fuse-links can be used because of the better relationship between fuse take-over current and rated switch take-over current. Literature [1] DIN VDE 070-0 (VDE 070 Teil 0):19-05 Wechselstromschaltgeräte für Spannungen über 1 kv Auswahl von strombegrenzenden Sicherungseinsätzen für Transformatorstromkreise. [] IEC 077:19-01 Application guide for the selection of fuse-links of high-voltage fuses for transformer circuit application. [] DIN EN 00 (VDE 070 Teil 0): 199-09 Hochspannungs-Lastschalter- Sicherungs-Kombinationen. [] IEC 00:1990-10 High-voltage alternating current switch-fuse combinations. [5] www.siba.de [] DIN 575-5 (VDE 05 Teil 5):19-05 Transformatoren und Drosselspulen Teil 5: Kurzschlußfestigkeit. [7] Haas, H.-U.: Thermal system protection of switchgear through high voltage fuselinks with integrated temperature limiter under consideration of IEC 0:1990. S.-70. Proceedings of the 5th International Conference on Electrical Fuses and their Application (ICEFA), 5.-7.9.1995, TU Ilmenau. [] DIN EN 0-1:199-0 Hochspannungssicherungen Teil 1: Strombegrenzende Sicherungen. Dr.-Ing. Ralf Löffler (5) is Technical Manager at SIBA Sicherungen-Bau GmbH in Lünen. E-Mail: ralf.loeffler@siba.de Dipl.-Ing. Heinz-Ulrich Haas () is Head of Research and Development at SIBA Sicherungen-Bau GmbH in Lünen. E-Mail: ulrich.haas@siba.de

HH - Sicherungseinsätze für Lastschalter - Sicherungs - Kombinationen HV - Fuse links for switch - fuse combinations Typ type DIN - SSK Charakteristik charakteristic Teilbereich Back up Bemessungsausschaltvermögen rated breaking capacity AC ka @ U N = kv AC 0 ka @ U N = kv Standard IEC 0-1 standard VDE 070 Teil IEC 00 Bemessungs- Kleinster spannung Artikel Nr. Bemessungsstrom Ausschaltstrom Schmelzintegral Ausschaltintegral Leistungsabgabe Minimum rated voltage Part No. rated current breaking current pre-arc I²t s total I²t a power loss [kv] [A] [A] [A²s] [A²s] [W] 0 01 0 0 1.00 10.000 7 / 1 0 01 100 0.00 1.000 9 0 00 15 50 9.000.000 15 0 01 10 9.00 7.000 117 10 / 0 01 0 0 1.00 10.000 1 0 0 100 0.00 1.000 1 0 0 15 50 0.00.000 77 0 / 0 0 10 9.00 7.000 19 0 0 0 0 1.00 17.00 15 NB E' disponibile anche la portata 10A, le cui curve caratteristiche sono riportate in fondo al documento. Sicherungen-Bau GmbH Borker Straße D 5 Lünen Telefon 00 / 7001-0 Postfach 190 D 509 Lünen Telefax 00 / 7001-10

HH - Sicherungseinsätze für Lastschalter - Sicherungs - Kombinationen HV - Fuse links for switch - fuse combinations Abmessungen gem. DIN 5 dimensions acc. DIN 5 U N Art. Nr. I N 'e' D [kv] art. No. [A] [mm] [mm] 001.0 0 /1 001.100 100 9 7 000.15 15 5 10/ 0/ 001. 001.0 0 00.100 100 00.15 15 00. 00.0 0 57 7 5 5 HH 0 01 0.0.00 / Sicherungen-Bau GmbH Borker Straße D 5 Lünen Telefon 00 / 7001-0 Postfach 190 D 509 Lünen Telefax 00 / 7001-10

HH0 01 0.05.00 / 10 10 s 10 Effektiv-Wert des unbeeinflußten Stromes 10 - RMSprospective current 5 5 10 5 10 5 10 A 5 10 5

Strombegrenzungs-Diagramm Cut-off characteristics HH-Sicherungseinsätze DIN VDE 070Teil IEC 0-1 SSK-Type 1 kv 10 ka 10 15A 100A 0A 10 ka 10 unbeeinflußterkurzschlußstrom Prospective short-circuit-current(sym. r.m.s.)

HH 0 01 0.05.00 / 10 10 s 10 Effektiv-Wert des unbeeinflußten Stromes 10 - RMSprospective current 5 5 10 5 10 5 10 A 5 10 5

Strombegrenzungs-Diagramm Cut-off characteristics HH-Sicherungseinsätze DIN VDE 070Teil IEC 0-1 SSK-Type kv 10 ka 10 100A 15A A 0A 10 ka 10 unbeeinflußterkurzschlußstrom Prospective short-circuit-current(sym. r.m.s.)

HH 0 0 9.0.00 / 10 10 s 10 Effektiv-Wert des unbeeinflußten Stromes 10 - RMSProspective current 5 5 10 5 10 5 10 A 5 10 5

Strombegrenzungs-Diagramm Cut-off characteristics HH-Sicherungseinsätze DIN VDE 070Teil IEC 0-1 SSK-Type kv 10 ka 10 0A A 10 ka 10 unbeeinflußterkurzschlußstrom Prospective short-circuit-current(sym. r.m.s.)

H00.10 15.11.00 / 17 10 10 s 10 Effektiv-Wertdes unbeeinflußten Stromes 10 - RMS prospective current 5 5 10 5 10 5 10 A 5 10 5

Strombegrenzungs-Diagramm Cut-off characteristics HH-Sicherungseinsätze DIN VDE070Teil IEC 0-1 SSK -Type 1 kv 10 ka 10 10A 10 ka 10 unbeeinflußterkurzschlußstrom Prospective short-circuit-current (Sym. r.m.s.)