PowerGuard Electrification Isolation Solutions

Similar documents
Conductor Bar Series 831

QuickBridge TM. Modern Overhead Crane Bridge Electrification

VersaReel Commercial Duty Cable Reel

Charging Contacts for AGVs, Shuttles and more

PRIAS. Power Rail Intelligent Analysis System

Aircraft Cable Management Systems

1 Product Description System Layout Safety Instructions Intended Use Installation... 3

Product Overview Conductor Rails

1 Product Description Check of the supplied Parts Notes Intended Use Current Collector... 3

Conductor Bar Series 812

Product Overview Compressed Air and Electric Supply

E-RTG TM RTG Electrification

Push Button Pendants Manual 80 Series

Mill Duty Electrification Systems

Product Overview I-Beam Festoon Systems

Hevi-Bar I Manual for Port Applications 1000A, 1500A, 2000A 5kV System

Energy & Data Transmission Systems for Container Handling Equipment

Festoon Manual Standard Duty C-Track

Conductor Rail System for Shuttles MultiLine Program 0835

Slip Rings Manual V Series

Bulk Material Handling and Mining Electrification Systems

Air Hoists ENDO Series

Conductor Bar Manual Safe-Lec 2 V Contact Bar

Spring Cable Reel Manual 1400 Series

Hazardous Location Cable Reel Manual 1500 Series Power Reel

Welded Cap Conductor Rail. for 3rd Rail Mass Transit Systems

Festoon Systems for I-Beams Program

Spring Cable Reel Manual 3500 Series Power Reel

Spring Cable Reel Manual Series D, E & F

Spring Cable Reel Manual 1900/2400 Power Reel

Conductor Bar Safe-Lec 2 Hevi-Bar II

Saf-T-Bar Conductor Bar T Series

Conductor Bar Safe-Lec 2 Hevi-Bar II

Conductor Bar Safe-Lec 2 Hevi-Bar II

Conductor Bar. 8 Bar Side Contact

Conductor Bar Hevi-Bar II

Cluster Bar. Conductor Bar Systems. Insul-8 Mobile Electrification. For the Electrification of: Solutions From A Single Source

Saf-T-Bar Conductor Bar H Series

Hevi-Bar. Conductor Bar Systems. Insul-8 Mobile Electrification. For the Electrification of. Solutions From A Single Source

1 Product Description System Layout Safety Instructions Intended Use Installation... 3

DUCT-O-BAR HD Series Conductor Systems 500, 1000 & 1500 Ampere Sizes

Press Release. Conductix-Wampfler Electrifies Colombian Container Terminal TCBuen

Interlocks 200 Series

Interlocks 325 Series

UNIT 3: GENErAL ELECTriCAL SySTEM DiAGNOSiS

1 Product Description Check of the supplied Parts Notes Intended Use Current Collector... 3

CAUTION CM-SE CM-S21 CM-S41

Cable Festoon Systems. C-Track Stretch Wire Rope

Electrobar FS Conductor Bar System

Heavy-Duty Conductor Rail CopperHead

Bulk Material Handling and Mining Electrification Systems

Wireless Charger. Inductive charging system for AGVs

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Cable Festoon Systems. C-Track Stretch Wire Rope

Installation Instructions Electric Heaters 5 20 kw

Multipole Conductor Rail MultiLine Program 0831

PV Vault Yielding safety quickly

OPERATION MANUAL. Before equipment use, please read this operation manual. Serial Number: Date Purchased:

CONDUCTIX Insul-8 Conductor Bar

SAFELEC. INSULATED CONDUCTOR BARS 60 up to 800 Amp

T & M Series Couplings. Metal membrane couplings for the oil & gas industry

Residential microinverter system

Multipole Conductor Rail MultiLine Program 0831

Industrial Cranes Nuclear Cranes Port Cranes Heavy-duty Lift Trucks crane Service. Lifting Lodes for the MINING INDUSTRY

Magnetek ELECTROBAR FINGER SAFE (FS) Conductor Bar System

E-RTG TM RTG Electrification

2 x 25 kv ac / 1 x 25 kv ac Grounding and Bonding

ONTRAC WIRE MESH CABLE TRAY SYSTEM

Solar PV Standard Electrical Plan

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

THE BEST MOVES IN THE WORLD

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

TEMPERATURE RISE TESTS

Product Overview Festoon-Systems for I-Beams

Power for Growth. The heart of every. great machine

Heavy-Duty Hinge-Operated Safety Interlock Switch (Pneumatic) Cam limits guard door opening to 5 degrees before safety contacts are opened.

VICTAULIC Shouldered Solutions

i400s Calibration Information Introduction

Owner s Manual. END TRUCKS Top Running & Underhung SERIES 3

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

Spring Cable Reels EXEL

Energy Supply Systems

6.2. Conveyor Sensor Systems. 200 Series Zero Pressure Accumulation. 200 Series Zero Pressure Accumulation

Cummins delivers reliable power in one easy-to-use system

ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

ELECTRICAL SAFETY-RELATED WORK PRACTICES

VAHLE MOTOR POWERED CABLE REELS

PAK. PakMaster XL PLUS-CE Series. PLUS The New SureLok Torch! Air Plasma Cutting Systems. Over 40 Years of Plasma Cutting Innovation

Series L9 UL489 Miniature Circuit Breakers

TLC. T Series Couplings. Product Description. Design Features

SAVE THESE INSTRUCTIONS

HEVIBAR 3. INSULATED CONDUCTOR BARS 630 up to 1250 Amp

Spring Cable Reels SR-Express 48H EXW

MFP1G, MFP1G1, MFPR2G, MFFPR2G & MFHP1G D-M-E Smart Series Mainframes

Solar module user manual Conergy PM 225P-250P

Steel Outlet Boxes 4 11 /16" Welded

END TRUCKS Top Running & Underhung SERIES 3

Slip Rings R Series. PN Rev. 5. R Series Slip Ring Manual

Surepowr Series 100 Installation Manual

Transcription:

PowerGuard Electrification Isolation Solutions

PowerGuard PowerGuard, along with Conductix-Wampfler Power Interrupting Sections, are designed to provide safe maintenance zones for servicing overhead cranes and other mobile equipment. This specially engineered switch array is ideal for three-phase bar systems that use tandem collector assemblies. By employing both the Power Interrupting Sections and PowerGuard, the user can ensure that tandem collectors from adjacent cranes will never accidently transfer live power into the maintenance zone. This is done by assigning a dedicated switch for the Power Interrupting Section's "buffer zone" which isolates it from the energized runway. A third switch then grounds the maintenance zone to make sure the maintenance person is safe while working on the crane. Systems 100 amps to 600 Amps PowerGuard is easy to install and designed for ease of use and safety. A visual indicator on the front panel identifies when power has been removed from the maintenance zone. Voltage test points are also included that can be used to double-verify that power has been removed from the maintenance zone. Features Grounded maintenance zone Designed for the application Three switch sets for safe operation Single-handle or Kirk Key design for error free operation Visual voltage indicator Voltage test points Benefits Dual-voltage indicators Personnel safety Simple switch operation Real maintenance zone isolation Complies with lock-out / tag-out procedures. 2

Systems Over 600 Amps Voltage Indicator Lights show whether power is on or off in the maintenance zone. Single switch for PowerGuard rated at 600 Amp and below. Voltage Test Points at the panel allow testing for voltage in the maintenance zone. Kirk Key design is used for a PowerGuard rated above 600 Amps. It uses a dualkey system to ensure that the switches can only be operated in the correct order securing proper tag-out of the system. 3

How it Works Power Interrupting Sections (PIS) create unpowered zones of conductor bar so that overhead cranes can be safely maintained. The PIS provide a buffer zone to prevent tandem collectors on adjacent cranes from creating a power bridge to the maintenance zone. PIS consist of three short sections of conductor bar with an air gap between each of section. Each of the three conductor bar sections has a power feed. The buffer zone is always the middle piece of conductor bar. Of the two remaining bar segments, one will be attached to the powered runway. The other will be attached to the maintenance zone. The location of the powered section and the maintenance section depends on whether the maintenance zone needs to be to the right or left. Main Active Zone Position 1 - Complete runway is powered. On II Position 2 - Power is removed from the buffer and maintenance zones. Off 0 Position 3 - Maintenance zone is grounded. On I 4

For details on the Power Interrupting Sections for Safe-Lec 2 and Hevi-Bar II, refer to catalog CAT1003. Buffer Zone Maintenance Zone Ground 5

Maintenance Zone Safety If a tandem collector from an adjacent crane moves into an unpowered buffer zone, it will transfer power from the active runway to the buffer zone. Conductix-Wampfler Solutions The Conductix-Wampfler PowerGuard is engineered to create true isolation of the maintenance zone. Even when power is bridged to the buffer zone, the maintenance zone will remain unpowered and grounded. This creates a safe and effective section for maintenance. On I Main Active Zone Off-the-Shelf Solutions With other "off-the-shelf" solutions, the buffer zone and maintenance zone are tied together electrically at the switch. A tandem collector from an adjacent crane could inadvertently power the maintenance zone, making the it unsafe and unusable. Off Main Active Zone N/A Sizing and Switch Operations How to Size a PowerGuard Sizing the PowerGuard correctly is important to ensure that the resulting solution meets the customer s specific needs. Option 1 Add together the maximum current draws (in amps) of all cranes that operate on the runway. Choose the switch with a current capacity that matches the total. If an exact match is not available, choose next highest amperage switch. Option 2 If a system has an end maintenance zone, the PowerGaurd can be sized based on the maximum current draw of all cranes that will be in the maintenance zone at a given time. If multiple power feeds are used, and/or the maintenance zone will not be located at the end of the runway, please contact Conductix- Wampfler for assistance with selecting the correct PowerGuard. 6

The length of the buffer zone is based on the use of one set of tandem collectors. If the vehicle requires more than one set of tandem collectors or the collectors being used are not standard, please contact Conductix-Wampfler for assistance. Buffer Zone Maintenance Zone Ground Buffer Zone Maintenance Zone Current Capacity (Amps) Voltage Part No. H Dim. (in.) W Dim. (in.) D Dim. (in.) Weight W 100 577418 36 24 10 200 577400 60 36 12 400 577421 60 49 18 600 577422 72 61 18 800 577424 72 61 18 1200 577425 90 78 20 1600 577426 90 78 20 H D 7

www.conductix.us Refer to www.conductix.com for our Global Sales Offices CAT1017 Conductix-Wampfler 2017 Subject to Technical Modifications Without Prior Notice USA / LATIN AMERICA 10102 F Street Omaha, NE 68127 Customer Support Phone +1-800-521-4888 Phone +1-402-339-9300 Fax +1-402-339-9627 info.us@conductix.com latinamerica@conductix.com CANADA 1435 Norjohn Court Unit 5 Burlington, ON L7L 0E6 Customer Support Phone +1-800-667-2487 Phone +1-450-565-9900 Fax +1-450-851-8591 info.ca@conductix.com MÉXICO Calle Treviño 983-C Zona Centro Apodaca, NL México 66600 Customer Support Phone (+52 81) 1090 9519 (+52 81) 1090 9025 (+52 81) 1090 9013 Fax (+52 81) 1090 9014 info.mx@conductix.com BRAZIL Rua Luiz Pionti, 110 Vila Progresso Itu, São Paulo, Brasil CEP: 13313-534 Customer Support Phone (+55 11) 4813 7330 Fax (+55 11) 4813 7357 info.br@conductix.com