Multi Air Conditioner SVC MANUAL(Exploded View)

Similar documents
Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi Air Conditioner SVC MANUAL(Exploded View)

Multi Air Conditioner SVC MANUAL(Exploded View)

Multi Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Universal Air Conditioner SVC MANUAL(Exploded View)

Single A Air Conditioner SVC MANUAL(Exploded View)

Multi Air Conditioner SVC MANUAL(Exploded View)

Universal Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Multi Zone Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Multi Air Conditioner SVC MANUAL(Exploded View)

Multi Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Multi Air Conditioner SVC MANUAL(Exploded View)

SVC MANUAL(Exploded View) Room Air Conditioner

Ducted Type (50Hz, R22/R410A)

Four-Way Ceiling Cassette

SVC Manual (Exploded View)

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

SVC Manual (Exploded View)

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Low Static Pressure Duct(V shape evaporator)

DUCTED INDOOR UNIT ENGINEERING MANUAL

Superior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

Version Modification Date Remark

Multi Zone Air Conditioner SVC MANUAL(General)

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

Low Static Pressure Duct (V shape evaporator)

Multi Zone Air Conditioner SVC MANUAL(General)

LG Multi Split Air Conditioners

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU

DVM. Technical Data Book

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

VRF. Technical Data Book. DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz)

DC INVERTER VRF SYSTEMS C-VRF

VHIA High-Static Ducted Indoor Units - 60HZ

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Version Modification Date Remark

High Static Pressure Duct Fan Coil Unit

VRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH***

DESIGN & TECHNICAL MANUAL

MULTI F MAX HEAT PUMP SYSTEM ENGINEERING MANUAL. Multi-Zone Heat Pump Systems 1.5 to 4.5 Tons. Dual and Tri-Zone Multi F.

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Engineering Data Book

Ductless Split Systems

SINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P)

Technical Service Manual

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

Multi-Room Ductless heat-pump systems Submittal Data: MULTI18HP230V1AO 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date

Ductless Split Systems

HOME COMFORT & LIGHT COMMERCIAL SYSTEMS 2016

Ductless Split Systems

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

DC INVERTER DUCTED AIR CONDITIONERS

ceiling wall AWYZ14LB/18LB With the world's first self-cleaning filter system

Concealed Ducted Split Series R22

2010 Duct-Free Splits Line Card

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

Ductless Split Systems

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

HOME COMFORT & LIGHT COMMERCIAL SYSTEMS

MULTI SPLIT SYSTEM AIR CONDITIONERS

Ceiling Cassette INDOOR UNIT

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

Cooling Compressor Type DC Inverter Driven Rotary Rated Capacity 53,000 BTU/H RLA 23.0 A

Service manual MIV V4+ Indoor units

Low Static Built In Ducted 7,500 to 24,200 Btu/h Vertical / Horizontal Air Handler 12,000 to 54,000 Btu/h

Cooling Compressor Type DC Inverter Driven Rotary Rated Capacity 48,000 BTU/H RLA 23.0 A

GCL Technical Manual. Split System Air Conditioner GCL TAC 640. Electronic Control. Air Conditioners

Air Conditioning System

CASSETTE type SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit CONTENTS

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

PACKAGE HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant RQNL-B HIGH EFFICIENCY 13-SEER SERIES RQPL-B HIGH EFFICIENCY 14-SEER SERIES

Engineering Data Book

VRF Technical Data Book

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual

VRF. Technical Data Book. Duct S for Europe (R410, 50Hz)

SINGLE. Technical Data Book. HSP Duct for America (R410A, 60Hz, H/P)

Air Conditioning System

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

Vertical Floor Fan Coil Unit (Model FW)

SUBMITTAL DATA: MXZ-5C42NAHZ MULTI-INDOOR INVERTER HEAT PUMP SYSTEM. Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz

Transcription:

Internal Use nly http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : AMNW12GTRA0(LMCN125HV) AMNW18GTQA0(LMCN185HV) CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for authorized service personnel.

1. Specification Indoor unit type Model Decoration Panel Name Power Supply Ø / V / Hz Capacity(*) Btu/h class Current Running Current A Fan Motor Type Fan Type Motor utput(w) x No. of Unit Air Flow Rate CMM (H / M / L) CFM External Static Pressure mmaq Capacitor µf / Vac Drive Coil Row x Column x FPI Dimensions Body mm(inch) (W x H x D) Decorative Panel mm(inch) Net Weight Body kg (lbs) Decorative Panel kg (lbs) Air Filter Sound Level (H / M / L) db(a)+3 Piping Liquid mm (inch) Connections Gas mm (inch) Drain(D/ID) mm(inch) Dehumidification Rate l/h Safety Devices Temperature Sensor Referigerant Referigerant Control Transmission Interunit Cable No. x AWG AMNW12GTRA0[LMCN125HV] Ceilling Cassette - 4way AMNW18GTQA0[LMCN185HV] PT-UQC PT-UQC 1/ 208~230/ 60 1/ 208~230/ 60 12,000 18,000 0.25 0.25 BLDC BLDC Turbo Fan Turbo Fan 43 x 1 43 x 1 9.5/ 8/ 7 13/ 12/ 11 335/282/247 459/424/388 Direct Drive Direct Drive 2R x 8C x 18 2R x 10C x 18 570 x 214 x 570 ( 22 7/16 x 8 7/16 x 22 7/16) 570 x 256 x 570 ( 22 7/16 x 10 x 22 7/16) 700 x 30 x 700 (27 6/19 x 1 3/16 x 27 6/19) 700 x 30 x 700 (27 6/19 x 1 3/16 x 27 6/19) 14 (30.9) 15 (33.1) 3 (6.6) 3 (6.6) Long life filter Long life filter 38/ 35/ 32 38/ 37/ 34 6.35 (1/4) 6.35 (1/4) 9.52 (3/8) 12.7 (1/2) 32 / 25(1.26/0.984) 32 / 25(1.26/0.984) 2 2 Fuse, thermal protector for fan motor Fuse, thermal protector for fan motor Thermistor Thermistor R410A R410A EEV(in utdoor unit) EEV(in utdoor unit) 418(Including Earth) 418(Including Earth) Note: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 26.7 C(80 F) DB/19.4 C(67 F) - utdoor Temperature 35 C(95 F) DB/23.9 C(75 F) Heating: - Indoor Temperature 21.1 C(70 F) DB/15.6 C(60 F) WB - utdoor Temperature 8.3 C(47 F) DB/6.1 C(43 F) WB Piping Length - Interconnecting Piping Length 7.5m(24.6 ft.) - Level Difference of Zero 2. Wiring cable size must comply with the applicable local and national code. 3. The specification may be subject to change without prior notice for purpose of improvement. 4. For more Capacity(*),refer to the combination table Conversion Formula kw = Btu/h class 0.0002931 cfm = CMM x 35.3 nly for training and service purposes - 2 - LGE Internal Use nly

2. Function Table Category Air flow Air Purifier Installation Reliability Convenience Individual Control CAC Network Function Special Function Kit thers Function Air supply outlet Airflow direction control(left & right) Airflow direction control(up & down) Auto swing(left & right) Auto swing(up & down) Airflow steps(fan / cool / heat) Chaos swing Chaos wind(auto wind) Jet cool(power wind) Swirl wind Deodorizing filter Plasma air purifier Prefilter(washable / anti-fungus) Drain pump E.S.P. control Electric heater(operation) High ceiling operation Hot start Self diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto restart operation Child lock Energy-Saving Cooling Mode Forced operation Group control Sleep mode Timer(on/off) Timer(weekly) Two thermistor control Wide wired remote controller Deluxe wired remote controller Simple wired remote controller Simple wired remote controller(for hotel use) Wireless remote controller(simple) Wireless LCD remote control Wireless LCD remote control(ez) General central controller (Non LGAP) Dry contact Central control(lgap) PDI(power distribution indicator) PI 485 CTIE Zone control Thermistor AMNW12GTRA0 [LMCN125HV] AMNW18GTQA0 [LMCN185HV] 4 4 Auto Auto 4/5/4 4/5/4 ption ption Accessory (PQRCUSA0) Accessory (PQRCUSA0) Accessory (PQRCFCS0C) Accessory (PQRCFCS0C) Accessory (PQDSB) Accessory (PQDSB) Note : : Applied, : Not applied, - : No relation * ption : Model name & price are different according to options, and assembled in factory with main unit. * Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. nly for training and service purposes - 3 - LGE Internal Use nly

3. Piping Diagrams Heating Heat exchanger Gas pipe connection port (flare connection) Cooling Turbo fan Th3 Th1 Th2 Liquid pipe connection port (flare connection) LC. Description PCB Connector Th1 Thermistor for sunction air temperature CN_RM Th2 Thermistor for evaporator inlet temperature CN_PIPE/IN Th3 Thermistor for evaporator outlet temperature CN_PIPE/UT nly for training and service purposes - 4 - LGE Internal Use nly

4. Wiring Diagrams CN-D/PUMP CN-PTIN CN-MTR1 CN-FLAT CN-DISPLAY CN-RM CN-PIPE/IN CN-PIPE/UT CN-PWER CN-VANE2 CN-VANE1 CN-VANE1 CN-AIRC CN-REM CN-CC nly for training and service purposes - 5 - LGE Internal Use nly

5. Exploded View 12k Model 130411 158591 131410 148000 158580 130911B 354211 130911A 263230C Eva-out sensor 352116 352115 263230B Eva-in sensor 249310 352150 349600 346810 W49810 267110 W50011 359012 140570 249951 330871B 330871A W6640 268711C W3110 268711E Air-Inlet sensor 349480 266010 135511 263230A Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer Øs request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://biz.lgservice.com,) nly for training and service purposes - 6 - LGE Internal Use nly

18k Model 130411 158591 131410 148000 158580 130911B 354211 130911A 263230C Eva-out sensor 352116 (18 k Btu/h class only) W51620 352115 263230B Eva-in sensor 249310 352150 349600 346810 W49810 267110 W50011 359012 140570 249951 330871B 330871A W6640 268711C W3110 268711E Air-Inlet sensor 349480 266010 135511 263230A Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer Øs request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://biz.lgservice.com,) nly for training and service purposes - 7 - LGE Internal Use nly

Front Panel (Accessory) Model : PT-UQC 135303 749740A 135800 749740B 135316 159830 146811 145200 268711 135500 147581 266001 237202 Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://biz.lgservice.com,) nly for training and service purposes - 8 - LGE Internal Use nly

P/N : MFL61777609 SEPTEMBER, 2009