DIRECTIONL CONTROL VLVES Directional Control Valves PS-SERIES 3/2, 5/2 and 5/3-way Single and double acting control Long lifespan Low energy consumption Standard manual override Wide range of operating voltages The PS-series consists out of 3/2-, 5/2- and 5/3-way solenoid valves for pneumatic systems. ll valves are internally piloted and are equipped with a piston spool and high quality sealing system to facilitate low wear, a long lifespan and a wide pressure range. The valves can be single or double acting (one or two solenoids). y changing the solenoid coil, different operating voltages can be achieved. Optionally, the valves are prepared for manifold mouning. There are three size platforms (/C/D), platform and C have corresponding manifold series. Optionally, the valve body has a Namur configuration (VDI/VDE 3845). 3/2-way 5/2-way 5/3-way Single cting Double cting Single Double Center Center Center Exhaust N/Closed N/Open N/Closed N/Open cting cting Closed Pressurized PS-32S PS-32S PS-32D PS-32D PS-52S PS-52D PS-53CD PS-53ED PS-53PD R P R P R P R P S P R S P R SPR SPR S P R Parameters in circuit function diagrams: P = Pressure, /= ppliance, R = Return Technical Specifications Temperature -5 C.. 5 C Response Time 5ms Valve body Die-cast aluminum alloy Seals NR (nitrile rubber) Spool luminum Voltage 23V C / 24V C / 24V DC / 12V C / 12V DC ir ir (filtered 4µm) Lubrication Not required. Once used, continue to optimize life span. ISO VG32 or equivalent is recommend. Operation Spool system with pilot operation (internally piloted) Model Code Series PS Circuit Function 32: 3/2-Way 52: 5/2-Way 53: 5/3-Way ody Size C D PS 52 S C 14 N - 23C Function Stability : Standard S: Single : Normally Closed cting : Normally Open D: Double C: Center Closed cting P: Center Pressurized E: Center Exhaust Namur N: Namur design Port Size M5=M5x.8 18 = G1/8" 14 = G1/4" 38 = G3/8" 12 = G1/2" Voltage 23C = 23V C 12C = 12V C 24C = 24V C 24DC = 24V DC 12DC = 12V DC MNUL-PS-EN www.jpfluidcontrol.com 1
DIRECTIONL CONTROL VLVES COIL SPECIFICTIONS Electrical Specifcations Series CP1 CP2 Model Platform Voltage Power Isolation Class Duty Cycle IP grade Connector CP1-23C 23V 5Hz ± 15% 5.V F 1% ED IP-65 DIN4365C CP1-12C 12V 6Hz ± 15% 5.V F 1% ED IP-65 DIN4365C CP1-24C 24V 5Hz ± 15% 5.V F 1% ED IP-65 DIN4365C CP1-24DC 24V ± 1% 2.8W F 1% ED IP-65 DIN4365C CP1-12DC 12V ± 1% 2.8W F 1% ED IP-65 DIN4365C CP2-23C C/D 23V 5Hz ± 15% 5.5V F 1% ED IP-65 DIN4365 CP2-12C C/D 12V 6Hz ± 15% 5.5V F 1% ED IP-65 DIN4365 CP2-24C C/D 24V 5Hz ± 15% 5.5V F 1% ED IP-65 DIN4365 CP2-24DC C/D 24V ± 1% 4.8W F 1% ED IP-65 DIN4365 CP2-12DC C/D 12V ± 1% 4.8W F 1% ED IP-65 DIN4365 Dimensions Ø11.5 Ø8 Ø16 Ø8 17 22 11.5 1 11 24 22.5 3 26 25 Ø8 28 Ø9 CP1 series CP2 series Duty cycle The solenoid valves are suitable for continuous use. High switching frequencies and high pressures can reduce the lifespan. Compliance The coils are CE marked and comply with the LVD Directive (26/95/EC) and EMC Directive (24/18/EC), provided that the cables and connectors are properly connected. MNUL-PS-EN www.jpfluidcontrol.com 2
DIRECTIONL CONTROL VLVES 3/2-WY VLVE 3/2-Way solenoid valves have three ports and two positions. The valves are characterized by a high flow rate, quick response time and a long lifespan. The 3/2-way valves can be normally closed or normally open. oth types are available with one or two coils (single or double acting). ll valves with body size and C are suitable for manifold mounting. The valves have a manual override switch. Versions Code Size exhaust Orifice (mm 2 ) Kv (m 3 /h) Coil type Power (DC/C) Frequency (Cycles/s) PS-32 -M5 M5 M5 5.5.26 CP1 2.8W / 5.V 5 PS-32-18 G1/8" G1/8" 12.57 CP1 2.8W / 5.V 5 PS-32 -C14 C G1/4" G1/4" 25 1.19 CP2 4.8W / 5.5V 5 PS-32 -C38 C G3/8" G1/4" 25 1.43 CP2 4.8W / 5.5V 5 PS-32 -D12 D G1/2" G1/2" 5 2.38 CP2 4.8W / 5.5V 5 Circuit Function R P R P R P R P N/Closed Single cting N/Open Single cting N/Closed Double cting N/Open Double cting PS-32S- _ PS-32S- _ PS-32D- _ PS-32D- _ Flow diagram PS-32 -M5 PS-32-18 PS-32 -C14 PS-32 -C38 PS-32 -D12 MNUL-PS-EN www.jpfluidcontrol.com 3
G1/4 : 23.7 G1/4 : 14.7 G1/4 : 16 PS-32_S-M5: 3-M5 PS-32_S-18: 3-G/8 JP FLUID CONTROL DIRECTIONL CONTROL VLVES Dimensions Manual override PS-32S-C14: G1/4 PS-32S-C38: G3/8 G1/4 :1 G1/4 :2 G1/4 G3/8 PS-32_S- PS-32_S-C PS-32_S-D PS-32_D-M5: 3-M5 PS-32_D-18: 3-G1/8 PS-32S-C14: G1/4 PS-32S-C38: G3/8 Manual override M5: 58.6 G1/4 : 57.7 M5: 14.2 G1/4 : 16 Manual override G1/4 :1 G1/4 :2 G1/4 : G3/8 : 2 PS-32_D- PS-32_D-C PS-32_D-D MNUL-PS-EN www.jpfluidcontrol.com 4
DIRECTIONL CONTROL VLVES 5/2-WY VLVE 5/2-Way solenoid valves have five ports and two positions. The valves are characterized by a high flow rate, quick response time and a long lifespan. The 5/2-way valves are available with one or two coils (single or double acting). ll valves with body size and C are suitable for manifold mounting. The valves. The valves have a manual override switch. Versions Code Size exhaust Orifice (mm 2 ) Kv (m 3 /h) Coil type Power (DC/C) Frequency (Cycle/s) PS-52_-M5 M5 M5 5.26 CP1 2.8W / 5.V 5 PS-52_-18 G1/8" G1/8" 9.57 CP1 2.8W / 5.V 5 PS-52_-C14 C G1/4" G1/4" 18 1.19 CP2 4.8W / 5.5V 5 PS-52_-C38 C G3/8" G1/4" 18 1.43 CP2 4.8W / 5.5V 5 PS-52_-D12 D G1/2" G1/2" 3 2.38 CP2 4.8W / 5.5V 5 Circuit Function S P R Mono-Stable PS-52S- _ S P R i-stable PS-52D- _ Flow diagram PS-52 _-M5 PS-52 _-18 PS-52 _-C14 PS-52 _-C38 PS-52 _-D12 MNUL-PS-EN www.jpfluidcontrol.com 5
DIRECTIONL CONTROL VLVES Dimensions PS-52S- PS-52S-C PS-52S-D PS-52D- PS-52D-C PS-52D-D C (mm) D (mm) E (mm) F (mm) G (mm) PS-52S-M5 M5x.8 27mm 14.7 14 21.2 PS-52S-18 G1/8 28mm 14.2 1 16 2.2 3 PS-52S-C14 G1/4 G1/4 22 29 - - PS-52S-C38 G1/4 G3/8 24 28 4 - - PS-52D-M5 M5x.8 27mm 57.7 14 64.3 PS-52D-18 G1/8 28mm 57.2 1 16 63.2 3 PS-52D-C14 G1/4 G1/4 22 83.9 - - PS-52D-C38 G1/4 G3/8 24 82.9 4 - - MNUL-PS-EN www.jpfluidcontrol.com 6
DIRECTIONL CONTROL VLVES 5/3-WY VLVE 5/3-Way solenoid valves have five ports and three positions. The valves are characterized by a high flow rate, quick response time and a long lifespan. The 5/3-way valves are have two coils that each control a state. When the coils are de-energized, the valve returns to center position. The center position is available in three variants: center closed, center pressurized and center exhaust. ll valves with body size and C are suitable for manifold mounting. ll valves have a manual override. Versions Code Size exhaust Orifice (mm 2 ) Kv (m 3 /h) Coil type Power (DC/C) Frequency (Cycle/s) PS-53_D-M5 M5 M5 5.24 CP1 2.8W / 5.V 5 PS-53_D-18 G1/8" G1/8" 9.43 CP1 2.8W / 5.V 5 PS-53_D-C14 C G1/4" G1/4" 18.85 CP2 4.8W / 5.5V 5 PS-53_D-C38 C G3/8" G1/4" 18.85 CP2 4.8W / 5.5V 5 PS-53_D-D12 D G1/2" G1/2" 3 1.43 CP2 4.8W / 5.5V 5 Circuit Function SPR SPR S P R Center Closed PS-53CD- _ Center Exhaust PS-53ED- _ Center Pressurized PS-53PD- _ Flow diagram 8 Kv =.24 8 Kv =.43 8 Kv =.85 8 Kv = 1.43 6 6 6 6 Pressure (bar) 4 Pressure (bar) 4 Pressure (bar) 4 Pressure (bar) 4 2 2 2 2 1 2 3 Flow rate (l/min) 4 5 2 4 6 Flow rate (l/min) 8 1 5 1 15 Flow rate (l/min) 2 5 1 15 2 Flow rate (l/min) 25 3 PS-53_D-M5 PS-53_D-18 PS-53_D-C14 / PS-53_D-C38 PS-53_D-D12 MNUL-PS-EN www.jpfluidcontrol.com 7
DIRECTIONL CONTROL VLVES Dimensions PS-53_- PS-53_-C PS-53_-D C (mm) D (mm) E (mm) F (mm) G (mm) PS-53_-M5 G1/8 28mm 57.2 1 16 63.2 3 PS-53_-18 M5x.8 27mm 57.7 14 64.3 PS-53_-C14 G1/4 G1/4 22 83.9 PS-53_-C38 G1/4 G3/8 24 82.9 4 MNUL-PS-EN www.jpfluidcontrol.com 8
DIRECTIONL CONTROL VLVES NMUR ISO The PS series is available with NMUR configuration (VDI/VDE 3834), a standard interface to mount the 5/2-way valve directly onto appliances such as a pneumatic actuator. The valve is provided with 2 O-rings to create a reliable sealing. The valve can be mounted in two ways by rotating the valve 18 degrees. The two mounting positions offer the possibility to pressurize or de-pressurize the appliance when the solenoid valve is energized. ll valves have a manual override. Versions Code Size exhaust Orifice (mm 2 ) Kv (m 3 /h) Coil type Power (DC/C) Frequency (Cycle/s) PS-52_-M5 M5 M5 5,5.26 CP1 2.8W / 5.V 5 PS-52_-18 G1/8" G1/8" 12,57 CP1 2.8W / 5.V 5 PS-52_-C14 C G1/4" G1/4" 25 1,19 CP2 4.8W / 5.5V 5 PS-52_-C38 C G3/8" G1/4" 3 1,43 CP2 4.8W / 5.5V 5 Circuit Function S P R Mono-Stable PS-52S- _N S P R i-stable PS-52D- _N Flow diagram PS-52_-M5N PS-52_-18N PS-52_-C14N PS-52_-C38N MNUL-PS-EN www.jpfluidcontrol.com 9
DIRECTIONL CONTROL VLVES Dimensions PS-52S-M5N PS-52S-18N PS-52D-M5N PS-52D-18N PS-52S-C14N PS-52S-C38N PS-52D-C14N PS-52D-C38N Namur Flange Dimensions The flange dimensions are according to (VDI/VDE 3834): T (mm) (mm) M G1/4" 32 24 M5 G1/2" 45 4 M6 MNUL-PS-EN www.jpfluidcontrol.com 1
DIRECTIONL CONTROL VLVES MNIFOLD The PS-series solenoid valves can be mounted to a manifold of corresponding size (/C/D). There is a 3/2-way configuration and a combined 5/2- and 5/3- way configuration. Manifolds are available with various lengths to accomodate up to 16 valves. Nonused used stations can be shut off with a blanking plate. Series PS Model Code Manifold PS MN 32-6 Function 32: 3/2-way 52: 5/2- and 5/3-way ody Size //C Stations 1..16 Dimensions 3/2-way 3/2-way C D E F G H I J K L M N P Q T U V W PS-MN32 19.5 22 8.5 7.5 24 1/4" 25 81 27 131.4 39 32 4.5 1 18 5 18 19 22.7 88.4 PS-MN32C 26 28 12 8 36 3/8" 29 99.2 4 174.8 52 47 4.5 13.5 27 6 27 27 32.5 119.9 Stations: 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 R (body size ) 28 47 66 85 14 123 142 161 18 199 218 237 256 275 294 313 R (body size C) 42 7 98 126 154 182 21 238 266 294 322 35 378 46 434 462 S (body size ) 38 57 76 95 114 133 152 171 19 29 228 247 266 285 34 323 S (body size C) 54 82 11 138 166 194 222 25 278 36 334 362 39 418 446 474 MNUL-PS-EN www.jpfluidcontrol.com 11
DIRECTIONL CONTROL VLVES Dimensions 5/2-way 5/2-way C E F G H I J K M Q R S T U V W X Y PS-MN52 58 43.2 2 4.5 18.3 19 5 1 28.2 139.4 154.5 1/4" 4 3 29 14 9 79 25 27 PS-MN52C 75 64.8 26 4.5 27.3 27 6 13.5 4 188.8 28 3/8" 53 48 37.5 13.5 11 99.5 3 4 PS-MN52D 14 94.5 32 5.5 34.3 31.5 7 14.5 57 221.8 243 1/2" 68 63 52 18.5 18 112.5 38 5 #1 #2 #3 #4 #5 #6 #7 #8 #9 #1 #11 #12 #13 #14 #15 #16 L (size ) 38 57 76 95 114 133 152 171 19 29 228 247 266 285 34 323 L (size C) 54 82 11 138 166 194 222 25 278 36 334 362 - - - - L (size D) 63 98 133 168 23 238 273 38 - - - - - - - P (size ) 28 47 66 85 14 123 142 161 18 199 218 237 256 275 294 313 P (size C) 42 7 98 126 154 182 21 238 266 294 322 35 - - - - P (size D) 49 84 119 154 189 224 259 294 - - - - - - - - MNUL-PS-EN www.jpfluidcontrol.com 12
DIRECTIONL CONTROL VLVES SFETY INSTRUCTIONS This product is not a safety device and may not be used as such. Damage caused by improper use, falling, improper operating conditions or others, can cause that the solenoid valve is not functioning properly. Correct transport, proper storage and installation, and proper use and maintenance, are essential for reliable and error-free operation. It is the responsibility of the user to select the right product for the application. Check the compatibility of the medium used, temperature and other operating conditions with the materials and specifications of the product. It is the responsibility of the user to select the right product for the application. The product may not function properly as a result of dirt, wear, damage (for example, by dropping) or improper use. Therefore, the product should not be used in applications where a malfunction can cause danger or damage. Check the compatibility of the medium used, temperature and other operating conditions with the materials and specifications of the product. Never exceed the limits for pressure, temperature or voltage as indicated on the product and/or in the technical documentation. The device may get hot due to the present of liquids and gases. Let the device cool down before maintenance to prevent burns. t is not allowed to change the construction of this device. The product is only safe when properly installed and operated by qualified persons. Please read the safety instructions and technical documentation carefully before installation, use or servicing. Maintenance may only be performed when the system is not pressurized, electrically disconnected and cooled down. lways make sure to start the installation safely after installation or maintenance. This product is not intended or approved for medical applications, food and/or application in gas appliances. The temperature of a solenoid valve coil can rise during operation; this is normal. Overheating will cause smoke and a burning smell. In this case, the power supply must immediately be disconnected. eware of electric shock when working with electrical equipment. DISPOSL The removal of the product should be performed in accordance with the applicable laws. Keep in mind the media that are still present in the valve. This manual can be downloaded from www.jpfluidcontrol.com Modifications reserved JP Fluid Control This document has been prepared with great care. JP Fluid control assumes no responsibility for any errors that may appear in this document. No rights can be derived from this document. MNUL-PS-EN www.jpfluidcontrol.com 13