Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Similar documents
Acid Resistant AVC6000

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Acid Resistant AVT6000

Accutrol, LLC Product Sheet H-AVC5000. US Patents 6,991,177 & 7,543,759. Specially Made for Vivarium Cage Racks

Accutrol, LLC Product Sheet. VTS Series. US Patents 6,991,177 & 7,543,759. Digital Airflow Measurement Station

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

ACCUVALVE MODEL AVT6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVT6000 AVT6 - - DWG. NO: REVISION: REV. DATE:

ACCUSTATION SUBMITTAL MATERIALS

Demand Based Static Pressure Reset Control for Laboratories

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

OPTIONS BLANK = No Options B = BACnet MS/TP D = Internal Transmitter Display (Ref Note 4)

Installation & Operation Manual - Model AV3000

Laboratory Room Controller

CCS Zone/Bypass Damper Assembly

Application. Tek-Air Systems, Inc. 41 Eagle Road Danbury, CT (203) FAX: (203) SALES FAX: (203)

Laboratory Exhaust Air Terminal

Healthcare Solutions Room Pressure Monitors and Controls

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description

Precision-I Laboratory System Universal Digital Monitor

YCCS Zone/Bypass Damper Assembly

YCCS Zone/Bypass Damper Assembly

Laboratory Solutions. pricecriticalcontrols.com

Air Quality Solutions

BASE UPGRADEABLE VALVES FOR TIERED SOLUTIONS

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

PIM Pressure Independent Module

Venturi Valve. 2 For more information visit v100. Actuator. Potentiometer. Lever Arm. Airflow Area AIRFLOW.

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

PIM Pressure Independence Module

Silver Series Thermal Dispersion Airflow Measurement Technology

OE326-23I-OR VAV/Zone Controller

Spyder BACnet Programmable Controllers

SECTION FLOW INSTRUMENTS

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Variable Air Volume (VAV) Pressure Independent Control

STR Circular VAV Terminal Units

2.6. Air Flow Control Valve Type PRD

Laboratory Room Single Duct Supply Air Terminal

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

SLIM LINE FUME HOOD MONITOR

ACCESSORIES & OPTIONS FOR VENTURI AND VENTURI FX VALVES

AD-1251 Probe with Differential Pressure Transducer

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand

KEL DIFFERENTIAL PRESSURE FLOWMETERS

Variable Air Volume Distribution Units CII, September 1 st, Home

GE Measurement & Control

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Technical information

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

RETROFIT TERMINAL UNITS

Low Pressure Sensor. Overview. Specifications. Installation and Operation

BACnet MS/TP Networking Flow Balancing Control Valves

mass flowmeter for compressed air

Prism PI Intelligent features offer advanced performance

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER

ZONE PRESENCE SENSOR FEATURES SPECIFICATIONS TABLE OF CONTENTS. VAV system using a Zone Presence Sensor.

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes

LOW PRESSURE CELERIS CONTROLLERS

VAV Terminal Units SDS

Laboratory Exhaust Systems

Analog Output Terminal

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

RPM1600 Series Room Pressure Monitors

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

RVP-R VAV REGULATORS. Intended use: VAV regulators are used for automatic airflow regulation in the ventilation and air conditioning systems.

TRACCEL BACNET CONTROLLERS

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

PS AMA F (a) 0411 ( )

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS. Features DESCRIPTION

1.1 RELATED DOCUMENTS: 1.2 DESCRIPTION OF WORK: 1.3 QUALITY ASSURANCE: University of Houston Project Name

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

ComfortPoint Programmable Lon, VAV/Unitary Controllers

THERIS BACNET CONTROLLERS

Powers TM Controls SW 141 Differential Static Airflow Switches

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps

Warm. SDR Direct Fired Gas Heating System. Sterling. Keeps You. Technical Guide for: Outdoor or Indoor Mounted Units To 16,000 CFM And 1.

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

BAS Construction Checklist

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories

Analog Input Terminal

FlowCon SM mm. Dynamic Self Balancing Control Valve SPECIFICATIONS

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

Specification: Industrial Mixing Center

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description

Description. functions including single duct pressure dependent or pressure independent systems.

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

GRUNDFOS DATA BOOKLET. Control HVAC. For variable-primary-flow systems

MANUAL INSTALLATION. Tracking Controller. TC Series. v100 Issue Date: 02/25/ Price Industries Limited. All rights reserved. Firmware: 1.3.

DCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC

Laboratory Room Single Duct Supply Air Terminal

Transcription:

Accutrol, LLC Product Sheet AVC6000 US Patents 6,991,177 & 7,543,759 Laboratories, Life Sciences, Healthcare AHR Expo AWARDS WINNER epi Innovative features for the AVC6000! Intuitive Graphical User Interface Dashboard Software Selectable I/O BACnet is Software Selectable (no dip switches) Bluetooth Configuration Optional AccuNet High-speed, Room-level Network Optional Plus, these standard AccuValve features Exceptionally Low Pressure Drop Design System Pressure as low as 0.05" (12.5 Pa) Electronic Pressure Independence Fast Speed of Response True Airflow Feedback No Straight Run Requirements Linear Control Response High Accuracy and Turndown Can be Mounted in Any Position Native BACnet MS/TP 5-Year Manufacturer Warranty Manufactured in the USA. Accutrol, LLC 21 Commerce Drive, Danbury, CT 06810 203-445-9991 www.accutrolllc.com Contents and specifications are subject to change without notice.

Accutrol AVC6000 2 The Accutrol AVC6000 is an electronically pressure independent AccuValve. It takes the revolutionary design of the exceptionally low pressure drop AccuValve and builds airflow control into the electronics. The AVC6000 is designed for critical airflow control in laboratories and other specialized areas where fast speed of response and precise airflow measurement is required. The integral native BACnet MS/ TP allows direct communication to the Building Automation System (BAS) where desired. Features & Benefits The AVC6000 is designed for critical environment airflow control in laboratories, life science and healthcare facilities where fast speed of response and precise airflow measurement is required. The AccuValve s award winning design incorporates: Exceptionally Low Pressure Drop AccuValve s award winning design incorporates a streamlined compression section and a carefully designed static regain section. These features provide lower pressure drop, lower noise level and better flow measurement conditions than any other available technology. True Airflow Measurement The integral high accuracy vortex airflow sensing provides high turndown while maintaining accuracies of 5% of reading over the flow range, ensuring precise airflow control. No Straight Run Requirements There are no straight duct runs required before or after the valve, making application of the valve very simple. The air compression in the valve provides laminar airflow throughout the airflow range providing repeatable airflow measurement regardless of inlet or outlet conditions. ASHRAE Standard 90.1 Compliant without need for additional hardware ASHRAE Standard 90.1 calls for the reset of the static pressure setpoint in VAV systems equipped with DDC controls. The AccuValve design allows the Building Automation System to provide this benefit to the owner without the requirement of any additional hardware or complexity. This is unique to the AccuValve for critical environments. Simple Layout and Installation All parts of the AccuValve are accessible from the front of the valve simplifying installation requirements. In addition, the valve can be mounted at any angle and rotated 360. Intuitive Insight Software The AVC6000 also incorporates a simple and intuitive graphical user interface which enables the user to configure the valve for their specific requirements. Accutrol s Insight software, provided free of charge, insures that the owner is not required to contact the manufacturer of the airflow control system when changes are required in the field. BACnet The integral, native BACnet MS/TP allows direct communication to the Building Automation System (BAS) where desired. AccuNet Option The optional AccuNet high-speed serial bus provides a room level network for summing multiple AccuValve airflow values into a single analog signal representing the total sum of the AccuValve exhaust airflows within the space. Bluetooth Configuration Option The AVC6000 is available with a Bluetooth configuration option, which alleviates the requirement for a USB connector when accessing the airflow valve via Accutrol s Insight graphical user interface software. Remote Airflow Monitor Option The AVC6000 is available with an optional airflow monitor that can be mounted remotely, which displays actual measured airflow. Accutrol s Insight Software Dashboard Optional Remote Airflow Monitor

Accutrol AVC6000 3 Standard Control Information Constant Volume Application Single set point Dry contact input (up to 4 discreet set points determined by 2 dry-contact inputs) BACnet MS/TP programmed set point value Airflow output to BAS is available either through Valve position is available either through hardwired analog output or BACnet MS/TP Variable Volume Applications Analog input (set point received via analog output from another controller) BACnet MS/TP programmed set point value Airflow output to BAS is available either through Valve position is available either through hardwired analog output or BACnet MS/TP Tracking Pair Configurations Lead AVC analog output is wired directly to tracking AVC analog input Lead AVC setpoint can be pre-programmed at factory as analog input, digital inputs or BACnet MS/TP Airflow output to BAS is available either through Valve position is available either through hardwired analog output or BACnet MS/TP Fume Hood Control Applications The AVC6000 incorporates a selectable Fume Hood Mode, which will configure the AVC to operate as a fume hood controller utilizing the Accutrol Fume Hood Monitor and Accutrol Sash Sensor(s) The AVC6000 allows multiple occupancy / set back mode changes through dry contact closures Configurable purge mode function Configurable alarm functions Air flow output to BAS is available either through hardwired analog output* or BACnet MS/TP * Recommended hardwired connection when utilizing airflow signal for lab airflow tracking Face velocity output to BAS is available either through Sash position or valve position output to BAS is available either through Fume hood control specific BACnet MS/TP available read/write points Additional Accutrol Product Reference Accutrol AVC Fume Hood Control System

Accutrol AVC6000 4 Operating Pressure Selector Valve Size (mm) 6" (152) 8" (203) 10" (254) 12" (305) 14" (356) 12"x18" (305x457) 12"x24" (305x610) 12"x36" (305x915) 12"x48" (305x1220) Operating Pressure Airflow Range Eng Units Minimum Maximum Design Airflow Maximum CFM 30 99 143 174 206 230 254 315 L/S 14 47 67 82 97 108 120 149 CMH 51 168 243 296 350 391 432 535 CFM 80 252 367 447 528 589 650 800 L/S 38 119 173 211 249 278 307 378 CMH 136 428 624 760 897 1000 1104 1359 CFM 120 428 606 733 860 958 1056 1300 L/S 57 202 286 346 406 452 498 614 CMH 204 727 1030 1245 1461 1627 1794 2209 CFM 180 591 840 1016 1192 1326 1461 1790 L/S 85 279 396 479 563 626 690 845 CMH 306 1004 1427 1726 2025 2253 2482 3041 CFM 250 979 1364 1624 1884 2079 2275 2750 L/S 118 462 644 766 889 981 1074 1298 CMH 425 1663 2317 2759 3201 3533 3865 4672 CFM 260 1003 1437 1761 2086 2341 2596 3200 L/S 123 473 678 831 984 1104 1225 1510 CMH 442 1704 2441 2992 3544 3977 4411 5437 CFM 350 1261 1812 2213 2614 2925 3237 4000 L/S 165 595 855 1044 1234 1381 1528 1888 CMH 595 2142 3079 3760 4441 4970 5500 6796 CFM 520 2005 2875 3523 4172 4681 5191 6400 L/S 245 946 1357 1663 1969 2209 2450 3020 CMH 883 3407 4885 5986 7088 7954 8820 10874 CFM 700 2522 3625 4426 5228 5850 6473 8000 L/S 330 1190 1711 2089 2467 2761 3055 3776 CMH 1189 4285 6159 7520 8882 9940 10998 13592 " W.C. < 0.01 0.05 0.1 0.15 0.2 0.25 0.3 0.45 Pa < 2.5 12.5 25 37.5 50 62.5 75 112.5 BEST Optimum Energy Efficiency GOOD * Minimum operating pressure when tested in accordance with ANSI/ASHRAE 130-2008 For further assistance in making your AccuValve selections, please refer to the AccuValve Selection Guide for Operating Pressure. An AccuValve selection tool for iphone, ipad and Android devices is also available to assist with AccuValve selections.

Accutrol AVC6000 5 Specifications ELECTRICAL Input Power Analog Inputs Voltage Current Resistance Digital Inputs Analog Outputs Alarm Relay Output Network Com Port 1 Network Com Port 2 Configuration Port Status Indicators Terminal Blocks 24VAC ±20% 50/60Hz 32VA max. for round, 12"x18" and 12"x24" 55VA max. for 12"x36" and 12"x48" 24VDC ±10% 18W max. for round, 12"x18" and 12"x24" 31W max. for 12"x36" and 12"x48" AI-1, AI-2 and AI-3: (software configurable) 0-10VDC range, 100K ohm impedance 0-20mA range, 500 ohm impedance 20K ohm range, 500uA Current Source AI-2 and AI-3 also include 100K ohm range, 100uA current source 12-bit resolution 2 dry-contact inputs AO-1 and AO-2: (software configurable) 0-20mA, 4-20mA, 0-10v, 2-10v, 0-5v or 1-5v 12-bit resolution V-out capable of driving 1K ohm load DPDT, NC/NO contacts, Rated load 1A @ 30VDC or 0.3A @ 125VAC Max. operating voltage = 125VAC or 60VDC Max. carry current = 1A Max. switching capacity = 37 VA, 30W EIA 485 2-wire BACnet MS/TP Full Master Node State Machine Data Rates 9600, 19200, 38400, 57600, 76800 and 115200 Software provided for setting the MAC address ¼ Unit load receiver input impedance Network bias and EOL termination not provided within the AVC AccuNet Internal LAN (optional) USB 2.0, Isolated, C type connector Optional Bluetooth LED status indicators for Power, Alarm, Analog output, BACnet communications, USB communications and AVC status 2 and 3 position vertical pluggable screw terminal blocks PERFORMANCE Accuracy ±5% of reading or 5 CFM (2 L/S; 8 CMH), whichever is greater Speed of Response < 1 second (< 2 seconds for standard actuator) Shut-off Leakage Rate Standard round valves @ 3"wc valve DP (size 06 through 14) <1.5% FS max. Round valves with blade seals (size 08 through 14) <0.5% FS max. Standard rectangular valves (size 18 through 48) <2% FS max. Rectangular valves with blade seals (size 18 through 48) <1% FS max. Max. Operating Pressure 3"wc differential pressure across valve Failure Mode Fail Last Position or Fail Open/Closed (selectable by model code) ENVIRONMENTAL Temperature Operating -20 to 165 F (-29 to 74 C) -20 to 375 F (-29 to 190 C) High Temperature 304SS AVC Storage -40 to 165 F (-40 to 74 C) Humidity 0% to 90% non-condensing MATERIALS OF CONSTRUCTION Valve Housing Shafts Aluminum (16 Gauge) 304SS (20 Gauge) 316SS (20 Gauge) 316SS Shaft Bearings Teflon Seals EPDM with aluminum valves Viton with stainless steel valves Airflow Sensors Polycarbonate plastic, UL94-VO Polycarbonate plastic, UL94-VO with Parylene Coating for 316SS AVC 303SS for High Temperature 304SS AVC Control Module Enclosure 16 Gauge aluminum Ordering Guides Please see the following page for Ordering Guides.

Accutrol AVC6000 6 AVC6000 AccuValve Ordering Guide AVC6 - - Valve Housing Material 2 = 304SS, 20 Gauge 3 = 316SS, 20 Gauge 4 = Aluminum, 16 Gauge 6 = High Temperature, 304SS, 20 Gauge Size 06 = 6" Diameter 08 = 8" Diameter 10 = 10" Diameter 12 = 12" Diameter 14 = 14" Diameter 18 = 12"h x 18"w 24 = 12"h x 24"w 36 = 12"h x 36"w 48 = 12"h x 48"w Options Blank = No Options A = AccuNet F = Flanges I = Insulation* S = Tight Shut-off** W = Wireless Bluetooth Configuration *Insulation is not available for High Temperature valves **Blade seals are standard on all 6" valves Actuator Type 03 = Fail Last Position (FLP, High Speed) 05 = Fail Open/Close (FSP, High Speed) 07 = Fail Last Position, 2-10v (Standard Speed) Your representative is: