Operator s Handbook For Compact High Voltage DC15 & DC30 POROSITY (HOLIDAY) DETECTORS

Similar documents
Compact High Voltage DC15 & DC30 POROSITY (HOLIDAY) DETECTORS

Operator s Handbook for. Compact. High Voltage P20 & P40 POROSITY (HOLIDAY) DETECTORS. Can be used in accordance with: Australian Standard AS3894.

Operator s Handbook for Compact High Voltage P20 & P40 POROSITY (HOLIDAY) DETECTORS

Holiday Detector Data Sheet / Instructions

MODEL AP/W HIGH VOLTAGE HOLIDAY DETECTOR (NEW PRODUCT RELEASE 2015)

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

Pinhole & Porosity Detection.

The D.E. Stearns Company Shreveport Louisiana U.S.A. D. E. STEARNS MODEL 14/20 REGULATED ,000 VOLT HIGH VOLTAGE HOLIDAY DETECTOR

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

OWNER S OPERATING MANUAL

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

IN & TM Series User Manual

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Time Electronics Ins-Cal. Insulation Tester Calibration System. Technical Manual

9120 EBCU Battery Charger MODELS: 9120EBCU96V 9120EBCU240V

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Rental Industry Safety Tester Safe Check 5s

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

OWNER S OPERATING MANUAL

OWNER S OPERATING MANUAL

Pinhole & Porosity. Pinhole & Porosity Detection. elcometer.com 1

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Table of Contents Title Page No.

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

IN120L / IN120LB / TM120L/TM120LB IN2400L

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Unit 2, Rivington View Business Park, Station Road, Blackrod, Bolton BL6 5BN Tel: +44(0)

EX Series User Manual

Operating Instructions for PAC800 Battery Charger

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

Abbeon Cal, Inc. Model BD-50E HIGH FREQUENCY GENERATOR OPERATING MANUAL

TBE-700. Operation, Safety and Maintenance Manual. Stainless Steel Weld Cleaning System. Ensitech Pty Ltd

Hydraulic Immediate Need Power Pack

CappController Pipette Controller. Operation Manual Version: 1.2.

OPERATING INSTRUCTIONS

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

Spy model 780 portable dc holiday detector ope rati ng instructions

OPERATING INSTRUCTION D. E. STEARNS MODEL 14/20 REGULATED ,000 VOLT HOLIDAY DETECTOR

Spy pocket Jeepmeter ope rati ng instructions

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

Pinhole & Porosity. Pinhole & Porosity Detection. elcometer.com 1

Users Manual. Phase Rotation Indicator

Spy model 780 portable dc holiday detector ope rati ng instructions

SPECTRA ENGINEERING PTY LTD. MXPS15 Series Technical Manual

Spy model 785/ 790 portable pulse holiday detector ope rati ng instructions

650mA Phase Dimmable LED Driver

Operation Manual. Pipette Aid. Concorde Liquid Handling Equipment. *This instrument is intended for laboratory use only.

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

HIGH VOLTAGE PROXIMITY DETECTOR

Information Booklet WW20072

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

Time Electronics DC Voltage Calibrator. Technical Manual

1.Safe testing IMPORTANT:

DALI 650mA LED Driver

JUMP STARTER OPERATOR S MANUAL RA1900

230VAC Power Inverter 400W Owner s Manual

OPERATING INSTRUCTION

Spy model 780 portable dc holiday detector ope rati ng instructions

THUNDERBIRD Solar Electric Fence Energisers. S20 / S20B / S40 / S40B / S79 / S150

INSTRUCTION MANUAL DM5B Fax: (503)

V4 Cordless Lamp System User Guide

Digital/Analog Megohmmeter Model 1026 USER MANUAL

Effective June 1, 2013 This guide supersedes all previous versions

ELECTRICAL. Laser Distance Measure User Guide

MICRO SWITCH INSTALLATION SHEET

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

IMPORTANT SAFETY INSTRUCTIONS

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions

Compact System NRGS 11-2 NRGS Original Installation Instructions English

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

OWNER S MANUAL Please read this manual before operating your power supply

SPRAYSHOP ANALIZER IMPORTANT : TO BE READ BEFORE USING THE HIGH VOLTAGE FUNCTION

G8 Portable Fuel Transfer Pump Owner s Manual

Matson Jump Starter Operator s Manual

Owner s Manual & Safety Instructions

Atlas ESR. User Guide. Capacitance and Equivalent Series Resistance Meter. Model ESR60 (Enhanced)

The Stannah Stairiser SX User Manual

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

1000mA - 650mA Phase Dimmable LED Driver

OPERATION INSTRUCTIONS

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

DC to DC Step Up Converter Model: VTC305

ELECTRICAL. Moisture Meter User Guide

This instrument is manufactured in the United Kingdom. The company reserves the right to change the specification or design without prior notice.

FEATURES. Power Status and Charge Indicator: A red LED indicates the battery is charging and a green LED indicates the battery is fully charged.

Refinery Supply Company, Inc.

TIF8800X. Combustible Gas Detector. an spx brand. Owner s Manual. 99 Washington Street Melrose, MA Phone Toll Free

CONTENTS. Introduction. Thank you for purchasing the AlcoSense Precision+ breathalyser.

Hydraulic PTO Flow Device

Transcription:

Operator s Handbook For Compact High Voltage DC15 & DC30 POROSITY (HOLIDAY) DETECTORS Can be used in accordance with: Australian Standard AS3894.1 ASTM G62, ASTM D5162, ASTM D4787, NACE SP0274, NACE SP0490, NACE SP0188, ANSI/AWWA C213, ANSI/AWWA C214, ISO 2746 CE Marked PCWI Compact Detectors comply with the requirements of EMC Directives 89/336/EEC EMC and its amending directives.

POROSITY DETECTOR ACCURACY: +5% of reading or + 50V below 1kV Note: at the time PCWI tested the Porosity Detector at the reference temperature & humidity). Refer to the PCWI Manufacturer s Calibration Certificate provided with the Porosity Detector. Range: 0kV to 30kV Recertification available. 1

WARNING This Equipment generates a high voltage and should be used with care. Please consult these operating instructions before use. CONTENTS 1.0 Safety Precautions 4 2.0 Operation 5-6 3.0 Specifications 6 4.0 Control Panel Layout 7 5.0 Voltage Recommendations 8-9 6.0 Troubleshooting 10-11 7.0 Optional Accessories 12-13 8.0 PCWI LiFePO4 Battery 14 9.0 Warranty 15 10.0 Service & Maintenance 16 2

INTRODUCTION Thank you for choosing the PCWI Compact for pre-installation and post installation corrosion detection. PCWI have designed this instrument with care, to provide ongoing corrosion detection efficiency under a wide variety of coating application conditions and to ascertain Porosity for the many protective coatings currently in use. Under reasonable care in operation, the unit will provide many years of trouble free detection. To support the unit, PCWI maintain a comprehensive range of Electrodes (probes) - extending the versatility of the Compact from large to small and from accessible to inaccessible surfaces. PCWI, in a continuing desire to achieve the maximum in corrosion detection competence, welcomes user enquiries and recommendations. Yours sincerely Paul Van Gaal 3

1.0 SAFETY PRECAUTIONS: All hand-held high voltage test equipment should be operated by responsible, trained and authorised personnel. The unit must be earthed to both the item under test and to ground. CAUTION The Detector output can be up to 35,000 volts. Should the operator accidentally make contact with the test electrode, they may experience a mild shock or zap, and in order to avoid this possibility, the wearing of rubber gloves is recommended. Furthermore, the operator should enjoy good health and not suffer from a cardiac condition. If the operator has a pacemaker, then they should not use this equipment. This equipment should only be used for the purpose for which it was designed, ie: checking the porosity, or electrical breakdown, of dielectric or insulating materials. It is also recommended that testing should be carried out well clear of personnel not involved in the testing procedure, or in such a position whereby the surprise of receiving an electric shock could cause a related accident, if for example, tests being carried out close to moving or rotating machinery, or in such an unstable position that the operator could fall and injure themselves. It is recommended that the operator should have an assistant, to ensure that unauthorised personnel are kept well clear of the testing area, and generally assist when necessary with the testing procedure. It is also recommended that the Detector not be operated within close proximity of sensitive electronic apparatus, such as computer equipment. DANGER Do not use the test equipment in any combustible or flammable atmosphere, as a test voltage can cause an arc or spark to be generated and an explosion could result. Always consult the plant or safety officer before carrying out a test procedure. When testing tank internals, be certain the tank does not contain solvents remaining from the painting procedure. 4

Coating Thickness Range Applied coats should be cured, thickness tested, visually inspected and accepted before high voltage porosity testing is carried out. Coating thickness should be above 150µm; coatings below this thickness should be tested with a wet sponge unit. 2.0 OPERATION Connect the probe and earth leads to the unit. Connect the earth clamp to the metallic substrate of the item to be tested substrate should be earthed to ground. Select the probe best suited for the test and attach to the probe handle. Fit the Fuse (if not already fitted). Turn the unit on. Check the batteries to ensure that they are charged. Turn the voltage control clockwise to the required test voltage. Note: If the neon is in place allow an additional 200v. Place the probe near the metal substrate. A spark should occur (if not re-check all leads and connections). Place the probe on the surface to be tested. Re-check the output adjust if necessary. Turn alarm sensitivity until the alarm is just off. Place the probe on the coated surface and move at approximately one metre per four seconds. A fault is indicated by: A spark at the probe this can usually be seen and heard. A light flashes on the front panel of the unit. An audible sound buzzer is mounted inside the unit. Digital test voltage drops drastically. The neon in the probe flashes. Note: A definite flaw should be made in the coating and located with the designated test voltage, therefore proving that the unit is locating the type of fault you wish to find. Probes must be kept in full contact with the surface, gaps in or between the probe and the coating may result in flaws going undetected. Wire brushes, rubber and coil spring probes should all be kept in good condition. Probes other than fine wire brushes may require higher voltages. Wet and contaminated coatings should not be tested until dry and clean (see also troubleshooting pages). 5

Earthing Where the item to be tested is not earthed to ground, a ground spike must be attached. The unit should always be switched off before removing and repositioning the earth lead. After the earth is repositioned, the probe should always be flashed on the substrate to prove a good contact has been made. Leads Carbon cored 22kΩ High Voltage leads must be used. Use of copper cored leads will void warranty. 3.0 SPECIFICATIONS Weight: 2.2kg Display: LCD 3¾ digits with battery indicator Voltage 0 to: DC15: 15kv DC30: 30kv Resolution: 10v 10v Short circuit: Test current less than 0.5mA Power supply: 3Ah Slide-off Recharge Time: 400mA for 10hrs. Battery Test: When Porosity (Holiday) Detector is switched on, the result is displayed on the LCD. Dimensions: 260 x 160 x 70mm Alarms: Audible with sensitivity adjustment. Visual front panel light. Neon in probe 360 visibility Probe lead: 2m carbon-cored high-voltage silicon-rubber. Earth lead: 7m silicon-rubber with a clamp fitted to one end. Probes: 250mm Flat Brass Wire brush, trim length of 50mm Carry Case: 150 x 370 x 440mm Optional coils & brushes available: See accessories pages STORAGE: The Detector should be stored in a dry place. Leads should not be wound tightly. Battery should be fully charged. 6

4.0 CONTROL PANEL LAYOUT 1 2 3 4 6 5 7 1 LCD display (including battery condition indicator) 2 Voltage control (10 turn) 3 Visual alarm indicates when fault is found 4 On switch 5 Off/test switch 6 Sensitivity control for the alarm 7 Audible alarm when fault is found 8 High Voltage probe connector 9 Fuse (1.6A slow blow) 5 x 20mm 10 Earth connection point 11 Slide-off power pack 12 Earphone jack (opposite side) 12 8 9 10 11 Probe Handle Diagram Side View Spring Probe Handle Washer Screw Fitting Neon Lock Nut Screw Neon Holder End Cap Carbon Cored Lead O Rings 7

5.0 VOLTAGE RECOMMENDATIONS International Standards NACE SP0188 derived table Table 1. below is derived from NACE standards and should be used as a guide only. New protective Coatings on Conductive Substrates Table 1 Suggested for High Voltage Spark Testing Total Dry Film Thickness Suggested Inspection (µm) (mil) (V) 200 to 300 8 to 11 1,500 300 to 400 12 to 15 2,000 400 to 500 16 to 20 2,500 500 to 1,000 21 to 40 3,000 1,000 to 1,400 41 to 55 4,000 1,400 to 2,000 56 to 80 6,000 2,000 to 3,200 81 to 125 10,000 3,200 to 4,700 126 to 185 15,000 The above table should be taken as a GUIDE only. It is recommended that the whole of this standard be used. ALLOW AN ADDITIONAL 200 VOLTS IF THE NEON IN THE PROBE HANDLE IS IN USE 8

International Standards NACE SP0490 and SP0274 derived tables Tables 2 & 3 below are derived from NACE standards and should be used as a guide only. Thin Film Pipeline Coatings (FBE) Table 2 kv Values from NACE SP0490 General Pipeline Coatings Table 3 kv Values from NACE SP0274 mm kilovolts mm kilovolts 0.250 1.650 0.280 1.750 0.300 1.800 0.330 1.900 0.360 1.950 0.380 2.050 0.410 2.100 0.510 2.350 0.640 2.650 0.760 2.900 0.51 6 0.79 7 1.6 10 2.4 12 3.2 14 4.0 16 4.8 17 13 28 16 31 19 34 The above tables should be taken as a GUIDE only. It is recommended that the whole of this standard be used. ALLOW AN ADDITIONAL 200 VOLTS IF THE NEON IN THE PROBE HANDLE IS IN USE 9

6.0 TROUBLESHOOTING In order to ensure that your Compact Porosity Detector is operating to specification, the Detector handle and lead should be checked prior to use. Use the following procedure: Unscrew the neon holder from the handle. Using a multimeter, complete the circuit and check the resistance at both the handle 1 and the high voltage plug 2. If resistance is outside the 1 meg ohm range, or is open circuit: (a) Check 1 and 2 for either poor connection or damage; (b) Check for break or damage to the HV lead 3. Replace/rectify connection and leads and then re-test. Neon Holder Below 1MΩ HV Lead 10

Symptom Cause Solution No Display Flat battery Recharge battery Display shows -1 No Power - fuse not fitted Voltage higher than display capacity Display erratically shows -1 Display drops to -1 when fault found Fit fuse Decrease voltage Normal operation Display voltage drops during test Slightly conductive, damp or salty surface Coating may not be fully cured Wash and clean the surface Allow coating to cure Probe surface area too large Use smaller probe, or increase voltage Blackening Display Poor Earthing Make positive earth connections Alarm sounds continuously during test No alarm on fault No spark at probe tip Slightly conductive, damp or salty surface Coating may not be fully cured Probe moved too fast Probe surface area too great Sensitivity adjusted too low a setting Voltage set too low Neon in handle damaged Damaged leads Poor connections Flat battery Wash and clean the surface Allow coating to cure Move probe 1 metre every 4 seconds Use smaller probe Increase sensitivity Increase voltage Replace neon (or use a metal conductor piece) Repair or replace leads Clean and reconnect Recharge battery Probe voltage lower than display voltage 11 Neon in handle can use up to 200 volts Damaged HV lead Poor earth connection Turn up voltage control to compensate for neon Replace lead Check all connections

7.0 OPTIONAL DETECTOR ACCESSORIES PCWI High Voltage DC Crest Meter for verifying DC Detector output voltage. DC Crest Meter includes Calibration Certificate. Brushes & Coils PCWI manufacture brushes and coils to suit your needs. 50mm (2in) to 600mm (24in) wide flat brushes. 25mm (1in) to 500mm (20in) Spiral wound and Disc Internal circular pipeline brushes. 25mm (1in) to 500mm (20in) External circular pipeline brushes. 12

OPTIONAL DETECTOR ACCESSORIES 60mm, 125mm, 200mm, 450mm connectors for flat or external pipeline brushes. Coil Joiners Fan Brushes Additional Accessories Spare slip-out power packs. 7m Earth lead with clamp. 10m trailing Earth lead (1m plastic encased). Spare neon light holders and neon's See www.pcwi.com.au for more details. 13

8.0 PCWI LiFePO4 Battery Use the PCWI LiFePO4 Charger to charge LiFePO4 battery. 1) The charger plugs into the side of the battery 2) LED on charger lights up Red when Charging 3) LED on Charger lights up green when battery is charged. 4) If the battery is in the device when the charger is connected the devicewill turn off. 5) You cannot use the device when the charger is connected to the battery. 6) Battery is shipped with less than 25% charge in accordance with IATA shipping regulations. 7) Charge Time is approx 4 Hours Important Note: Battery terminal protector for shipping purposes only. 14

9.0 WARRANTY Subject to the warranty conditions below this PCWI Instrument is warranted by PCWI International Pty Ltd to be free from defects arising from faulty design, material, or workmanship for a period of 12 months from the date of original purchase by the end user or a maximum period of 15 months from dispatch to authorised distributors. Probes and leads are warranted for 3 months. They are consumable items, and subject to wear and deterioration during use. The life of these parts can be much extended by keeping them in a dry clean condition, and storing them in suitable protective containers. During use, avoid scrubbing the probe along the surface of the work-piece. WARRANTY CONDITIONS During the warranty period listed above PCWI or it s authorised service representative will make good any defects covered by this warranty. PCWI or it s authorised service representative will decide if there are any defects in design, material or workmanship. This warranty only applies provided the instrument has been used in accordance with the manufacturers operating handbook recommendations. This warranty does not cover damage, malfunction or failure resulting from misuse, neglect, abuse or used for a purpose for which it was not designed and no repairs, alterations or modifications have been attempted by other than PCWI on an authorised service. This warranty applies only to the original user buyer. This warranty does not cover any service that is needed after an accident, alterations, misuse, fire or floods. This warranty is the only one given by PCWI and no one has the authority to change, or add to, the obligations and liabilities listed in it. This warranty does not cover batteries, probe handle brushes (electrodes) and leads which are subject to wear. During the warranty period PCWI or its authorised service representative will bear the transportation cost of the return of instrument/s repaired under warranty back to the users premises within the country of purchase. HOW TO MAKE A WARRANTY CLAIM Defective goods must be returned to PCWI or an authorised service representative at the Purchaser s expense. The goods must be accompanied by the Purchaser s written order describing the defect and authorising PCWI or its authorised service representative to invoice the Purchaser for any charges not covered by the warranty. The purchasers order must also include the model and serial numbers of the instrument and address of the distributor and date of purchase. Upon receipt at the service point the instrument will be examined to determine the nature and cause of the defect. If the defect is covered by the warranty, a repair will be effected at PCWI s or authorised service representative expense. If the defect is not covered by the warranty, PCWI or authorised service representative will quote the Purchaser for a replacement or repair, and will not proceed until written acceptance of the quotation is received. 15

10.0 SERVICE AND MAINTENANCE AUTHORISED SERVICE REPRESENTATIVE To enable speedy return to service whether under warranty or otherwise, PCWI have appointed your distributor as a service centre and have provided all relevant information and recommended parts to be carried to assist distributor s technical staff carry out this essential part of the PCWI customer service. CARE AND MAINTENANCE This equipment is protected against hostile environments and is designed for prolonged use in the field without any special maintenance, other than routine battery recharging. However, the equipment is not totally sealed and appropriate precautions should be taken. Remember, it is a precision electronic instrument and should be treated as such. There are no internal user controls. The equipment should only be operated by qualified personnel. Some organic materials may attack plastic parts and cause early degradation. Contact with such materials should be avoided. Do not operate damaged equipment. Where the power supply is derived from internally mounted rechargeable cells and disassembly of the unit is necessary to access those batteries, this action would void all warranty. SERVICE REPAIRS AND MAINTENANCE Repairs not covered by the warranty or carried out after the warranty period, will be charged at the current hourly or set service rate, plus the cost of materials. Goods for repair must be sent at the Purchaser s expense, and be accompanied by the Purchaser s written order describing the defect and authorising PCWI to invoice the purchaser for labour, materials and return delivery cost. No service or repair will be undertaken until a written order is received. BEFORE YOU CALL FOR SERVICE Read the section on troubleshooting in this handbook and check the symptom, cause and solution before you call for service. AUTHORISED SERVICE AGENT: 16

Notes:

Notes:

PCWI OFFERS Strong technical support In-house development and manufacturing enables us to provide strong technical support and a quick response to enquiries and orders. Market and product knowledge We understand technical specifications demanded by industry and recognise customer requirements are specific in relation to testing and measuring instruments. Calibration laboratory PCWI s in-house laboratory supports testing for a range of instruments operating in accordance with ISO/IEC 17025. All certification is Traceable to National & International Standards of Measurement. Quality systems certified to ISO9001 PCWI s Quality Management System is certified to ISO9001 and audited by SAI Global. Warranties and after sales service PCWI provides 12 months warranty for its Detectors with detailed operator instruction handbooks and after sales service. An extension of this PCWI service is provided by your local distributor. Office: 13 Alhambra Avenue CARDIFF NSW 2285 Newcastle AUSTRALIA Postal: PO Box 900 HUTER REGION MC NSW 2310 Phone: (02) 4954 3900 Intl: +61 2 4954 3900 Fax: (02) 4954 3999 Email: sales@pcwi.com.au Web: www.pcwi.com.au P:\Instruction Manuals\Manual - PCWI\DC15 & DC30 (13 July 2017).pdf 2003 PCWI Pty Ltd