POWER FACTOR CORRECTION USING SHUNT COMPENSATION

Similar documents
A Transient Free Novel Control Technique for Reactive Power Compensation using Thyristor Switched Capacitor

International Journal of Advance Engineering and Research Development. Automatic Power Factor Correction in EHV System

Paper ID: EE19 SIMULATION OF REAL AND REACTIVE POWER FLOW ASSESSMENT WITH FACTS CONNECTED TO A SINGLE TRANSMISSION LINE

Reactive Power Management Using TSC-TCR

Implementation of FC-TCR for Reactive Power Control

Power Quality Improvement Using Statcom in Ieee 30 Bus System

International Journal of Emerging Technology and Innovative Engineering Volume 2, Issue 4, April 2016 (ISSN: )

POWER FACTOR CORRECTION USING SVC TECHNIQUE

Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System

Modelling and Analysis of Thyristor Controlled Series Capacitor using Matlab/Simulink

Concepts And Application Of Flexible Alternating Current Transmission System (FACTS) In Electric Power Network

Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG)

TRANSMISSION LOSS MINIMIZATION USING ADVANCED UNIFIED POWER FLOW CONTROLLER (UPFC)

Microcontroller Based Power Factor Correction Using SCR

PQC - STATCON The ultra fast Power Quality Compensator

A Review on Reactive Power Compensation Technologies

Overview of Flexible AC Transmission Systems

Performance Analysis of Transmission Line system under Unsymmetrical Faults with UPFC

PPHVC Power Quality Solutions. ABB PQC-STATCON Benefits and advantages

IJRASET 2013: All Rights are Reserved

Induction Generator: Excitation & Voltage Regulation

Recent Trends in Real and Reactive Power flow Control with SVC and STATCOM Controller for transmission line

International Journal of Advance Research in Engineering, Science & Technology

PQC-STATCON. PPHVC-Power Quality Solutions. Instantaneous and stepless power quality compensation for dynamic reactive power and unbalanced loads

ELG4125: Flexible AC Transmission Systems (FACTS)

Dynamic Reactive Power Control. By V. R. Kanetkar Full Time Consultant Technical Services at Veretiv Energy Private Limited Thane (West)

Modeling and Simulation of TSR-based SVC on Voltage Regulation for Three-Bus System

Reactive Power Compensation by Innovative TSC-TCR type SVC Controller

Exercise 6. Three-Phase AC Power Control EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Introduction to three-phase ac power control

INSTALLATION OF CAPACITOR BANK IN 132/11 KV SUBSTATION FOR PARING DOWN OF LOAD CURRENT

POWER FACTOR CORRECTION OF FAST DYNAMICS INDUSTRIAL LOADS

Performance of FACTS Devices for Power System Stability

Chapter 3.1: Electrical System

Okelola, M. O. Department of Electronic & Electrical Engineering, Ladoke Akintola University of Technology, P.M.B. 4000, Ogbomoso, Nigeria

Measurement of induction motor characteristics

COMPARISON OF STATCOM AND TCSC ON VOLTAGE STABILITY USING MLP INDEX

Analysis of Grid Connected Solar Farm in ETAP Software

Voltage Sag Mitigation in IEEE 6 Bus System by using STATCOM and UPFC

ABB n.v Power Quality in LV installations

A SIMPLE CONTROL TECHNIQUE FOR UNIFIED POWER FLOW CONTROLLER (UPFC)

Statcom Operation for Wind Power Generator with Improved Transient Stability

Maintaining Voltage Stability in Power System using FACTS Devices

American Journal of Science, Engineering and Technology

Tiruchengode, Tamil Nadu, India

Power Quality and Energy Management

Systematic Survey for Role of Reactive Power Compensating Devices in Power System

IMPROVING VOLTAGE PROFILE OF A GRID, CONNECTED TO WIND FARM USING STATIC VAR COMPENSATOR

Implementation SVC and TCSC to Improvement the Efficacy of Diyala Electric Network (132 kv).

International Journal Of Global Innovations -Vol.2, Issue.I Paper Id: SP-V2-I1-048 ISSN Online:

Integration of Large Wind Farms into Electric Grids

Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC

Power Quality Enhancement Using Thyristor controlled reactor and Thyristor switch capacitor

CHAPTER 6 POWER QUALITY IMPROVEMENT OF SCIG IN WIND FARM USING STATCOM WITH SUPERCAPACITOR

POWER FACTOR REBATE-BOLD DECISION FROM REGULATOR

6545(Print), ISSN (Online) Volume 4, Issue 2, March April (2013), IAEME & TECHNOLOGY (IJEET)

Power Quality Luis Vargas Research Engineer 9/18/2008

THE METHODS OF REACTIVE POWER COMPENSATION IN THE 25 kv, 50 Hz CONTACT NETWORK

Working Principle of Power Saver as per Manufacture:

Enhancement of Power System Stability Using Thyristor Controlled Series Compensator (TCSC)

Power Quality and Power Interruption Enhancement by Universal Power Quality Conditioning System with Storage Device

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October ISSN

CTU 02. Thyristor switching module for fast PF compensation. User manual

VOLTAGE STABILITY IMPROVEMENT IN POWER SYSTEM BY USING STATCOM

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

DRAFT. Guidelines on Power quality & safety issues in usage of roof-top solar pv system CENTRAL ELECTRICITY AUTHORITY

Technical News. Power Factor Correction. What technology is best for you? Specialists in electrical and automation products, systems and solutions

DYNAMIC BEHAVIOUR OF SINGLE-PHASE INDUCTION GENERATORS DURING DISCONNECTION AND RECONNECTION TO THE GRID

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

A New Device to Measure Instantaneous Swept Volume of Reciprocating Machines/Compressors

International Conference on Advances in Energy and Environmental Science (ICAEES 2015)

1 Low-voltage Power-factor Correction capacitors KNK APPLICATION DESIGN

Alternator as a voltage Generating source and its response to the leading power factor loads

Simulation of real and reactive power flow Assessment with UPFC connected to a Single/double transmission line

Performance of DC Motor Supplied From Single Phase AC-DC Rectifier

Improving Voltage of Grid Connected to Wind Farm using Static VAR Compensator

Fuzzy Based Unified Power Flow Controller to Control Reactive Power and Voltage for a Utility System in India

Electric Power System Under-Voltage Load Shedding Protection Can Become a Trap

APPLICATION OF STATCOM FOR STABILITY ENHANCEMENT OF FSIG BASED GRID CONNECTED WIND FARM

Supercapacitor Based Power Conditioning System for Power Quality Improvement in Industries

DYNACOMP. The top-class reactive power compensator

POSSIBILITIES OF POWER FLOWS CONTROL

Advance Electronic Load Controller for Micro Hydro Power Plant

A Comprehensive Study on Speed Control of DC Motor with Field and Armature Control R.Soundara Rajan Dy. General Manager, Bharat Dynamics Limited

SPRING (FINAL) TERM REPORT ENTITLED: THYRISTORS CONTROLLED CONVERTER FOR LINE COMPENSATION

EPRLAB FAQ v1.0 Page 1 / 8 Copyright EPRLAB December 2015

Modelling and Simulation of DFIG based wind energy system

kvah Billing - Frequently Asked Questions (FAQs)

Using MATLAB/ Simulink in the designing of Undergraduate Electric Machinery Courses

Rotor Side Speed Control Methods Using MATLAB/Simulink for Wound Induction Motor

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

Eskisehir Light Train- Correcting Capacitive

Dynamic Control of Grid Assets

Impact of Plug-in Electric Vehicles on the Supply Grid

INTRODUCTION. I.1 - Historical review.

Steady State Voltage Stability Enhancement Using Shunt and Series FACTS Devices

Power Factor Correction

Reactive Power Compensation at Load Side Using Electric Spring

DESIGN AND ANALYSIS OF CONVERTER FED BRUSHLESS DC (BLDC) MOTOR

Transcription:

International Journal of Electrical and Electronics Engineering (IJEEE) ISSN(P): 2278-9944; ISSN(E): 2278-9952 Vol. 3, Issue 3, May 2014, 39-48 IASET POWER FACTOR CORRECTION USING SHUNT COMPENSATION DHRUVI CHOPRA, IS HA WALIA, HARS HITA S ETHI & ELISABETH HELWIG Student, School of Electrical Engineering, VIT University, Vellore, Tamil Nadu, India ABSTRACT This paper discusses the Static VAR Compensation (SVC) method as an effective solution for power factor improvement. The need for power factor correction arises to regulate the system voltage and reactive power flow in an electrical system. A MATLAB/GUI model is developed to determine the amount of Var and capacitance required to compensate the power factor and voltage variations occurring under different loading conditions in an Electrical Mach ines Laboratory. Also to demonstrate the power factor correction using shunt compensation, a MATLAB/SIMULINK model is developed. The various forms of shunt compensation methods like fixed compensation and SVC are implemented and the results are analyzed for the systems without and with shunt compensation. KEYWORDS: Fixed Capacitors, Power Factor, Reactive Power Compensation, SVC, Thyristor Switched Capacitor, Thyristor Controlled Reactor INTRODUCTION Maintaining the stable voltage profile and lossless power system with a high rate of availability and reliability is the most important objective of an electrical network. The interaction between supplier and consumer is the interface where the definition of power quality does not only affect the determination o f the electrical equipment but also the economical billing scheme due to the load demand. The occurrence of additional reactive load demand results in poor power factor. In power systems, addition of load leads to an increase in the load current and consequently higher voltage drop and losses along the transmission and distribution network. This reduces the overall performance and efficiency of the network. Hence in case of higher reactive load demand and to transfer the more current, an equivalent design o f higher power rating of all current carrying components in the system is to be redesigned. Additionally energy suppliers charge their consumers when his power factor falls below a certain value since the billing scheme is defined for the consumption of active as well as reactive power. Due to all these effects fast load compensation methods are needed. Load compensation can be carried out in different ways depending on the considered aim of improvement. The methods which are used are: reactive power compensation, unbalanced load compensation and minimization of harmonic distortion. The following study shows the power factor improvement and the stabilization of the supply voltage of a supply network with an increased number of loads over the time by two different reactive power compensation methods. Firstly the behavior of a fixed mechanically switched capacitor bank is observed and secondly thyristor switched capacitors (TSC) and thyristor controlled reactors (TCR) are modeled for static VAr compensation (SVC). UNDERSTANDING POWER FACTOR The ratio of the real power used by the load to the apparent power drawn by it from the supply is defined as the power factor of the electrical system. www.iaset.us editor@iaset.us

40 Dhruvi Chopra, Isha Walia, Harshita Sethi & Elisabeth Helwig (1) The inclusion of heavy inductive loads leads to lagging power factor whereas under light loads causes leading power factor for long transmission line networks [1][2]. Most of the bulk load consumers in a power system use inductive loads like induction furnaces, welding, ovens, lathe machines, drilling machines in industries etc. When such lagging power factor loads are introduced in a circuit, the voltage at the receiving end tends to decrease due to an increase in the load current. This results in an increase in the reactive power demand and losses in the circuit. A reduced power factor is undesirable because it results in poor reliability, safety problems, increases system capacity and higher energy costs. CAPACITANCE CALCULATION USING GUI MODEL In a single phase or a three phase system, the capacitance required for compensation is calculated using the following formulas [3]: The required capacitive kvar is given by- (2) The Capacitance to be inserted in each phase for compensation is given by- (3) Where, Cos ϕ 1 is the existing power factor Cosϕ 2 is the desired power factor. P is in kilowatts V is the phase to ground voltage., f is supply frequency The calculation of the required reactive power and the amount of additional capacitance has been carried out by a designed graphic user interface in MATLAB. The GUI has 3 panels. Within the first panel Selection the user can select the type of the power system and the given input data. In the second panel Input Data the user can edit the data numbers of his former input selection as well as for the mandatory parameters which have been given a default value. After pressing the Compute -button the output data: Required reactive power Additional capacitance Figure 1 shows the flowchart for GUI using which per phase requirement of capacitance for various power factors is calculated. Table 1 shows various values of capacitance in µf required for compensating various power factors which are observed from our institute electrical machines laboratory [4]. Impact Factor (JCC): 2.4886 Index Copernicus Value (ICV): 3.0

Power Factor Correction Using Shunt Compensation 41 Table 1: Capacitance Needed in µf for Compensation DES IGN AND EVALUATION In order to analyze the improvement in power factor, data is collected from Electrical Machines Laboratory. Two induction motors of 3 Phase, 415 V, 2 kw are switched ON successively to observe the dip in power factor and the required compensation is provided by Fixed Capacitors and SVC. The single line diagram of the laboratory is shown in Figure 2. Uncompensated S ystem Two loads having a rating of 3 Phase, 415 V, 2 kw are connected to the supply via circuit breaker. The loads are introduced successively. For this scenario, the power factor, reactive power and other parameters are noted. The power factor of the system is observed to be 0.55. This value is very less for practical cases and increases losses in the system. www.iaset.us editor@iaset.us

42 Dhruvi Chopra, Isha Walia, Harshita Sethi & Elisabeth Helwig Figure 1: Flowchart Representing the Calculations Done in GUI Impact Factor (JCC): 2.4886 Index Copernicus Value (ICV): 3.0

Power Factor Correction Using Shunt Compensation 43 Figure 2: Single Line Diagram of Laboratory under Study Hence there is a need to improve the power factor. The waveforms of active power, reactive power, power factor and current for the uncompensated system are shown in Figure 3. The figure depicts that with the increasing load, the reactive power, and current demand of the load also increase. Table 2: Inductive Load S pecifications Specification Rating Rated Power (VA) 3605 Real Power (W) 2000 Reactive Power (kvar) 3000 RMS Current (A) 5.02 Phase Angle 56.63 Power factor 0.55 Figure 3: From Top to Bottom - Voltage, Load Current, Active Power, Reactive Power, Power Factor of Phase a www.iaset.us editor@iaset.us

44 Dhruvi Chopra, Isha Walia, Harshita Sethi & Elisabeth Helwig Compensated System Using Fixed Capacitors It is observed that when both the loads are on, the reactive power demand is approximately 6 kvar. To supply this reactive power, two capacitor banks are connected in parallel via externally monitored circuit breakers for each phase. A feedback loop is designed to automatically turn on the capacitor banks whenever there is an increase in the load current and a reduction in the power factor, as shown in Figure 4. The rms value of the load current and power factor are compared with a reference value using a comparator. If the current entering the comparator exceeds the reference current, and the power factor is less than 1, the respective capacitor bank turns on. Following this rule, when load 1 is turned on, capacitor bank 1 becomes active to provide compensation. Further as load 2 turns on, capacitor bank 2 also turns on along with 1 to provide compensate the dip in the power factor. Therefore, when both the loads are switched in the circuit, all the capacitor banks are active thus providing full compensation to the system and correcting the power factor to 1. The capacitance required for different combinations of loads and the associated reactive power is shown in the table 3. Figure 4 shows the block diagram of the system under study with fixed capacitors and the related waveforms are shown in Figure 5. Figure 4: Block Diagram of Compensated System with Fixed Capacitors As the loads and capacitance banks are switched on, the variation of power factor is observed, as shown in Figure 5. Also it is noted that when the unity power factor is obtained the reactive power falls to approximately zero, whereas there is no significant change in the active power due to the use of the compen sation technique. Hence the inductive reactive power of the load is completely balanced by the capacitive reactive power of system. Also the current demand is reduced which further reduces the losses, thus enhancing the system efficiency. Table 3: Capacitance Required after S witching on of Each Load for Compensation Load PF Q (Var) Reqd. Capacitance (µf) First Load 0.55 3000 55.4 Both Loads 0.80 3012 55.4 Impact Factor (JCC): 2.4886 Index Copernicus Value (ICV): 3.0

Power Factor Correction Using Shunt Compensation 45 Figure 5: From Top to Bottom- Voltage, Active Power, Reactive Power, Power Factor of Phase a Compensated System Using SVC Static Var compensator consists of two compensator - Thyristor Switched Capacitor (TSC) and Thyristor Controlled Reactor (TCR). A TSC s can be either switched on or off whereas TCR s can be smoothly controlled by varying firing angles of the thyristor pair. The value of TSC s capacitor is chosen such that it generates leading Vars to compensate the effect of the inductive load and to attain unity power factor (using developed GUI model). If due to the TSC any overcompensation is caused then it is corrected by the TCR. TCR with the help of bidirectional thyristors in jects the inductive power in the system in case of overcompensation. To avoid heavy oscillatory currents during turning on of TSC, the firing angle of the thyristors should be carefully chosen. Therefore, TSC should be switched on/off when the applied voltage is at its peak. Also it is required that the capacitor should be pre-charged to the peak value of the applied voltage before switching [5]. In case of TCR, the firing angle is variable depending upon the overcompensation occurring due to TSC. For the demonstration of reactive power control using SVC, same two reactive loads of 3 Phase 415 V, 2 kw, 0.55 power factor lagging are taken for study. In 3 Phase, two TSCs per phase are star connected for each load. The anti-parallel thyristors are fired at the peak of the applied voltage. For phase a the thyristors are fired at Π/2 and 3Π/2. Similarly for phases b and c the firing angle for the thyristor pair is set at (7Π/6, 13Π/6) and (11Π/6, 17Π/6) respectively. Simultaneously the load current and power factor are monitored, which provide a feedback to the thyristors of TSC. So by comparing these values, with the reference value the thyristors of TSC are fired, keeping in mind the firing should take place at the peak of input voltage. This process is shown by the block diagram in Figure 6. With proper firing of thyristors and a proper selection of capacitors (refer table 3), the power factor is corrected from 0.55 to 1. For TCR firing, the output reactive power is monitored. When the capacitive reactive power starts increasing, i.e. in case of overcompensation, the thyristors of the TCR are turned on by getting a signal from reactive power monitor. Therefore capacitive reactive power is balanced [6]. The waveform of active and reactive power and power factor is given in Figure 7. It is evident that SVC is effective in reducing the losses by reducing the reactive power and current. www.iaset.us editor@iaset.us

46 Dhruvi Chopra, Isha Walia, Harshita Sethi & Elisabeth Helwig RESULTS AND OBSERVATIONS It is observed that both the methods successfully correct the power factor from 0.55 to 1 and reduce the net reactive power demand to zero by injecting leading vars in the system. It is also observed that the current comes down to a small value, hence reducing the losses in the system. The results of the compensation obtained through fixed capacitors and TSC-TCR are given in Table 4 below. Figure 6: Block Diagram of SVC with Feedback Figure 7: From Top to Bottom- Voltage, Active Power, Reactive Power, Power Factor Impact Factor (JCC): 2.4886 Index Copernicus Value (ICV): 3.0

Power Factor Correction Using Shunt Compensation 47 Table 4: Comparison of Parameters before and after Compensation CONCLUSIONS The study shows the theoretical principles of power factor improvement and stabilizing of supply voltage by implementing reactive load compensation in a model of 3 phase power supply system. The effects of a fixed capacitor-bank and an SVC have been analyzed regarding their benefits to an uncompensated power supply system. The input data of the conducted simulation model had been taken from an experimental measurement in the Electrical Machines Laboratory of VIT University Vellore (India). The conducted study shows that for an uncompensated power supply system the supply vo ltage decreases with an increase of load. Due to the rise of reactive power demand the power factor decreases with the load. By implementing a fixed capacitor bank which had been attuned to the arising load, a successful compensation was reached with a power factor of unity. The prediction of necessary capacitance for the compensation is very important. For this purpose, a MATLAB GUI model is prepared to calculate the capacitance required for compensation. In case of widely fluctuating loads a fixed capacitor bank will lead to either overcompensation or under-compensation. Therefore a variable VAR compensation is needed. Nowadays thyristor switched capacitances are combined with thyristor controlled reactor banks to minimize the effect of harmonic distortion by acting as a filter system. For this purpose, a model of TSC-TCR was prepared which allowed full compensation of the system leading to a power factor of unity. Moreover due to the development of self-commutated power electronic devices various other compensation methods have been developed in order to achieve a more accurate compensation with the inherent ability of providing leading and lagging reactive power. ACKNOWLEDGEMENTS The authors thank S. Meikandasivam, Associate Professor, D. Vijayakumar, Asso ciate Professor and S. Umashankar, Assistant Professor, School of Electrical Engineering, VIT University, Vellore for their constant guidance and support without which this work would have left incomplete. REFERENCES 1. Electro mechanica s report on Power Factor correction. 2. Pamela Ackerman, Semester report on Power factor correction for power systems. www.iaset.us editor@iaset.us

48 Dhruvi Chopra, Isha Walia, Harshita Sethi & Elisabeth Helwig 3. Taufik and Bryan Paet, A s mall scale Static Var Compensator for Laboratory Experiment. 4. Elspec Ltd., Elspec Power Quality Solutions document. 5. Umashankar s, Dr. Ray K K, Dr Kothari DP, Evaluation of dynamic reactive power compensation using static VAr compensator. 6. Pravin Chopade, Marwan Bikdash, IbraheemKateeb, Ajit D. Kelkar, 7. Reactive power management and voltage control of large transmission system using SVC. Impact Factor (JCC): 2.4886 Index Copernicus Value (ICV): 3.0