Instructions for use and installation Cooker Hood

Similar documents
RMHDT90SS/ - RMHDT100SS/ - RMHDT110SS/ Instructions Manual.

LEIHDS110SC/ LEIHDS110BC/ Instructions Manual.

EFC Instructions Manual

INDEX RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 6 INSTALLATION USE MAINTENANCE... 33

KSEV97X. IT Libretto Istruzioni GB Instruction Manual. 11 FR Manuel d Instructions 20 DE Bedienungsanleitung 29 NL Gebruiksaanwijzing

KH E, KH E

INSTRUCTIONS FOR MAINTENANCE AND USE KITCHEN EXTRACTOR HOOD ZRW 50/60

INSTRUCTIONS FOR INSTALLATION AND USE

Mod: KLD6-12/35XLAS-N

Astor 20 Colony Counter User s Manual

C3 Operating Instructions

220/240 AC x 25 W

T35 W35. Thermoelectric cooler Instruction Manual 6. Thermoelektrische Kühlbox Bedienungsanleitung 16. Glacière thermoélectrique Notice d emploi 27

Cordless Rechargeable Saw Instructions for Use

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

CORDLESS WORK LIGHT CORDLESS WORK LIGHT. Operation and Safety Notes IAN

Hood. warning. warning. caution

EN Instruction Manual

Gavita HortiStar 1000 DE EU/US

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

OPERATION & MAINTENANCE INSTRUCTIONS

INSTRUCTIONS FOR OPERATION

Sectional and Tilting Door Opener

15Amp Intelligent Battery Charger Suitable for SLA, Gel, Maintenance Free, AGM, Deep Cycle batteries

OPERATION & MAINTENANCE INSTRUCTIONS

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

MP V 8A Electronic Smart Charger. Instruction and Information Manual

OPERATION & MAINTENANCE INSTRUCTIONS

SL2380. Installer s guide. Owner skit. Blind control device Battery module.

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

Oscillating Tower Fan with Remote Control

1200W INVERTER GENERATOR

R18SPL. ORIGINAL INSTRUCTIONS 18V Dual Power LED Spotlight

7 Handle Tubes. 10 Charging Jack 11 LED Indicator 12 ON/OFF button

c-go 24V/6A 24V/8A 24V/12A

CORDLESS WORK LIGHT CORDLESS WORK LIGHT. Operation and Safety Notes IAN

Energy-Saving Under-Cabinet Light. Assembly and safety advice Z30802A-BS Z30802B-BS

User Manual TABLE MAGNIFIER TL-70. User-friendly Manual ID: #05007

Sectional and Tilting Door Opener Installation Instructions and User Guide

PAC 600 PAC 800 PAC 800 comfort

MODEL: AG-HA-950D GENERATOR OWNER S MANUAL

1-50 KVA SINGLE-PHASE SERVO REGULATOR INSTRUCTIONS FOR USE SERVO SINGLE-PHASE VOLTAGE REGULATOR

DIAGNOSTIC POWER SUPPLY WSC 720. user guide. 12 V/24 V lead acid batteries ah

General safety notes

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

OWNER S MANUAL POWER INVERTER

Smart Charger 12-24V 60A, 1600W

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

EXHAUST HOODS HNPD, HNPA, HPPD, HFPD, HNCD, HNCA, HPCD, HFCD, HKCD, HNPDC. Installation, Operation and Maintenance Manual

Description. ST-164 Dual injector. User Manual ST-164. Artikel-Nr.: XXX

GENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114

Installation Operation Parts

Owner skit. Manuale per l installatore Installer s guide Installations- Anweisungen Notice installateur SL2380

POWER PAK II / PLUS II

BEDIENUNGSANWEISUNG KD KD KD KD KD KDEM KDEM mit Montageanweisungen

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

Compressor Refrigerator Instruction Manual

MULTI FUNCTION POWER PAK PLUS

Battery Charger JCB-FCH20LI2

Industrial flue gas probes. Instruction manual

CoolFreeze CFX35, CFX40, CFX50, CFX65, CFX65DZ

SERVICE MANUAL (2)

Instruction manual. RP800 - HYDRAULIC actuator, load 150Kg. RP815 - LINAK actuator, load 150Kg

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1

TRICKLE CHARGER MODEL NO: ATC12VB OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS LS0618 ISS 2

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions

TOOLPRO 18V Li-Ion Brushless Impact wrench

Sectional And Tilting Door Opener

OPERATION MANUAL. TWE Pin Welder. Model TWP-2 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330) Revision 2.

USER GUIDE 12 V Lead acid batteries Ah

Installation manual wall-mounted distributor

PHOTOCAM IV D GB F RUS I H E LV LT S NL CZ EST SK SLO RO GR TR BG

SOLAR CHARGE CONTROLLER

Light oil - kerosene burner

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

E-P3 POLINI MOTOR USER S MANUAL

V3700UK OWNER S GUIDE.

FREQUENCY INVERTER INSTALLATION & USER GUIDE

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

Installation manual ACO Mains operated drain doser (MODD) for Grease Traps

Operating Instructions AC/Rechargeable Professional Hair Clipper

Operating instructions in the back. PD1420LP

2.0Ah BATTERY INSTRUCTION MANUAL

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

Roof access hatch installation instructions

Cordless Floor Polisher

AXIAL FANS Axis / Tubo OPERATION MANUAL

Gandalf Instructions for mounting and use

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

LDG6000SA DIESEL GENERATOR OWNERS MANUAL

Kerosene - oil burner

READ AND SAVE THE INSTRUCTIONS

4-VOLT LITHIUM-ION AUTO-LOAD SCREWDRIVER w/led WORKLIGHT

When Time Matters! listed Fire Damper

User Manual Central Vacuum System

Operating instructions in the back. PD1820LF

Transcription:

Instructions for use and installation Cooker Hood FTU 3807 WXS 70H FTU 3807-P WXS 70H

Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS...18 CHARACTERISTICS...19 INSTALLATION...20 USE...24 MAINTENANCE...25 EN 3

RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. INSTALLATION The manufacturer will not be held liable for any damages resulting from incorrect or improper installation. The minimum safety distance between the cooker top and the extractor hood is 550 mm. Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood. For Class I appliances, check that the domestic power supply guarantees adequate earthing. Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route of the flue must be as short as possible. Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.). If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air. USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells. Never use the hood for purposes other than for which it has ben designed. Never leave high naked flames under the hood when it is in operation. Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides. Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. Do not flambè under the range hood; risk of fire This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. 550 mm min. MAINTENANCE Switch off or unplug the appliance from the mains supply before carrying out any maintenance work. Clean and/or replace the Filters after the specified time period. Clean the hood using a damp cloth and a neutral liquid detergent. The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product. EN 1 18

CHARACTERISTICS Dimensions Components Ref. Q.ty Product components 1 1 Hood equipped with: Controls, Lights, Filters 3 1 Hood support equipped with the Exhaust Group 7 1 tube in PVC 8 1 Directioned grid 8c 1 Air outlet reduction ø 120mm 9 1 Reduction flange ø 150-120 mm Ref. Q.ty Installation components 11 4 Small blocks ø 10 12a 4 Screws 5 x 70 12b 4 Screws M4 x 15 12e 2 Screws 2,9 x 9,5 13 4 Screws plug M4 Q.ty Documentations 1 Instruction booklet 13 12e 8 8c 7 9 12b 1 3 12a 11 EN 1 19

INSTALLATION Wall drilling and bracket fixing Due to the complexity in installing the hood, we suggest to do it minimum in two people 100 100 170 175 12a 11 1050 100 100 550 mm MIN 826 390 When installing the hood in recycling version it has to be taken into consideration that space remaining between the hood and the upper limit (ceiling or self) is at least 8-10 cm. On the wall, draw: a Vertical line up to the ceiling or upper limit, at the centre of the area in which the hood is to be fitted; a Horizontal line at a minimum of 826 mm above the Cooker Top;. As indicated, mark a reference point at 100 mm to the right of the vertical reference line. Repeat this operation on the other side, checking that the two marks are level. As indicated, mark a reference point at 390 mm above the horizontal reference line, and at 100 mm to the right of the vertical reference line. Repeat this operation on the other side, checking that the two marks are level. Drill at the points marked, using a ø 10 mm drill bit. Insert the plugs 11 into the holes. EN 2 20

Hood support mounting Lean the hood support 3 against the wall making sure that holes in the hood support correspond to those in the wall. Block the hood support to the wall using 4 12a (5 x 70) screws 12a supplied with the hood. Before fastening the screws definitively make sure that the support is well-levelled. Only after this operation proceed with the definitive tightening of the screws. 3 Air outlet connection in the ducting version When installing the hood in ducting version, basing on the installer s choice, a rigid or a flexible pipe with a ø 150 o 120 mm is used in order to connect the hood to the air outlet piping. The pipe connection can be made on the upper part or on the back side of the hood. AIR OUTLET ON THE BACK SIDE OF THE HOOD When drilling the air outlet hole in the wall proceed in accordance with the scheme in the paragraph concerning the wall drilling. In case the connection is made with a ø 120 mm pipe insert the reduction flange 9 on the hood body outlet. Fix the pipe with an adequate quantity of pipe clamps. This material is not supplied together with the hood. Remove the charcoal filter if present. AIR OUTLET ON THE UPPER PART OF THE HOOD In case the connection of the hood to the air outlet piping is made with a ø 150 mm pipe then use a rigid or a flexible pipe. In case the connection is made with a ø 120 mm pipe insert the reduction flange 9 on the hood body outlet. Fix the air outlet reduction 8c to the air outlet hole of the hood support with the screws supplied together with the hood. Connect the hood to the piping with a rigid or a flexible pipe. Fix the pipe with an adequate quantity of pipe clamps. This material is not supplied together with the hood. Remove the charcoal filter if present. 8c ø 120 9 ø 150 EN 2 21

RECIRCULATION VERSION AIR OUTLET Insert pvc pipe 7 provided onto the Hood Canopy Outlet.. 7 ø 150 Hood body mounting Ducting version In case the air outlet connection on the upper part of the hood has been chosen it will be necessary to remove the pre-cut piece. Lean the hood body on the support and fix it laterally with the 4 12b screws. Cover the screw seats with the plugs 13 supplied with the hood. 13 Recycling version Remove the pre-cut piece. Lean the hood body on the support and fix it laterally with the 4 12b screws. Cover the screw seats with the plugs 13 supplied with the hood. Place the directioned grid 8 on the pipe and make sure that it is correctly installed. Fix the directioned grid 8 with the screws 12e supplied together with the hood. Make sure that the charcoal filters are present. 8 12e 12b EN 2 22

ELECTRICAL CONNECTION Connect the hood to the mains through a twopole switch having a contact gap of at least 3 mm. Open the lighting unit by pulling on the notch. Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time. Being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan. Connect the control connector Cmd. Connect the Spotlights connector Lux to the socket provided behind the lighting unit cover. Replace the filters, make sure that the handle is visible on the outside, and the lighting unit. Cmd Lux EN 2 23

USE A D B C E F G H Control board Key Function Display A Switches the extractor motor on and off at the Indicates the selected speed. latest selected speed B Decreases the suction speed. C Increases the suction speed. D E F By pressing this key it is possible to activate the intensive speed from any previously selected speed. The intensive speed can be activated even when the motor is OFF. This speed has been timed at 10 minutes. After that time the system activates automatically the latest selected speed. This function is suitable for cooking conditions when vapours and smells are of the utmost emission. By pressing this key it is possible to set up the motor to a suction speed at 100 m 3 /h lasting 10 minutes every hour. After this the motor switches off automatically. When the filter saturation is going on it is possible to reset the alarm by pressing this key for about 3 seconds. The indication is visible only when the motor is off. By pressing this key it is possible to set the delayed shutdown of the appliance to 30 minutes. This function is suitable for a complete elimination of the residual smells. It can be activated at any position, and it is deactivated by pressing the key again or by switching off the motor. G Turns light on and off. H Turns light on and off at reduced intensity. HI appears. The spot down on the right side flashes once a second. Indicates the 24-function. The spot down on the right side flashes and the motor is on. Once the process is finished the previous indication disappears: FF Indicates that the metal grease filters saturation alarm has been triggered, and the filters need to be washed. The alarm is triggered after 100 working hours. EF Indicates that the charcoal filter saturation alarm has been triggered, and the filter has to be replaced; the metal grease filters must also be washed. The charcoal filter is triggered after 200 working hours. Indicates alternately the selected speed of the hood and the time left before the hood shutdown. The spot down on the right side flashes. EN 2 24

MAINTENANCE REMOTE CONTROL (OPTIONAL) The appliance can be controlled using a remote control powered by a 1.5 V carbon-zinc alkaline batteries of the standard LR03- AAA type. Do not place the remote control near to heat sources. Used batteries must be disposed of in the proper manner. Cleaning the Comfort Panels Pull the Comfort Panel to open it. Disconnect the panel from the hood canopy by sliding the fixing pin lever. The comfort panel must never be washed in a dishwasher. Clean the outside using a damp cloth and neutral liquid detergent. Clean the inside as well using a damp cloth and neutral detergent; do not use wet cloths or sponges, or jets of water; do not use abrasive substances. When the above operation has been completed, hook the panel back to the hood canopy and close it by turning the knob in the opposite direction. EN 2 25

Metal grease filters Filters can be washed in the dish machine. They need to be washed when FF-sign appears on the display or in any case every 2 months, or even more frequently in case of particularly intensive use of the hood. Alarm reset Switch off the hood and the lights. If the 24hfunction has been activated this has to be deactivated. Press the E-key till the display is unlit. Cleaning the filters Pull the comfort panels to open them. Remove the filters one by one pushing them towards the back side of the hood unit and simultaneously pulling downwards. Any kind of bending of the filters has to be avoided when washing them. Before fitting them again into the hood make sure that they are completely dry. (The colour of the filter surface may change throughout the time but this has no influence to the filter efficiency). When fitting the filters into the hood pay attention that they are mounted in correct position the handle facing outwards. Close the comfort panel. EN 2 26

Charcoal filter (recycling version) This filter cannot be washed or regenerated. It must be replaced when the EF appears on the display or at least once every 4 months. Activation of the alarm signal In the recycling version hoods the filter saturation alarm must be activated during the installation or later. Switch off the hood and the lights. Disconnect the hood from the mains supply. When restoring the connection press and hold B-key. When releasing the key two rotating rectangles appear on the display. Within 3 seconds press the B-key until a flashing confirmation appears on the dispaly: 2 flashes with EF - charcoal filter saturation alarm ACTIVATED 1 flash with EF - charcoal filter saturation alarm DEACTIVATED. REPLACING THE CHARCOAL FILTER Reset of the alarm signal Switch off the hood and the lighting. If the 24h-function has been activated this has to be deactivated. Press the E-key until the display is unlit. Replacing of the filter Open the comfort panels pulling them downwards. Remove the metal grease filters. Remove the saturated charcoal filter by releasing the fixing hooks Fit the new filter and fasten it in its correct position. Put the metal grease filters in their seats. Close the comfort panels. Lighting LIGHT REPLACEMENT 20 W halogen light. Remove the 2 screws fixing the Lighting support, and pull it out of from the Hood. Extract the lamp from the Support. Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes. Replace the Support, fixing it in place with the two screws removed as above. EN 2 27