Fume cupboard systems

Similar documents
DATA SHEETS. Fume cupboard systems Walk-in fume cupboard (DB)

Fume cupboards and extraction devices

Then all roads lead to LACONT!

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

Heating oven with natural convection

3.5 Exposure Control Measures

Heating oven with mechanical control

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75. Alsident System 100. Chemical Resistant (CR) Product Information SYSTEM 100 CR

1.7. Type 30. Safety cabinets with wing doors/drawers

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 SYSTEM 100 AL. Alsident System100. Aluminium (AL) Product Information

DURAN GROUP DISPENSER & DURAN GROUP DISPENSER PRO. A safe and precise dispensing system

TFS 1000 EXTRACTION / FILTER / POLLUTION CONTROL // TECHNOLOGY

ALSIDENT SYSTEM 75. Easily positioned all-round fume extraction arm

innovative. reliable. international ORIGINAL DÜPERTHAL NEW: active SAFETY without compromise!

Extraction arm FX100 Original

Freefall metal detection system Vistus with separator FL

Air Displacement Vent Units

Freefall metal detection system Vistus with separator EC

Safety drying oven with expended temperature range

Heating oven with mechanical convection

Freefall metal detection system Vistus with separator ST 2.0

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

Centrifugal fan with highly efficient EC drive motor

Small centrifugal fans made of plastic

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

1 Safety Cabinets. Underbench cabinets The flexible - fits under your fume hood

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

SYSTEM10. Airflow Alarm

JUMBO. Fume Extraction Technology. Compact and Versatile. Filtertrolley 2.0. Extraction. Filtration. Persistence.

Swing Piston Compressors and Vacuum Pumps

Salt Spray Chamber HKT 1000

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 PP SYSTEM 100 ALSIDENT SYSTEM 75. Chemical Resistant (CR) Product Information

Safety drying ovens with expanded temperature range

Humidity Cabinet HYGROTHERM

Heating chamber with mechanical convection

Dismounting of rolling bearings Hydraulic dismounting

Polypropylene Total Exhaust Fume Hoods

January, 2014 Page 1 of 6

Safety drying ovens. Advantages: Areas of application: FDL series 115

Heating chamber with mechanical convection

BenchTop Extraction Arm FX2

Circulaire. Superb Containment, Excellent Capacity. Filtration Fume Cabinets

Supplementary instructions. Mounting accessories, pressure measurement technology. Document ID: 43478

Drying ovens. ED 53 - Drying oven with natural convection. Performance features and equipment :

Trox-o-mat Automatic Roll Filters F1/1/EN/5

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Installing a Purged Packed (PP) Inlet

Mobile recleanable HEPA filter units for a flow of m 3 / h

Version with operating bar

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Fume Hood Standard. The appropriate maintenance/engineering division on each campus or other business unit operating on UofT property shall:

Process Inline Filter PLF1

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Products and Solutions

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

TOP QUALITY SOLUTIONS FOR YOUR LABORATORY

Process Inline Filter Protective filter PLF2-9HF

Novenco Tunnel Fans. Novax October 2007

Talos revolving doors

Perfect Liquid Handling PRECISE RESULTS WITH INNOVATIVE TECHNOLOGY

EN. Cupboard Trolleys. Versatile Innovative Excellent.

Krantz. Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems

How to Use a Chemical Fume Hood Safely

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

Catalogue of Accessories

LINEARIS Electrical linear motion drive / Damper actuator

Dental Art presents Alchemist

USER'S GUIDE TO FUME HOODS. Procedures for Increasing the Effectiveness of Laboratory Hoods. Revised December, Hood Basics

Electronic Enclosures Technical Information 445/441 Panel Instrument Cases Acc. to DIN 43700/IEC 61554

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Heating chamber with mechanical convection

Dynamic DC Emulator Efficient testing of charging technology and power electronics

Cable thermocouple Model TC40

HAZARDOUS SUBSTANCES DRUM CABINETS

biolus BIO SAFETY CABINET

INTERNAL STORAGE OF HAZARDOUS MATERIALS TOP QUALITY MADE IN GERMANY

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

CIRCULAIRE FILTRATION FUME CUPBOARDS with Visionaire.

Heating chamber with mechanical convection

PSI CASING SPACERS TYPE DSI

200-SERIES EXTRACTION

2/2- and 3/2-way solenoid valve for aggressive fluids

Operating instructions

RE / STAR Tolerance Rings STAR Ball Knobs, Knob and Lever Type Handles

FUME CUPBOARDS EXTRACT SUPPLY FURNITURE SYSTEM WORKBENCHES

2/2-way Globe Valve for media up to +180 C, DN

Dräger Linea Medical Supply Units

Product Data For FARNELL

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

Mini Arms 4" Diameter

NEW: RAUFILAM -E COLOUR ALWAYS THE RIGHT CHOICE. Industrial hoses, with and without fabric lining

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Drivers Cabin Entrance Door CaraD-I300plus Art. 1402

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

Annexure-1. Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4)

Installation Guide. Flame Ionization Detector on a 6850 GC Accessory G2621

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

BenchTop Extraction Arm FX2

Thermocouple Model TC10-H without thermowell

DCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC

Transcription:

69 DATA SHEETS Fume cupboard systems Bench-mounted fume cupboard (DS)

10

11 GENERAL INFRMATIN Fundamental safety and performance targets The DELTAguard bench-mounted fume cupboard is designed in such a way that hazardous airborne pollutant concentrations or quantities do not escape from the fume cupboard into the room; hazardous substances are efficiently removed to reduce the risk of formation of an explosive or hazardous atmosphere in the interior of the fume cupboard; the user is protected against splashing and splinters by a front sash. The DELTAguard bench-mounted fume cupboards comply with the standards of DIN EN 14175 Parts 1-3. All fume cupboards are subject to prototype testing by an independent aerotechnical test institute. The fume cupboard emissions have all been far under the limit values of BG Chemie. They meet the safety requirements in all respects. Note: Separate types of fume cupboard are available for high thermal loads with acid digestions or for dealing with unsealed radioactive substances. PRDUCT ADVANTAGES Fume cupboard tested and certified in accordance with DIN EN14175 ptimized pollutant retention capacity with, at the same time, low exhaust air volume flows Maximum usable inner workspace, due to extra-narrow fume cupboard sides Maximum visibility through the use of standard top glazing (glass skirting) Worktops and interior surfaces according to requirements Worktop with moulded, flow-optimized front rim Exhaust air system with optimized air intake zones for a full-surface extraction above the work surface Ergonomically designed sash handle bar for easy, one-handed operation of the sliding sash, with twist-lock release mechanism Maintenance-friendly thanks to large inspection panel, simple-to- disassemble installations and easily-replaced table tops Electrical panels on both sides of the interior High installation density possible, no overlap of the service outlet and stand areas Standard battery-buffered exhaust air monitoring unit with IR interface Integrated function and control panel at eye level in the pilaster, optionally with a graphical LED function display on which all main operating and status information of the fume cupboard is directly readable (e.g. volume flow, inflow, as well as error and operating messages) ptional: Substructure or hazardous substances cabinet Wide range of accessories and options, such as automatic motorized sash drive, fume cupboard control (with integrated Web server and EC-efficiency indicator, by means of which the energy demand of the individual mode of operation is determined and represented by averaging in comparison to other fume cupboards networked in the laboratory building) ptional: Available with active air-injection system

12 TECHNICAL DATA Grid 1200 1500 Dimensions 1800 Interior Front sash 2100 Width (outer) mm 1200 1500 1800 2100 Depth (outer) Standard mm 910 Depth (outer) Alternative mm 1070 Height (outer) mm 2730 Width (inner) mm 1160 1460 1760 2060 Depth (inner) Standard mm 710 (690) Depth (inner) Alternative mm 870 (850) Height (inner) mm 1500 Weight kg 310 340 380 420 Interior surface Melamine resin X Side panels coated, 0.8 mm HPL Polypropylene (PP) Ceramic (SZ) Stainless steel (CNS) Worktop Stoneware X Polypropylene (PP) Stainless steel (CNS) Drip cup Rear right (preferred position) Rear centre Rear left Rod holder 2 rows X 3 rows X X 4 rows X Cross-slide without *1 2-fold X 3-fold 4-fold peration manual X electrical, incl. motion detector Design simple X

13 Grid 1200 1500 Elektrical service outlets Sanitary service outlets Additional equipment 1800 2100 Electrical panels on both sides in interior, sockets switched outside *2 System duct Electrical service outlet *2 Service fitting points in grid 75 mm in interior (water, gases, vacuum) *2 System duct Front control valves *2 Side glazing right Media feed-through D = 100 mm left right left Substructure Base cabinet Substructure extraction Construction material class B1 flame-resistant Ex-Explosion protection Electrostatic charge dissipation capability *3 X Standard ptional *)1 Necessary for extinguishing fume cupboards *)2 Media and electrical service outlets freely selectable *)3 not in combination with DELTAprotect and/or electric window regulators

14 AERTECHNICAL DATA Grid 1200 1500 1800 2100 Model DELTAguard DS-DG03 DELTAguard + DELTAprotect DS-DG03-P DELTAguard + DELTAcontrol DS-DG03 DELTAguard + DELTAcontrol + DELTAprotect DS-DG03-P Equipment Exhaust air monitoring (unregulated) Exhaust air monitoring (unregulated Active air-injection system Volume flow regulation (regulated) Volume flow regulation (regulated) Active air-injection system Exhaust air volume I Pressure loss m 3 /h Pa m 3 /h Pa m 3 /h Pa m 3 /h Pa tested 420 42 525 59 630 59 735 62 recomm. V min. 480 55 600 77 720 76 840 79 recomm. V max. 600 86 750 117 900 113 1050 117 tested 300 25 375 32 450 34 525 35 recomm. V min. 360 34 450 46 540 48 650 52 recomm. V max. 480 60 600 80 720 82 840 83 tested 420 33 525 45 630 40 735 38 recomm. V min. 1 200 8 200 7 200 4 200 3 recomm. V max. 2 480 43 600 59 720 52 840 50 tested 300 19 375 24 450 23 525 21 recomm. V min. 1 200 8 200 7 200 5 200 3 recomm. V max. 2 360 27 450 35 540 33 650 32 1 Front sash closed 2 Front sash open The tested values are air quantities determined under test room conditions in accordance with DIN EN 14175. ur experience has shown that higher air volumes may be necessary in practice. Therefore the recommended values are sometimes higher. When designing the ventilation system, please note that respective pressure losses must be taken into account. As a planning value, an average of approx. 100-150 Pa/fume cupboard with regulation can be assumed. An adjustment of the minimum volume flow may be necessary. ur experts will be pleased to provide you with advice and assistance during every phase of the project talk to us.

15 DIMENSINS - EXTERNAL AND INTERNAL D Ø 250 230 H 2730 ption Ex airregulation 2820 K-Ex air vents 2625 K-Fume cupboard ceiling 2420 40 G F Inner height 1500 Work height 900 pening height 1800 A E B C Grid width A 1200 1500 1800 2100 Interior width B 1160 1460 1760 2060 pening width C 1140 1440 1740 2040 Fume cupboard total depth D 910 1070 Total depth E 940 1100 Usable depth worktop F 720 880 Usable depth in area of front sash G 710 870 Usable depth in area of skirting H 690 850

www.wesemann.com Wesemann GmbH Headquarters Max-Planck-Straße 15-25 28857 Syke Germany Telephone +49 (0) 42 42 594-0 Telefax +49 (0) 42 42 594-333 E-Mail info@wesemann.com 11.17 E Changes to colours, dimensions and technical design to improve performance are reserved. No reproduction or reprint without our permission.