DATA SHEETS. Fume cupboard systems Walk-in fume cupboard (DB)

Similar documents
Fume cupboard systems

Fume cupboards and extraction devices

Then all roads lead to LACONT!

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

Heating oven with natural convection

JUMBO. Fume Extraction Technology. Compact and Versatile. Filtertrolley 2.0. Extraction. Filtration. Persistence.

3.5 Exposure Control Measures

Heating oven with mechanical control

Safety drying oven with expended temperature range

DURAN GROUP DISPENSER & DURAN GROUP DISPENSER PRO. A safe and precise dispensing system

Air Displacement Vent Units

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75. Alsident System 100. Chemical Resistant (CR) Product Information SYSTEM 100 CR

ALSIDENT SYSTEM 75. Easily positioned all-round fume extraction arm

innovative. reliable. international ORIGINAL DÜPERTHAL NEW: active SAFETY without compromise!

Heating chamber with mechanical convection

Heating oven with mechanical convection

Heating chamber with mechanical convection

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

Talos Revolving Doors Talos Circular Sliding Doors

Trox-o-mat Automatic Roll Filters F1/1/EN/5

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 SYSTEM 100 AL. Alsident System100. Aluminium (AL) Product Information

TFS 1000 EXTRACTION / FILTER / POLLUTION CONTROL // TECHNOLOGY

biolus BIO SAFETY CABINET

Swing Piston Compressors and Vacuum Pumps

Safety drying ovens with expanded temperature range

Perfect Liquid Handling PRECISE RESULTS WITH INNOVATIVE TECHNOLOGY

1 Safety Cabinets. Underbench cabinets The flexible - fits under your fume hood

Dismounting of rolling bearings Hydraulic dismounting

Extraction arm FX100 Original

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

Centrifugal fan with highly efficient EC drive motor

Safety drying ovens. Advantages: Areas of application: FDL series 115

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

Polypropylene Total Exhaust Fume Hoods

Talos Revolving Doors Talos Circular Sliding Doors

Supplementary instructions. Mounting accessories, pressure measurement technology. Document ID: 43478

Drying ovens. ED 53 - Drying oven with natural convection. Performance features and equipment :

Freefall metal detection system Vistus with separator FL

SYSTEM10. Airflow Alarm

Installing a Purged Packed (PP) Inlet

Freefall metal detection system Vistus with separator EC

Salt Spray Chamber HKT 1000

Dräger Linea Medical Supply Units

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Decorative radiators Comfortable indoor ventilation Heating and cooling ceiling systems Clean air solutions Zehnder ComfoWell 220

Freefall metal detection system Vistus with separator ST 2.0

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

1.7. Type 30. Safety cabinets with wing doors/drawers

Catalogue of Accessories

TORRIX Magnetostrictive level sensor

Heating chamber with mechanical convection

(Class II Type A2 & B2)

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Humidity Cabinet HYGROTHERM

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 PP SYSTEM 100 ALSIDENT SYSTEM 75. Chemical Resistant (CR) Product Information

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Heating chamber with mechanical convection

THE NEW TS IT RACK 8

NOVELTY. Platin flat rainwater tank. GRAF s version of the flat tank. Integrated filter. Attractive tank. installation depth Suitable for.

200-SERIES EXTRACTION

PSI CASING SPACERS TYPE DSI

Fume Hood Standard. The appropriate maintenance/engineering division on each campus or other business unit operating on UofT property shall:

Operating instructions

INTERNAL STORAGE OF HAZARDOUS MATERIALS TOP QUALITY MADE IN GERMANY

HAZARDOUS SUBSTANCES DRUM CABINETS

Talos revolving doors

BenchTop Extraction Arm FX2

7 Services Control and monitoring

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

Drivers Cabin Entrance Door CaraD-I300plus Art. 1402

Products and Solutions

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

TOP QUALITY SOLUTIONS FOR YOUR LABORATORY

Carisma CRC. Range includes 9 air rates (from 105 to 1500 m 3 /h) It is the most comprehensive range, perfectly suited to meet

Cable thermocouple Model TC40

LINEARIS Electrical linear motion drive / Damper actuator

Maximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment

N086, N186, N786. Pressure retaining valve, Plastic

Differential pressure transmitter PASCAL Ci4 Delta P

MESSKO MTO Oil Level Indicator

January, 2014 Page 1 of 6

Technical Principles of Valves

Volumeter. RMG Meßtechnik GmbH. Publication No E

ALSIDENT SYSTEM 50. A small flexible extraction arm

Dynamic DC Emulator Efficient testing of charging technology and power electronics

Standard-efficiency gas heating. Innovation is our tradition.

Ceiling air diffuser INDULCLIP INDUDRALL KOMBICLIP

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

LABORATORY FUME HOODS

Mobile recleanable HEPA filter units for a flow of m 3 / h

bott vario Professional Vehicle Equipment for your Peugeot Estate cars Bipper Partner Expert Boxer

FUME CUPBOARDS EXTRACT SUPPLY FURNITURE SYSTEM WORKBENCHES

Explosion-protected surface-mounting Thermostat ATH-Ex Series

RE / STAR Tolerance Rings STAR Ball Knobs, Knob and Lever Type Handles

Air operated Pinch Valve type VMC

KITO explosion and endurance burning flame arrester devices

Transcription:

69 DATA SHEETS Fume cupboard systems Walk-in fume cupboard (DB)

28

29 GENERAL INFRMATIN Fundamental safety and performance targets The walk-in fume cupboard is designed in such a way that hazardous airborne pollutant concentrations or quantities do not escape from the fume cupboard into the room; hazardous substances are efficiently removed to reduce the risk of formation of an explosive or hazardous atmosphere in the interior of the fume cupboard; the user is protected against splashing and splinters by a front sash. The walk-in fume cupboards comply with the standards of DIN EN 14175 Parts 1-3. All fume cupboards are subject to prototype testing by an independent aerotechnical test institute. The fume cupboard emissions have all been far under the limit values of BG Chemie. They meet the safety requirements in all respects. Note: Separate types of fume cupboard are available for high thermal loads with acid digestions or for dealing with unsealed radioactive substances. PRDUCT ADVANTAGES Fume cupboard tested and certified in accordance with DIN EN 14175 Synchronous-running telescope sliding sash for high operating comfort ptimized pollutant retention capacity with simultaneous low exhaust air volume flows Maximum usable inner workspace, due to extra-narrow fume cupboard sides Maximum visibility through the use of standard top glazing (glass skirting) Worktops and interior surfaces according to requirements Exhaust air system with optimized air intake zones for a full-surface extraction above the work surface Ergonomically designed sash handle bar for easy, one-handed operation of the sliding sash Maintenance-friendly thanks to large inspection panel, simple-to-disassemble installations and easily replaced worktops Electrical panels on both sides of the interior High installation density possible, no overlap of the service outlet and stand areas Standard battery-buffered exhaust air monitoring unit with IR interface Integrated function and control panel at eye level in the pilaster, optionally with a graphical LED function display on which all main operating and status information of the fume cupboard is directly readable (e.g. volume flow, inflow, as well as error and operating messages) Wide range of accessories and options, such as automatic motorized sash drive, fume cupboard control (with integrated Web server and EC-efficiency indicator, by means of which the energy demand of the individual mode of operation is determined and represented by averaging in comparison to other fume cup boards networked in the laboratory building)

30 TECHNICAL DATA Grid 1200 Dimensions 1500 Interior Front sash 1800 2100 Width (outer) mm 1200 1500 1800 2100 Depth (outer) Standard mm 910 Depth (outer) Alternative mm 1070 / 1270 Height (outer) mm 2730 Width (inner) mm 1160 1460 1760 2060 Depth (inner) Standard mm 680 Depth (inner) Alternative mm 840 / 1040 Height (inner) mm 2400 Weight kg 270 290 310 355 Interior surface Melamine resin X Side panels lined, 0.8 mm HPL Polypropylene (PP) Ceramic (SZ) Stainless steel (CNS) Edelstahl (CNS) Worktop n-site floor X Stoneware Stainless steel (CNS) Drip cup in energy service panel Rod holder 2 rows X 3 rows X X 4 rows X Cross-slide without *1 2-fold X 3-fold 4-fold peration manual X electrical, incl. motion detector Design telescopic X

31 Grid 1200 1500 1800 Electrical service outlets Sanitary service outlets Additional equipment 2100 Electrical panels both sides in interior, sockets switched outside *2 System duct Electrical service outlet *2 Service fitting points im grid 75 mm in interior (water, gases, vacuum) *2 System duct Front control valves *2 Side glazing right Media feed-through D = 100 mm left right left Construction material Class B1 flame-resistant Ex-Explosionsschutz Electrostatic charge dissipation facility *3 X Standard ptional *)1 necessary for extinguishing fume cupboards *)2 Media and Electrical service outlets freely selectable *)3 not in combination with DELTAprotect and/or electric window regulator

32 AERTECHNICAL DATA Grid 1200 1500 1800 2100 Exhaust air volume I Pressure loss Model Equipment m 3 /h Pa m 3 /h Pa m 3 /h Pa m 3 /h Pa Depth 910 mm DELTAguard DB-DG03 DELTAguard + DELTAcontrol DB-DG03 Exhaust air monitoring (unregulated) Volume flow regulation (regulated) tested 420 25 525 49 630 45 735 57 recomm. V min. 480 33 600 64 720 58 840 71 recomm. V max. 720 71 900 135 1080 111 1080 104 tested 420 16 525 35 630 26 735 32 recomm. V min. 1 240 5 300 11 300 6 400 9 recomm. V max. 2 480 21 600 46 720 34 840 42 Grid 1200 1500 1800 2100 Exhause air volume I Pressure loss Model Equipment m 3 /h Pa m 3 /h Pa m 3 /h Pa m 3 /h Pa Depth 1070 / 1270 mm DELTAguard DB-DG03-1070 DB-DG03-1270 DELTAguard + DELTAcontrol DB-DG03-1070 DB-DG03-1270 Exhaust air monitoring (unregulated) Volume flow regulation (regulated) tested 720 900 1080 1260 recomm. V min. 720 900 1080 1260 recomm. V max. 870 1050 1230 1350 tested 720 900 1080 1260 recomm. V min. 1 330 400 480 560 recomm. V max. 2 720 900 1080 1260 1 Front sash closed 2 Font sash open The tested values are air quantities determined under test room conditions in accordance with DIN EN 14175. ur experience has shown that higher air volumes may be necessary in practice. Therefore the recommended values are sometimes higher. When designing the ventilation system, please note that respective pressure losses must be taken into account. As a planning value, an average of approx. 100-150 Pa/fume cupboard with regulation can be assumed. An adjustment of the minimum volume flow may be necessary. ur experts will be pleased to provide you with advice and assistance during every phase of the project talk to us.

33 DIMENSINS EXTERNAL AND INTERNAL 230 D Ø 250 H 2730 ption Ex airregulation 2820 K-Ex air vents 2625 K-Fume cupboard ceiling 2420 40 G pening height 1800 Inner height 2400 I A 184 E B C Grid width A 1200 1500 1800 2100 Interior width B 1160 1460 1760 2060 pening width C 1140 1440 1740 2040 Fume cupboard depth D 910 1070 1270 Total depth E 940 1100 1300 Usable depth in area of front sash G 710 870 1070 Usable depth in area of skirting H 650 810 1010 Usable depth in area of telescope sash I 680 840 1040

www.wesemann.com Wesemann GmbH Headquarters Max-Planck-Straße 15-25 28857 Syke Germany Telephone +49 (0) 42 42 594-0 Telefax +49 (0) 42 42 594-333 E-Mail info@wesemann.com 11.17 E Changes to colours, dimensions and technical design to improve performance are reserved. No reproduction or reprint without our permission.