Issue Date: April 2018 Fixture/Location Ref: Project Ref: ProSpex 3.5 Soft Triple Soft Triple Trimless Downlight The ProSpex 3.5 Soft Multi forms part of our extensive range of Trimless downlights, available in fixed and adjustable variants. Deep recessed lamp for minimal glare, all available for many light sources including Lucent s own series of modules. Housing Mounting Tray Product Description Mud-in kit for seamless flush installation Die cast aluminium construction 3.38 (86mm) diameter aperture Spaced at 10 o.c.(254mm) Deep regressed lamp position for minimal glare utout 3x Ø4.13 (105mm) onsistent spacing between downlights Accepts up to 2 media accessories Easy rotation and re-lamping with ball-catch mechanism White or matte Black as standard Other spacing s and multiple can be provided to special order O.. Height L L1 W W1 10.00 (254mm) 7.30 (185mm) 30.60 (778mm) 35.15 (893mm) 12.00 (305mm) 14.45 (369mm) To specify the fixture, LED module and installation kit/housing as follow: 1) Specify the housing and control protocol 2) Specify fixture type and LED type opyright 2014 Lucent Lighting Inc. Tel. New York: +1 518 239 8300 Page 01
Please specify either Housing or Tray order code depending on your requirements Housing Order ode: LH-M3-11.25 Height LH-M3-11.25 11 1/4 Triple Housing Housing Type I Insulated eiling AT Airtight eiling, EA NI Non-Insulated eiling Mounting Hardware 14 14 to 24 BB Butterfly Bracket B aterpillar Bracket Supply Voltage 120 120V 277 277V Protocol S Switched P TRAI/Phase (120V ONLY) LP Lutron Forward Phase 2-Wire (120V ONLY) ESS EcoSystem 5-Series 5% LHE EcoSystem Hi-lum 1% Fade to Black LAE Lutron 3-Wire Hi-Lume 1% A Analog ED EldoLED DALI EA EldoLED Analog Tray Order ode: Tray Size M3 Housing Type NI LMT Triple Tray Non-Insulated eiling Mounting Hardware 09 9 to 15.25 14 14 to 24 M3 NI Supply Voltage 120 120V 277 277V Protocol S Switched P TRAI/Phase (120V ONLY) LP Lutron Forward Phase 2-Wire (120V ONLY) ESS EcoSystem 5-Series 5% LHE EcoSystem Hi-lum 1% Fade to Black LAE Lutron 3-Wire Hi-Lume 1% A Analog ED EldoLED DALI EA EldoLED Analog opyright 2014 Lucent Lighting Inc. Tel. New York: +1 518 239 8300 Page 02
Issue Date: January 2017 Fixture/Location Ref: Project Ref: ProSpex 3.5 Soft Soft Fixed Downlight The ProSpex 3.5 Soft forms part of our extensive range of Trim or Trimless downlights, available in fixed and adjustable variants. Deep recessed lamp for minimal glare, all available for many light sources including Lucent s own series of modules. Die cast aluminium construction Die cast aluminium trim ring 3.54 (90mm) diameter aperture Deep regressed lamp position for minimal glare Accepts up to 2 media accessories Damp location version available Flangeless Soft Fixed Flangeless A090-LED-TL Mud-in kit for seamless flush finish Fixed Version Page 03
Photometric Diagrams -830-14, 3000K, 14-830-32, 3000K, 32 Information LED Type XP-G2 XP-G2 XP-G2 T 3000K 3000K 3000K Drive urrent 350mA 500mA 700mA Power inc Driver 13.2W 19W 26.5W Beam Angle 14 32 14 32 14 32 Source Lumens 1468 1478 1966 2024 2478 2561 Delivered Lumens 1382 1059 1821 1396 2079 1593 Intensisty cd 16936 3147 22314 4147 25473 4734 Efficacy lm/w 105 80 96 73 78 60 R9 8 8 8 8 8 8 TM30 81.8 81.8 81.8 81.8 81.8 81.8 Forward Volt 36V 36V 36V RI 80 80 80 *Data correct at time of publishing LED Module Order ode: Lamp T 827 80 RI 2700K 830 80 RI 3000K 840 80 RI 4000K Beam 14 14 32 32 Page 04
Fixture Order ode: A090 Fixture A090 LED Flange TL 3.5 Soft Downlight Flangeless Finish WH BK RAL eiling Thickness 12 1/2 58 5/8 White Black Special olor 75 3/4 ustom Location DP Damp Media at LED (Blank) None Louvre LL45 Honeycomb Lens LLDF Solite LLFR Frosted LLLS Linear Spread LLHS Heavy Spread LL Warm Tone LLUV UV Page 05
Driver Information Manufacturer Driver Input Voltage Mains Frequency Dimming Range Output Power Efficacy urrent Ambient Temp Harvard LK33 0-10V 120-277VA 47-63Hz 100%-1% 11-33W 85% 100-1050mA -25-50 EldoLED EldoLED DALI 120-277VA 50-60Hz 100%-0% 30W 84% 200-1050mA -20-50 EldoLED EldoLED 0-10V 120-277VA 50-60Hz 100%-0% 30W 84% 150-1400mA -20-50 Lutron Hi-Lume Phase 120VA 50-60Hz 100%-1% 2-48W 79% 350-700mA -20-50 Harvard L Standard 120-277VA 47-63Hz N/A 9-33W 87% 350-1000mA -25-40 Lutron Hi-Lume EcoSystem 120-277VA 50-60Hz 100%-1% 2-48W 81% 350-700mA -20-50 Emergency: EM Driver P05 P07 P12 5 Watts 7 Watts 12 Watts P05: Input Voltage Input Rating Output Voltage Range Output urrent Output Power Power Factor Emergency Operation 120-277VA, 50/60Hz 2.7 Watts (max) 10-60VD lass 2 ompliant 0.5A (@10VD) - 0.08A (@60VD) 5 Watts 0.9 90 Minutes P07: Input Voltage Input Rating Output Voltage Range Output urrent Output Power Power Factor Emergency Operation 120-277VA, 50/60Hz 3.5 Watts (max) 10-60VD lass 2 ompliant 0.7A (@10VD) - 0.12A (@60VD) 7 Watts 0.9 90 Minutes P12: Input Voltage Input Rating Output Voltage Range Output urrent Output Power Power Factor Emergency Operation 120-277VA, 50/60Hz 5.0 Watts (max) 10-60VD lass 2 ompliant 1.2A (@10VD) - 0.2A (@60VD) 12 Watts 0.9 90 Minutes Page 06
Installation Instructions for 3.5 Soft Fixed Flangeless with Housing For Insulated and Non-Insulated eiling type installations! MAINS POWER TO BE SWITHED OFF DURING INSTALLATION. 1. Fixing of housing 2. Plasterboard installation utout (): Ø4.13 (105.0mm) 3. Trimless mud in kit installtion 4. Mud in and allow to dry fully 5. Paint and allow to dry fully 6. Dropdown of power supply 7. Fixture wiring connection 8. Power supply re-installation 9. Safety wire connection 10. Align fixture with trimless kit and Install 11. Finished Installation Page 07
Installation Instructions for 3.5 Soft Fixed Flangeless with Tray For Insulated and Non-Insulated eiling type installations! MAINS POWER TO BE SWITHED OFF DURING INSTALLATION. 1. Fixing of tray 2. Plasterboard installation utout (): Ø4.13 (105.0mm) 3. Trimless mud in kit installtion 4. Mud in and allow to dry fully 5. Paint and allow to dry fully 6. Dropdown of power supply 7. Fixture wiring connection 8. Power supply re-installation 9. Safety wire connection 10. Align fixture with trimless kit and Install 11. Finished Installation Page 08