MODEL GSW Deutz.

Similar documents
MODEL GSW80 Deutz & 110 Perkins.

SG101TDA 102,5 (82,0) 108,1 (86,5) 0, ,6 mm Water. Water n disp. 112,0 l/h 91,1 23,0 28,0 217.

MODEL GBW15-22 Yanmar

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW170I. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW80I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW145I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

MSW Series P. Main applications: Construction Mobile Workshop Emergency stand-by (residential / industry) Island/Mains synchro (from 100kVA)

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW145V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS-110V. Power Rating Standby power LTP kva Standby power LTP kw Prime power PRP kva Prime power PRP kw 81.14

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

GSW275V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMR - 67P 67P 09/05/2016 GMR - 067P

GSW570M. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW275P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GMS - 600V 06/05/2016 GMS - 600V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

EN-GM GENERAC MOBILE PRODUCTS 50Hz POWER GENERATORS GENERAL CATALOGUE

GSW555V. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW415V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW415P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GSW-705V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

P6000s 230V 50Hz #CONN #DPP

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

GE.PK.022/020.SS+0_all

S V50HZ #AVR #CONN #DPP

THE COMPLETE PETROL PACKAGE

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW870M. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

OptionsChartsGenerators_r1_4_EN. Generators Acronyms And Glossary REFERRING TO LINES GMN GMS

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22

P V 50HZ #CONN #DPP

GE.VO.360/325.SS+0_all

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

POWER ENGINEERING KVA 50 HZ rpm

The GRW Series Designed for rental businesses POWER FOR RENT

Standby Amper VOLTAGE

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

TECHNICAL SPECIFICATIONS

Large autonomy Safety Ease of handling Silent. 18,0/14,4 20,0/16,0 Yanmar 4TNE88PG. 18,5/14,8 19,6/15,7 Deutz F3M 1011 F

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Standby Amper VOLTAGE

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

Power Factor Factor Cos = 0.8. Prime Power Standby Power Rated Current Fuel Consumption (PRP) (ESP) Amps

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

CGT Stamford UCI 274 E1

Standby Amper VOLTAGE

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

MPL series S MPL 15S MPL 22S. max. power 13,1 kva. max. power 22 kva GENERATORS. Standard version

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Proud To Be Manufactured- IN THE UK

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A

WITHSTANDING THE ELEMENTS

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Technical Data V DIESEL TCM500 (Open) LSA47.2M7 Optioanl: Stamford HCI544D. TCM500C (Silent) Tide TPA354S2. Alternator: Leroy-somer

GQW1400V. 1MWe TWINGEN in container 20 HC

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

ENGINE brand Yanmar Yanmar Yanmar Perkins Perkins model 3TNV76 3TNV88 4TNV88 403D-15G 404D-22G Cooling system Water Water Water Water Water

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

Standby KW. Standby KVA G15LSM 400/230* N/A

Power kva 11,5 12,4 Power kw 9,2 9,9 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

Technical specification

,QGXVWULDO#*HQVHW. 3RZHU#5DWLQJ 4833#USP283#+] 4;33#USP293#+] 3ULPH 27.5kVA, 22.0kW 32.5kVA, 25.9kW 6WDQGE\ 30.0kVA, 24.1kW 35.5kVA, 28.

Power kva 14,3 15,6 Power kw 11,4 12,5 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

Transcription:

MODEL GSW195-220Deutz. REF. PC5214_3St.00 Liquid cooling Diesel engine. Control panel protected by lockable door Internal residential muffler. Detachable central lifting point. Complete with engine and battery liquids. Oil draining facilities. Baseframe capable to be moved with hand pallet truck. Canopy made in zincted steel profiles with green power coated layer. Fully bunded / Completly sealed baseframe as option. Rental kit as option (POWER ON RENT). Single phase MODEL CODE PRIME POWER PRP EMERGENCY POWER LTP age Frequency (phases) Power factor Fuel capacity Autonomy (75/100% load PRP) Acoustic power Acoustic pressure at 7m Dimensions (LxWx) Weight DIESEL ENGINE Cooling system Speed Displacement Cyliders and disposition Aspiration Engine power PRP / LTP Fuel consumption (75/100% load) Specific consumption PRP Engine governor Electrical system (DC) ALTERNATOR Insulation Mechanical degree protection age regulation SU191TDA SU211TDA 183,0 (146,0) 205,0 (164,0) 194,0 (155,0) 220,0 (176,0) z Cos φ Litres h 11,5 / 8,7 10,2 / 7,7 LWA 94 94 db(a) 69 69 mm 3.x1.12x2.000 3.x1.12x2.000 kg 2.370 2.416 Deutz BF6M1013FCG1 BF6M1013FCG2 rpm 1.0 1.0 c.c. 7.1 7.1 n disp. 6 L 6 L kwm 158,8 / 175,8 175,8 / 193,8 l/h 29,5 / 39,3 33,3 / 44,4 g/kwh 208 212 12 12 Stamford UCI 274 UCI 274 G Class IP23 IP23 (%) (±1,5%) TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE Genereting set voltage (1 phase). Generating set current (1 phase). Manual control panel, mounted on the genset and complete of: analogue, control, protection of the generating set and sockets, protected through door with lockable handle. Start/stop selector switch with key (Glow plugs preheating function also included). Rev.00 (Ago2010) Pag. 1 of 3

OT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE TECNICAL CARACTERISTICS LISTED ARE NO AUTOMATIC CONTROL PANEL (AMF) Automatic control panel complete with digital control unit AC03 for monitoring, the generating set, through AC-03 control Remote starting availability. DC system disconnection switch. Acoustic. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. Circuit breaker protection:iii poles. Differential protection by means of the control through AC03 control Remote starting inhibition availability. Acoustic. AUTOMATIC CONTROL PANEL (AMF) Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete with digital control unit AC03 for monitoring, the generating set. IV poles - 325 A. IV poles - 325 A. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage. Genset protection: under/over voltage, overload, under/over battery voltage. Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) APM: PMG FOR STAMFORD ALTERNATOR + MX321 AVR. AFP: AUTOMATIC FUEL TRANSFER PUMP. DCC: DIFFERENT CANOPY COLOUR. EEG: ENGINE ELECTRONIC GOVERNOR. KRT: RENTAL KIT.. Complete of: GENSET SUPPLEMENTS Battery switch. Fuel filter water separator. Three way valve. Earth rod. Manual set folder External terminal board SKB: SOCKETS KIT B WIT 5 SOCKETS. PS: COOLANT PREEATING SYSTEM. 1 x V/63A 3P+N+T CE. 1 x V/32A 3P+N+T CE. 1 x V/16A 3P+N+T CE. KPR: KIT PREMIUM (Completly sealed baseframe + per liquid level in baseframe +Manual oil drain pump) Rev.00 (Ago2010) Pag. 2 of 3

CONTROL PANEL SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) MPF: MANUAL ANALOGUE CONTROL PANEL FULL OPTION. NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE TECNICAL CARACTERISTICS LISTED ARE N CONTROL PANEL SUPPLEMENTS SKB: SOCKETS KIT B WIT 5 SOCKETS. LOAD TRANSFER SWITC PANEL. Manual control panel with analogue, and Connections Protections meter with selector switch (3 phases). Frequency meter. Ammeter with selector switch (3 phases). Fuel level indicator. Oil pressure indicator. Engine temperature indicator. Start/stop selector switch with key (single key system) Engine protection unit: low fuel level, low pressure oil, high engine temperature, battery charger failure. 1 x V/63A 3P+N+T CE. 1 x V/32A 3P+N+T CE. 1 x V/16A 3P+N+T CE. IV poles - 325 A. ETB: EXTERNAL TERMINAL BOARD. eavy duty cupper bars of easy external power cables connection. RSS: REMOTE START/STOP. Only for MCP TIF: IV POLES CIRCUIT BREAKER INSTEAD OF III POLES. Load transfer switch panel built in a metal cabinet and supplied loose from the genset. STR: SITE TRAILER. Single axle. battery charger failure. Power cables connection to terminals board (internal). Terminals board for power cables connection (Genset-Mains-Load). Contactors mechanically and electrically interlocked. IV poles - 325 A. Note: Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. GSB: GALVANIZED SKIDS. eavy duty galvanized skid to be installed under the genset. Easily transportable with fork lift. RCG: REMOTE CONTROL BY GSM KIT (kit for genset management and control by remote PC; comunication available by means of RS232 directly to PC or through GSM modem). Others remote monitoring system under request. These kits are only available on the automatic versions. RTR: ROAD TRAILER (only for Spanish terrritories). Single axle. Rev.00 (Ago2010) Pag. 3 of 3

MODEL GSW195-220Deutz. REF. PC5214_3Me.00 Liquid cooling Diesel engine. Control panel protected by lockable door Internal residential muffler. Detachable central lifting point. Complete with engine and battery liquids. Oil draining facilities. Baseframe capable to be moved with hand pallet truck. Canopy made in zincted steel profiles with green power coated layer. Fully bunded / Completly sealed baseframe as option. Rental kit as option (POWER ON RENT). MODEL CODE PRIME POWER PRP EMERGENCY POWER LTP age Frequency (phases) Power factor Fuel capacity Autonomy (75/100% load PRP) Acoustic power Acoustic pressure at 7m Dimensions (LxWx) Weight DIESEL ENGINE Cooling system Speed Displacement Cyliders and disposition Aspiration Engine power PRP / LTP Fuel consumption (75/100% load) Specific consumption PRP Engine governor Electrical system (DC) ALTERNATOR Insulation Mechanical degree protection age regulation z Cos φ Litres h LWA db(a) mm kg Deutz rpm c.c. n disp. kwm l/h g/kwh MeccAlte Class (%) SU191TDA SU211TDA 183,4 (146,7) 203,7 (163,0) 196,0 (156,8) 220,0 (176,0) 11,5 / 8,7 10,2 / 7,7 94 94 68 68 3.x1.2x1.890 3.x1.2x1.890 2.300 2.3 BF6M1013FCG1 BF6M1013FCG2 1.0 1.0 7.1 7.1 6 L 6 L 158,8 / 175,8 175,8 / 193,8 29,5 / 39,3 33,3 / 44,4 208 212 12 12 ECP 38 1S ECP 38 2S IP21 IP21 (±1,5%) TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE Genereting set voltage (1 phase). Generating set current (1 phase). Manual control panel, mounted on the genset and complete of: analogue, control, protection of the generating set and sockets, protected through door with lockable handle. Start/stop selector switch with key (Glow plugs preheating function also included). Rev.00 (Ago2010) Pag. 1 of 3

INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE TECNICAL CARACTERISTICS LISTED ARE NOT I AUTOMATIC CONTROL PAN NEL (AMF) Automatic control panel complete with digital control unit AC03 for monitoring, the generating set, through AC-03 control AUTOMATIC CONTROL PANEL (AMF) Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete with digital control unit AC03 for monitoring, the generating set. Remote starting availability. DC system disconnection switch. Acoustic. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. Differential protection by means of the control through AC03 control Remote starting inhibition availability. Acoustic. IV poles - 325 A. IV poles - A. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage. Genset protection: under/over voltage, overload, under/over battery voltage. Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) AFP: AUTOMATIC FUEL TRANSFER PUMP. DCC: DIFFERENT CANOPY COLOUR. EEG: ENGINE ELECTRONIC GOVERNOR. KRT: RENTAL KIT.. Complete of: GENSET SUPPLEMENTS Battery switch. Fuel filter water separator. Three way valve. Earth rod. Manual set folder External terminal board SKB: SOCKETS KIT B WIT 5 SOCKETS. 1 x V/63A 3P+N+T CE. 1 x V/32A 3P+N+T CE. 1 x V/16A 3P+N+T CE. PS: COOLANT PREEATING SYSTEM. KPR: KIT PREMIUM (Completly sealed baseframe + proof canopy + per liquid level in baseframe +Manual oil drain pump) Rev.00 (Ago2010) Pag. 2 of 3

CONTROL PANEL SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) MPF: MANUAL ANALOGUE CONTROL PANEL FULL OPTION. NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE TECNICAL CARACTERISTICS LISTED ARE N CONTROL PANEL SUPPLEMENTS LOAD TRANSFER SWITC PANEL. Manual control panel with analogue, and SKB: SOCKETS KIT B WIT 5 SOCKETS. Connections meter with selector switch (3 phases). Frequency meter. Ammeter with selector switch (3 phases). Fuel level indicator. Oil pressure indicator. Engine temperature indicator. Start/stop selector switch with key (single key system) ETB: EXTERNAL TERMINAL BOARD. eavy duty cupper bars of easy external power cables connection. RSS: REMOTE START/STOP. Only for MCP TIF: IV POLES CIRCUIT BREAKER INSTEAD OF III POLES. Load transfer switch panel built in a metal cabinet and supplied loose from the genset. STR: SITE TRAILER. Single axle. Protections battery charger failure. Engine protection unit: low fuel level, low pressure oil, high engine temperature, battery charger failure. Power cables connection to terminals board (internal). 1 x V/63A 3P+N+T CE. 1 x V/32A 3P+N+T CE. 1 x V/16A 3P+N+T CE. IV poles - 325 A. IV poles - A. Terminals board for power cables connection (Genset-Mains-Load). Contactors mechanically and electrically interlocked. GSB: GALVANIZED SKIDS. eavy duty galvanized skid to be installed under the genset. Easily transportable with fork lift. Note: Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. RCG: REMOTE CONTROL BY GSM KIT (kit for genset management and control by remote PC; comunication available by means of RS232 directly to PC or through GSM modem). Others remote monitoring system under request. These kits are only available on the automatic versions. RTR: ROAD TRAILER (only for Spanish terrritories). Single axle. Rev.00 (Ago2010) Pag. 3 of 3