MODEL GSW195-220Deutz. REF. PC5214_3St.00 Liquid cooling Diesel engine. Control panel protected by lockable door Internal residential muffler. Detachable central lifting point. Complete with engine and battery liquids. Oil draining facilities. Baseframe capable to be moved with hand pallet truck. Canopy made in zincted steel profiles with green power coated layer. Fully bunded / Completly sealed baseframe as option. Rental kit as option (POWER ON RENT). Single phase MODEL CODE PRIME POWER PRP EMERGENCY POWER LTP age Frequency (phases) Power factor Fuel capacity Autonomy (75/100% load PRP) Acoustic power Acoustic pressure at 7m Dimensions (LxWx) Weight DIESEL ENGINE Cooling system Speed Displacement Cyliders and disposition Aspiration Engine power PRP / LTP Fuel consumption (75/100% load) Specific consumption PRP Engine governor Electrical system (DC) ALTERNATOR Insulation Mechanical degree protection age regulation SU191TDA SU211TDA 183,0 (146,0) 205,0 (164,0) 194,0 (155,0) 220,0 (176,0) z Cos φ Litres h 11,5 / 8,7 10,2 / 7,7 LWA 94 94 db(a) 69 69 mm 3.x1.12x2.000 3.x1.12x2.000 kg 2.370 2.416 Deutz BF6M1013FCG1 BF6M1013FCG2 rpm 1.0 1.0 c.c. 7.1 7.1 n disp. 6 L 6 L kwm 158,8 / 175,8 175,8 / 193,8 l/h 29,5 / 39,3 33,3 / 44,4 g/kwh 208 212 12 12 Stamford UCI 274 UCI 274 G Class IP23 IP23 (%) (±1,5%) TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE Genereting set voltage (1 phase). Generating set current (1 phase). Manual control panel, mounted on the genset and complete of: analogue, control, protection of the generating set and sockets, protected through door with lockable handle. Start/stop selector switch with key (Glow plugs preheating function also included). Rev.00 (Ago2010) Pag. 1 of 3
OT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE TECNICAL CARACTERISTICS LISTED ARE NO AUTOMATIC CONTROL PANEL (AMF) Automatic control panel complete with digital control unit AC03 for monitoring, the generating set, through AC-03 control Remote starting availability. DC system disconnection switch. Acoustic. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. Circuit breaker protection:iii poles. Differential protection by means of the control through AC03 control Remote starting inhibition availability. Acoustic. AUTOMATIC CONTROL PANEL (AMF) Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete with digital control unit AC03 for monitoring, the generating set. IV poles - 325 A. IV poles - 325 A. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage. Genset protection: under/over voltage, overload, under/over battery voltage. Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) APM: PMG FOR STAMFORD ALTERNATOR + MX321 AVR. AFP: AUTOMATIC FUEL TRANSFER PUMP. DCC: DIFFERENT CANOPY COLOUR. EEG: ENGINE ELECTRONIC GOVERNOR. KRT: RENTAL KIT.. Complete of: GENSET SUPPLEMENTS Battery switch. Fuel filter water separator. Three way valve. Earth rod. Manual set folder External terminal board SKB: SOCKETS KIT B WIT 5 SOCKETS. PS: COOLANT PREEATING SYSTEM. 1 x V/63A 3P+N+T CE. 1 x V/32A 3P+N+T CE. 1 x V/16A 3P+N+T CE. KPR: KIT PREMIUM (Completly sealed baseframe + per liquid level in baseframe +Manual oil drain pump) Rev.00 (Ago2010) Pag. 2 of 3
CONTROL PANEL SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) MPF: MANUAL ANALOGUE CONTROL PANEL FULL OPTION. NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE TECNICAL CARACTERISTICS LISTED ARE N CONTROL PANEL SUPPLEMENTS SKB: SOCKETS KIT B WIT 5 SOCKETS. LOAD TRANSFER SWITC PANEL. Manual control panel with analogue, and Connections Protections meter with selector switch (3 phases). Frequency meter. Ammeter with selector switch (3 phases). Fuel level indicator. Oil pressure indicator. Engine temperature indicator. Start/stop selector switch with key (single key system) Engine protection unit: low fuel level, low pressure oil, high engine temperature, battery charger failure. 1 x V/63A 3P+N+T CE. 1 x V/32A 3P+N+T CE. 1 x V/16A 3P+N+T CE. IV poles - 325 A. ETB: EXTERNAL TERMINAL BOARD. eavy duty cupper bars of easy external power cables connection. RSS: REMOTE START/STOP. Only for MCP TIF: IV POLES CIRCUIT BREAKER INSTEAD OF III POLES. Load transfer switch panel built in a metal cabinet and supplied loose from the genset. STR: SITE TRAILER. Single axle. battery charger failure. Power cables connection to terminals board (internal). Terminals board for power cables connection (Genset-Mains-Load). Contactors mechanically and electrically interlocked. IV poles - 325 A. Note: Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. GSB: GALVANIZED SKIDS. eavy duty galvanized skid to be installed under the genset. Easily transportable with fork lift. RCG: REMOTE CONTROL BY GSM KIT (kit for genset management and control by remote PC; comunication available by means of RS232 directly to PC or through GSM modem). Others remote monitoring system under request. These kits are only available on the automatic versions. RTR: ROAD TRAILER (only for Spanish terrritories). Single axle. Rev.00 (Ago2010) Pag. 3 of 3
MODEL GSW195-220Deutz. REF. PC5214_3Me.00 Liquid cooling Diesel engine. Control panel protected by lockable door Internal residential muffler. Detachable central lifting point. Complete with engine and battery liquids. Oil draining facilities. Baseframe capable to be moved with hand pallet truck. Canopy made in zincted steel profiles with green power coated layer. Fully bunded / Completly sealed baseframe as option. Rental kit as option (POWER ON RENT). MODEL CODE PRIME POWER PRP EMERGENCY POWER LTP age Frequency (phases) Power factor Fuel capacity Autonomy (75/100% load PRP) Acoustic power Acoustic pressure at 7m Dimensions (LxWx) Weight DIESEL ENGINE Cooling system Speed Displacement Cyliders and disposition Aspiration Engine power PRP / LTP Fuel consumption (75/100% load) Specific consumption PRP Engine governor Electrical system (DC) ALTERNATOR Insulation Mechanical degree protection age regulation z Cos φ Litres h LWA db(a) mm kg Deutz rpm c.c. n disp. kwm l/h g/kwh MeccAlte Class (%) SU191TDA SU211TDA 183,4 (146,7) 203,7 (163,0) 196,0 (156,8) 220,0 (176,0) 11,5 / 8,7 10,2 / 7,7 94 94 68 68 3.x1.2x1.890 3.x1.2x1.890 2.300 2.3 BF6M1013FCG1 BF6M1013FCG2 1.0 1.0 7.1 7.1 6 L 6 L 158,8 / 175,8 175,8 / 193,8 29,5 / 39,3 33,3 / 44,4 208 212 12 12 ECP 38 1S ECP 38 2S IP21 IP21 (±1,5%) TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE Genereting set voltage (1 phase). Generating set current (1 phase). Manual control panel, mounted on the genset and complete of: analogue, control, protection of the generating set and sockets, protected through door with lockable handle. Start/stop selector switch with key (Glow plugs preheating function also included). Rev.00 (Ago2010) Pag. 1 of 3
INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE TECNICAL CARACTERISTICS LISTED ARE NOT I AUTOMATIC CONTROL PAN NEL (AMF) Automatic control panel complete with digital control unit AC03 for monitoring, the generating set, through AC-03 control AUTOMATIC CONTROL PANEL (AMF) Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete with digital control unit AC03 for monitoring, the generating set. Remote starting availability. DC system disconnection switch. Acoustic. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. Differential protection by means of the control through AC03 control Remote starting inhibition availability. Acoustic. IV poles - 325 A. IV poles - A. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage. Genset protection: under/over voltage, overload, under/over battery voltage. Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) AFP: AUTOMATIC FUEL TRANSFER PUMP. DCC: DIFFERENT CANOPY COLOUR. EEG: ENGINE ELECTRONIC GOVERNOR. KRT: RENTAL KIT.. Complete of: GENSET SUPPLEMENTS Battery switch. Fuel filter water separator. Three way valve. Earth rod. Manual set folder External terminal board SKB: SOCKETS KIT B WIT 5 SOCKETS. 1 x V/63A 3P+N+T CE. 1 x V/32A 3P+N+T CE. 1 x V/16A 3P+N+T CE. PS: COOLANT PREEATING SYSTEM. KPR: KIT PREMIUM (Completly sealed baseframe + proof canopy + per liquid level in baseframe +Manual oil drain pump) Rev.00 (Ago2010) Pag. 2 of 3
CONTROL PANEL SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) MPF: MANUAL ANALOGUE CONTROL PANEL FULL OPTION. NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE TECNICAL CARACTERISTICS LISTED ARE N CONTROL PANEL SUPPLEMENTS LOAD TRANSFER SWITC PANEL. Manual control panel with analogue, and SKB: SOCKETS KIT B WIT 5 SOCKETS. Connections meter with selector switch (3 phases). Frequency meter. Ammeter with selector switch (3 phases). Fuel level indicator. Oil pressure indicator. Engine temperature indicator. Start/stop selector switch with key (single key system) ETB: EXTERNAL TERMINAL BOARD. eavy duty cupper bars of easy external power cables connection. RSS: REMOTE START/STOP. Only for MCP TIF: IV POLES CIRCUIT BREAKER INSTEAD OF III POLES. Load transfer switch panel built in a metal cabinet and supplied loose from the genset. STR: SITE TRAILER. Single axle. Protections battery charger failure. Engine protection unit: low fuel level, low pressure oil, high engine temperature, battery charger failure. Power cables connection to terminals board (internal). 1 x V/63A 3P+N+T CE. 1 x V/32A 3P+N+T CE. 1 x V/16A 3P+N+T CE. IV poles - 325 A. IV poles - A. Terminals board for power cables connection (Genset-Mains-Load). Contactors mechanically and electrically interlocked. GSB: GALVANIZED SKIDS. eavy duty galvanized skid to be installed under the genset. Easily transportable with fork lift. Note: Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. RCG: REMOTE CONTROL BY GSM KIT (kit for genset management and control by remote PC; comunication available by means of RS232 directly to PC or through GSM modem). Others remote monitoring system under request. These kits are only available on the automatic versions. RTR: ROAD TRAILER (only for Spanish terrritories). Single axle. Rev.00 (Ago2010) Pag. 3 of 3