GB INSTALLATION MANUAL

Similar documents
TECHNICAL DATA HYDRAULIC UNIT

Oil-hydraulic operator for swinging gates

INSPECTIONS AND MAINTENANCE

CHECKING AND MAINTENANCE:

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

INSTALLATION MANUAL GB

DRIVE 700 OVERALL DIMENSIONS

NYOTA 115. Electro-mechanical sliding gate operator. Instruction manual

Instructions manual. Below ground oil-hydraulic operator for swinging gates. pages 17-32

GB Instructions Manual

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

BAYT 980. Oil-hydraulic Road Traffic Barrier. BAYT 980 painted version BAYT 980 stainless steel version inox

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

1-24. Oil-hydraulic. Oil-hydraulic road barrier for traffic control from 3 to 8 metres

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

I - Libretto di istruzioni GB - Instructions manual F - Notices de montage

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

SWING GATE OPENERS 24V DC GEAR MOTOR

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

a p prove d ELECTROMECHANICAL SLIDING GATE OPENER

Automation Swing Gate Opener

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF:

Typical Installation Schematic

ARACHNE 230V 24V- 12V

Type of installation. external motor. underground motor. Leaf max length (m) Leaf max length (m) Max leaf weight (kg) V V V

FITTING AND CONNECTION INSTRUCTIONS

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

TITANO 400V SLIDING GATE OPENER

IMPORTANT NOTICE FOR THE INSTALLER

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

INSTALLATION MANUAL ENGLISH ALPHA 200 ALPHA 330. L C (stroke) 960 mm 1160 mm

BISON 20 OM BISON 25 OTI

Automation systems for swing gates hydraulic

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

Istruzioni, instructions. Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

SWING GATE OPENERS 24V DC GEAR MOTOR

Instruction Manual for the. E-SL 450 Series

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

INSTRUCTIONS FOR INSTALLATION

FEATURES AND SPECIFICATIONS

Installing the gate post bracket with the cardboard arm template

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

PERSA 400 USER S AND INSTALLER S MANUAL V1.0 REV. 10/2016

HÖRMANN DSA 100 DSA 100 L DSA 200 DSA 200L. page 1

Installation Manual. Swing Gate System. Leading the way...

Operating Instructions Type MPT 53

access

Max. stand-by power without accessories Use frequency 100% Max leaf width Motor Motor powered at 36V with encoder Max.

Installation Instructions

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

VEHICLE AND PEDESTRIAN CONTROL

In-Head Automatic Swing Door Operator DORMA. ED 200i

BARRY BARRIER GATE AUTOMATION

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Automations for garage doors and rolling shutters

Ditec PWR Automation system for swing gates with wings up to 5 metres

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

CAUTION CM-SE CM-S21 CM-S41

INSTALLATION MANUAL (cod )

Installing the gate post bracket with the cardboard arm template

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

E R A I GATE AUTOMATION DIVISION

USE AND MAINTENANCE MANUAL

Sectional And Tilting Door Opener

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control

Swing Gate Kits AUTOMATIC GATE KITS & ACCESSORIES SECURING GATES SINCE Control Cards. Accessories 2017 / Gate & Door Controls Catalogue

Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application

3. Operating instructions: Minor 200

VALVES WITH SA03 ELECTRIC ACTUATOR

contents Installation Maintenance DOOR OPERATOR SLIDING-1300/2100 Installation and Operating Manual DoorHan, 2012

Electromechanical gear motor for sliding gates ACHILLES

VERG 24V BARRIER. English

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

Automatic concealed bollards 275 H600 and 275 H800 with pit

Ditec PWR50H/HV/HR Automation for swing gates

Table of Contents. General Safety Preparation for Installation Parts List Optional Accessories Part List... 5

kinggates collection

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

Installing instruction Power-restraining FB33 March 2005

»»»»»»»»» FADINI is a reality today, that finds its place among the main players in the gate automation production and business.

RCEL005 / RCEL

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

AgriWheel Single Gate Kit Low Voltage & Solar. Installation & Operating Instructions

Hand Pallet Truck NC. Operation Manual

HYDRAULIC SWING GATE OPENER

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

C-SERIES S-SERIES. Metric Machine Screw Jacks EMA LINEAR ACTUATORS

PY600AC Sliding Gate Opener User Manual

MAXIMA MOTORISED LOCKS

F01 Electric Actuators

50 TONNE HYDRAULIC PRESS MODEL NO: CSA50FP

Transcription:

GB INSTALLATION MANUAL

MEC 800 SPECIAL OIL-HYDRAULIC OPERATOR FOR SWINGING GATES. EXTERNAL APPLICATION. ESSENTIAL COMPONENTS TO FIT THE OPERATOR TO A GATE LEAF FIXING BOLT FLEXIBLE TUBE 0.5 meter STRAIGHT COUPLING 1/4 G 4 - WAY PIPE CONNECTING BLOCK ELBOW JOINT 1/4 G REAR END BLOCK REAR FIXING FORK SELF LOCKING NUT OIL FUNNEL REAR BRACKET AND FIXING HOLE OIL LEVEL SIGHT GLASS RED BLUE RED YELLOW/GREEN 6 - WAY PIPE CONNECTING BLOCK COPPER PIPE Ø 8 ESTRU PIC. 1 RED BLUE RED YELLOW/GREEN CYCLE 3 - INTERMITTENT PIC. 2 2

PISTON 1 RETAINING CIRCLIP COVER PLUG BALL BEARING FIXING COVER TIE ROD COVER. C PROFILE FRONT FIXING BRACKET WITH PIN SPECIAL NUT PISTON SHAFT PISTON HEAD PISTON PISTON SLEEVE SLEEVE TIE ROD PIC. 3 - Oil-Hydraulic actuator. Assembly drawing PISTON 2 700/80 VENTIL CYCLE 3 - INTERMITTENT Drive 700 Estru (Pic. 1) is an electro-hydraulic motor pump unit fitted with bi-directional gate locking device, suitable for single applications when the gate involved is not particularly large and only one actuator Mec 800 Special is required. Being quite compact, this unit can be installed either close to the gate post or recessed in a brick pier by means of a galvanized enclosure which can be supplied on request. Very precise component parts and the special oil which is used in the hydraulic circuit make it extremely reliable. It is made up of a valve block, oil reservoir, top cover and a lockable door which gives access to the electric cable and all the electrical connections. A sight glass indicates oil level and a funnel is incorporated for filling. Adjustable pressure valves can be set to the right amount of force required to safely operate a gate open and close, while a release valve can override the locking device and allows manual operation of the system in an emergency situation or power failure. Drive 700 Estru can work to its utmost provided that is respected the recommended duty cycle, that is S3 intermittent service. Mec 700/80 Ventil (Pic. 2) is a very strong motor pump unit. As the above described unit it is fitted with bi-directional gate locking device, but the motor is air cooled and the oil reservoir has a greater capacity. The adjustable pressure valves and the release valve are easy to reach for setting operations. The special oil ensures proper functioning within a considerably wide range of temperature from -20 C to +80 C. An enclosure is available on request to protect the unit from weather conditions or accidents. The enclosure is designed to provide enough ventilation and is fitted with a lockable door for security reasons. It can be fixed close to the gate post or recessed where a brick pier exists. The great advantage of this unit is the possibility of extra oil reservoir to operate two actuators Mec 800 Special per gate, with very large and heavy gates. Designed for heavy duty applications, S3 duty cycle, motor direction easy to reverse. 3

COVER TIE RODS COVER/END PLUG HEXAGONAL NUT PLUG PIC. 4 B 130 A It is important that the gate hinges are close to the inside edge of the gate post. FIXED TO THE GROUND OPEN GATE 140 B A PIC. 5 - INSIDE VIEW D 80 FIXED TO THE GROUND CLOSED GATE 760 140 280 A IN CLOSED GATE BALL BEARING FRONT FIXING 130 B 80 D THE SUM OF A+B MUST TOTAL PISTON STROKE THREADED NUT TO ADJUST FRONT FIXING PISTON SHAFT 95 IN OPEN GATE SPECIAL - 280 mm DRWG. No. 2432 REAR BLOCK C/W BRACKET ALLOWING ROTATION OF THE GATE PIC. 6 PIC. 7 4

Instructions to follow to fit MEC 800 to a double swinging gate. It is recommended to respect all the steps described in this manual to achieve a perfectly working installation of the system. Before installing MEC 800 special it is important to check the structure of the gate and make sure that it is adequate to take the actuator, there must be no problems at all with the gate frame, which must be strong and robust to be electrically operated. It is recommended to strengthen and fix all the parts that look weak, or worn out, eliminate any friction of the gate against the gate post or pavement (check the hinges, the gate must be very smooth). The actuator is mounted to the gate by specially designed plates, one to the gate and one to the gate post (Pic. 5). MEC 800 is very strong and powerful. The thrust power that it can develop is high and safe. The motor pump unit is fitted with adjustable pressure valves. It is entirely made of steel and pressure cast aluminium, the temperature range it can safely bear is -20 C +80 C (Pic. 7). Installation: remove the anodized aluminium cover by unscrewing the two hexagonal nuts in the front cover plug (see pic. 4). Pull the cover horizontally and lay bare the cylinder, piston shaft and ball bearing front fixing. The fitting of the rear fixing plate to the gate post or brick pier can be either by welding, with the use of a square plate as in the picture, or by embedding. Anchor plates are to be used to secure the actuator plate into the concrete setting. Fixing geometry, ie. distances between hinge centre line of the gate and back fixing centre line of the actuator, are provided in pictures 5 and 6, on page 4, and pictures 21 to 23 on page 9. These are for long stroke braking actuators. Follow which applies. Make sure that the distances A and B are A = 140 mm and B = 130 mm respectively measured from the gate hinge centre line to back fixing centre line. This ensures smooth and even movements of the gate. Distance D is 80 mm from the centre line of the hole in the front fixing ball to the centre line of the gate plate (pic. 6). (Distances to be referred to only with MEC 800 actuators, 280 mm stroke). Before the square reinforcement plate is finally fixed to the gate, make some tests, the ball bearing head fully screwed in, allowing the piston to reach the very limit of the permitted stroke. Operate the gate manually to open and close. Try a second time with aluminium protection cover fitted. Once satisfied that the fixing distances are all right, remove the cover and weld the plate fully as shown in pictures 5 and 8. BALL BEARING HEAD FULLY SCREWED IN PROTECT THE SHAFT WHILE WELDING FIXING PLATE PIC. 8 Fix the front fixing plates and swing the actuator on to it, the piston shaft must be all out and the thread of ball bearing head all in, ie. not visible on the outside. The gate fully closed against its ground stop. A spirit level will tell if the actuator is perfectly straight (Pic. 5-8). After completing the fixing operations of the plates, unscrew the ball bearing head 5 or 6 mm approximately and tighten the nut to lock it in the correct position. This ensures the correct position of the gate on the closed gate stop (Pic. 9) FIXING PLATE PIC. 9 5 or 6 mm 5

OPEN FLEXIBLE TUBE OIL-HYDRAULIC ACTUATOR MEC 800 SPECIAL 4 - WAY BLOCK COPPER PIPES CLOSING CLOSED GATE FIXED TO THE GROUND PIC. 10 OPEN GATE FIXED TO THE GROUND COPPER PIPE ø 8 PIC. 11 NUT 3 SPIGOT ESTRU POWER OIL PIC. 12 Pipe layout. Before proceeding to the final fixing, lay the motor pump unit and the accessories (copper pipes, hoses, 4 -way block etc.) in the most suitable position to avoid any sharp bending of the copper pipes that connect the motor pump unit to the 4 - way block (Pic. 11). The flexible tubes are to be used to connect the pipe block to the actuator (Pic. 10). Keep a suitable distance to avoid rigidity of the hoses when the gates are opening. Do some manual test to prevent this from happening. Once satisfied that all distances are all right, insert the spigots, connect the pipes and hoses and carefully tigthen the nuts (Pic. 12). The above instructions apply only in cases where one actuator only is fitted to each gate leaf, along with one motor pump unit type Drive 700 Estru, depending on the gate weight, not suitable for very heavy duty applications (Pic. 11). FUNNEL The motor pump is not pre-oiled for transport reasons. Oil is to be filled on the installation site through the funnel incorporated under the top cover of the unit; pull the funnel 2 cm outwards and rotate the cup upwards. Fill with oil up to the level of the sight glass (Pic. 13) OIL LEVEL SIGHT GLASS In events like power failure it is necessary to overide the hydraulic circuit for manual operation. Turn anti-clockwise the release knob that is fitted between the two pressure valves (Pic. 13) It is possible to adjust the amount of force required to open and close the gates by setting the two safety pressure valves with a screwdriver as shown in Pic. 13. TYPE OF POWER OIL: FADINI A 15 By AGIP RELEASE FOR MANUAL OPERATIONS TURN ANTI-CLOCKWISE by one complete turn ADJUSTMENT MAX. PRESSURE VALVES PIC. 13 PLEASE NOTE: Valve A for open pressure must be driven 2 turns deeper than C close to get higher force and prevent the actuator from stopping during open cycle. 6

Very big and heavy gates can be fitted with two actuators type MEC 800 Special, which can meet high rating requirements very well. Fixing dimensions are the same as those quoted for one actuator, that is A + B = piston stroke; see Pic. 5-6 and 21 to 23. For double mounting see Pic. 14-16. FLEXIBLE PIPE 4 - WAY PIPE BLOCK 1 st ACTUATOR MEC 800 COPPER PIPE Fill the motor pump, bigger type, with FADINI A15 special oil by AGIP through the provided hole up to the level indicated by the sight glass. Pic. 15 Operate the equipment for a few cycles; part of the oil will flow from the motor pump into the two rams. Oil level in the motor pump will decrease. Bring it to the required level by adding about 1 liter more. This will keep the level below the sight glass, as recommended to prevent oil from overflowing because of the high back pressure during manual operations. LARGE ENCLOSURE FLEXIBLE PIPE 2 nd ACTUATOR MEC 800 6 - WAY PIPE BLOCK COPPER PIPE PUMP P16 PIC. 14 700/80 VENTIL WITH SUPPLEMENTARY OIL CONTAINERS BIG AND VERY HEAVY GATES 2 LITER CONTAINER FADINI A 15 OIL by AGIP OIL FILLING SIGHT GLASS MAX. OIL LEVEL CLOSED GATE FIXED TO THE GROUND MANUAL RELEASE one complete turn ANTI-CLOCKWISE OPEN GATE FIXED TO THE GROUND PIC. 15 PIC. 16 - Internal view: special application with two actuators MEC 800 7

FITTING THE ELECTRIC LOCK HORIZONTAL VERTICAL LOCK KEYS PIC. 17 OPEN GATE FIXED TO GROUND CLOSED GATE FIXED TO GROUND CLOSED GATE FIXED TO GROUND FOR LEAF TO OPEN 95 95 90 FOR LEAF TO OPEN 90 ELECTRIC LOCK PIC. 18 HORIZONTAL ELECTRIC LOCK LATCHING PLATE TO TAKE LATCHING BOLT MECHANICAL GATE LATCH PIC. 19 WITH MEC 800 SPECIAL MOUNTED WITH THE NON LOCKING TYPE MOTOR PUMP AN ELECTRIC LOCK IS REQUIRED One leaf gates. The electric lock is fitted to the gate horizontally; the catching plate is to be fixed to the brick pier or post. Two leaf gates. With double swinging gates, the electric lock can be fitted either horizontally or vertically. If mounted horizontally refer to pictures 17 and 19; please note the gate stop on the closed gate position. It has a special design to stop the gates and take the bolt of the mechanical latching device to secure the gates in the closed position. If mounted vertically, picture 20 refers. The gate stop to take the gates and the bolt of the lock. The gate leaf that is fitted with the electric lock must be operated with a 5 degree angle displacement to ensure that both leafs can complete their respective travels independently and prevent jamming on reaching the closed gate stop. It is very important that each gate leaf is fitted with gate stops in the fully open positions at the end of the permitted piston stroke. Pic. 18 PIC. 20 FIXED TO GROUND VERTICAL ELECTRIC LOCK 8

OTHER FIXING DISTANCES TO SUIT TYPE OF ACTUATOR PROVIDED 1 010 200 B 180 A 400 D CLOSED GATE 610 400 1 010 OPEN GATE 95 Adjust the shaft connection to a suitable distance so that there is a 10 mm clearance between the cover and the gate when the operator line is in the most critical position, ie. About 60 degrees inclined to the gate line. In most cases this distance can be considered to be included between 90 and 100 mm, but this distance is not applicable to all installations. PIC. 21 SPECIAL 400 mm DRWG. No. 2433 980 BRAKE BRAKE 20 30 BRAKE BRAKE 180 B 170 A 365 D CLOSED GATE A OPEN C CLOSE 20 315 30 615 365 980 OPEN GATE 95 Adjust the shaft connection to a suitable distance so that there is a 10 mm clearance between the cover and the gate when the operator line is in the most critical position, ie. About 60 degrees inclined to the gate line. In most cases this distance can be considered to be included between 90 and 100 mm, but this distance is not applicable to all installations. PIC. 22 SPECIAL 400 mm - Braking open/close DRWG. No. 2437 130 B 110 A 740 BRAKE BRAKE 20 30 250 80 D CLOSED GATE A OPEN C CLOSE BRAKE BRAKE 20 200 30 490 250 740 OPEN GATE 95 SPECIAL 280 mm - Braking open/close DRWG. No. 2436 PIC. 23 9

GENERAL DIAGRAM OF THE SYSTEM COMPLETE WITH ACCESSORIES 1-230 V/240 V - 50 Hz/60 Hz - line switch 2 - Control panel Elpro 13 CEI 3 - Radio receiver Astro 40 Aut 4 - Aerial Astro 40 Aut 4 5 5 - Flashing light Lapi 2 with protection cage 6-4 - way pipe connecting block 1 7 - Oil-hydraulic actutor MEC 800 Special 8 - Digital keypad Edi 60 outside the gate 2 3 7 9 - Electric lock 10 - Photocell receiver Difo 33 outside the gate 11 - Photocell light projector Difo 33 outside the gate 6 8 12 - Push buttons Pulin 3 "indoor" commanding unit table mount 13 - Oil-hydraulic motor pump MEC 700/80 Ventil enlarged oil capacity 14-6 - way pipe connecting block 10 7 15 - Gate stop close position 16 - Gate mechanical latch 17 - Gate stop open position 18 - Keyswitch Sech 15 inside the gate 12 13 14 17 18 19 - Double mount post, two holes - 1,20 mt 20 - Photocell light projector Difo 33 inside the gate 21 - Hand held transmitter Astro 40 Aut 22 - Photocell receiver Difo 33 inside the gate 19 20 PIC. 24 23 - Single mount post, one hole - 0,75 mt FLOW REGULATOR (Item code No. 7019). This is a device for controlling the speed of the piston and keeping it even. Depending on to which part it is fitted it can control either the open or close cycle or both. PIC. 25 10

s.n.c. FABBRICA AUTOMAZIONI CANCELLI fdsfh dsjkdj sfhdsjkf dsjhfkdjshfkj fdsfh dsjkdj sfhdsjkf dsjhfkdjshfkj fdsfh dsjkdj sfhdsjkf dsjhfkd jshfkj fdsfh dsjkdj sfhdsjkf dsjhfkdjshfkj djfkle cnodhfo ds dsfjkdos fejkdjfoiaf dkfjaorei dkdkllajaoiez cvnlahoie 7 6 FLOW REGULATOR OPEN 1 st MEC 800 SPECIAL CLOSE 9 11 13 FLOW REGULATOR OPEN 7 14 2 nd MEC 800 SPECIAL 15 16 17 CLOSE 21 22 23 Picture 26 refers to a double mount type installation to note how the flow regulators have been fitted to control the two actuators. In this specific case, the purpose is to slow down one gate leaf to ensure that it reaches the closed gate position after the other one. PIC. 26 There may be cases where the gates are peculiar and are mounted in the middle of the pillar, post or brick pier; or the gate surface line is aligned with the post horizontal line, or again where the hinges are particular either in the shape or fixing, mounting distances are always to be referred to the centre line of the gate vertical axis of rotation. At this stage the electrical connections to the electronic control box can be started. Follow the diagram in Pic. 28. Once the connections have been made, do the first switching test to make sure that the leaf delay time, the logic functions, and the motor run time are as required after setting DIP-SWITCH B No. 3 to automatic. If set to semiautomatic one pulse opens the gates, a second pulse is needed to close the gates. ALL THE EQUIPMENT MUST BE PROPERLY EARTHED If a non locking motor pump has been fitted, in events like power failure it is necessary to release the electric lock first by means of the provided key as shown in Pic. 13-15 and push the gates open by hand applying an even and progressively increasing force. Beyond 50 m distance the section of the mains cable must be 2.5 mm 2 DO THIS OPERATION ONCE THE FIRST RUNNING TEST HAS BEEN COMPLETED E IDENTIFICATION PLATE ELECTRICALLY OPERATED GATES IT IS IMPORTANT TO TIGHTEN NUT E USING PROPER TOOLS PIC. 27 This notice to warn people that they are in proximity of an automated area, therefore the plate must be fitted to the gate in a well visible place. 11

CONNECTION DIAGRAM FOR SWINGING GATES 13 exp 26 27 28 RADIO CONTROL PLUG-IN CARD SUPPORT 1 st CHANNEL TERMINALS FOR CONNECTIONS TO PUSH BUTTONS PULIN 3 24 V OUTPUT ON TO 0 THE DELAY IS OUT OF SERVICE MICROPROCESSOR 7 0 8 9 + + + DWELL TIME TIMER SWITCHES LEAF DELAY TIMER CLOSE MOTOR RUN OPEN & CLOSE TIME 1 AMP. FUSE 24 V OUTPUT TERMINALS 12-13 CAPACITORS FUSE 630 ma FLASHING LAMP 630 ma FUSE FUSE 5 AMPS B ON Should more pairs of photocells be required than the recommended quantity, fit an auxiliary transformer outside the control box. DIP-SWITCH 1 2 3 4 5 6 7 8 3 4 ON OFF = PHOTOCELLS 2 nd PAIR = Inside photocells N.C. contact If obstracted, they prevent the gates from opening reverse gate direction during close cycle 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 N.C. CONTACT PHOTOCELLS PEDESTRIAN MODE ONE PULSE OPENS ONE GATE LEAF ONLY COMMON OPEN SWITCH N.O. CONTACT CLOSE SWITCH N.O. CONTACT STOP SWITCH N.C. CONTACT RADIO CONTACT N.O. COMMON VOLTAGE OUTPUT ELECTRIC LOCK SUPPLY 7 8 24 V INDICATOR - 3 W max. Max permitted load: 24 V 2 pairs photocells OUTPUT A.C. 1 radio receiver SAFETY CONTACT N.C. COMMON 12,5µF M1 COMMON 12,5µF M2 ELECTRIC MOTORS SINGLE-PHASE 230 V FLASHING LAMP 25 W max. 230 V SINGLE-PHASE SUPPLY VOLTAGE NOTE WELL. For special applications, i.e. to switch on lights - cctv etc..., solid state relays are recommended to be used only. Standard relays would affect the micro-processor. PULSE TWICE CONSECUTIVELY TO OPEN BOTH GATE LEAFS ALL OPERATIONS OPEN, CLOSE AND REVERSE RADIO CONTACT NOTE WELL. This panel is tested to operate gates only through Fadini accessories. No guarantee for accessories of other make or special applications. LED No. 1 - It switches on when voltage is supplied Draw. No. 1643 P.C. BOARD 26 27 28 3 1 2 3 4 5 6 7 8 9 1011 12 13 3 4 5 6 CONNECTION TO THE PULIN 3 PUSH BUTTONS WITH STATUS INDICATION LEDS. COMMON OPEN N.O. CONTACT CLOSE N.O. CONTACT STOP N.C. CONTACT TERMINAL BOARD N.O. N.C. N.O. OPEN STOP CLOSE OPEN CLOSE STOP E. CONNECTIONS KEYSWITCH SECH 15 PIC. 28 PIC. 29 ELECTRICAL WIRING DIAGRAM OF THE ELECTRONIC PROGRAMMER Once the connections have been made, do the first switching tests through the control panel. Set the motor run timer so that the motor is allowed to run 4-5 seconds more than the gate run time to the stops open or close. Set the other timers to meet the site requirements. Set DIP switch B No. 3 to automatic (ON): on pulsing to 4-8 the gates must be operated as pre-set, ie. opening and only after the dwell time, closing. Adjust the times through the respective timers. (See No. 7, 8 and 9 draw. No. 1643). With DIP switch B No. 3 to semiautomatic (OFF) one pulse opens the gates, a second pulse to 5-8 is needed to close the gates. Any one pulse to 7-8 will open, close or reverse the gates independently from the operation being performed. It is recommended to carefully read the instructions in the control box to have all the functions performed correctly. The 6 LED on the P.C. board indicate the following: Led No. 1 It switches on when voltage is supplied. Led No. 2 Photocells. Normally on. It switches off when the photocells are obstructed. Led No. 3 Open - It switches on when the respective switch is activated. Led No. 4 Close - It switches on when the respective switch is activated. Led No. 5 Stop - Normally on. It switches off when the respective switch is activated. Led No. 6 Radio - It switches on whenever a pulse is given either from remote control, keyswitch or push buttons. 12

OIL-HYDRAULIC ACTUATOR LINEAR DISIGN OVERALL DIMENSIONS SPECIAL 85 25 110 25 85 85x85 740 7 STROKE 480 280 760 PIC. 30 TECHNICAL SPECIFICATIONS Oil-hydraulic actuator Shaft excursion speed...28s Piston stroke...280 mm Piston diametre...50 mm Shaft diametre...22 mm Max. thrust power. Open...390 Kg Max. Pulling power. Close...490 Kg Weight...5,5 Kg Dimensions (length x width x height)...840x85x110 mm ADJUSTMENT SCREW 0,5 metres ø 8 7018 - Flexible tube 0,5 mt 105 length. = 707 - Flexible tube ø 8, mt 4, Kg 1 ø 8 25 20 50 30 70 ø 8,5 20 ø 8,5 52 7019 - Flow regulator with joints 50 7038-6 - way pipe connecting block with joints 50 7013-4 - way pipe connecting bock with joints 840 OIL-HYDRAULIC ACTUATOR COMPLETE WITH COVER DRWG. No. 1108 13

OIL-HYDRAULIC MOTOR PUMP ESTRU 58 116 200 35 325 345 EARTH LIVE NEUTRAL LIVE 320 160 LOCKABLE COVER 116 136 156 TECHNICAL SPECIFICATIONS Type of power oil: Fadini A 15 By Agip PIC. 31 350 Electric motor Oil-hydraulic pump Power output...0,24 KW (0,33 HP) Pump flow rate P6...1,60 l/min. Supply voltage...230 V Mean working pressure...2mpa (20 bars) Frequency...50 Hz Max. pressure...4mpa (40 bars) Absorbed current...2 A Working temperature...-20 C +80 C Absorbed power...400 W Oil type...oil FADINI A 15 by AGIP Capacitor...12,5 µf Oil reservoir capacity...0,95 dm 3 Motor rotation speed...1 350 r.p.m. Weight of the assembly...8 Kg Intermittent service...s3 IP protection standards...ip 673 200 200 7070 - Enclosure for DRIVE 700 ESTRU galvanized, with lock. Duty cicle 28 sec. opening - 30 sec. stop - 28 sec. closing Time of one complete cycle...86s Complete cycles - Opening - Stop - Closing...No. 41/hour No. of cycles per year 8 hours service a day...no. 122 000 Drive 700 Estru is a motor pump unit, very compact to meet the most various space requirements. Voltage rating, frequency and number of revolutions of the electric motor can vary to meet the customer s requirements. The motor generates and transmits a rotary motion to the lobe pump, which displaces oil in the hydraulic circuit under constant pressure. The pump is designed as a most efficient unit which guarantees a perfect and silent performance of the system. Oil can reverse inside the circuit without any problem. The valve block is fitted with adjustable pressure valves that can be set to the gate weight so that a sufficient amount of power is transmitted to the actuator to safely open and close the gates. In the valve block are also fitted the release valve for manual operation in case of power failure, fittings for piping the system and fixing parts. The design, construction and component parts are such to guarantee this motor pump as a totally sealed unit, fully protected from water, dust and accidents. 14

OIL-HYDRAULIC MOTOR PUMP Electric motor SINGLE-PHASE Power output... 0,37 KW (0,5 HP) Supply voltage... 230 V Frequecy... 50 Hz Absorbed current... 2,4 A Absorbed power... 510 W Capacitor... 20 µf Motor rotation speed... 1 350 r.p.m. Intermittent service... S3 THREE-PHASE 0,37 KW (0,5 HP) 230/400 V 50 Hz 2,1/1,2 A 575 W 1 350 r.p.m. S1 700/80 VENTIL 7016 - Enclosure to suit the oil-hydraulic motor pump MEC 700/80 VENTIL 460 140 250 Oil-hydraulic pump Pump designation... P3 P6 P12 Flow rate... 0,85 l/min. 1,60 l/min. 3,10 l/min. Mean working pressure... 1MPa (10 bars) 2MPa (20 bars) Max. working pressure... 3MPa (30 bars) 4MPa (40 bars) Working temperature...-20 C +80 C Oil type... OIL FADINI A 15 by Agip Oil reservoir capacity... 2 dm 3 Motor pump static weight... 10 Kg IP protection standards... IP 54 Duty cycle 28 sec. opening - 30 sec. stop - 28 sec. closing. Time of one complete cycle...86 s Complete cycles - Opening - Stop - Closing...N. 41/hour No. of cycles per year 8 hours service a day...n. 122 000 Motor pump whit supplementary oil containers Pump designation... P16 Pump flow rate... 3,90 l/min. Mean working pressure... 2MPa (20 bars) Max. pump pressure... 4MPa (40 bars) Working temperature... -20 C +80 C Power oil type... OIL FADINI A 15 by Agip Motor pump static weight... 16 Kg IP protection standards... IP 54 Oil capacity... 4,5 liters Empty supplement capacity... 2,5 liters 2MPa (20 bars) 4MPa (40 bars) Duty cycle: 12 sec. opening - 30 sec. stop - 12 sec. closing Time of one complete cycle...54 s Complete cycles - Opening - Stop - Closign...N. 66/hour No. of cycles per year 8 hours service a day...n. 194 000 140 120 128 MANUAL RELEASE 120 10 ø 140 PIC. 32 10 116 215 160 56 132 217 405 EARTH Power oil type: Fadini A 15 By Agip EARTH 120 120 LIVE NEUTRAL LIVE 405 LIVE NEUTRAL LIVE MEC 700/80 Ventil is an oil-hydraulic motor pump fitted with the new lobe pump; this unit is capable of very quiet operations and can assure constant oil pressure at 40 bars, heavy duty. The air-cooled electric motor, 1 350 r.p.m., is designed to maintain the power at the required constant rate for heavy duty, right-hand/left-hand operations without variation in oil pressure rating. The motor and the pump are coupled together by means of an elastic joint that is fitted between the two rotation shafts. It provides an ideal shock mount to absorb the kickbacks of the electric motor when rotation is reversed in order to pressurize oil in the opposite direction either to the right or left of the hydraulic circuit. The valve block provides a fixing base to the whole assembly, ie. the motor and pump, and incorporates two safety pressure valves and a locking device in the shape of a cylindrical shuttle. The purpose of this device is to provide a hydraulic lock in the oil circuit both in the open and close directions. Between the two pressure valves is the manual release device. When the electric motor is switched off (stopped) the hydraulic circuit can be released so that the unit is set for manual operations. The valve block is also available in the option without locking device. The motor pump unit is set to either locking or non locking during assembling phase. There are three different types of lobe pumps, depending on the specific component parts that make up the pump assembly. The flow rate, ie. the amount of fluid that each pump can displace under pressure, can be varied to meet the application requirements. 15 PIC. 33 160 MANUAL RELEASE 205 160 525 460 250 Power oil type: Fadini A 15 By Agip 590 7025 - Enclosure to suit the motor pump unit with supplementary oil containers.

ESTRU OIL-HYDRAULIC MOTOR PUMP MOTOR 2 PHASE HP 700/80 VENTIL OIL-HYDRAULIC MOTOR PUMP MOTOR 2 PHASE HP Rev/min. Protection Standards IP 673 Working pressure max. 3 MPa (30 Bars) Rev/min. Protection Standards IP 54 Working pressure max. 3 MPa (30 Bars) 05-2004 Data sticker electric motor Data sticker electric motor WARNINGS - Perform a Risk Analysis befor every installation and resolve risks through the use of safety devices in compliance with EN 12445 and EN 12453 safety standards - Follow the istructions provided - Check that the information on the electric motor plate conforms to the distribution network - Dispose of all cardboard, nylon, polystyrene and other packaging with specialized waste disposal firms - If removing the actuator, do not cut the electric wires, but disconnect them from the terminal box by loosening the screws inside the junction box - Disconnect the mains switch before opening the electrical wire junction box cover - The whole automation should be earthed with the yellow/green wire - CUSTOMER GUARANTEE CERTIFICATE ON CUSTOMER S REQUEST We recommend reading the warning regulations, suggestions and observations in this booklet very carefully. Meccanica Fadini recommends the control panel ELPRO 13 CEI for installations in conformity to the existing safety standards. The electronic programmer ELPRO 13 incorporates and can provide all the functions which are required by the most demanding applications with swinging gates. In addition to the features of a conventional control box type Elpro 9 (drwg. 1310), the following requirements can be provided: stroke reversing pulse, pedestrian mode, stop in any gate position by holding down the remote control button. Among the added features and improvements of ELPRO 13, in conformity to the European safety standards, there is the mains rotary switch: it is fitted to the box cover and switches off the mains voltage whenever the cover is removed. 13 CEI CUT OFF MAINS SWITCH EUROPEAN MARK CERTIFYING CONFORMITY TO THE ESSENTIAL REQUIREMENTS OF THE STANDARDS 98/37/EC INSPECTIONS AND MAINTENANCE In order to ensure optimal system performance over time and so as to comply with current safety standards, it is necessary to follow the correct maintenance and monitoring procedures for the entire automation, electronic devices and wiring: - Oil-hydraulic automation: maintenance inspection around every 6 months - Electronic devices and safety systems: maintenance inspection monthly IMPORTANT WARNING NOTES - It is recommended to keep to the instructions here outlined -check the specifications on the motor sticker with your mains supply. - Dispose properly of the packaging materials such as cardboard, nylon, polystyrene etc. through specializing companies. - Switch off the mains power switch before removing the cover of the motor pump enclosure. - All the system must be earthed by using the yellow/green wire, marked by its specific symbol. - It is recommended to read the regulations, suggestions and remarks quoted in the booklet "Warnings". - Before removing the ram, make the oil flow back to the reservoir in the motor pump unit through the release system; should the motor pump be removed, too for service or maintenance, plug the pipe joints to prevent oil from coming out during transport. The growth of MECCANICA FADINI has always been based on the development of guaranteed products thanks to our TOTAL QUALITY CONTROL system which ensures constant quality standards, updated knowledge of the European Standards and compliance whit their requirements, in view of an ever increasing process of improvement. DECLARATION OF CONFORMITY GENERAL WARNINGS EN 12453, EN 12445 STANDARDS CEI EN 60204-1 STANDARDS WARRANTY CERTIFICATE ON THE CUSTOMER S REQUEST The CE mark certifies that the operator conforms to the essential requirements of the European Directive art. 10 CEE 73/23, in relation to the manufacturer s declaration for the supplied items, in compliance whit the body of the regulations ISO 9000 = UNI EN 29000. Automation in conformity to EN 12453, EN 12445 safety standards. the gate opener Made in Italy ECOLOGICAL RECYCLING AUTOMATIC GATE MANUFACTURERS s.n.c. Distributor s box The manufacturers reserve the right to change the products without any previous notice Via Mantova, 177/A - 37053 Cerea (Verona) Italy - Tel. +39 0442 330422 r.a. - Fax +39 0442 331054 - e-mail: info@fadini.net - www.fadini.net