SPEC SHEET. OmniReach FTTX Solutions. NEMA Fiber Demarcation Box (FDB) Features

Similar documents
SW1 Swivel 1U Patch Panel

SW1 Swivel 3U Patch Panel

Fiber Splice Panel Rack Mount User Manual

FL2000 Termination/Splice Panels User Manual

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

Connectorized Cables Category 2, 3, and 5

LSW Connector Module User Manual

LX2 High Density LGX 4U Patch Panel

LX2 High Density LGX 4U Patch Panel

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

12-Inch Hybrid Fiber Access Terminal Installation Instructions

Introduction to Fiber Cable Assemblies FiberDeep and Cable Assemblies

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

Enhanced Management Frame (EMF)

INSTALLATION INSTRUCTIONS

Optical Fiber Closure. Fuzzy Integral Closure for Optical Cable VSOF-RN402A VISSEM. Electronics Co., Ltd.

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

Section 1 COYOTE Closure Series

Swing-Out Style Fiber Distribution Units

Splice Trays. features and benefits. specifications. A LANscape. Solutions Product. Splice Capacity

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

Fiber Solutions for Access and Transport Networks

S123 v2 Fusion Splicers Hand-Held Clad Alignment Fusion Splicer

FITEL S178 Ver.2 Hand-held Core-Alignment Fusion Splicer

Eagle Mountain-Saginaw Independent School District REQUEST FOR COMPETITIVE SEALED PROPOSALS (RFCSP)

Fiber Cables & Hardware

OFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation

3000SC Fiber Optic Splice Closure

LightLink Fiber Optic Splice Trays

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

Opti-Guard Splice Enclosure

OFS Fitel LST1U-072/7 and LSTLW Instruction Sheet (LaserWave) Fiber Optic Comcode: Termination Shelf Installation

Universal Network Zone System Part Numbers: Z23U-****

Network Zone System Part Numbers: Z23N-***** Z23R-****

FiberGuide Fibre Management Systems

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

Tender for procurement of Passive Components of LAN & Wi-Fi and their installation. Corrigenda. Annexure/Clause For Read

All In One Fusion Splicer

Multilink s Family of Wall Mount Enclosures

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

MIC Plenum Cables, 2-24 Fibers

COYOTE Terminal Dome Closure 6.5" x 22"

Access your fiber assemblies in the front of the enclosure to your fiber splices via a rear door without disturbing the fiber.

FITEL S153A Ver.2 Hand-held Active Alignment Splicer

Centrix System. Features and Benefits

Z22C-** Preconfigured Network Zone System

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

Fi b e r Op t i c So l u t i o n s

Type 4 Panel Enclosures

8400 Series Fiber Distribution System

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

Network Zone System. Part Numbers: Z22N-****** Z22R-****

Interconnect Cable Simplex and Duplex

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

Data Center Solutions Entrance Facility Main Distribution Area Horizontal and Equipment Distribution Areas. 1st Edition

COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

DSX-1 Digital Signal Cross-Connect

NEMA-Rated Fiber Optic Wallmount Enclosure. Protects your fiber cabling in a damp environment.

VERTIV XTE 401 SERIES. Ordering Guide

Plug & Play AnyLAN Systems

New Product Bulletin. PowerCINCH The Modular Power Distribution and Motor Control Connection System for Machinery Applications

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

ezprep Gel-Free Loose Tube Gel-Free Loose Tube Cable (2.5mm)

COYOTE STP (Service Termination Point)

NetReach BUP Series Integrated Building Entrance Terminal Solution

COYOTE LCC (Low Count Closure)

COYOTE STP (Service Termination Point)

19 1HU Splicing and Front Patching Shelf

Mini5 1U Fixed Tray Fibre. Panels. Mini5 1U Sliding Tray Fibre. Panels.

Instructions for Use - Opt-X 1000i Enclosure

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

S Ingle Mode Fiber Patch Cord and Pigtail (SC/APC, LC/APC)

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice. 2-2 (440)

Instruction Sheet Simplex and Duplex. LightCrimp Plus LC. Fiber Optic Connector Kits Feb 2017 Rev E

High-Performance Industrial Emergency LED Lighting LHP & LHPR SERIES

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

P R O D U C T C AT A L O G T ALOG

1 GENERAL INFORMATION

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice 2-2

Indoor/Outdoor Cables Single-Armored, Plenum, Tight Buffered Distribution Indoor/Outdoor Cable

Detailed Specifications & Technical Data

ezspan ADSS Short Span All-Dielectric Self-Support Loose Tube Cable

fiber optic cable Outdoor Cables

ExpressLT Dry Dry Loose Tube Cable (2.5 mm)

Accessories. Introduction. Cable Hangers LINE PRODUCTS TRANSMISSION

FC/APC Patchcord FC/APC. Insertion Loss(Reference plug) Insertion Loss (Random mated) Return Loss

Section 1 COYOTE Closure Series

FOSC-400A4 INSTALLATION INSTRUCTION

The HP Series offers many advantages in an industrial environment

FIBER CONNECTOR SAFETY WARNINGS

RACK SYSTEMS Racks, Rack Enclosures, Cable Managers, Shelves & Accessories

accqpulse Velocity Profiler Sensor Installation Guide

Transcription:

ADC s OmniReach FTTX Solutions are the industry s first infrastructure solutions designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, OmniReach solutions simplify FTTX network installation, maintenance and management from the central office/headend to the outside plant. ADC s family of NEMA fiber demarcation products provides termination and splicing for fiber cables in environments requiring secure, low profile enclosures. Built with traditional ADC quality and durability, the products promise long service life in harsh environments and help ensure network reliability and flexibility. Features SPEC SHEET Designed to meet NEMA 250 - Type 12 (dust proof, drip proof) Wall mountable in harsh indoor and remote environments Quick installation and cable routing; reduces cost of installation and network maintenance time Accommodates top or bottom cable entry High density, aesthetically attractive design; features rounded, removable front door Space saving, dual fold design with locking, technician-friendly splice area and easy hand access to fiber connectors Separation of termination, splicing functions protects circuit integrity Multiple locking options, including separate lock on splice area; control access to critical parts of the wall box Uses familiar industry interfaces; ADC sliding adapter packs (six packs) with FC, SC, ST, LX.5 or LC connectors, provide high density with superior hand access Accommodates MicroVAMs for signal distribution, WDM and monitoring/test applications Ideal for ribbon splicing; supports stranded splicing

12- and 24-Position Termination side 24-position shown (12-position loaded with two sliding adapter packs) Splicing Side Cable and Panel Compression Fitting Location Grounding (top and bottom) Front View Strength Member Tie-off Location 9.00" (22.86 cm) Optional Splice Tray Shown 7.20" (18.29 cm Patch cord exit (location top and bottom) Sliding adapter pack for customer access Top View 5.49" (13.94 cm) 13.50" (34.29 cm) 2

48-Position Termination side Splicing side Compression Fitting Location (top and bottom) Front View 9.00" (22.86 cm) Cable and Panel Grounding Strength Member Tie-off Locations Patch Cord Exit (location top and bottom) Sliding Adapter Pack for Customer Access Optional Splice Trays Shown Top View Or Lock Available Or Lock Available 10.00" (25.40 cm) 6.34" (16.10 cm) 13.50" (34.29 cm) 3

72-Position Termination side Grounding Stud Splicing Side Optional Splice Trays Shown Cable and Panel Grounding Compression Fitting Location (top and bottom) Front View Strength Member Tie-off Locations 11.00" (27.94 cm) Grounding Stud Patch cord exit (location top and bottom) Sliding adapter pack for customer access Top View 12.80" (32.51 cm 5.69" (14.45 cm) 15.00" (38.10 cm) 4

96-Position Termination side Splicing Side Cable and Panel Grounding Compression Fitting Location (top and bottom) Front View Strength Member Tie-off Locations 11.00" (27.94 cm) Patch Cord Exit (location top and bottom) Sliding Adapter Pack for Customer Access Optional Splicetrays Shown Quarter Turn Latch Top View Quarter Turn Latch Quarter Turn Latch 16.10" (40.89 cm) 6.39" (16.23 cm) 15.00" (38.10 cm) 5

with Pigtails Catalog Number FDB- _S _S X 0 0 Box Size 1 12 fibers 2 24 fibers 4 48 fibers 7 72 fibers 9 96 fibers Adapter/Connector Type Multimode 9 SC 5 ST Y LX.5 6 LC Singlemode OR 2 FC ultra polish L FC with zirconia adapter 7 SC ultra polish N SC with zirconia adapter J SC angled polish 4 ST ultra polish P ST with zirconia adapter K E-2000 angled polish X LX.5 8 LC Pigtail or Adapter Type A Adapters only U 12-fiber stranded R 12-fiber ribbon 4 12-fiber Maxi-Strip (stranded) Number of 6packs loaded Strength Member Tie-offs 0 No strength member tie-offs included 1 1 strength member tie-off included Lock Options A Front lock 1, rear lock 2 B Front lock 2, rear lock 1 C Front lock 1, rear quarter turn D No front lock, rear lock 1 E No front lock, rear lock 2 F No front lock, rear quarter turn G Front lock 1, rear lock 1 Cable Clamps 0 No clamps included 1 1 clamp included 2 2 clamps included Splice Tray/Chip Style 0 None 2 Heat shrink fusion 3 Mechanical/ribbon 6

Preterminated with Multifiber Cable Catalog Number FDB- M 00 Box Size 1 12 fibers 2 24 fibers 4 48 fibers 7 72 fibers 9 96 fibers Adapter/Connector Type Multimode 9 SC 5 ST Y LX.5 6 LC Singlemode OR 2 FC ultra polish L FC with zirconia adapter 7 SC ultra polish N SC with zirconia adapter J SC angled polish 4 ST ultra polish P ST with zirconia adapter K E-2000 angled polish X LX.5 8 LC Cable Type Multimode C IFC stranded 62.5/125 Y IFC stranded (50/125) Singlemode OR A IFC stranded riser-rated F Plenum stranded G OSP single armor stranded H Indoor-outdoor stranded J OSP dielectric stranded K IFC stranded Maxi-Strip M IFC ribbon riser-rated T OSP dielectric ribbon L OSP armored ribbon Cable Size 1 12 2 24 3 36 4 48 7 72 9 96 A 144 Z 2x12 Y 2x24 X 2x36 W 2x48 Strength Member Tie-offs 0 No strength member tie-offs included 1 1 strength member tie-off included Lock Options A Front lock1, rear lock 2 B Front lock 2, rear lock 1 C Front lock 1, rear quarter turn D No front lock, rear lock 1 E No front lock, rear lock 2 F No front lock, rear quarter turn G Front lock 1, rear lock 1 Cable Exit Location U Up D Down Cable Clamps 0 No clamps included 1 1 clamp included 2 2 clamps included Cable Length (in meters) 7

SPEC SHEET Web Site: www.adc.com From North America, Call Toll Free: 1-800-366-3891 Outside of North America: +1-952-938-8080 Fax: +1-952-917-3237 For a listing of ADC s global sales office locations, please refer to our web site. ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer 1269044 8/05 Revision 2003, 2004, 2005 ADC Telecommunications, Inc. All Rights Reserved