Proportional pressure relief valve Types DBE(M) and DBE(M)E

Similar documents
Proportional pressure relief valve Types DBE(M) and DBE(M)E

Proportional pressure relief valve, pilot operated

Proportional pressure reducing valve of 3-way design Types 3DREP and 3DREPE

Proportional pressure reducing valve, pilot operated

Pressure reducing valve, pilot operated Type DR

Proportional pressure relief valve, pilot operated

Check valve cartridge Type M-SR

4-way directional servo valve Type 4WS.2E

2/2-way poppet valves with solenoid operation Type KSDER1

4/2- and 4/3-way proportional directional valves, direct actuated, without electrical position feedback Types 4WRA and 4WRAE

Double throttle check valve Type Z2FS 10

Proportional pressure reducing valve, pilot operated

Proportional pressure reducing valve, pilot operated. Type DRE(M) and DRE(M)E. Features. Contents. RE Edition: Replaces: 11.

Servo directional valve of 4-way design Type 4WS.2E

Electro-Proportional Pressure Reducing and Relieving Cartridge Valves

Proportional pressure reducing valve, pilot operated

4/2- and 4/3-way proportional directional valves, direct operated, without electrical position feedback, without/with integrated electronics (OBE)

Proportional pressure relief valve Type DBETRE

Proportional pressure reducing valve, pilot operated

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

29 160/ Proportional Pressure Relief Valve Model DBE, (Series 5X) Ordering Code DBE 5X Y G24 1/ PSI (350 bar)

Directional servo-valve of 4-way design

3-way Proportional pressure reducing valve, pilot operated

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

Proportional pressure reducing valve, 3-way variant, pilot operated

Directional servo-valve in 4-way design

Proportional pressure reducing valve of 3-way design

2-way proportional throttle valve for block installation

4-way directional servo-valve

RC /

Proportional pressure reducing valve, in 3-way version

Proportional flow control valve, 2-way version

Check valve, pilot operated

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)

Proportional pressure reducing valve, pilot operated, with inductive position transducer

29 158/ Proportional Pressure Relief Valve Models DBE and ZDBE, Series 1X. Ordering code DBE 6 1X G24 1/ PSI (315 bar)

Proportional flow control valve. Type 2FRE. Features. Contents. RE Edition: Replaces: 02.07

Proportional pressure reducing valve Type FTDRE 4 K

Hydraulic primary unit Type ABPAG

Industrial Hydraulics FAQs

Proportional pressure relief valve with linear curve (Lvdt AC/AC)

Rexroth Hydraulics. Servo directional valve of 4-way design Type 4WS.2EM RE /03.99

Supply pressure compensator, direct operated

Proportional flow control valve, with inductive position transducer

Throttle and throttle check valve

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Proportional pressure reducing valve, pilot operated

Pressure relief valve, pilot operated

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

Proportional pressure relief valve

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

Proportional pressure relief valve, pilot operated

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

Proportional flow control valve, with integrated pressure compensator

2-way flow control valve

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Proportional pressure relief valve, directly operated, rising characteristic curve

Servo solenoid valves with on-board electronics (OBE)

Proportional directional valve, direct operated, with pq functionality

Servo solenoid valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)

2-way flow control valve

Pressure reducing valve, direct operated

4/3 directional servo-valve with mechanical position feedback

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Pressure reducing valve, pilot operated

Servo solenoid valves with electrical position feedback (Lvdt AC/AC)

3/3 servo directional control valve with mechanical position feedback

Meter-in pressure compensator, direct operated

Check valve, pilot operated

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Check valve, pilot operated

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

Check valve, pilot operated

Servo solenoid valves with electrical position feedback (Lvdt DC/DC ±10 V)

Servo solenoid valves with on-board electronics (OBE)

Check valve, pilot operated

Servo solenoid valves with positive overlap Position feedback (Lvdt DC/DC ±10 V)

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Check valve, pilot operated. Type SV and SL. Features. Contents. RE Edition: Replaces:

Servo solenoid valves with on-board electronics (OBE)

Pressure relief valve, pilot operated

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Fixed displacement vane pumps Types PVV and PVQ

Return line filter for direct tank mounting Type ABZFR

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Hydraulic cylinder Type CDL1

4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback (Lvdt DC/DC ±10V)

Servo solenoid valves with positive overlap and on-board electronics

Pressure sequence valve, direct operated

Pressure relief valve, directly operated

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Transcription:

RE 29 142/11.02 Replaces: 02.99 Proportional pressure relief valve Types DE(M) and DE(M)E Nominal size 32 1) Series 3X Maximum operating pressure 3 bar Maximum flow 600 L/min H/ 1764 1) NS 10; 25, Series 5X see RE 29 160 Type DE -3X/...G24K4... with plug-in connector and associated control electronics (separate order) Overview of contents Contents Page Features 1 Ordering details 2 Preferred types 2 Symbols 2 Function, section 3 Technical data 4 and 5 Control electronics 5 and 6 Electrical connections, plug-in connectors 5 Characteristic curves 7 Unit dimensions 8 Features Pilot operated valve for limiting a system pressure Operation via proportional solenoids For subplate mounting: Porting pattern to DIN 24 340, form E Subplates to catalogue sheet RE 45 064, (separate order, see page 8) Optional additional maximum pressure limitation by means of a spring loaded pilot control valve Control electronics for type DE(M): nalogue amplifier VT-VSP1-1 in Eurocard format (separate order, see page 5) nalogue amplifier VT 0 (separate order, see page 5) Digital amplifier VT-VSPD-1 in Eurocard format (separate order, see page 5) nalogue amplifier VT 110 of modular design (separate order, see page 5) Integrated control electronics for type DE(M)E: Low example spread of the command value-pressurecharacteristic curve Independently adjustable up and down ramps 2 by osch Rexroth G, Industrial Hydraulics, D-97813 Lohr am Main ll rights reserved. No part of this document may be reproduced or stored, processed, duplicated or circulated using electronic systems, in any form or by any means, without the prior written authorisation of osch Rexroth G. In the event of contravention of the above provisions, the contravening party is obliged to pay compensation. This document was prepared with the greatest of care, and all statements have been examined for correctness. This document is subject to alterations for reason of the continuing further developments of products. No liability can be accepted for any incorrect or incomplete statements. DE(M); DE(M)E 1/8 RE 29 142/11.02

Ordering details Proportional pressure relief valve Without maximum pressure limitation = No code With maximum pressure limitation = M For external control electronics = No code With integrated control electronics = E Nominal size 32 = Series to 39 ( to 39: unchanged installation and connection dimensions) DE 3X G24 * = 3X Pressure stage Up to bar = Up to 100 bar = 100 Up to bar = Up to 315 bar = 315 Up to 3 bar = 3 Internal pilot oil supply, external pilot oil drain = External pilot oil supply, external pilot oil drain = X G24 = Further details in clear text M = NR seals, suitable for mineral oil (HL, HLP) to DIN 51 524 V = FKM seals Electrical connections For DE; DEM: K4 = Without plug-in connector, with component plug to DIN EN 175 1-803 Plug-in connector separate order, see page 5 For DEE; DEME: K31 = Without plug-in connector, with component plug to E DIN 43 563-M6-3 Plug-in connector separate order, see page 5 Supply voltage to the control electronics 24 V DC Special protection versions on request! Preferred types Material No. R900954717 R900954713 R900954714 R900954715 R900954716 Type DEME DEME -3X/G24K31M DEME -3X/100G24K31M DEME -3X/G24K31M DEME -3X/315G24K31M DEME -3X/3G24K31M Further preferred types and standard units are to be found in the EPS (Standard Price List). Symbols Type DE(E) -3X/ Type DE(E) -3X/ X Type DEM(E) -3X/ Type DEM(E) -3X/ X X X RE 29 142/11.02 2/8 DE(M); DE(M)E

Function, section Valve types DE and DEM are pilot operated pressure relief valves. They are used to limit the pressure in a hydraulic system. With these valves it is possible, in relation to the electrical command value, to infinitely adjust the pressure to be limited. These valves basically consist of the pilot control valve (1) with proportional solenoid (2) and the main valve (3) with main spool insert (4). Type DE The adjustment of the pressure is command value dependent via a proportional solenoid (2). The pressure present in port acts on the underside of the main spool (4). t the same time this pressure acts on the spring loaded side of the main spool (4) via control line (8) which is fitted with orifices (5, 6, 7). The hydraulic force acts on the pilot poppet (10) via valve seat (9) against the force proportional solenoid (2). When the hydraulic force overcomes the solenoid force then the pilot poppet (10) opens. Due to the fact that the pilot oil can now flow to tank via port (12) a pressure drop occurs at the orifices (5, 6) which acts on the main spool and lifts it against the force of the return spring (10). The connection from to is opened and there is no longer any increase in pressure. 1 9 12 10 2 Type DEM Optionally the valve can be supplied with an additional spring loaded pilot control valve (13) for maximum pressure safety (redundant pressure safety function). It is recommended that this version is always selected! When applying these valves take the guidelines stated on page 4 into account. Types DEE and DEME (with integrated control electronics) The function and design of these valves, with the exception of the integrated control electronics, is basically the same as the types DE and DEM. The control electronics which are located in the housing (14) receive the supply and command value voltages via the plug-in connector (15). The command value-pressure-characteristic curve (zero point at valve seat (9) and the increase at the I max potentiometer (R) in the control electronics) is factory pre-set with a low example spread. t the two potentiometers it is possible to independently adjust the ramp times for increase in pressure and decrease in pressure. For further details regarding the integrated control electronics, see pages 5 and 6. 11 Port "X" Plugged with internal pilot oil supply 12 Port "" External pilot oil drain separate and at zero pressure to tank Section a a 7 6 8 3 4 5 12 Type DE... X 13 Type DEM (with maximum pressure safety) 15 14 Type DE(M)E - DE(M); DE(M)E 3/8 RE 29 142/11.02

Technical data (for applications outside these parameters, please consult us!) General Installation Optional Storage temperature range C 20 to + 80 mbient DE and DEM C 20 to + 70 temperature range DEE and DEME C 20 to + Weight DE and DEM kg 6.0 DEE and DEME kg 6.2 Hydraulic (measured with HLP 46, ϑ oil = 40 C ± 5 C and p = 100 bar) Maximum operating pressure Ports, and X bar 3 Port Maximum settable pressure Pressure stage bar bar Pressure stage 100 bar bar 100 Pressure stage bar bar Pressure stage 315 bar bar 315 Pressure stage 3 bar bar 3 Separate and at zero pressure to tank Minimum settable pressure at port with a zero command value bar See characteristic curves on page 7 Maximum pressure safety (infinitely adjustable) djustable pressure range: Setting as required: Pressure stage bar bar to 70 Up to 70 bar Pressure stage 100 bar bar to 1 Up to 1 bar Pressure stage bar bar 90 to 2 Up to 2 bar Pressure stage 315 bar bar 1 to 3 Up to 3 bar Pressure stage 3 bar bar 180 to 390 Up to 390 bar Maximum flow L/min 600 Pilot flow L/min 0.7 to 2 Pressure fluid Mineral oil (HL, HLP) to DIN 51 524, Further pressure fluids on request! Pressure fluid temperature range C 20 to + 80 Viscosity range mm 2 /s 15 to 380 Cleanliness class to ISO code Maximum permissible degree of contamination of the pressure fluid is to ISO 4406 (C) class 20/18/15 1) Hysteresis (see command value-pressure-char. curves on page 7) % ± 1.5 of max. settable pressure Repeatability % < ± 2 of max. settable pressure Linearity % ± 3.5 of max. settable pressure Example spread of the DE und DEM % ± 2.5 of max. settable pressure com.value-pressure-char. DEE und DEME % ± 1.5 of max. settable pressure curve, relating to the hysteresis char. curve, pressure increasing Stepped response T u + T g 0 100 % ms 1 dependent on the flow and the 100 0 % ms 1 system pipe work volume (in ) 1) The cleanliness class stated for the components must be adhered to in hydraulic systems. Effective filtration prevents faults from occurring and at the same time increases the component service life. For the selection of filters see catalogue sheets RE 070,RE 076, RE 081 RE 29 142/11.02 4/8 DE(M); DE(M)E

Technical data (for applications outside these parameters, please consult us!) Electrical Supply voltage Min. control current m 100 Max. control current DE and DEM m 800 24 V DC DEE and DEME m 1600 Coil resistance Cold value at 20 C Ω 19.5 Max. warm value Ω 28.8 Duty % 100 Electrical connections DE and DEM With component plug to DIN EN 175 1-803 DEE and DEME Plug-in connector to DIN EN 175 1-803 1) With component plug to E DIN 43 563-M6-3 Plug-in connector to E DIN 43 563-F6-3/Pg11 1) Valve protection to DIN 40 0 IP 65 with mounted and fixed plug-in connector Control electronics For DEE and DEME Integrated into the valve, see page 6 For DE and DEM mplifier in Eurocard format 1) nalogue VT-VSP1-1 to catalogue sheet RE 111 VT 0 to catalogue sheet RE 29 904 Digital VT-VSPD-1 to catalogue sheet RE 123 mplifier of modular design 1) nalogue VT 110 to catalogue sheet RE 29 741 1) Separate order Note: For details regarding the environmental simulation test covering EMC (electro-magnetic compatibility), climate and mechanical loading see RE 29 142-U (declaration regarding environmental compatibility). Electrical connections, plug-in connectors For types DE and DEM (for external control electronics) Plug-in connector to DIN EN 175 1-803, separate order under Material No. R900074684 Connections at component plug 27,5 27,5 53 PE 36 Ø22,5 1 2 Connections at plug-in connector PE 1 2 To amplifier For types DEE and DEME (with integrated control electronics) Plug-in connector to E DIN 43 563-F6-3/Pg11, separate order under Material No. R900021267 (plastic version) 91 Ø27 F For pin allocation see block circuit diagram on page 6 Ø6,5 Ø11 C D E DE(M); DE(M)E 5/8 RE 29 142/11.02

Integrated control electronics for types DEE, DEME Function The control of the integrated electronics is at the two differential amplifier connections D and E. The ramp generator generates a delayed increase or decrease of the solenoid current from a command value jump (0 to 10 V or 10 to 0 V). t the potentiometer R14 the increase time of the solenoid current may be set and the decrease time at potentiometer R13. The maximum ramp time of 5 s is only possible over the complete command value range. With smaller command value changes the ramp time is accordingly shortened. The command value-solenoid current characteristic curve is matched to the valve via the characteristic curve generator in such a way that any unlinearities are compensated for in the hydraulics and thus a linear command value-pressure-characteristic curve is formed. The current controller controls the solenoid current independently from the solenoid coil resistance. t the potentiometer R the increase of the command value current characteristic curve and thus also the increase of the command value pressure characteristic curve of the proprtional pressure valve may be altered. Potentiometer R43 is used for the setting the bias current. This setting should not be altered. If necessary the zero point of the command value-pressure-characteristic curve may be set at the valve seat. The power stage of the electronics for the control of the proportional solenoid forms a chopper amplifier. It is pulse width modulated with a pulse frequency 0 Hz. The solenoid current may be measured at the test points MP1and MP2. voltage decrease of 0.352 V at the measuring resistance equals a solenoid current of 1.6. lockcircuit diagram / pin allocation of the integrated control electronics Com. value 0 to 10 V 0V ref. potential Supply voltage: U eff : 22 to 33 V 0 V D + E F C + n.c. n.c. Differential amplifier U = U = Ramp generator R 14 R 13 Ramp "up" Power supply Ramp "down" +U +7,5 V -7,5 V Char. curve generator Internal ref. point Current controller I max I min R I R 43 0 Hz = Oscillator +U Chopper amplifier Measuring resistance R=0,22 Ω 0 V Solenoid MP1 1,6 = 0,352 V MP2 Supply voltage Power supply with rectification single phase rectification or three phase bridge: U eff = 22 to 33 V Residual ripple at power supply: < 5 % Output current: I eff = max. 1.4 Supply cable: Recommended 5 core 0.75 or 1 mm 2 with protective conductor and screen Outside diameter 6.5 to 11 mm Screen on 0 V supply voltage Max. permissible length 100 m The minimum supply voltage at the power supply depends on the length of the supply cable (see diagram). With lengths > m a capacitor of 2 µf must be installed near the valve in the supply line. Min. supply voltage in V Ueff 28 26 24 22 0,75 mm 2 1 mm 2 20 40 60 80 100 l Length of supply cable in m RE 29 142/11.02 6/8 DE(M); DE(M)E

Characteristic curves (measured with HLP 46, ϑ oil = 40 C ± 5 C and p = 100 bar) Pressure in port in bar 3 0 2 1 100 Pressure in port in relation to the flow 0 75 1 225 0 375 Flow in L/min Min. settable pressure in port in bar 35 25 20 15 10 5 Min. settable pressure in port with a zero command value 4 525 600 0 75 1 225 0 375 4 525 600 Flow in L/min Note: So that the minimum settable pressure can be achieved the bias current must not exceed 100 m. Pressure in port in relation to the command value (measured at a flow of 27 L/min) Pressure in port in bar Pressure stage bar 45 40 35 25 20 15 Dead zone 10 5 Pressure in port in bar 100 90 80 70 60 40 20 10 Pressure stage 100 bar Dead zone Pressure in port in bar Pressure stage bar 180 160 140 120 100 80 60 Dead zone 40 20 Pressure in port in bar Pressure stage 315 bar 315 0 2 1 100 Dead zone Pressure in port in bar Pressure stage 3 bar 3 0 2 1 100 Dead zone DE(M); DE(M)E 7/8 RE 29 142/11.02

Unit dimensions (dimensions in mm) 113 15 40 138 122,5 Ø 23; 1 16 X1 Ø 12,3; 1,3 11 115 82,5 3 X X 7 10 6 2.1 2.2 3 Ø 31 M8x1 9 1 31,8 41,5 44,5 12,7 76,2 148 88,9 Ø 23; 1 G 1/4 Ø 40,7; 2,7 286 5 26 Ø 20 Ø 28 Pg 11 (with integrated control electronics) 8 174 15 R40 4 5 1 Identical seal rings for ports and Seal ring for port X 2.1 Plug-in connector for type DE(M) (separate order, see page 5) 2.2 Plug-in connector for type DE(M)E (separate order, see page 5) 3 Space required to remove the plug-in connector 4 Space required for the cable bend radius when removing the plug-in connector 5 Cable bend radius 6 Integrated control electronics (types DEE, DEME) with component plug 7 Name plate 8 Maximum pressure limitation (types DEM, DEME) When applying this valve, please take into account the guidelines stated on pages 3 and 4. 9 External pilot oil supply, optionally at ports X or X1 10 External pilot oil drain, always external, separate and at zero pressure to tank 11 Locating pin Ø 6 mm 0,01/100mm R 4 max Required surface finish of the mating piece Subplates to catalogue sheet RE 45 064 and valve fixing screws must be ordered separately. Subplates: G 410/01 (G 1 1/4) G 411/01 (G 1 1/2) Valve fixing screws: M18 x DIN 912-10.9; M = 160 Nm osch Rexroth G Industrial Hydraulics D-97813 Lohr am Main Zum Eisengießer 1 D-97816 Lohr am Main Telefon 0 93 52 / 18-0 Telefax 0 93 52 / 18-23 58 Telex 6 89 418-0 email documentation@boschrexroth.de Internet www.boschrexroth.de osch Rexroth Limited Cromwell Road, St Neots, Cambs, PE19 2ES Tel: 0 14 80/22 32 56 Fax: 0 14 80/21 90 52 E-mail: info@boschrexroth.co.uk The data specified above only serves to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. It must be remembered that our products are subject to a natural process of wear and ageing. RE 29 142/11.02 8/8 DE(M); DE(M)E