A starting method of ship electric propulsion permanent magnet synchronous motor

Similar documents
Applications of Frequency Conversion Technology in Aircompressor

QUESTION BANK SPECIAL ELECTRICAL MACHINES

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1001 SPECIAL ELECTRICAL MACHINES

Rotor Position Detection of CPPM Belt Starter Generator with Trapezoidal Back EMF using Six Hall Sensors

CHAPTER 6 INTRODUCTION TO MOTORS AND GENERATORS

Note 8. Electric Actuators

Research on the Structure of Linear Oscillation Motor and the Corresponding Applications on Piston Type Refrigeration Compressor

Electrical Machines II. Week 5-6: Induction Motor Construction, theory of operation, rotating magnetic field and equivalent circuit

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

Chapter 4 DC Machines

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

PHY 152 (ELECTRICITY AND MAGNETISM)

Renewable Energy Systems 13

Procedia - Social and Behavioral Sciences 195 ( 2015 ) World Conference on Technology, Innovation and Entrepreneurship

Available online at ScienceDirect. Procedia CIRP 33 (2015 )

Hardware Design of Brushless DC Motor System Based on DSP28335

Available online at ScienceDirect. Procedia Engineering 129 (2015 ) International Conference on Industrial Engineering

Inverter control of low speed Linear Induction Motors

3rd International Conference on Material, Mechanical and Manufacturing Engineering (IC3ME 2015)

Passive Vibration Reduction with Silicone Springs and Dynamic Absorber

Modeling and Simulation of the drive system of elevator based on AMESIM

Forced vibration frequency response for a permanent magnetic planetary gear

A Linear Magnetic-geared Free-piston Generator for Range-extended Electric Vehicles

TRANSIENT ANALYSIS OF A BLDC STARTER/GENERATOR SYSTEM USED IN ELECTRIC VEHICLES

IMPACT OF SKIN EFFECT FOR THE DESIGN OF A SQUIRREL CAGE INDUCTION MOTOR ON ITS STARTING PERFORMANCES

Introduction: Electromagnetism:

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

Fachpraktikum Elektrische Maschinen. Theory of Induction Machines

Planning and Commissioning Guideline for NORD IE4 Synchronous Motors with NORD Frequency Inverters

Short Term Course On Hydropower Development Engineering (Electrical) for Teachers of Polytechnics in Uttarakhand L33-2

CHAPTER 5 ANALYSIS OF COGGING TORQUE

Experimental Study on Overflow Pipe Structure of the Rod Pump with Down-hole Oil-water Hydrocyclone

Synchronous Generators I. EE 340 Spring 2011

5. LINEAR MOTORS 5.1 INTRODUCTION

AXIAL FLUX PERMANENT MAGNET BRUSHLESS MACHINES

International Journal of Advance Research in Engineering, Science & Technology

Synchronous Motor Drives

Synchronous Generators I. Spring 2013

Open Access Calculation for the Heating and Safe Operation Time of YKK Series Highvoltage Motors in Starting Process

Piktronik d. o. o. Cesta k Tamu 17 SI 2000 Maribor, Slovenia Fax:

Analysis on natural characteristics of four-stage main transmission system in three-engine helicopter

Doubly fed electric machine

Characteristics Analysis of Novel Outer Rotor Fan-type PMSM for Increasing Power Density

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

Armature Reaction and Saturation Effect

Combination control for photovoltaic-battery-diesel hybrid micro grid system

Unit 32 Three-Phase Alternators

Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load

DHANALAKSHMI SRINIVASAN COLLEGE OF ENGINEERING AND TECHNOLOGY MAMALLAPURAM, CHENNAI

EVS25. Shenzhen, China, Nov 5-9, 2010

Analysis and Design of the Super Capacitor Monitoring System of Hybrid Electric Vehicles

COMPARING SLOTTED vs. SLOTLESS BRUSHLESS DC MOTORS

Modern Motor Control Applications and Trends Tomas Krecek, Ondrej Picha, Steffen Moehrer. Public Information

Optimization of PID Parameters of Hydraulic System of Elevating Wheelchair Based on AMESim Hui Cao a*, Hui Guo b

Planning and Commissioning Guideline for NORD IE4 Motors with NORD Frequency Inverters

BELT-DRIVEN ALTERNATORS

Permanent Magnet Machines for Distributed Generation: A Review

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

Advances in Engineering Research, volume 93 International Symposium on Mechanical Engineering and Material Science (ISMEMS 2016)

Electrical Machines and Energy Systems: Overview SYED A RIZVI

A Practical Guide to Free Energy Devices

GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER

Electrical Theory. Generator Theory. PJM State & Member Training Dept. PJM /22/2018

Transient analysis of a new outer-rotor permanent-magnet brushless DC drive using circuit-field-torque coupled timestepping finite-element method

Sub:EE6604/DESIGN OF ELECTRICAL MACHINES Unit V SYNCHRONOUS MACHINES. 2. What are the two type of poles used in salient pole machines?

Permanent Magnet DC Motor


Comparative Study of Maximum Torque Control by PI ANN of Induction Motor

Design and experiment of hydraulic impact loading system for mine cable bolt

B.E-EEE(Marine) Batch 7. Subject Code EE1704 Subject Name Special Electrical Machines

Permanent Magnet Synchronous Motor. High Efficiency Industrial Motors

Available online at ScienceDirect. Physics Procedia 67 (2015 )

International Conference on Advances in Energy and Environmental Science (ICAEES 2015)

UNIT 2. INTRODUCTION TO DC GENERATOR (Part 1) OBJECTIVES. General Objective

Available online at ScienceDirect. Procedia Engineering 137 (2016 ) GITSS2015

The instantaneous torque is pulsating. The average value of the torque is

Research and Reviews: Journal of Engineering and Technology

PM Assisted, Brushless Wound Rotor Synchronous Machine

ANALYSIS OF WIND AND PV SYSTEMS 4.1 Wind Energy Conversion Systems (WECS)

Core Loss Effects on Electrical Steel Sheet of Wound Rotor Synchronous Motor for Integrated Starter Generator

INTRODUCTION. I.1 - Historical review.

Dev Bhoomi Institute Of Technology LABORATORY Department of Electrical And Electronics Engg. Electro-mechanical Energy Conversion II

General Purpose Permanent Magnet Motor Drive without Speed and Position Sensor

Converteam: St. Mouty, A. Mirzaïan FEMTO-ST: A. Berthon, D. Depernet, Ch. Espanet, F. Gustin

Modeling and Simulation of Five Phase Inverter Fed Im Drive and Three Phase Inverter Fed Im Drive

Contents. Review of Electric Circuitd. Preface ;

A Dual Stator Winding-Mixed Pole Brushless Synchronous Generator (Design, Performance Analysis & Modeling)

Lab Electrical Power Engineering I

Whitepaper Dunkermotoren GmbH

Lab 6: Wind Turbine Generators

CHAPTER 4 HARDWARE DEVELOPMENT OF DUAL ROTOR RADIAL FLUX PERMANENT MAGNET GENERATOR FOR STAND-ALONE WIND ENERGY SYSTEMS

Australian Journal of Basic and Applied Sciences. Resonant Power Converter fed Hybrid Electric Vehicle with BLDC Motor Drive

Experimental Study on Inlet Structure of the Rod Pump with Down-hole Oil-water Hydrocyclone

Asynchronous slip-ring motor synchronized with permanent magnets

Simulation of Indirect Field Oriented Control of Induction Machine in Hybrid Electrical Vehicle with MATLAB Simulink

Effect of Permanent Magnet Rotor Design on PMSM Properties

One-Cycle Average Torque Control of Brushless DC Machine Drive Systems

INTRODUCTION TO SENSORS, TRANSDUCERS & ACTUATORS

Date: Name: ID: LABORATORY EXPERIMENT NO. 8 INDUCTION MOTOR/GENERATOR 8-1

Transcription:

Available online at www.sciencedirect.com Procedia Engineering 15 (2011) 655 659 Advanced in Control Engineeringand Information Science A starting method of ship electric propulsion permanent magnet synchronous motor Qingshan Ji a, Guoping Liu a,b,a* a Electromechanical College of Zhejiang Ocean University, zhoushan 316000, China b Zhejiang ship Advanced Manufacturing Technology R & D Center, zhoushan 316000, China Abstract The propulsion system consisted of the AC - AC Converter and permanent magnet synchronous motor used more often in the current ship electric propulsion. The firstly solving problem is the PMSM starting. In this paper, based on briefly describing the ship electric propulsion system, analyzed the characteristics of the PMSM starting, the system used open-loop frequency starting mode. The analysis shows that the way in ship propulsion PMSM starting running condition, is simple, reliable, good starting performance. The starting mode can also be used as the starting method of a large PMSM for other purposes. 2011 Published by Elsevier Ltd. Open access under CC BY-NC-ND license. Selection and/or peer-review under responsibility of [CEIS 2011] Keywords: ship electric propulsion; PMSM, starting; frequency;open-loop 1. Introduction The ship Electric propulsion is a propulsion way that propulsion motor directly drives the propellers. The propulsion device generally is consisted of propellers, motors, generators, prime mover and the control conditioning and other components. Electric propulsion has low noise, good mobility, flexibility shipping space and other advantages. Using electric propulsion can avoid the prime mover's wide range speed regulation, and improve its efficiency. But, on the other hand, in the machine - electric - machine conversion process, it also increases * Qingshan Ji. Tel.: 13505809346; fax: 0580-8287728. E-mail address: jqs_789@163.com. 1877-7058 2011 Published by Elsevier Ltd. doi:10.1016/j.proeng.2011.08.122 Open access under CC BY-NC-ND license.

656 Qingshan Ji and Guoping Liu / Procedia Engineering 15 (2011) 655 659 energy consumption [1]. Therefore, the propulsion motors must have high efficiency, and can meet the ship promoting conditions. With the development of the power electronics technology and magnetic materials, in the ship electric propulsion system, the permanent magnet synchronous motor was usually used. Compared with the conventional motor, it has high power density, high torque density, high efficiency, high power factor and so on. The propulsion system consisted by the permanent magnet synchronous motor, is low noise, high efficiency, maintenance and performance better. Because the ship propulsion is large power and low speed, currently CYCLO propulsion systems is most widely used [2]. The system is consists of AC- AC converter +AC synchronous motor. According to the control requirements, the converter selects the different Phase intervals of AC power, and provides alternating current to the synchronous motor. Its upper limit of the speed regulation is generally not more than 40% of the base frequency. The first condition of PMSM running is starting. According to the principle of synchronous motor shows that: only in the synchronous condition, the average electromagnetic torque can consist. The starting process is that the motor s rotor speed increases from zero. It is non-synchronous operation state. The average electromagnetic torque is zero, which can not make the rotor accelerating. So the synchronous motor is not self-starting. On literature [3], a variety of medium and large synchronous motor starting modes have been conducted recapitulative discussion. For large synchronous motor, the modern inverter technology is used in the static frequency converter starting. Either efficiency or control performance are relatively good. In this paper, based on the actual working conditions of the large ship propulsion, the open loop variable frequency start method was used. 2. the Theoretical Analysis of PMSM Starting Characteristics When the Electrically excited synchronous motor started asynchronously, in order to successfully start and ensure safety, the field-winding must string the current limiting resistor closed. When it will reach synchronized, and then excitation is begun. However, in the permanent magnet synchronous motor, the excitation can not be adjusted. No matter what running condition of the motor, a certain excitation is always provided. Therefore, during the permanent magnet synchronous motor s starting process, its physical phenomena is much more complex than the asynchronous motor or electrically excited synchronous motor. In the PMSM starting process, when the stator winding is applied the three phase AC current at frequency f 1. This current establish the air-gap magnetic field that it rotates at the synchronize speed n 1. In the rotor conductors, the air-gap magnetic field induces AC current at frequency f 2 = sf 1. The AC current produces asynchronous electromagnetic torque, which it is same with the general asynchronous motor. It is known as asynchronous torque. The permanent magnet magnetic field and the rotating magnetic field produced by stator current is asynchronous operation. Having relative motion between the two can not form synchronized torque. However, considering the superposition principle, the permanent magnetic field and the rotor windings can form a synchronous generator. In the Stator winding, besides the current of fundamental frequency f 1, the induced current that its frequency is (1-s) f 1 appears. The stator rotating magnetic field and permanent magnet field created by the current can form generator brake torque. The curve 2 is shown in figure 1. Because the reactance of quadrature axis and direct axis is not equal, the induced current that its frequency is (1-2s) f 1 appears. The stator rotating magnetic field and permanent magnet field created by the current can generate Reluctance torque. The curve 3 is shown in figure 1. After the above-mentioned three kinds of torque were synthesized, the total starting torque of PMSM can be obtained. The curve 4 is shown in figure 1.

Qingshan Ji and Guoping Liu / Procedia Engineering 15 (2011) 655 659 657 Fig.1. Starting characteristics of Permanent Magnet Synchronous Motor 1 - Asynchronous Torque 2 - Generator Brake Torque 3 Reluctance Torque 4 - Synthesis Torque The above analysis, the electromagnetic torque produced by the fundamental wave rotating magnetic field in air gap, was only taken into account. In fact, the air gap magnetic field contains harmonic component. For example, the magnetic field generated by the stator winding current contains a series of harmonic components. Because of the stator and rotor slotting, the air-gap magnetic field waveform produced by permanent magnets appears a serrated square wave, which also contains harmonic components [4]. In the starting process, the synthetical electromagnetic torque having the harmonic components, makes the T-S curve produce irregular oscillation. Therefore, the PMSM s actual starting process was more complicated. 3. Starting Strategy for ship electric propulsion PMSM 3.1. Frequency starting principle The electric propulsion PMSM is powered by converter. The starting should be adopted frequency starting methods. For the synchronous motor, the rotor speed is: n=n 0 =60f 1 /P (1) In which: n 0 is the synchronous speed, n is the rotor speed, f 1 is the power frequency, P is pole pairs. The formula (1) shows that, when the pole-pairs P is unchanged, the rotor speed n is proportional to the power s frequency f 1. Therefore, through the converter continuous changing frequency of power supply, the motor speed can be smoothly adjusted. But the power frequency changing is bound to cause changes in other parameters of the motor. The motor parameters changes would affect its performances. In the ship electric propulsion, during the speed adjusting process the same motor overload is wanted to keep. That is, maximum torque is maintained unchanged. The maximum torque of synchronous motor is: T m =Cu 2 2 /f 1 (2) Where, T m is the maximum torque, u is stator voltage, f 1 is the grid frequency, C is a constant. By the formula (2) shows that while the frequency changes, the stator voltage produces correspond change, making u/f 1 unchanged. That is, the magnetic flux maintain constant, the maximum torque T m can maintain unchanged. Relative to the asynchronous starting, the advantages of synchronization starting are: It has more affordability to the torque disturbances. It can make a faster dynamic response [5]. 3.2. Open loop frequency starting strategy Before starting, if the rotor position can be accurately detected, the starting process is relatively simple. Only controlling the stator current accordingly changes with the rotor rotation, which ensure electromagnetic torque unchanged. PMSM can normally accelerate and rotate. The rotor s initial position

658 Qingshan Ji and Guoping Liu / Procedia Engineering 15 (2011) 655 659 detection not only adopts optical encoders directly detect, but also adopts a variety of positions detection algorithm without the sensor, such as model reference self-adapting, extended Kalman filter, sliding mode variable structure and so on. The reasoning process of these algorithms is very complicated, and depends on motor parameters. Ship electric propulsion system doesn t need the accurate monitoring to the rotor position and shaft output. The load change is not large, and it doesn t need feedback device. So the "open loop" system can be used. In the open-loop state, the motor torque and speed changes with the load and supply voltage. The motor is usually achieved by VVVF control. The inverter outputs a sinusoidal voltage to the motor stator windings, making it run at a given speed. The starting strategy is: not detecting the rotor position, adopting the open-loop starting makes the rotor to the desired location and then switch to the closed-loop control. There are two methods which can make the rotor reach the desired location: 1 The converter applied DC voltage to synchronous motor armature winding, which can make the rotor magnetic pole point to the stator pole s the opposite end. 2 Controlling the stator MMF made the rotor position fall on the specified location. In order to facilitate the control signal applied, letting the rotor predetermined position d-axis coincided with A axis. It is shown in Figure 2. As long as the controlling motor stator s three-phase currents make the direction of F r fall on A shaft, the above purpose can be achieved. Fig. 2. PMSM stator MMF synthesis diagram The inverter makes the upper bridge arm of A phase breakover, the lower bridge arm of B and C phase breakover. Then FA is along the A axis positive direction, FB, FC are respectively along the B, C-axis negative direction. According to Vector Synthesis, the stator magnetomotive force of the three-phase synthesis F r is along the A axis positive direction. This completes the initial positioning of the rotor. 4. PMSM starting process of ship electric propulsion 4.1. Starting Method The starting process is that through the adjustment of the inverter output frequency, from the "Initial starting frequency" starting, according to the certain curve laws increased, and ultimately reach the normal frequency. In this process, the voltage proportionally increases with frequency, and U/f 1 always maintains constant. In the early starting, starting frequency is very low, and the relative velocity of the permanent magnet rotor and the stator producing rotating magnetic field is also very low. Although the motor flux is still close to or equal to the rated fluxφ N, the starting current will be limited within a certain range. 4.2. Starting process 1) Rotor positioning: the converter applies a certain DC voltage to synchronous motor armature winding, then this voltage produces some stator current, and the current creates stronger magnetic field on the stator. Or controlling the stator MMF, the rotor falls on the specified location. Under the

Qingshan Ji and Guoping Liu / Procedia Engineering 15 (2011) 655 659 659 electromagnetic force action between the stator and rotor, the rotor begins rotation, and it makes the rotor magnetic pole gradually close to the opposite end of the stator poles. At this point, the rotation direction of the rotor may be the same direction with the motor when it is normal running, and may also be the opposite direction. 2) Variable frequency synchronous starting: according to the rotation direction of the motor normal operation, the converter slowly rotates the voltage vector applied on the armature winding. With the rotor rotation and the stator magnetic field rotation of synchronous motor, the rotor magnetic poles will pass the opposite poles of the stator at a time, or the rotor poles accelerates to catch up with the revolving stator magnetic poles. At this point, the motor s rotor pole is reliably attracted by the stronger stator pole, and by a little damping shock, the angle between the two gradually become a smaller constant. Thus, the synchronous motor goes into the synchronous operation state, and the synchronizing process is complete. In accordance with the pre-setting acceleration, the converter gradually accelerated to a given frequency. Synchronous motor s rotor angle is gradually widening to a certain value (determined by the load size), and under the stator magnetic field attraction the rotor pole was gradually accelerated to a desired speed. The starting process of synchronous motor completes. 5. Conclusions The open-loop frequency starting control system of the permanent magnet synchronous motor in the ship electric propulsion starts smoothly, which the starting current (torque) can be gradually increased from zero. There is no desynchronizing problem. It almost no impact on the grid, is high reliability, has good application prospects, and is worthy of promotion. References [1]Haiming Shou, Luming Ji, Shoujun Ma. Research on Modern Marine Propulsion Motor Technology. Mechanical & Electrical Technology. 2007; Vol.27(1):36-39. [2] Haibo Gao, Xiaohong Gao, Hui Chen. The Comparison of Several Typical ways of Ship Electric Propulsion. Marine Technology. 2006;6: 54-57. [3] Lanwen Liu. Large pumping station synchronous motor starting mode's comprehensive analysis. Design of Water Resources & Hydroelectric Engineering. 2006;vol.25(4):31-34. [4]Yalin Wu. Study for the Start Characteristic of Rare Earth and Permanent Magnetism and Synchronous Motor. FUJAN DIANLI YU DIANGONG. 2004; 24(3):23. [5]Rong Xu, Pengfei Liu. Synchronous Motor Frequency Starting Strategy. CHINA SCIENCE AND TECHNOLOGY INFORMATION. 2008;5:70-72.