MIS SERIES. Mist Eliminator. Installed differential pressure gauge and optional zero air-loss drain valve. Air or Water Cooled Aftercooler

Similar documents
Your Plant Deserves Pure-Aire!

ZTF. Compressed Air Filters scfm INNOVATIVE COMPRESSED AIR SOLUTIONS FILTER ASSEMBLIES ELEMENT OPTIONS SPECIFICATIONS ACCESSORIES

Compressed Air and Gas Filters

COMPRESSED AIR FILTERS

Air Filtration CLEARPOINT. energy saving compressed air filtration. Truth in Compressed Air.

F200 Series. Compressed Air and Gas Filters FEATURES. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades

F200 Series. Compressed Air and Gas Filters. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades

Product Range & Price Guide

Product Range. March 2010

ALUMINIUM COMPRESSED AIR FILTERS

High efficiency compressed air filtration & water separation

FRL/AirCare Air Controls & Accessories

Balston Stainless Steel Compressed Air Filters for Food Processing and Packaging

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

F20 & F21 QIX Particulate & Coalescing Filters

Modulating Water Valves and Bulb Wells

SV73 Cast Iron Safety Valve

Model Model 815

Model Number Height* Width Depth ⅜ 1P-060-F03-P ½ 1P-060-F04-P ¾ 1P-120-F06-P P-175-F08-P

A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories

1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S

THE NEW GENERATION! COMPRESSED AIR FILTERS AND WATER SEPARATORS INTELLIGENT AIR TECHNOLOGY

The Technology of Modern Filtration Filters Designed and Built for Today s Industries

Compressed Air Filters

A-4000 Series Oil Removal and Pressure Reducing Stations & Air Compressor Accessories

CNG FILTRATION. Natural Gas Vehicle (NGV) Filters. Trucks Vans Cars Forklifts.

50 SERIES FILTER F50B Series F50B-04 pictured Application ANSI SYMBOL Primary air filters are designed to separate liquid, water, rust, pipe scale, an

Section: D Alternative Fuel

Compressed Air Filters

KSI Filtertechnik GmbH Siemensring D Willich Tel Fax

3000 Series filters 3/4" and 1" Ports

Filters, regulators, and lubricators

IC3A, IC3D, IC4A and IC4D ISO Spirax-Monnier International Ultraclean Compressed Air Filters

12CS/50CS Series. Coreless Spin-on Filters

12CS/50CS Series Coreless Medium Pressure Filters

Parker Global Air Preparation System

AIR PREPARATION PRODUCTS. Table of Contents

DVX-DUPL DFS DVF-64, DVF-65 DVX. CLEANDiesel Vessels, Housings & Skid Systems DVF-64, DVF-65, DVX, DV, DVF, DFS

74 Series Combination Filter/Regulator and Lubricator Unit, featuring an in-line shut-off valve, and Quikclamp system.

PT Series Tank Top Filters

LX SERIES Low-Pressure Gas Compressors

Air Line Modulars Each component is engineered to connect easily modular FRL assemblies manual shut off

Stainless Steel FRLs

VALVES. Wilkerson. Filters, Regulators & Lubricators. dixonvalve.com Customer Service:

Product Data Sheet Filter Elements ERUF.. (for ultrafilter filter housings)

where nature and technology meet FILTRATION Solutions for filtration applications PETROGAS GAS-SYSTEMS BV

Filters for Compressed Air

P-SRF V STERILE AIR PLEATED DEPTH FILTER ELEMENTS

COMPRESSED AIR FILTERS AF SERIES Product overview

BGT Series. Low Pressure Filters

Compressed Air Filtration

LUBRICATORS. Lubricators 44

KLT and KLS Series Tank Top Return Line Filters

F200 SERIES COMPRESSED AIR FILTERS

Product - Specification

Rosedale Model HSS300 and HSS750 Single Cartridge Housings for Liquids

Smith Meter Truck Meter Packages Specifications

ARO-FLO SERIES FILTERS, REGULATORS AND LUBRICATORS

Parker Global Air Preparation System. A complete air preparation system

SUB-LINE FILTERS CONTENTS

Cipriani Harrison Valves Corp.

Section: G Crankcase Filtration

KleanLine Dry Gas Filters. Technical Bulletin

QUINCY QRD SERIES SINGLE-STAGE, 2-20 HP TWO-STAGE, 5-30 HP OIL-LESS RECIPROCATING COMPRESSORS

Compressed Air Filtration

Pneumatic. Prep-Air II 05 Series Air Preparation Units Filter, Regulator, Lubricator, and Modular Accessories Catalog 0708/USA

PDE2611TCUK-ca Air Preparation. Miniature FRL series. Miniature FRL Series. Parker Hannifin Corporation Pneumatic Division - Europe

Breathing Air Systems

Product Catalog. ...the Leader in Refrigeration Innovation

RAZOR. RAZOR HVLP Spray Guns

STEAM TRAPS. Float and Thermostatic Steam Traps (continued) Series C and X. Dimensions in. (mm)

1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S

Oil Solutions. TTF/BGTS Series Return In-Tank Filters. Global Filtration Technology. Filtration.

12CS Series Coreless Spin-on Filter Max. 75 l/min - 35 bar

LX SERIES Low-Pressure Gas Compressors

LX-SERIES Low-Pressure Gas Compressors

Air Preparation Units General Line, QIX, High Efficiency Filters, Dial & Precision Regulators. Catalog 0303

Suction Diffusers. Applications PROTECTION PUMP. Pressures to 790 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZE RANGES RATINGS

HYVAC PRODUCTS, INC. Capture Filters for Vacuum Pump Exhaust

ECOCLEAN. Compressed Air Filters

Today Numatics is proud to be a part of the Industrial Automation Division of Emerson Electric Co.

WSO Mist Collectors. cáäíê~íáçå=qéåüåçäçöó Ñçê=jáëí=`çääÉÅíáçå

Odor Removal Filter. Model. Note) 1 8, , , , 3 4. Model/Free Standing Type AMF (2B)JIS 10K FF flange

FTV-S (Straight) & FTV-A (Angle Body) Tri-Service Valve

Single-Stage Rotary Screw Air Compressors

I-4057-F CleanAir Air Control Equipment. Accessories for superior spray finishing. Filters Regulators Gauges Valves WATERBORNE COMPATIBLE

Manufacturers of Premium Pneumatic Controls since 1921 ROSS CONTROLS ROSS CONTROLS ROSS CONTROLS

Includes Dry Gas Design. Performance Enhanced with PEACH Cartridge Technology FILTRATION. All Rights Reserved Patent Pending I X H E L A P P L

KSI Filtertechnik GmbH Siemensring D Willich Tel Fax

A LEADING MANUFACTURER OF ABSOLUTE RATED FILTERS

Your Global Source for Today s Most Popular Solenoid Valves

CASH VALVES TYPE G-4 PRESSURE REGULATORS

Sullair: An Industry Leader

3 30 HP RECIPROCATING AIR COMPRESSOR. PL-Series

Nirvana hp Variable Speed Drive Rotary Screw Compressors. The Next Generation of Compressed Air

EG Series Screw Air Compressors

SULLAIR Single-stage Rotary Screw Air Compressors

SULLAIR Single-stage Rotary Screw Air Compressors

CAUTION: NOT INTENDED FOR STREET USE HOW TO USE THIS CATALOG WE LOVE RACING

Liquid Filtration Product Brochure

Transcription:

MIS SERIES Mist Eliminator The ircel MIS Mist Eliminator (300-8000 scfm) provides a full line of mist eliminators to effectively remove oil, solids and water from your compressed air system. In addition, this technology can serve as an efficient prefilter and contaminant separator for refrigerated and desiccant compressed air dryers. y reducing the liquid loading potential and preventing liquid slugs from reaching the dryer, it will extend the life of your refrigerated dryer s heat exchanger or the life of desiccant in regenerative dryers. MIS-1500 MIS Series Features Low pressure differential P 0.5-1.0 psi @ rated capacity under typical conditions. Long service life. Pressure vessel SME U Stamped National oard Registered. RN available upon request. Low pressure drop, maximum filter area and dirt capacity. Hinged flange and lift lug standard on closure flanges. Service access without breaking connections. Rugged enameled steel. onnections sizes from 2 to 10-inch NSI flange. Standard differential pressure gauge on all models. Optional zero-loss auto drain. White enamel interior coating. MIS Series Elements The ircel MIS Mist Eliminator features an element with patent pending urethane threaded end. This unique design requires no internal loose parts and no internal housing center core. This provides easy, hassle-free element changeout and reduces the overall initial unit shipping weight, saving on freight costs. The element is designed with optimum pleat spacing and fin depth to provide unsurpassed low differential pressure, dirt holding capacity, and efficiency. Filtration efficiency and permeability are based on independent laboratory testing by Interbasic Resources, Inc. Sustainable Energy Savings Pressure rop Reduces ompressor HP 4% per 8 PSI rop For every 8 psi pressure drop, compressor horsepower efficiency will be reduced by 4%. Therefore, the annual energy cost to run a typical 100 hp compressor with 85% efficiency compressor/motor can be figured as follows: onventional Filter: $0.07/KW-hr x 8760 hours x 103.3 KW x 4% = $2533.74 Mist Eliminator: $0.07/KW-hr x 8760 hours x 103.3 KW x 0.5% = $316.72 (1 psi pressure drop = 0.5% compressor HP reduced) MIS SERIES Recommended Installation That s a savings of $2217.02 per year. Locating a mist eliminator downstream from the compressor effectively lengthens the maintenance cycle on all elements, significantly reducing costs of system maintenance. High efficiency pleated construction. High efficiency needled polyester outer layer particulate removal. Installed differential pressure gauge and optional zero air-loss drain valve. Two stage borosilicate glass coalescing media. Mist Eliminator* Unique threaded element design (patent pending) requires no internal loose parts and no internal housing center core. The filter element will collect particles greater than 1 micron with 99.5% efficiency. Particles 0.5 micron in size will be filtered at an efficiency of 99.3%. Special HE (958 media) element available for 0.1 micron particles filtered at an efficiency of 99.99%. ir ompressor ir or Water ooled ftercooler Separator ir Receiver (Wet) ir ryer

MIS SERIES TEHNIL SPEIFITIONS MIS SERIES Model omparison Model apacity 1 (SFM) onn. (NSI) OH O Service Space Weight (lbs) Maximum Pressure (psig) Optional Zero ir- Loss Element Model Number MIS-300 300 2 36 8-5/8 16 10 120 250 /F MIS-300E MIS-500 500 2 40 8-5/8 16 16 150 250 /F MIS-500E MIS-1000 1000 3 48 8-5/8 20 20 180 250 /F MIS-1000E MIS-1500 1500 4 52 10-3/4 20 20 300 250 /F MIS-1500E MIS-2000 2000 4 54 10-3/4 20 24 325 250 /F MIS-2000E MIS-3000 3000 6 60 12-3/4 24 26 400 250 /F MIS-3000E MIS-4500 4500 6 64 12-3/4 24 26 500 250 /F MIS-4500E MIS-6500 6500 8 78 16 28 36 850 250 /F MIS-6500E MIS-8000 8000 10 88 20 32 36 1200 250 /F MIS-8000E 1 apacity rated at 100 psig operating pressure, 100 F inlet temperature. /F - onsult Factory Maximum working pressure: 250 psig over style: lind flange Operating temperature range: -20 F to 200 F arbon steel leg height: 12 (included in OH dimension above) ue to a continuous program of product improvement, specification and dimensions are subject to change without notice. MIS SERIES apacity orrection Factors To Size the Mist Eliminator apacity for ctual onditions djusted apacity = scfm x 1 x 2 To calculate the capacity of a given mist eliminator based on non-standard operating conditions, multiply the standard capacity by the appropriate correction factor. EXMPLE: Mist Eliminator Model: MIS-1000 Standard apacity: 1000 scfm ctual Operating onditions: 80 psig inlet pressure: 1 = 0.83 120 F inlet temperature: 2 = 0.94 djusted apacity = 1000 scfm x 0.83 x 0.94 = 780 scfm The published standard capacities for compressed air mist eliminators are based on 100 psig inlet pressure and 100 F inlet temperature. When these conditions vary, a given mist eliminator will be able to filter either more or less compressed air than its standard capacity. There are two ways in which this information can be used. The first is to start with a specific mist eliminator size and recalculate its capacity based on the known operating conditions using the correction factors given below. The other, with a given set of operating conditions, is to select the proper mist eliminator size based on applying the correction factors to the flow rate. Examples based on applying the correction factors are shown below. apacity correction factors for differing system air pressure (1) System Pressure (psig) 20 40 60 80 100 12 140 160 180 200 220 240 250 orrection Factor 0.30 0.48 0.65 0.83 1.00 1.17 1.35 1.52 1.70 1.87 2.05 2.22 2.31 To Select the Mist Eliminator for ctual onditions djusted apacity = scfm/1/2 To choose a mist eliminator based on a given flow at non-standard operating conditions, divide the given flow by the appropriate correction factors. EXMPLE: Given Flow: 1000 scfm ctual Operating onditions: 80 psig inlet pressure: 1 = 0.83 120 F inlet temperature: 2 = 0.94 djusted apacity = 1000 scfm / 0.83 / 0.94 = 1282 scfm djusted Mist Eliminator Model Size: MIS-1500 apacity correction factors for differing system air temperature (2) System Temperature ( F) -20 0 20 40 60 80 100 120 140 160 180 200 orrection Factor 1.52 1.41 1.31 1.22 1.14 1.07 1.00 0.94 0.88 0.83 0.79 0.75 http://airtec.global irtec Global 1100 NW Loop 410 San ntonio, TX 78240 US PHONE +1 (210) 632-6320 SLES INFORMTION support@airtec.global

F SERIES High Efficiency ompressed ir Filters Versitile esign ircel s F series high efficiency filters include smart design features and innovative technology to provide a compressed air filtration solution for a wide range of applications. ircel s unique F series high efficiency filters are designed to combine high performance, energy savings, flexibility and optimum reliability. Top ap Unique push-fit design and double O-ring seal for simple and secure installation. Multi-layer Filtration eep bed multi-wrap borosilicate glass microfiber with stainless steel support cylinders and a polyester needle felt sleeve. End ap urable and non-corrosive glass filled nylon cap which is attached to the element with a multi-part urethane resin. http://airtec.global/ irtec Global 1100 NW Loop 410 San ntonio, TX 78240 US PHONE +1 (210) 632-6320 SLES INFORMTION support@airtec.global

FETURES N ENEFITS aptive Piston Type O-Ring nnular Seal between head and bowl to prevent leaks External Ribs for easy service/ bowl removal High Quality luminum onstruction castings 100% leak-tested elta-p Gauge (standard) The dual-sided P gauge face is not pressurized. Unique magnetic sensor ensures superior performance. Pop-up P Indicators (optional) Nylon pop-up is available as a lower cost option. Remote ontact P larm (optional) ry contacts close at 6 psid to send a notification signal to a bell, light, or control panel. an be field installed. Modular NPT onnections option to bolt up to three filters together with High Nitrile O-ring connection to save space, offer ease with installation and eliminate leaks Only 4-7 clearance required for element removal Flat Spot to aid bowl removal Large apacity ondensate sump with space to install internal float drain Internal Ribs to secure element in-place and form quiet-air zone to prevent condensate re-entrainment Hexagon on ottom to aid in easy bowl removal utomatic Internal Float as standard ESSORIES Threaded NPT Side and ottom Port for external auto or manual drain ottom dapter Plate (1000-1500 scfm) Removable drain adapter for ease of float drain maintenance. Simple disconnect of external drain when element is changed. Mounting rackets llows convenient wall mounting of single or multiple filters. Ring Spanner ids in easy bowl removal. Manual s vailable for all models. onnecting Kits vailable for models 20-1500 scfm. Port Plates llows for easy conversion from standard port size to match larger pipe size and reduce pipe fittings. Prevents costly oversizing of filters to pipe size.

F SERIES TEHNIL SPEIFITIONS Filter Flow rate imensions inches (mm) NPT connections Weight Replacement model scfm Nm 3 /h E In/Out Side ottom** lbs element model F20[*] 20 34 2.83 (72) 1.38 (35) 7.32 (186) 2.95 (75) N/ 1/4 N/ 1/4 1.4 20[*]E F30[*] 30 51 2.83 (72) 1.38 (35) 7.32 (186) 2.95 (75) N/ 3/8 N/ 1/4 1.4 30[*]E F65[*] 65 110 4.33 (110) 1.50 (38) 10.75 (273) 5.98 (152) 1.30 (33) 1/2 1/4 1/4 5.4 65[*]E F75[*] 75 128 4.33 (110) 1.50 (38) 10.75 (273) 5.98 (152) 1.30 (33) 3/4 1/4 1/4 5.4 75[*]E F100[*] 100 170 4.33 (110) 1.50 (38) 14.09 (358) 5.98 (152) 1.30 (33) 1 1/4 1/4 6.1 100[*]E F150[*] 150 255 4.33 (110) 1.50 (38) 14.09 (358) 5.98 (152) 1.30 (33) 1 1/4 1/4 6.0 150[*]E F225[*] 225 382 5.75 (146) 2.01 (51) 19.06 (484) 6.50 (165) 1.65 (42) 1 1/2 1/2 1/4 12.2 225[*]E F300[*] 300 510 5.75 (146) 2.01 (51) 19.06 (484) 6.50 (165) 1.65 (42) 1 1/2 1/2 1/4 12.3 300[*]E F450[*] 450 765 5.75 (146) 2.01 (51) 19.06 (484) 6.50 (165) 1.65 (42) 2 1/2 1/4 12.3 450[*]E F650[*] 650 1105 5.75 (146) 2.01 (51) 26.97 (685) 6.50 (165) 1.65 (42) 2 1/2 1/4 14.8 650[*]E F1000[*] 1000 1700 9.06 (230) 2.68 (68) 28.43 (722) 7.01 (178) 1.65 (42) 3 1/2 1/4 40.6 1000[*]E F1250[*] 1250 2125 9.06 (230) 2.68 (68) 33.23 (844) 7.01 (178) 1.65 (42) 3 1/2 1/4 44.1 1250[*]E F1500[*] 1500 2550 9.06 (230) 2.68 (68) 39.06 (992) 7.01 (178) 1.65 (42) 3 1/2 1/4 48.3 1500[*]E Notes * Fill in element grade (FP5, PF1, PF01, and reverse flow RPF1) to appropriate model number. ** With internal float drain removed. 0.69 (18mm) 2.81 (71mm) 2.81 (71mm) E E F20[*] to F30[*] F65[*] to F650[*] F1000[*] to F1500[*] oalescing Filters Vapor Filter Grade FP5 PF1 / RPF1 (reverse flow) PF01 Particle removal 5.0 micron 1.0 micron 0.01 micron 0.01 micron Maximum carryover at 68 F / 20 5 ppm 0.1 ppm 0.01 ppm 0.003 ppm Recommended temperature 100 F / 38 100 F / 38 100 F / 38 77 F / 25 Maximum temperature 248 F / 121 248 F / 121 248 F / 121 122 F / 50 Pressure drop (clean and dry) 0.4 psid / 30 mbar 1.0 psid / 70 mbar 1.5 psid / 100 mbar 1.0 psid / 70 mbar Pressure drop (saturated) 1.0 psid / 70 mbar 2 psid / 140 mbar 3.0 psid / 210 mbar N/ Pressure drop (change element) 6.0 psid / 400 mbar 6.0 psid / 400 mbar 6.0 psid / 400 mbar see note Element media orosilicate Glass Microfiber arbon impregnated paper Maximum working pressure 232 psig / 16 barg (300 psig / 20 barg without auto float drain) Housing material High quality aluminum Note: ctivated charcoal () filters must not operate in oil saturated conditions and will not remove certain types of gases including carbon monoxide and carbon dioxide. hange interval depends on application. Please contact your distributor. orrection Factors For maximum flow rate, multiply model flow rate shown in the speciation chart by the correction factor corresponding to the working pressure. See specifications for maximum pressure. Note: To reduce pressure drop by 50%, reduce flow rate by 30%. Operating Pressure (psig) 10 20 30 40 50 60 70 80 90 100 110 125 150 175 200 225 250 275 300 orrection Factor 0.32 0.45.055 0.64 0.71 0.78 0.84 0.90 0.95 1.00 1.05 1.12 1.22 1.32 1.41 1.49 1.58 1.65 1.73