SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Similar documents
SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

SmartPro Medical-Grade UPS, Line Interactive, Lithium Battery, 6 Outlets - 230V, 1kVA, 750W, Full Isolation

MODEL NUMBER: APS3636VR

3000W APS X Series 24VDC 230V Inverter/Charger with Pure Sine-Wave Output, Hardwired

MODEL NUMBER: APS2424

1250W APS X Series 12VDC 230V Inverter/Charger with Auto Transfer Switching, 2 C13 Outlets

MODEL NUMBER: APS750. Highlights. Package Includes. Description

MODEL NUMBER: APS2012

2400W APS INT Series 24VDC 230V Inverter/Charger with Auto-Transfer Switching, Hardwired

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

750W PowerVerter RV Inverter/Charger with Hardwire Input/Output

MODEL NUMBER: APS2448UL

EFFEKTA Power Supplies

1250W 12VDC PowerVerter Ambulance/EMS Inverter/Charger with 2 Hospital Grade Outlets

On-line, Single Phase, Double Conversion UPS

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Series 120/120VAC Universal Tower/Rack Mount

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

Features and Benefits

PowerValue 11/31 T kva

Technical Data Sheets

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Technical data sheets

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

3 Uninterruptible Power Systems

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

D Series: UPS UPTO - 300KVA - Three / Three Phase

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

TECHNICAL DATA SHEET KVA UPS Systemss

Technical data sheets

Technical Data Sheets

Installation and Operation Back-UPS BX550CI-CN

Technical Data Sheets

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Technical Data Sheets

Technical Data Sheets

Installation and Operation Manual Back-UPS BR800/1100CI-IN

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Aurora Single Phase Emergency Lighting Inverters

TLE Series UPS 400/500 kw With eboost Technology

TLE Series UPS 750/1000 kw With eboost Technology

Model #: APS3636VR. 36V DC or 120V AC input; 120V AC output (hardwired)

Master DIALOG INDUSTRY RANGE

Up to 98% efficient under full load Similar runtimes to the previous 3u model

TLE Series UPS 160/200/225/250 kw with eboost Technology

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

ELEKTRA SERIES I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 500KVA (3/3) Mission Critical & I.T Grade UPS

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Uninterruptible Power Systems

MKN-DSP SERIES - THREE PHASE

Technical Data Sheets

PowerVerter 750W RV Inverter/Charger with Hardwire Input/Output

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

3 Uninterruptible Power Systems

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

UPS SYSTEMS PDUs SURGE PROTECTORS POWER INVERTERS DATACENTER UPS. Product Catalog

SecureUPS On-Line 120V AC Output, 1300VA

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Model #: RV1012ULHW. 12V DC or 120V AC input; 120V AC output (hardwired)

Model #: APS V DC or 120V AC input; 120V AC output (hardwired) Auto Transfer Switching option for battery backup / UPS operation

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

» Sophisticated» Reliable» Intelligent

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

S2000 PRODUCT RANGE. Ultra compact

POWER NEVER ENDS UPS SOLAR INVERTER STANDBY UPS LINE INTERACTIVE UPS ONLINE UPS OFF-GRID INVERTER ON-GRID INVERTER WITH ENERGY STORAGE ACCESSORY

Options & service. Additional 9355 options. Proven warranty and support services. Extensive service options for enhanced reliability.

POWER kva

SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS

Protection and conditioning against all forms of power anomalies.

TECHNICAL SPECIFICATIONS

Transcription:

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SVT20KX Highlights On-line double-conversion topology, VFI operation Automatic and Manual Bypass for enhanced reliability Optional ECO mode for high-efficiency operation Internal batteries and expandable runtime options Paralleling capability of up to 3 units Package Includes SVT20KX SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS (2) RS-232 cables 6-pin current sharing cable Owner s manual Description The SVT20KX SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS with IGBT technology provides battery backup and AC power protection against power disturbances that can damage electronics or destroy data. It s recommended for critical IT or corporate infrastructure, telecom, LAN/WAN, security and emergency, financial and light industrial applications. The SVT20KX s Voltage and Frequency Independent(VFI) design allows continuous operation at any supported voltage at either 50 or 60 Hz. Zero transfer time to battery mode ensures no disruption to the attached loads. Automatic and Manual Bypass keeps connected equipment powered even during overloads and UPS maintenance. IGBT inverter technology produces output power with less than 2% total harmonic distortion(thd) to keep connected equipment functioning at its peak. A 3:1 crest factor safely supports a variety of loads, even those with wildly fluctuating power demands. Managing the SVT20KX is simplified through the interactive front-panel LCD interface, which displays critical operating conditions and diagnostic data, such as load levels, available runtime, alarm status, battery charge, and voltage and frequency values. Four LEDs indicate bypass, line, battery and fault modes. A serial port allows connection to Tripp Lite s free local shutdown agent. A built-in card slot supports WEBCARDLX or RELAYCARDSV for network interface and remote monitoring and control. The SVT20KX s reduced size and small footprint save valuable space. Features VFI True On-Line Double-Conversion 3-Phase UPS System Provides fully regulated sine wave AC output for critical telecom, network, security, financial, corporate and light industrial applications +/-1% output voltage regulation in online and battery modes High 0.9 power factor offers 20kVA/18kW output capacity, allowing for more connected devices Selectable 380/400/415V output voltage Wide input voltage window(305 478V) minimizes battery use and prolongs battery life 1 / 6

Reliable Battery Backup with Expandable Runtime Supports half load for 11 min. and full load for 4 min. Zero transfer time suitable for advanced network applications Expandable runtime with optional external battery packs, such as Tripp Lite s BP240V135 Restarts automatically after lengthy power outages IGBT Inverter Technology Produces output power with less than 2% THD to keep connected equipment functioning at its peak Low <6% THDi input rating and advanced IGBT rectifier enables 1:1 Generator Sizing, eliminating costly oversizing requirements for generators, breakers and cables Paralleling Capability Connect up to 3 units in parallel configuration for increased capacity and fault tolerance Automatic and Manual Bypass Increases system reliability Allows maintenance without removing power from attached loads ECO Mode Operates at efficiency levels as high as 98.8% when input line conditions are favorable SNMP/Web Capability Slot for WEBCARDLX network interface or RELAYCARDSV relay card for remote monitoring and control options Communications Ports DB9 and EPO ports offer local monitoring and shutdown options Small-Footprint Tower Design Reduced-size black tower case saves valuable floor space Matching external battery cabinets enable extended runtime options Specifications OUTPUT Output Volt Amp Capacity (VA) 20000 Output kva Capacity (kva) 20 Output kw Capacity (kw) 18 Output Capacity Details Supports up to 100% load continuously in double conversion mode; Supports 100-110% load for 10 minutes, 110 to 130% load for 1 minute and greater than 130% for 1 second before switching to bypass mode; Inverter mode is automatically restored as load levels are reduced to 70% or less; Configuration options support up to 3 SVT20KX systems wired in parallel for increased capacity or fault-tolerant, redundant operation Power Factor 0.9 Crest Factor 3:1 2 / 6

Nominal Output Voltage(s) Supported Frequency Compatibility Output Voltage Regulation (Line Mode) Output Voltage Regulation (Economy Line Mode) Output Voltage Regulation (Battery Mode) Output Receptacles Output AC Waveform (AC Mode) Output AC Waveform (Battery Mode) 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye 50 / 60 Hz +/- 1% +/-11V of selected nominal output voltage (220V: 209-231V; 230V: 219-241; 240V: 229-251V) +/- 2% Hardwire Pure Sine wave Pure Sine wave INPUT Rated input current (Maximum Load) 34.4A Nominal Input Voltage(s) Supported 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye Nominal Input Voltage Description 3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G) UPS Input Connection Type Input Circuit Breakers Input Phase Power Factor (Input) THDi Hardwire 63A (3 pole) 3-Phase.99PF (100% load) <6% (100% load) BATTERY Full Load Runtime (min.) Half Load Runtime (min.) Expandable Battery Runtime External Battery Pack Compatibility 4 min (18kW) 11 min. (9kW) Supports extended runtime optional external battery packs BP240V135 DC System Voltage (VDC) 240 Battery Recharge Rate (Included Batteries) Expandable Runtime 4 hours to 90% (Internal batteries) Yes VOLTAGE REGULATION Voltage Regulation Description Overvoltage Correction Undervoltage Correction Online, double-conversion power conditioning maintains output within 1% of the selected nominal voltage in online mode Corrects overvoltage conditions to 520V (50% load) and 478V (100% load) Corrects brownout conditions to 110V (50% load) / 305V (100% load) 3 / 6

USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display Switches Audible Alarm LED Indicators LCD DISPLAY: offers a variety of graphical, text and numeric information to indicate a wide range of UPS operation and fault / warning conditions, including current operating mode, alarm status, load level, battery charge, input / output voltage & frequency, estimated runtime and more (see user manual for a detailed listing) ON / ENTER BUTTON: turns the UPS on and confirms a selection from the settings menu; OFF / ESC BUTTON: turns off the UPS and returns to the previous item in the settings menu; TEST / UP BUTTON: initiates UPS self-test operation and advances to the next item in the settings menu; MUTE / DOWN BUTTON: silences the audible alarm and advances to the previous item in the settings menu; Press TEST/UP & MUTE/DOWN buttons simultaneously for 1 second to enter or exit the settings menu (See user manual for detailed information) Alarms warn users of a variety of operational conditions: BYPASS MODE (beeps every 2 seconds), BATTERY MODE (beeps every 4 seconds), FAULT MODE (beeps continuously), OVERLOAD (beeps twice per second), OTHER WARNINGS (beeps once per second), FAULT (beeps continuously); All alarms can be silenced, except OVERLOAD & OTHER WARNINGS conditions 4 LEDs report BYPASS / LINE / BATTERY / FAULT modes PHYSICAL Installation Form Factors Supported with Included Accessories Primary Form Factor UPS Power Module Dimensions (hwd, in.) UPS Power Module Dimensions (hwd, cm) Tower Tower 33.9 x 9.8 x 32 86.11 x 24.89 x 81.28 UPS Power Module Weight (lbs.) 392 UPS Power Module Weight (kg) 177.81 UPS Shipping Dimensions (hwd / in.) 41.74 x 14.96 x 36.22 UPS Shipping Dimensions (hwd / cm) 106.02 x 38.00 x 92.00 Shipping Weight (lbs.) 430 Shipping Weight (kg) 195 Cooling Method UPS Housing Material UPS Power Module Dimensions (Height x Width x Depth, mm) UPS Shipping Dimensions (Height x Width x Depth, mm) Fans Steel 862 x 250 x 813 1060 x 380 x 920 Primary UPS Height (mm) 861 Primary UPS Width (mm) 249 Primary UPS Depth (mm) 813 Shipping Height (mm) 1060 Shipping Width (mm) 380 Shipping Depth (mm) 920 4 / 6

ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity 0 to +40C (32-104F) 0 to +35C (32 to 95F) with battery; -15 to 60C (5 to +140F) without battery 5 to 95%, non-condensing Operating Elevation (ft.) < 3000ft (Capacity de-rates by 1% for every 330ft over 3000) Audible Noise <65dBA front side 1M Operating Elevation (m) < 1000m (Capacity de-rates by 1% for every 100m over 1000) COMMUNICATIONS Communications Interface Network Monitoring Port Description Communications Cable DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface Card accessory slot also supports network interface and relay card options DB9 cabling included LINE / BATTERY TRANSFER Transfer Time Low Voltage Transfer to Battery Power (Setpoint) High Voltage Transfer to Battery Power (Setpoint) Zero transfer time in ONLINE MODE (0ms); ECONOMY MODE: 7ms from AC to Battery mode / 0.6ms from Battery to AC mode 110V (50% load) / 305V (100% load) 520V (50% load) / 478V (100% load) SPECIAL FEATURES Grounding Lug Cold Start (Startup in Battery Mode During a Power Failure) High Availability UPS Features Green Energy-Saving Features Yes Cold-start operation supported Automatic inverter bypass; Manual bypass switch High efficiency economy mode operation CERTIFICATIONS UPS Certifications CE UPS Certification Details EN 62040-1-1 (Safety); EN 62040-2 (Category C3) WARRANTY Product Warranty Period (International) 1-year limited warranty 2016 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies: 5 / 6

http://www.tripplite.com/products/product-certification-agencies 6 / 6