LED Driver Linear / area fixed output

Similar documents
LED control gear Compact fixed output

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area dimming

Emergency lighting units EM powerled

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

Emergency lighting units EM powerled

PC T8 TEC, W PC TEC

FL ballasts Electronic fixed output. PC T5 TOP lp, W PC TOP T5

Driver LC 17W mA flexc C EXC EXCITE series

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

Emergency lighting units EM powerled

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Emergency lighting units EM powerled

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM powerled

Emergency lighting units EM converterled

Emergency lighting units EM converterled

Emergency lighting units EM converterled

FL ballasts Electronic fixed output

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

FL ballasts Electronic fixed output. PC TC PRO 1/2x9 70 W PC PRO compact

FL ballasts Electronic fixed output

FL ballasts Electronic fixed output. PC TCL PRO, W PC PRO compact

LED light engines ready2apply. Engine SLA AC G2 50mm SNC Engine SLA ESSENCE

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units PC COMBO

Electronic ballasts for fluorescent lamps Professional electronic ballast

SLA DC. LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

Emergency lighting units PC COMBO

FL ballasts Electronic fixed output PC T8 PRO, W PC PRO T8

Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver

Emergency lighting units EM powerled

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

PC T8 PRO, W T8 fluorescent lamps

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM powerled. EM powerled BASIC 4W Emergency lighting LED Driver

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Emergency lighting units EM powerled

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

Emergency lighting units EM powerled

LED light engines LED linear / area. Module STARK QLE G3 SELECT Modules QLE EXCITE

LED light engine / OLED LED linear / area

PHASED OUT. LED light engine / OLED LED linear / area. Module QLE G1 488x239mm 2500lm ADV-SE Modules QLE

PHASED OUT. LED light engine / OLED LED linear / area. Module LLE G3 16x140mm 325lm ADV, LLE G3 16x280mm 650lm ADV Modules LLE ADVANCED

Emergency lighting units EM powerled

Emergency lighting units EM LED Light Engines

LED modules LED linear / area

LED light engines LED linear / area

Electronic ballasts for fluorescent lamps Multi-lamp ECG. PC T5 PRO-M lp, W T5, T8, compact (CFL) and T5c circular fluorescent lamps

Emergency lighting units EM series

Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver

Emergency lighting units EM Inverter

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

LED light engine / OLED LED linear / area. Module STARK LLE PREMIUM Modules LLE

Tunable White LED linear / area. Module LLE G2 PREMIUM LLE PREMIUM

LED light engine / OLED LED linear / area. Module LLE PREMIUM CRI90 LLE PREMIUM

LED light engines LED linear / area

LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC STARK LLE

LED modules LED linear / area

LED light engine / OLED LED linear / area

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE , CLE CLASSIC Modules CLE

ELEMENT. Product family datasheet. Constant Voltage Non dimmable

PHASED OUT. LED light engine / OLED LED compact. Module CLE G2 190mm 1500lm ADV EM Modules CLE

LED light engine / OLED LED compact

LED light engine / OLED LED compact

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE CLASSIC / CLE CLASSIC Modules CLE

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

LED light engines LED linear / area

Emergency lighting units EM powerled. EM powerled BASIC 15 W CLE Emergency lighting units LED

Emergency lighting units EM powerled. EM powerled BASIC 15 W CLE Emergency lighting LED Driver

LED light engines LED linear / area

LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC EM STARK LLE

Tunable White LED linear / area

LED modules LED linear / area

LED light engine / OLED LED compact. Umodule STARK CLE 360 CLASSIC EM STARK CLE

Emergency lighting units EM powerled

PHASED OUT. LED light engine / OLED LED compact. Umodule STARK DLE GEN2 CLASSIC STARK DLE

PHASED OUT. LED light engine / OLED LED linear / area. Umodule STARK LLE umodule LLE ADVANCED

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps

Emergency lighting units EM LED Light Engines. Module EM-ES 08/10/12 Mk2 EM LED linear / area

Emergency lighting units EM INVERTER

LED light engines LED linear / area

PHASED OUT. LED light engine / OLED LED compact. Module SLE G5 ART EXC Modules SLE EXCITE

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

LED light engine / OLED LED compact. Umodule SLE G4 FASHION EXC

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

PHASED OUT. LED / OLED Light Engine LED linear / area. Umodule STARK LLE STARK LLE

Emergency lighting units LED series

LED modules LED flexible. Module LLE FLEX G1 8mm EXC Modules LLE FLEX EXCITE

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule STARK QLE CLASSIC EM umodule STARK QLE PHASED OUT. Ordering data.

Transcription:

Driver LC 65W 4-7mA flexc lp ANCED series Product description Built-in constant current LED Driver Adjustable output current between 4 and 7 ma Max. output power 65 W Up to 94 % efficiency Nominal life-time up to, h For luminaires of protection class I and protection class II Temperature protection as per EN 6347--3 C5e 5-year guarantee Housing properties Low-profile metal casing with white cover Type of protection IP Interfaces Terminal blocks: 45 push terminals Functions Overtemperature protection Overload protection Short-circuit protection No-load protection Burst protection voltage kv Surge protection voltage kv (L to N) Surge protection voltage kv (L/N to earth) Typical applications For linear/area lighting in office applications È Standards, page 4 Wiring diagrams and installation examples, page 4 www.tridonic.com

Driver LC 65W 4-7mA flexc lp ANCED series Technical data Rated supply voltage AC voltage range Max. input current (at 3 V, 5 Hz, full load) 4 V 98 64 V.8 A Leakage current (at 3 V, 5 Hz, full load) < 45 µa Mains frequency Overvoltage protection Max. input power Typ. power consumption (at 3 V, 5 Hz, full load) Min. output power Max. output power 5 / 6 Hz 3 V AC, 48 h 75.6 W 75. W 57. W 65 W Typ. efficiency (at 3 V / 5 Hz / full load) 94 % λ (at 3 V, 5 Hz, full load).95 Output current tolerance ± 7.5 % Max. output current peak 3 output current + % Max. output voltage 33 V THD (at 3 V, 5 Hz, full load) < % Output LF current ripple (< Hz) ± 5 % Time to light (at 3 V, 5 Hz, full load) Turn off time (at 3 V, 5 Hz, full load) Hold on time at power failure (output).5 s.5 s s Ambient temperature ta (at life-time, h) 4 C Storage temperature ts -4... +8 C Dimensions L x W x H Hole spacing D 36 x 3 x mm 348 mm Ø4, Ordering data Type side fixing feature 36 6 348 Article number tc tc Packaging, carton Packaging, low volume 4, 7 3 Packaging, high volume Weight per pc. LC 65W 4-7mA flexc lp 8756 5 pc(s). 65 pc(s).,95 pc(s)..54 kg Specific technical data Type LC 65W 4-7mA flexc lp Test result at 7 ma. Output Min. forward current voltage Max. forward voltage Max. output power Typ. power consumption (at 3 V, 5 Hz, full load) Typ. current consumption (at 3 V, 5 Hz, full load) Max. casing Ambient I-out Resistor 4 temperature tctemperature ta max. 4 ma 43 V 3. V 8 W 34.5 W 599 ma 8 C -... +5 C - Type A 45 ma 43 V 3. V 44 W 5.8 W 679 ma 8 C -... +5 C - Type B 5 ma 43 V 3. V 6 W 68.7 W 748 ma 8 C -... +5 C - Type A 6 ma 43 V 75. V 65 W 74.5 W 77 ma 85 C -... +5 C - Type C 7 ma 43 V 35.7 V 65 W 75. W 775 ma 85 C -... +5 C open Output current is mean value. 3 Test result at 5 C. 4 Type A is a short circuit plug ( Ω). www.tridonic.com

ACCES- SORIES Plug for output current Product description Ready-for-use resistor to set output current value Compatible with LED Driver serie LC flexc ; not compatible with I- (generation ) and I- (generation ) Resistor is base isolated When using your own resistors, make sure the resistor must be isolated Resistor power.5 W Current tolerance ± % additional to output current tolerance Hot plug of the resistor is not permitted For detailed current setting see table Specific technical data of the respective LED Driver and chapter 3.8 Current setting Ordering data Type Article number Colour of X area Colour of Y area X Y 9 5,5 4,5 xxxx xxxx Marking 7,5 3,5 Resistor value 3,5 Packaging bag Weight per pc. Plug Type A YL 877 Yellow Yellow A. Ω pc(s).. kg Plug Type B YL 877 Yellow Black B 3.6 kω pc(s).. kg Plug Type C YL 8773 Yellow Purple C 8.7 kω pc(s).. kg www.tridonic.com 3

. Standards EN 555 EN 6-3- EN 6-3-3 EN 6347- EN 6347--3 EN 6547 EN 6384. Thermal details and life-time. Expected life-time Expected life-time Type ta 4 C 5 C 6 C LC 65W 4-7mA flexc lp The LED Driver is designed for a life-time stated above under reference conditions and with a failure probability of less than %. 3. Installation / wiring 3. Circuit diagram 4 V /5/6 Hz L N tc 75 C 85 C x Life-time, h 5, h x 3.4 Installation instructions The LED module and all contact points within the wiring must be sufficiently insulated against 3 kv surge voltage. Air and creepage distance must be maintained. 3.5 Wiring guidelines All connections must be kept as short as possible to ensure good EMI behaviour. Mains leads should be kept apart from LED Driver and other leads (ideally 5 cm distance) Max. lenght of output wires is m. Incorrect wiring can damage LED modules. To avoid the damage of the Driver, the wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, etc.). The current ion has to be installed in the accordance to the requirement of low voltage installation. 3.6 Replace LED module. Mains off. Remove LED module 3. Wait for seconds 4. Connect LED module again Hot plug-in or output switching of LEDs is not permitted and may cause a very high current to the LEDs. 3. Wiring type and cross section 3.7 Earth connection The earth connection is conducted as protection earth (PE). The LED Driver can be earthed via metal housing. If the LED Driver will be earthed, protection earth (PE) has to be used. There is no earth connection required for the functionality of the LED Driver. Earth connection is recommended to improve following behaviour. The wiring can be stranded wires with ferrules or rigid wires with a cross section of.5.5 mm². Strip 8.5 9.5 mm of insulation from the cables to ensure perfect operation of the push-wire terminals. wire preparation:.5.5 mm² 8.5 9.5 mm 3.3 Release of the wiring Press down the push button and remove the cable from front. Electromagnetic interferences (EMI) Transmission of mains transients to the LED output In general it is recommended to earth the LED Driver if the LED module is mounted on earthed luminaire parts respectively heat sinks and thereby representing a high capacity against earth. For Class I application, protection earth need to connected with the metal housing (bottom part). For Class II application, protection earth is no need to be connected, below scenarios should be considered: If the LED Driver housing is screw on a metal part inside the luminaires, both LED Driver and LED module must be isolated. If the LED Driver housing is screw on a plastic part inside the luminaires, the LED module need to be isolated. www.tridonic.com 4

3.8 Current setting 4 ma: Terminal and connected with Ω wire (max. 6 cm length) or resistor Plug Type A BR (article number: 877) Type A 45 ma: Terminal and connected with resistor Plug Type B BR (article number: 877) 4. Electrical values Test at 3 V 5 Hz. 4. Efficiency vs load 95,5 95, 94,5 Efficiency [%] 94, 93,5 Type B 93, 9,5 45 5 55 6 65 7 75 8 85 9 95 5 ma: Terminal and connected with Ω wire (max. 6 cm length) or resistor Plug Type A BR (article number: 877) 6 ma: Terminal and connected with resistor Plug Type C BR (article number: 8773) Type A Type C 4. Power factor vs load Power factor,99,985,98,975,97,965,96,955,95,945,94 45 55 65 75 85 95 4.3 Input power vs load 7 ma: All terminals open 3.9 Mounting of device Max. torque for fixing:.5 Nm/M4 Input power [W] 8 7 6 5 4 3 9 8 7 6 45 55 65 75 85 95 www.tridonic.com 5

4.4 Input current vs load Input current [ma] 8 75 7 65 6 55 5 45 4 35 3 5 45 55 65 75 85 95 4.5 THD vs load 6 5 THD [%] 4 3 45 55 65 75 85 95 4 ma 45 ma 5 ma 6 ma 7 ma 4.6 Maximum loading of automatic circuit breakers Automatic circuit breaker type C C3 C6 C B B3 B6 B Inrush current Installation Ø.5 mm.5 mm.5 mm.5 mm.5 mm.5 mm.5 mm.5 mm Imax Time LC 65W 4-7mA flexc lp 5 8 3 7 9 4 5.5 A 76 µs 4.7 Harmonic distortion in the mains supply (at 3 V / 5 Hz and full load) in % THD 3. 5. 7. 9.. LC 65W 4-7mA flexc lp < 8 < 5 < 5 < 4 < 3 < www.tridonic.com 6

5. Functions 5. Overtemperature protection The LED Driver will reduce the LED output current or it works in a pulsed light output mode if the temperature reaches a certain degree. 5. Short-circuit behaviour In case of a short circuit on the output side (LED) the LED Driver switches into hic-cup mode. After elimination of the short-circuit fault the LED Driver will recover automatically. 5.3 No-load operation The LED Driver works in burst working mode to provide a constant output voltage regulation which allows the application to be able to work safely when LED string opens due to a failure. 5.4 Overload protection If the output voltage range is exceeded the LED Driver will protect itself and LED may flicker. After elimination of the overload, the nominal operation is restored automatically. 6. Miscellaneous 6. Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 6598- Annex Q (informative only!) or ENEC 33-Annex A, each luminaire should be submitted to an isolation test with 5 V DC for second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance must be at least MΩ. As an alternative, IEC 6598- Annex Q describes a test of the electrical strength with 5 V AC (or.44 x 5 V DC). To avoid damage to the electronic devices this test must not be conducted. 6. Conditions of use and storage Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %) Storage temperature: -4 C up to max. +8 C The devices have to be within the specified temperature range (ta) before they can be operated. 6.3 Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services Life-time declarations are informative and represent no warranty claim. No warranty if device was opened. www.tridonic.com 7