Model CP470. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Similar documents
Model CP420/CP425. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Model GP5128. Triplex Ceramic Plunger Pump Operating Instructions / Manual

Models P470 / P490. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

MP Series. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual. Pump Models: MP4120 MP4124 MP4126 MP4130 MP4130HK MP4135

Models SP100W/SP100HK SP200W/SP351W

Models SP100W/SP100HK SP200W/SP351W

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Model GP5128. Triplex Ceramic Plunger Pump Operating Instructions / Manual

Model GP5128HS. Hydraulic Drive Pump. Triplex Ceramic Plunger Pump Operating Instructions / Manual

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Series CP200. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual. For Models: CP218 CP219 CP220 CP230

Models P532, P533 and P536

Models GP5132, GP5136, GP5142 & GP5145. Triplex Ceramic Plunger Pump Operating Instructions / Manual

Series. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual P200-18mm versions

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P

P Series. 22mm & 25mm Versions Models: P420A-5100 P420A-5111 P420A-5121 P P P P P

Models P420A-3100 & P420A-5100

Model. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual SP100W/SP351W

Models. SP100HT, SP100HTK and SP200HT. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Model GP7122. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Models P55W/P56W/P56W-0011/ P56W-0021/P56W Triplex Ceramic Operating Instructions/ Manual

Pump Model P Corrosion Resistant Pump

Models GP7545GB-180/ GP7555GB-180. Gearbox Versions for Pinion Shaft Drives

Models GP8045/GP8048. Triplex Ceramic Plunger Pump Models Manual

Model LP301A Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Model LP200, LP250 & LP250W-MT

GP8055, GP , GP8060, GP , GP8065

Models. P56HT and P56HTK. Triplex Ceramic Operating Instructions/ Manual

Models LP301A, LP301A-SSP LP301A-4000, LP600 and LP

Model GP7522. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Model GX Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Series P300. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual. For Models: P313 P314 P316 P317 P318 P319 P340

Models LP122A/LP123/LP255

P46W, P46W-HK, P46HT & P49W

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Model LP122A Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

P318, P321, P324, P327,

P300 Series - 16 & 18 mm versions. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Model GP8100-R REVERSE GEARBOX SERIES

Models GP7645GB-180/ GP7655GB-180. Gearbox Versions for Pinion Shaft Drives

GP7145(-SSP)/GP7255A(-SSP)

Model GP8035. Gearbox Version Shown. Triplex Ceramic Plunger Pump Models Manual

P300 Series - 16 & 18 mm versions. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

MP Series. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual. Pump Models: MP4120 MP4124 MP4135 MP4130 MP4130HK

Models P55W/P56W/P56W-HK/P56HT. Triplex Ceramic Operating Instructions/ Manual

Models GP8135 & GP8140

LP800 / LP900 / LP1000

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

REPAIR INSTRUCTION - MP4120-SWS/MP4124-SWS

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

MODELS CX10 and CX20 INDUSTRIAL PUMPS INSTRUCTIONS AND SERVICE MANUAL

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

Maintenance Instructions for All Models

All products subject to this warranty must be returned for examination, repair or replacement to:

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

Variable Speed Misting Pump Totally Enclosed Direct Drive MODEL HDE-1PH-230VFD

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

Single Post Caliper Brake VC500

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

DP DIAPHRAGM PUMP Parts & Instruction Manual

Stainless Steel Air Motor Conversion Kits

FCB-450, LCB-600, MCB-800

INTRODUCTION INSTALLATION

SAVE FOR CONSUMER INSTALLATION / OWNER S MANUAL. Includes: Tools: Mystic - Pull-Out Kitchen Faucet LKMY1041CR LKMY1041NK LKLFMY1041CR LKLFMY1041NK D 1

Stainless Steel Air Motor Conversion Kits

MetroPrime 22MPC Self-Priming Centrifugal Pump

MULTIPOSITION AIR CYLINDER

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS

TECHNICAL SERVICE MANUAL

Guardian Taper Grid Shaft Coupling

Installation and Maintenance Instructions

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Guardian Steel Gear Shaft Coupling

FS Series INSTRUCTION AND MAINTENANCE MANUAL: FS SERIES SHEAR BLENDER. Sanitary Mixing and Blending Equipment

3-POINT SPRAYERS. Operation, Service & Parts Manual For G50E. FORM: G50EBook.QXD

Read this entire manual before operation begins.

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Read this entire manual before operation begins.

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

Tri-Clover Manual and Air Actuated Fractional Valves

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

DAP-625S and DAP-875S

Service Guide JATCO Environmental Protection Tank Model J-7000

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Colt Series C400, C500

Repair Instructions and Parts List

QUALITY MISTING PUMPS

Pro Shot Grease Dispense Valve

Straight-Bore Clutch LSCC-32, 44, 54

AIR CHAMP PRODUCTS. User Manual. Sheave & Pilot Mount Clutch-Brake Model BCB-275 FORM NO. L F-0414 FORM NO. L F-0414

HR-20P Pneumatically Controlled Pressure Regulator

Guardian FH Flywheel Coupling

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

Transcription:

Model Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual CP470 Updated 06/17 Contents: Installation Instructions: page 2 Pump Specifications: page 3 Exploded View: page 4 Part List/Kits: page 5 Torque Specifications: page 5 Repair Instructions: pages 6-7 Dimensions: back page Warranty Information back page

INSTALLATION INSTRUCTIONS Operation Check oil level prior to starting and ensure trouble-free water supply. Important! The crankcase must be filled with synthetic motor oil of class SAE 0W 40 when pumping CO 2 under 0 C. Initial oil change after 50 operating hours and then every 500 hours, after 1 year if used less. Caution when operating in damp places or with high temperature fluctuations. Oil must be changed immediately should condensate (frothy oil) occur in the gear box. NPSH values must be observed. Maximum input pressure is 508 PSI (35 bar). The maximum suction head is 14.5 PSI (1 bar). Make sure that suction pulsation is sufficiently dampened - water column resonance must be avoided. Important! If the pump is not used for a long period of time, it is possible the seals (23/238) could become hard or brittle thus causing the pump to leak when put into operation. If this is the case, we recommend these seals be replaced every 4 years. Safety Rules A safety valve is to be installed in accordance with the guidelines for liquid spraying units so that the admissible operating pressure cannot be exceeded by more than 10%. Pump operation without a safety valve as well as any excess in temperature or speed limits automatically voids the warranty. When the pump is in operation, the drive shaft end and the coupling must be enclosed by a protective cover or a coupling bell. Pressure in the discharge line and pump must be at zero before any maintenance to the pump takes place. Shut off suction line. Disconnect fuses to ensure that the driving motor does not get switched on accidently. Make sure that all parts on the pressure side of the unit are vented before starting the pump. In order to prevent air, or an air-water mixture being absorbed and to prevent cavitation occurring, the pump NPSHR (=suction head) and water temperature must be respected. Cavitation and/or compression of gases lead to uncontrollable pressure-kicks which can ruin pump and unit parts and also be dangerous to the operator or anyone standing nearby. Giant Plunger Pumps are suitable for pumping clean water and other non-aggressive or nonabrasive media with a specific weight similar to water. Before pumping other liquids especially Inflammable, explosive and toxic media - the pump manufacturer must be consulted with regard to the resistance of the pump material. It is the responsibility of the equipment manufacture and/or operator to ensure that all pertinent safety regulations are adhered to. 2

Specifications Model CP470 U.S. Metric Volume... 9.25 GPM...35 L/min Discharge Pressure... 1740 PSI... 120 Bar Inlet Pressure... 14-500 PSI...1-35 Bar Stroke... 0.94...24mm Speed... Up to 750 RPM Plunger Diameter... 1.18...30mm Temperature of Pumped Fluids... -40 o F to 160 o F... -40 o C to 70 o F Inlet Ports... (1) x 1 BSP, (2) x 3/4 BSP Discharge Ports... (2) x 3/4 BSP Shaft Rotation... Top of pulley towards fluid end Crankshaft Diameter... 1.10...28mm Key Width... 0.31...8mm Shaft Mounting...Either side 1 Weight... 36.6 lbs....16.6 kg Crankcase Capacity... 30.4 fl.oz....0.9 Liter Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. 1 NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence. CP470 HORSEPOWER REQUIREMENTS RPM GPM 500 PSI 1000 PSI 1500 PSI 1740 PSI 350 4.32 1.5 3.0 4.5 5.2 450 5.55 1.9 3.8 5.7 6.7 550 6.78 2.3 4.7 7.0 8.1 650 8.02 2.8 5.5 8.3 9.6 750 9.25 3.2 6.4 9.6 11.1 HORSEPOWER RATINGS: The rating shown are the power requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above. We recommend a 1.15 service factor be specified when selecting an electric motor as the power source. To compute specific pump horsepower requirements, use the following formula: HP = (GPM X PSI) / 1450 3

Exploded View - CP470 Pump Note: Do not use mineral oil on seals and o-rings. Use silicone grease only. 4

ITEM PART DESCRIPTION QTY. 1 CP08377 Crankcase 1 2 CP08378 Oil Fill Plug with Gasket 1 3 CP06479 Crankcase cover 1 3A CP07186 Oil Sight Glass w/ Gasket 1 4 CP08380 O-Ring 1 5 CP07109 Oil Drain Plug, 1/2 BSP 1 5A CP06015 O-Ring for Oil Drain Plug 1 5B CP08092 Plug with Gasket 1 6 CP01010 Screw 4 6A CP01010-0400 Spring Washer 4 7 CP04739 Bearing Cover, Open 1 8 CP05291 Bearing Cover, Closed 1 8A CP05292 Shim, 0.1 mm 1-3 8B CP05293 Shim, 0.2 mm (May not be present) 1 8C CP05964 Shim, 0.15 mm (May not be present) 2 9 CP01016 O-Ring 2 10 CP07114 Screw with Washer 8 11 CP07459 Radial Shaft Seal 1 12 CP05350 Taper Roller Bearing 2 13 CP04741 Crankshaft 1 13A CP04742 Spacer Ring 1 14 CP08091 Fitting Key 1 15 CP08390 Connecting Rod Assembly 3 15A CP07311 Screw with Washer 6 16 CP05961 Plunger Assy., (16A-16G) 3 16A CP05352 Plunger Base 3 16B CP05962 Plunger Pipe 3 16D CP08399 Tension Screw 3 Plunger Packing Kit - # CP09718 Item Part # Description Qty. 20A CP08059 O-Ring, EPDM 3 21A CP07150-0003 O-Ring, EPDM 6 23 CP06931-0020 Grooved seal 6 24 CP06932 Support Ring 3 25B CP02009-0003 O-Ring, EPDM 2 CP470 PUMP PARTS LIST CP470 PUMP REPAIR KITS ITEM PART DESCRIPTION QTY. 16E CP07023 O-Ring 3 16F CP07203 Backup Ring 3 16G CP07258 Copper Washer 3 17 CP06790 Crosshead Pin 3 19 CP08366 Oil Seal 3 20 CP06928 Gear Seal Adapter 3 20A CP08059 O-Ring 3 21 CP06929 Seal Sleeve 3 21A* CP07150-0003 O-Ring, EPDM 6 22 CP06930 O-Ring 3 23 CP06931-0020 Grooved Seal 6 24 CP06932 Support Ring 3 25 CP06933 Intermediate Casing 1 25A CP05934 Thread Plug 2 25B* CP02009-0003 O-Ring, EPDM 2 26 CP06935 Manifold, Brass 1 27A CP06936-0003 Valve Assembly 6 27 CP06937 Valve Seat 6 28 CP06938 Valve Plate 6 29 CP06377-0100 Valve Spring 6 30 CP06939 Spring Tension Cap 6 31* CP07212-0003 O-Ring, EPDM 6 32 CP08373 Plug 3 33* CP07214-0003 O-Ring, EPDM 3 34 CP06494 Inner Cap Screw 8 36 CP07703 Plug, 3/4 BSP 3 *The EPDM (Buna) O-Rings must not come into contact with mineral oil or mineral grease. Use silicone grease only. Valve Assembly Kit - # CP09719 Item Part # Description Qty. 27A CP06936-0003 Valve Assembly 6 33 CP07214-0003 O-Ring, EPDM 3 Oil Seal Kit - # 09306 Item Part # Description Qty 19 CP08366 Oil Seal 3 CP470 PUMP TORQUE SPECIFICATIONS Item Part # Description Torque Amount 3A CP07186 Oil Sight Glass 106 in.-lbs (12 Nm) 5 CP07109 Oil Drain Plug 59 ft.-lbs. (80 Nm) 5B CP08092 Plug 59 ft.-lbs. (80 Nm) 6 CP01010 Screw 110 in.-lbs. (12.5 Nm) 10 CP07114 Screw w/washer 132 in.-lbs. (15 Nm) 15A CP07311 Screw with Washer 97 in.-lbs. (11 Nm) 16D CP08399 Tension Screw 247 in.-lbs. (28 Nm) 32 CP08373 Plug 132 in.-lbs. (15 Nm) 34 CP06494 Cap Screw 22 ft.-lbs. (40 Nm) 5

To Check Valves REPAIR INSTRUCTIONS - CP470 Note: Do not use mineral oil on seals and o-rings. Use silicone grease only. 30 29 28 1. Remove plugs (32) with socket wrench. 2. Remove the exposed spring tension cap (30) from valve seat by pushing it sideways with a screwdriver. Remove spring tension cap (30), valve spring (29), and valve plate (28). 3. Pull out valve seat (27) and O-ring (31) with a valve puller. Check O-ring for wear. 4. Remove hexagon socket screws (34) and remove valve casing (26) by pulling them frontwise over the plungers (16) 5. Using two screwdrivers, remove seal case (21) lmportant: When extracting the valve holders (22), make sure not to scratch the outer bore diameter as this is a sealing To Check To Check Seals and Plunger Pipe 7. Remove hexagon socket screws (34). 6. The exposed suction valve parts are to be removed the same way as the discharge valves as described above. Check valve components for wear and damage. Check O rings (21A and 31). Replace worn parts. Reassemble in same order. Coat new O-Rings with silicone grease before installation. Coat O-rings (25B) with silicon grease and place them in their recesses. Insert seal cases (21) into valve casing (26) before mounting the whole unit. Slide valve casing over plungers. Tighten hexagon socket screws (34) at 22 ft.-lbs. (40 Nm). 8. Using two screwdrivers, gently pry seal cases (21) out of the valve casing (26) or intermediate casing (25). Press grooved rings (23) and support rings (24) out of intermediate casing (25) using a screwdriver. Check O rings (21A/25B). Examine seals (23). Replace worn seals. 6

REPAIR INSTRUCTIONS - CP470 6 8 4 2 1 3 16 9. Check plunger surfaces (16). Damaged surfaces lead to accelerated seal wear. Deposits of all kinds must be removed from the plungers. Important: Plunger surfaces are not to be damaged. If there are lime desposits in the pump, care must be taken that the weep return bore in parts (25) and (26) ensure trouble free weep return. 7 5 10. If the plunger pipe (16B) is worn, remove tension screw (16D) and remove together with plunger pipe. Check and clean plunger (16A) surfaces and mount new plunger pipe. Cover thread of tension screw (16D) with a thin film of Loctite and tighten carefully at 247 in-lbs (28 Nm). Important: Glue must never come between the plunger pipe (16B) and the centring sleeve (16C). The plunger pipe is not to be strained by eccentric tightening of the tension screw or through damage to the front surface as this can lead to breakage. 11. When reassembling, tighten inner hexagon screw (34) at 22 ft-lbs. (40 Nm) in a crossing pattern (as shown on left). Gear and Plunger If oil leaks where the plungers (16) protrude out of the gear, gear seals (19) and plungers must be examined and replaced if necessary. a) Gear Seal: Remove oil plug (5) and drain oil. Remove valve casing (26) together with seal casing (25) as described above. Dismantle plunger pipe (16B). Pry gear seal adaptor (20) out of the crankcase using a screwdriver; take out gear seal (19) and replace it. b) Plungers: Remove oil plug (5) and drain oil; remove crankcase cover (3). Remove valve casing (26), seal casing 25), gear seal adaptors (20) and plunger pipes (16B) as described above. Remove screws on conn-rods (15). Be careful not to mix up the connecting rod halves. Push connecting rod shaft as far as possible into the crosshead guide. Take off screws (10) and pry out bearing covers (7 & 8) with the help of a screwdriver. Take out crankshaft carefully threading it past the conrods (15), making sure not to bend the connecting rods. Remove and dismantle connecting rods and plungers (16). Replace worn parts. Reassemble and tighten tension screws (16D) at 247 in-lbs (28 Nm). When reinstalling, first insert connecting rods together with plungers. Thread in crankshaft. Then push bearing covers (7 & 8) onto the crankshaft ends. Screw on bearing covers with screws (10). Mount connecting rod halves and tighten screws (15) at 22 ft-lbs. Mount crankcase cover (3) together with O ring (4). Replace seal adaptors (20), seal casing (25) and valve casing (26). Replace eight (8) hexagon screws (34) and tighten to 22 ft-lbs (40 Nm). 7

CP470 Pump Dimensions - inches (mm) GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-service car wash applications, the discharge manifolds will never fail, period. If they ever fail, we will replace them free of charge. Our other pump parts, used in portable pressure washers and in car wash applications, NON- are warranted for five years from the date of shipment for all pumps used in SALINE, clean water applications. 2. One (1) year from the date of shipment for all other Giant industrial and consumer pumps. 3. Six (6) months from the date of shipment for all rebuilt pumps. 4. Ninety (90) days from the date of shipment for all Giant accessories. This warranty is limited to repair or replacement of pumps and accessories of which the manufacturer s evaluation shows were defective at the time of shipment by the manufacturer. The following items are NOT covered or will void the warranty: 1. Defects caused by negligence or fault of the buyer or third party. 2. Normal wear and tear to standard wear parts. 3. Use of repair parts other than those manufactured or authorized by Giant. 4. Improper use of the product as a component part. 5. Changes or modifications made by the customer or third party. 6. The operation of pumps and or accessories exceeding the specifications set forth in the Operations Manuals provided by Giant Industries, Inc. Liability under this warranty is on all non-wear parts and limited to the replacement or repair of those products returned freight prepaid to Giant Industries which are deemed to be defective due to workmanship or failure of material. A Returned Goods Authorization (R.G.A.) number and completed warranty evaluation form is required prior to the return to Giant Industries of all products under warranty consideration. Call (419)-531-4600 or fax (419)-531-6836 to obtain an R.G.A. number. Repair or replacement of defective products as provided is the sole and exclusive remedy provided hereunder and the MANUFACTURER SHALL NOT BE LIABLE FOR FURTHER LOSS, DAMAGES, OR EXPENSES, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES DIRECTLY OR INDIRECTLY ARISING FROM THE SALE OR USE OF THIS PRODUCT. THE LIMITED WARRANTY SET FORTH HEREIN IS IN LIEU OF ALL OTHER WARRANTIES OR REPRESENTATION, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WAR- RANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND ALL SUCH WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED BY THE MANUFACTURER. SOLD EXCLUSIVELY THROUGH AQUA BLAST 1025 W. Commerce Drive, Decatur, IN 46733 PHONE (260) 728-4433, FAX (260) 728-4517, www.aquablast.com Copyright 2017 Giant Industries, Inc. 02/12 CP470.indd