ROBICON W120 enclosed drive

Similar documents
SINAMICS Drives SINAMICS G120E. Configured enclosed drive for industry Technical Data Sheet April, usa.siemens.com/drives

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

HVW701 HVAC Drive with By-Pass

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

Sensorless Vector Drives


SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

Delta Products VFD CP2000 Bypass Control Packages.

CTi Automation - Phone: Fax: Web:

VS1PFB 230V, 50/60 Hz, 3-Phase

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

RVS-DN Digital Reduced Voltage Motor Starter

HVAC-R Drive Products

HVAC Products. Introducing the SED2 Variable Frequency Drives

HVAC Drives Lenze AC Tech MCH Series Price Book May US Dollars

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

SINAMICS GM150 IGCT version

ATevo SERIES BATTERY CHARGER

High performance Vector Control. Ratings. System configuration

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

SED2 VFD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass

Variable Frequency Drive NEW! Moving your Control. Forward VFD from Unitronics kW Single Phase kW Three Phase

RVS-DX Digital Reduced Voltage Motor Starter

EVO AT SERIES BATTERY CHARGER

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

Motors Automation Energy Transmission & Distribution Coatings EDP11. Enclosed Drive Panel USA EDP11

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

AT EVO SERIES BATTERY CHARGER

Product brochure. Medium voltage AC drive ACS 2000, 4kV 6.9kV HP

BAC Custom Engineered Controls

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

MaxPak Plus Analog DC V S Drive

AT SERIES EVO BATTERY CHARGER

MCD 200 Series Soft Starters

ABB industrial drives ACS800, single drives ACS800, regenerative AC drives ACS800, ultra low harmonic drives

Raising the bar on end-to-end conveyor solutions. SIMOGEAR High-efficiency Geared Motors.

ACH550 VARIABLE FREQUENCY DRIVES FOR HVAC APPLICATIONS

ABB industrial drives ACS800, single drives ACS800, regenerative AC drives ACS800, ultra low harmonic drives

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

CWM_N NEMA Rated Contactors

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

ABB industrial drives ACS800, single drives, 0.75 to 6000 hp

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

SIRIUS Soft Starters Introduction

JC-VSD FP Series II Drives Product Bulletin 1

PowerFlex 6000 Medium Voltage AC Drives

Softstarters Softstarters

Variable Frequency Drives

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Compact, flexible, highest availability. H-compact PLUS

Industrial Chargers and

Chapter 1: Getting Started User Manual Overview...1 2

VSD Series II Variable Speed Enclosed IntelliPass and IntelliDisconnect Drives

Selection and application guide

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

AuCom - Soft Starters

Product brochure. Medium voltage AC drive ACS2000, kw, kv

Product guide. Enclosed NEMA starters. Answers for industry.

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Large Drive. Variable Speed Control is Just the Beginning. Franklin FastApp Firmware. Variable Speed Control NEMA. Standard Features (Enclosed Drives)

SECTION MOTOR CONTROL

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Matched drive-motor combination package

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

ABB standard drives ACS550, Hp

The Perfect Fit. Introducing the Next Generation of SINAMICS PERFECT HARMONY GH180 Air-Cooled Drive. usa.siemens.

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran

Regenerative DC Common Bus Supply

Open Chassis Star-Delta Starter User Guide

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

AT30 SERIES BATTERY CHARGER

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

SP600 AC Drives MODIFIED STANDARD V*S DRIVES SP600 Drives: 480 VAC (3)

ALTIVAR 58 AC Drives

J1000 D E F I 1000 J1000 J1000 J1000 J1000

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

THYRO-PX SERIES DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS

For Operation in the Control Cabinet 3RW Soft Starters

2017 Advanced Energy Industries, Inc. THYRO-S DIGITAL THYRISTOR SWITCH 8 TO 350 A

Illuminator Series CR NEMA 3R

Selection Guide Motor Control Device Solutions

Packaged Drives and Engineered Systems

WARREN COUNTY, N.Y. M/E REFERENCE

1LG0 Low-voltage Motors

Transcription:

SINAMICS Drives ROBICON W120 enclosed drive 1 HP to 200 HP Introduction This technical data sheet provides a short overview of the most important characteristics of the ROBICON W120 enclosed standard 6-pulse drive from Siemens, developed specifically to meet specifications in the municipal water and waste water market. A result of the powerful combination of SINAMICS, the most advanced drives technology platform, and the ROBICON legacy of more than 20 years of quality and expertise in the water and waste water industry, the W120 makes the best even better. The ROBICON W120 is a stand-alone variable speed enclosed drive for non-regenerative single motor applications with variable or constant torque loads. This compact and quiet drive uses IGBT power semiconductors and an innovative cooling concept. The drive can be operated in either Volts/ Hertz or sensorless vector control modes. Standard features The standard drive enclosure is either a wall mount box or a floor standing cabinet, which can be equipped with a wide variety of pre-engineered and custom options. The ROBICON W120 has the following standard features: NEMA 1 enclosure, with blowers (optional NEMA 12 ventilated with air filters) UL listing per UL508C Short circuit current rating (SCCR) 65 ka at 480 V AC Circuit breaker disconnect with flange mount operator handle, mechanically interlocked with the enclosure door Input line reactor Intelligent operator panel (IOP), door mounted for easy start-up and operation Windows based STARTER software common to all models of the SINAMICS family July 2015

Product Specifications Light Overload High Overload (at 460V, 60 Hz) Base load current for 110% overload (at 460V, 60 Hz) Base load current for 150% overload Rated output current Approx. max. input current 1) Power module frame size ROBICON W120 enclosed drive HP A HP A A A Model No. 1 2.2 1 2.2 2.2 4.3 A 6SL3710-1BJ12-2AR0 1.5 3.1 1.5 3.1 3.1 5.2 A 6SL3710-1BJ13-1AR0 2 4.1 2 4.1 4.1 6.3 A 6SL3710-1BJ14-1AR0 3 5.9 3 5.9 5.9 8.1 B 6SL3710-1BJ16-0AR0 4 7.7 4 7.7 7.7 10 B 6SL3710-1BJ17-7AR0 5 10.2 5 10.2 10.2 12.4 B 6SL3710-1BJ21-0AR0 10 16 7.5 13.2 16 18.6 C 6SL3710-1BJ21-8AR0 15 22 10 19 22 25 C 6SL3710-1BJ22-5AR0 20 27 15 26 27 30 C 6SL3710-1BJ23-2AR0 25 34 20 32 34 38 D 6SL3710-1BJ23-8AR0 30 41 25 38 41 45 D 6SL3710-1BJ24-5AR0 40 54 30 45 54 59 D 6SL3710-1BJ26-0AR0 50 68 40 60 68 73 E 6SL3710-1BJ27-5AR0 60 80 50 75 80 86 E 6SL3710-1BJ29-0AR0 75 100 60 90 100 108 F 6SL3710-1BJ31-1AR0 100 130 75 110 130 138 F 6SL3710-1BJ31-5AR0 125 160 100 145 160 170 F 6SL3710-1BJ31-8AR0 150 186 125 178 186 194 F+ 6SL3710-1BJ32-0AR0 200 240 150 205 240 249 F+ 6SL3710-1BJ32-5AR0 1) The input current is based on the input current of the power module and includes an allowance of 2.0 A ( 60 HP) or 2.5 A (>60 HP) for auxiliary circuits. The standard ROBICON W120 base enclosed drive includes: NEMA 1 enclosure UL508C listing (file no. E319311) Short circuit current rating (SCCR) 65 ka at 480 V AC Power module PM240 (standard 6-pulse) Input line reactor Circuit breaker disconnect with mechanical door interlock Intelligent operator panel (IOP), door mounted and wired Integral braking chopper Cable entry top or bottom, line and motor side Controller CU230P-2 HVAC with: RS485 serial communications port USS / Modbus RTU / BACnet MS/TP 6 digital inputs, 24V 15 ma, optically isolated (group) 3 relay outputs, 2x form C 250 VAC 2 A or 30VDC 5 A, 1x NO 30 VDC 0.5 A 4 analog inputs, 2x differential -10V to +10V or 0/4 to 20mA, 1x 0/4 to 20mA or temperature sensor, 1x temperature sensor input for Ni1000/Pt1000 sensor Input for temperature sensor KTY84, PTC thermistor or thermostat 2 analog outputs, 0 to +10V or 0/4mA to 20mA, 1x 0/4mA to 20mA, non-isolated NOTE: Some of the control unit inputs and/or outputs may be used for options. 2

Standard Options Option Code Description Enclosure Options 1) M12 NEMA 12 filters L50 Cabinet light and outlet L55 Cabinet space heaters (120VAC) L56 Motor space heater supply Y09 Special enclosure paint color [specify color] Power Circuit and Protection Options L08 reactor L10 2) dv/dt filter L13 Input isolation contactor L15 2) sinusoidal filter L24 5% input reactor L27 Input fuses L28 Two contactor manual bypass (output/bypass contactors with o/l) L29 2) Reduced voltage soft start (RVSS) manual bypass (75-200 HP only) L32 isolation contactor L63 Braking resistor L96 Input surge protective device L98 Motor thermal overload relay (already included in L28) L99 Motor protection relay (Multilin 369) (75-200 HP only) P10 Input voltage monitor (Siemens type 3UG4) Option Code Description Control Options E86 Isolation amplifier for one analog input E87 Isolation amplifier for two analog outputs K20 Pilot lights (qty. 3), door mounted Ready, Run, Fault K21 Additional local controls (L-R & H-O-A, speed pot, Start/Stop p/b) K22 Elapsed time (hour) meter, door mounted, non-resettable L87 Ground fault monitor for ungrounded supplies (75-200 HP only) L97 RTD monitor for 8x Pt100 temperature sensors N55 ALL STOP mushroom pushbutton, latching, coast to stop Communication Bus Options G81 PROFIBUS DP communication port G82 EtherNet/IP or PROFINET communication port Other Options H20 Seismic certification per IBC 2012 (provide specification) 1) For wall mount drives, enclosure options listed above are available only for the VFD enclosure itself. They are not available for the separate options enclosure. 2) These options require a larger or additional enclosure as follows: For wall mount drives, these options are provided in separate, stand-alone options enclosures. The separate options enclosures are always provided as NEMA 1 only (also if the drive enclosure is ordered with option M12 NEMA 12 filters), color ANSI 61 grey. For floor standing drives, these options are provided in a larger enclosure (add-on options cabinet). Option M12 adds NEMA 12 filters to both the drives and attached add-on enclosures, and with option Y09 the complete enclosure will have the specified special paint color. Options in the add-on or separate cabinet may be listed to UL508A. Note: Please consult factory for additional/custom options. 3

Design Data 1 to 60 HP Wall Mount Drive Enclosure Spacing to adjacent units or wall 6 (1 20 HP) or 12 (25-60 HP) AIR OUT ROBICON ROBICON H N AIR IN D N SIDE VIEW W N FRONT VIEW Notes: To assure proper air circulation, please allow minimum 6 (1 20 HP) respectively 12 (25-60 HP) space between adjacent wall mount drive enclosures or to a side wall. Dimensions are nominal for enclosure, tolerance 0.5 (12 mm), excluding protruding components. Please refer to drawings for exact details. ROBICON W120 Enclosed drive (Light Overload) (at 460V, 60 Hz) Noise level LpA (1m) at 60 Hz Cooling air flow demand Heat loss approx. Drive enclosure Nominal Size W N x D N x H N Model No. HP db (A) cfm kw lb. kg inch mm Wall mount enclosure 6SL3710-1BJ12-2AR0 1 64 77 0.14 230 104 20 x 16 x 48 508 x 440 x 1219 6SL3710-1BJ13-1AR0 1.5 64 77 0.15 230 104 20 x 16 x 48 508 x 440 x 1219 6SL3710-1BJ14-1AR0 2 64 77 0.15 230 104 20 x 16 x 48 508 x 440 x 1219 6SL3710-1BJ16-0AR0 3 64 115 0.18 230 104 20 x 16 x 48 508 x 440 x 1219 6SL3710-1BJ17-7AR0 4 64 115 0.19 230 104 20 x 16 x 48 508 x 440 x 1219 6SL3710-1BJ21-0AR0 5 64 115 0.24 230 104 20 x 16 x 48 508 x 440 x 1219 6SL3710-1BJ21-8AR0 10 64 182 0.38 230 104 20 x 16 x 48 508 x 440 x 1219 6SL3710-1BJ22-5AR0 15 64 182 0.44 230 104 20 x 16 x 48 508 x 440 x 1219 6SL3710-1BJ23-2AR0 20 64 182 0.47 230 104 20 x 16 x 48 508 x 440 x 1219 6SL3710-1BJ23-8AR0 25 67 318 0.58 330 150 26 x 20 x 60 660 x 508 x 1524 6SL3710-1BJ24-5AR0 30 67 318 0.68 330 150 26 x 20 x 60 660 x 508 x 1524 6SL3710-1BJ26-0AR0 40 67 318 0.85 330 150 26 x 20 x 60 660 x 508 x 1524 6SL3710-1BJ27-5AR0 50 67 360 1.27 330 150 26 x 20 x 60 660 x 508 x 1524 6SL3710-1BJ29-0AR0 60 67 360 1.49 330 150 26 x 20 x 60 660 x 508 x 1524 4

Design Data s for wall mount drives Separate Options Enclosure (Floor Mount) H O D O SIDE VIEW W O FRONT VIEW Notes: Dimensions are nominal for enclosure, tolerance 0.5 (12 mm), excluding protruding components. Please refer to drawings for exact details. These separate option enclosures are available as NEMA 1 only, color ANSI 61 grey. ROBICON W120 Add-on options enclosure Enclosed drive Model No. (Light Overload) (at 460V, 60 Hz) HP L10 output dv/dt filter W o x D o x H o L15 output sinusoidal filter W o x D o x H o Floor standing enclosure 6SL3710-1BJ12-2AR0 1 13 x 13 x 13 / 330 x 330 x 330 18 / 8 13 x 13 x 14 / 330 x 330 x 356 20 / 9 6SL3710-1BJ13-1AR0 1.5 13 x 13 x 13 / 330 x 330 x 330 18 / 8 13 x 13 x 14 / 330 x 330 x 356 21 / 10 6SL3710-1BJ14-1AR0 2 13 x 13 x 13 / 330 x 330 x 330 18 / 8 13 x 13 x 14 / 330 x 330 x 356 25 / 11 6SL3710-1BJ16-0AR0 3 13 x 13 x 13 / 330 x 330 x 330 18 / 8 13 x 13 x 14 / 330 x 330 x 356 25 / 11 6SL3710-1BJ17-7AR0 4 13 x 13 x 13 / 330 x 330 x 330 18 / 8 13 x 13 x 14 / 330 x 330 x 356 27 / 12 6SL3710-1BJ21-0AR0 5 13 x 13 x 13 / 330 x 330 x 330 18 / 8 13 x 13 x 14 / 330 x 330 x 356 27 / 12 6SL3710-1BJ21-8AR0 10 13 x 13 x 13 / 330 x 330 x 330 19 / 9 13 x 13 x 14 / 330 x 330 x 356 34 / 15 6SL3710-1BJ22-5AR0 15 13 x 13 x 13 / 330 x 330 x 330 22 / 10 17 x 17 x 24 / 432 x 432 x 610 79 / 36 6SL3710-1BJ23-2AR0 20 13 x 13 x 13 / 330 x 330 x 330 22 / 10 17 x 17 x 24 / 432 x 432 x 610 82 / 37 6SL3710-1BJ23-8AR0 25 13 x 13 x 13 / 330 x 330 x 330 24 / 11 17 x 17 x 24 / 432 x 432 x 610 86 / 39 6SL3710-1BJ24-5AR0 30 13 x 13 x 13 / 330 x 330 x 330 24 / 11 17 x 17 x 24 / 432 x 432 x 610 95 / 43 6SL3710-1BJ26-0AR0 40 13 x 13 x 13 / 330 x 330 x 330 32 / 15 17 x 17 x 24 / 432 x 432 x 610 101 / 46 6SL3710-1BJ27-5AR0 50 13 x 13 x 13 / 330 x 330 x 330 40 / 18 18 x 21 x 34 / 457 x 533 x 864 136 / 62 6SL3710-1BJ29-0AR0 60 13 x 13 x 13 / 330 x 330 x 330 40 / 18 18 x 21 x 34 / 457 x 533 x 864 147 / 67 5

ROBICON ROBICON Design Data 75 to 200 HP Floor Standing Enclosure A I R O U T ROBICON A D D O N O P T I O N S E N C L O S U R E 9 4 / 2 3 7 7 m m A I R I N A I R I N 2 4 / 6 1 0 m m S I D E V I E W SIDE VIEW W O 3 0 / 7 6 2 m m F R O N T V I E W FRONT VIEW Notes: Dimensions are nominal for enclosure, tolerance 0.5 (12 mm), excluding protruding components. Please refer to drawings for exact details. ROBICON W120 Enclosed drive (Light Overload) (at 460V, 60 Hz) Noise level L pa (1m) at 60 Hz Cooling air flow demand Heat loss approx. Drive enclosure Nominal size W N x D N x H N Model No. HP db(a) cfm kw lb kg inch mm Floor standing enclosure 6SL3710-1BJ31-1AR0 75 69 504 1.90 720 327 30 x 24 x 94 762 x 610 x 2377 6SL3710-1BJ31-5AR0 100 69 504 2.40 720 327 30 x 24 x 94 762 x 610 x 2377 6SL3710-1BJ31-8AR0 125 69 504 2.80 720 327 30 x 24 x 94 762 x 610 x 2377 6SL3710-1BJ32-0AR0 150 69 504 2.83 760 345 30 x 24 x 94 762 x 610 x 2377 6SL3710-1BJ32-5AR0 200 69 504 2.93 760 345 30 x 24 x 94 762 x 610 x 2377 Add-on options enclosure Model No. (Light Overload) (at 460V, 60 Hz) HP L10 output dv/dt filter Width W o L15 output sinusoidal filter Width W o L29 RVSS bypass Width W o Floor standing enclosure 6SL3710-1BJ31-1AR0 75 20 / 508 450 / 205 20 / 508 440 / 200 20 / 508 463 / 210 6SL3710-1BJ31-5AR0 100 20 / 508 450 / 205 20 / 508 440 / 200 20 / 508 463 / 210 6SL3710-1BJ31-8AR0 125 20 / 508 450 / 205 20 / 508 440 / 200 20 / 508 463 / 210 6SL3710-1BJ32-0AR0 150 20 / 508 450 / 205 24 / 610 660 / 300 20 / 508 463 / 210 6SL3710-1BJ32-5AR0 200 20 / 508 450 / 205 24 / 610 660 / 300 20 / 508 463 / 210 6

Technical Data Electrical data Supply voltages and output ranges 460 V to 480 V 3 ph AC, ±10%, 1 to 200 HP Supply systems Grounded or ungrounded supplies Line frequency 47 Hz to 63 Hz frequency 0 Hz to 266 Hz (550 Hz with derating) Power factor fundamental approx. 0.95 Drive efficiency 93 to 97% Short circuit current rating SCCR 65kA Control method V/Hz control, V/Hz with flux current control (FCC), sensorless vector control (SVC). Fixed speeds 16 fixed frequencies Skipped frequency ranges 4, programmable Braking operation Integral brake chopper for dynamic braking Mechanical data Type of enclosure and color NEMA 1, optionally NEMA12 (ventilated), ANSI 61 gray Type of cooling Forced air ventilation Noise level LpA (1 m) 64 to 69 db(a) at 60 Hz line frequency Environmental protection Nickel plated busbars, varnish coated electronic boards Compliance with standards UL listing Listed to UL508C, file no. E319311 Ambient conditions Operation Storage Transport Ambient temperature 32 F to 104 F (0 C to +40 C) Up to +122 F/+50 C with derating -13 F (-25 C) to 131 F (+55 C) -13 F (-25 C) to 158 F (+70 C) Down to -40 F (-40 C) for 24 hours Relative humidity (non-condensing) 5% to 95% 5% to 95% 5% to 95% at 40 C Installation altitude Up to 3,300 ft (1000 m) above sea level without reduction in performance, > 3,300 ft see derating data Engineering Information Overload ratings The ROBICON W120 drive may be operated with both variable torque and constant torque loads at either light or high overload duties. The criterion for overload is that the drive is operated with its base load current before and after the overload occurs. Light overload duty is based on 110% base load current for 60 sec or 150% for 3 sec, repeated every 300 sec. Light overload High overload duty is based on 150% base load current for 60 sec or 200% (<125 HP) or 175% (125 & 150 HP) for 3 sec, repeated every 300 sec. Motor and drive sizing Service Factor must be considered for motors operating at Service Factors beyond 1.0. Please consult factory for assistance sizing the drive. For motors with ratings larger than the drive, please consult factory as nuisance tripping may occur if drive is not properly sized. In sensorless vector control, the rated motor current (FLA) must be at least 1 4 of the rated drive output current. With lower motor currents, operation is possible in Volts/Hz control mode only. Intelligent operator panel (IOP) The SINAMICS IOP makes it easy to operate, commission and diagnose faults on the drive. Up to two process values can be displayed on the screen either graphically or numerically. Process values can be displayed in the appropriate technological units. The user language can be selected. Due to the large plain text display, menu prompting and application wizards, commissioning of drives is very quick. Parameters are displayed in plain text, explanatory help texts are provided and there is a parameter filter function. The user is interactively navigated through commissioning of common applications such as pumps, fans, compressors and conveyors using application wizards. The IOP has a dedicated key to toggle between local (from IOP) and remote control. Fault diagnosis is in a user-friendly fashion using plain text display of faults and alarms. Explanatory help texts are provided by pressing the INFO key. 7

Siemens Industry, Inc. 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-241-4453 info.us@siemens.com usa.siemens.com/drives Subject to change without prior notice. Order No.. DRBR-00104-0715 Printed in USA 2015 Siemens Industry, Inc. The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.