GuardMagic DLLS-DLLE programming tool manual v

Similar documents
INDEX 1 Introduction 2- Software installation 3 Open the program 4 General - F2 5 Configuration - F3 6 - Calibration - F5 7 Model - F6 8 - Map - F7

EPAS Desktop Pro Software User Manual

PowerJet Sequential Injection INDEX. 1 Introduction 1.1 Features of the Software. 2- Software installation

OPERATION AND MAINTENANCE

EZECU - EzFi Starter ECU Standalone 3D Programmable Fuel Injection Computer for BOSCH Compliant EFI Systems

Issue 2.0 December EPAS Midi User Manual EPAS35

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

Real Time Vehicle Monitoring

EZECU - Sport Fi ECU Piggyback 3D Programmable Fuel Injection Computer for BOSCH Compliant EFI Systems

Network Installation. July 2008 CONTENTS

CVR Release Notes Page 1 of 7

Electronic Park Brake, Service & Reset Tool. User Guide

TachoDrive key + TachoDrive Express software

JUMO DSM software. PC software for management, configuration, and maintenance of digital sensors. Operating Manual T90Z001K000

Begin to Use The New ESC: Before use the new ESC please carefully check every connections are correct or not. Yellow motor wire B Blue motor wire A

QUICK START GUIDE 199R10546

Instruction of connection and programming of the VECTOR controller

BRAKE TESTER DECELEROMETER

BERMAD Waterworks. Insertion Flow Meter Device (IFM)

BMS16. Thanks for your purchasing the BMS16 for your vehicle.

T100 Vector Impedance Analyzer. timestechnology.com.hk. User Manual Ver. 1.1

When you finish the running, power off the receiver BEFORE turning off the transmitter.

BMS24. Thanks for your purchasing the BMS24 for your vehicle.

Technical Specifications

PDC PROPELLER DE-ICE CONTROLLER

EcuTek ProECU. Software Overview. v1.2

Scout II Operation Instructions

SPARKER DC-CDI-P2 HARDWARE

Hi-Z USB Wireless. Introduction/Welcome

NO PART OF THIS DOCUMENT MAY BE REPRODUCED WITHOUT PRIOR AGREEMENT AND WRITTEN PERMISSION OF FORD PERFORMANCE PARTS.

Instruction of connection and programming of the OSCAR-N controller

Installation And Programming Manual of OPTIMA Eco Tec and OPTIMA Pro Tec OBD/CAN

CurveMaker DFS v2.0 Dyna FS Ignition Programming Software

CAN-Translator. User s guide

тел.: +375(1771) e mail: Fuel level sensors eurosens Dominator

RS232. CAN. Integration with Tachograph Continental VDO DTCO

TPMS Adapter Instruction Manual. (Tire Pressure Monitoring System)

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW

Mitsubishi. VFD Manuals

Operating Instructions

Advanced User Manual

Multi-Function Ground Resistance Tester Model 6472

PSC1-003 Programmable Signal Calibrator

Instruction Manual Installation and Operation Guidelines for DWL5000XY and DWL5500XY Tilt Sensor Modules (Version 2.2)

Getting Started HONDA

CORNERING LIGHTING MODULE CLM02-CAN INSTALLATION MANUAL

BLU SERIES Battery Load Units

DC Controlled screwdrivers

ALM-Inline. Accurate Lambda Meter V1.1.2 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED.

MXL Pista / MXL Strada KIT FOR SUZUKI GSX R

Online Capacity Tester MK70 User and PC-Software Manual

DOLI's STANDARD COMPRESSION FLEXOMETER (GOODRICH FLEXOMETER)

VFD - Mitsubishi. VFD Manuals. Mitsubishi D700 VFD Installation. Mitsubishi FR-D700 VFD User Manual. Mitsubishi D700 Parallel Braking Resistors

BLU SERIES Battery Load Units

CONTROL LAMBDA INSTALLATION MANUAL

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28

ALM LSU ADV Manual. Accurate Lambda Meter With built-in LED display COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED.

Product Warranty Statement

:34 1/15 Hub-4 / grid parallel - manual

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

MICROPROCESSOR BASED CONTROLLER

Product Guide: Series III Pump Control Board Set (RoHS)

Controller over electromechanical fuel dispensers for petrol stations

SNMP dedicated to ORVALDI Solar Infini

DCDC-USB. 6-34V 10A, Intelligent DC-DC converter with USB interface. Quick Installation Guide Version 1.0c P/N DCDC-USB

FLEC AIR PUMP Operators Manual JULY QUI-1030 VERSION 1.2

NTK2000 UEGO OPERATORS MANUAL

X117E. X117E Contact-Less Valve Position Transmitter INSTALLATION / OPERATION / MAINTENANCE MODEL. X117E Contact-Less Valve Position Transmitter

Installing a Programmed Fronius SCERT in a Managed AC Coupled system

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

BMS16T BMS24T. Thanks for your purchasing the BMS16T or BMS24T for your vehicle.

Compression/Tension Testing Machines


JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

Callisto 100. Cold Filter Plugging Point Tester

SUZUKI DIAGNOSIS SYSTEM OPERATION MANUAL

DKG-109 AUTOMATIC MAINS FAILURE UNIT

DKG-109J AUTOMATIC MAINS FAILURE UNIT

BLU SERIES Battery Load Units

LAMBDA SENSOR CONTROLLER

GENERAL MOTORS SERVICE PARTS OPERATION 6200 Grand Pointe Drive, Grand Blanc, MI 48439

DC Controlled screwdrivers

Hub-4 / grid parallel - manual

Support. EMROL Your power partner

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Package Contents: Transferring Data to a PC

flowtronic Sensor Series S8005 flowtronic Sensor Series S8005 Product Information Version GREGORY Technology GmbH

Manual Kinematic Viscosity Bath Tamson TV12

Features: ECUtalk enables the user to:

VFD. Variable Frequency Drive

TachoReader Combo Plus

USER S MANUAL TACHOTERMINAL PRO1 TACHOTERMINAL PRO2. Firmware and higher

DATUM ELECTRONICS RS425 NON-CONTACT TORQUE TRANSDUCER PRODUCT OVERVIEW

HK Equipment CZD Brake tester Max. weight Size Roller size Measure range Error Rated use condition: CCH Sideslip tester 10,000kg (15,000kg) 3990 x 840

MXL Pista / MXL Strada PLUG & PLAY KIT FOR SUZUKI GSX R

1.0 SOFTWARE GRIPONE PRO 2

PLATINUM SPORT GM (HT051100) QUICK START GUIDE. Version

Innovative Vehicle Electronics Systems DC Motor Controller Model DC750 User Manual. Patent pending 2011 Synkromotive, LLC

CurveMaker HD v1.0 2Ki Programmable Ignition programming software

MXL Strada / Pista Plug and Play kit for Kawasaki ZX-10 R

Transcription:

DLLS-DLLE programming tool manual v1.10 01-01-2013 DLLS-DLLE Programming Tool (GM2.034) User Manual 2013

Table of contents: 1. INTRODUCTION... 3 2. PACKAGES... 3 2.1. STANDARD PACKAGE... 3 2.2. OPTIONAL (order in additional)... 3 2.3. PACKAGE... 3 3. OVERWIEV OF MAIN COMPONENTS... 4 4. SYSTEM REQUIREMENTS... 5 5. GUARDMAGIC SCA OVERWIEV... 5 5.1. ABOUT... 5 5.2. GUARDMAGIC SCA FRONT PANEL... 5 5.3. GUARDMAGIC SCA REAR PANEL... 5 6. GUARDMAGIC SCA CONNECTION TO PC AND POWER SOURCE... 6 6.1. GUARDMAGIC SCA CONNECTION TO PC AND POWER SOURCE... 6 6.2. FTDI DRIVER ISTALLATION... 6 7. FUEL LEVEL SENSOR CONNECTION... 7 7.1. GUARDMAGIC DLLS1a, DLLS1b, DLLS2a, DLLS2b CONNECTION... 7 7.2. GUARDMAGIC DLLE1ct (GUARDMAGIC JBB01) CONNECTION... 7 7.3. GUARDMAGIC DLLS1ct, DLLS2ct DIRECT CONNECTION... 8 7.4. GUARDMAGIC DLLS1ct, DLLS2ct CONNECTION BY ADDITIONAL CABLE... 8 8. ORDER OF PROCEDURE... 9 9. DLLS-DLLE PROGRAMMING TOOL SOFTWARE OVERVIEW... 10 9.1. SOFTWARE OVERVIEW... 10 9.2. FILE MENU... 11 9.3. SENSOR DATA... 11 9.4. TAB "SETTINGS"... 12 9.5. TAB "CALIBRATION"... 13 9.6. CONNECTION SETTING AND CONNECT BUTTON... 13 9.7. STATUS BAR... 13 10. PROGRAMMING PROCEDURE... 14 10.1. PIMERY FUEL SENSOR SETTING... 14 10.2. OPERATION MODE AND ADDRESS SETTING... 15 11. FUEL TANK CALIBRATION... 16 11.1. PRINCIPAL PROVISIONS... 16 11.2. ACTION ORDER OF CALLIBRATION PROCEDURE... 17 12. ABOUT FUEL LEVE SENSORS SETTING... 18 2

1. INTRODUCTION " DLLS-DLLE programming tool is the special technological complete set intended for customer programming and change the setting of DLLS and DLLE fuel level sensors by Personal Computer. In additional " DLLS-DLLE programming tool utility allows to carry out fuel tank calibration procedure. Fuel tank calibration procedure is carried by Personal Computer (Notebook). 2. PACKAGES 2.1. STANDARD PACKAGE SCA (DLLS/DLLE sensor adapter: GM3.033) 1 pc. AC/DC (220V/12V) power adapter with cable - 1 pc. Cable USB A USB-B - 1 pc Cable GM4.019-1 pc Cable GM4.019-01 - 1 pc DLLS-DLLE programming tool User Guide -1 book CD disk with manuals and software -1 CD 2.2. OPTIONAL (order in additional) Three pole WAGO connectors. (for connection to DLLS1ct or DLLS2ct fuel level sensor) - 4 pcs 2.3. PACKAGE The complete set is packed into a box of corrugated cardboard 3

3. OVERWIEV OF MAIN COMPONENTS SCA (GM3.033) DLLS/DLLE sensor adapter: AC/DC (220V/12V) power adapter with cable Cable USB A USB-B Cable GM4.019 (for connection to: JBB01 barrier and to DLLS1ct or DLLS2ct fuel level sensors) Коннектор RJ45 Cable GM4.019-01 (for connection to: DLLS1a, DLLS1b fuel level sensors) Connector RJ45 Connector SuperSeal 4 poles CD disk with manuals and software CD disk contents: DLLS/DLLE programming and fuel tank calibration software; FTDI utility DLLS-DLLE programming tool User Manual 4

4. SYSTEM REQUIREMENTS System requirements to the PC: - MS Windows XP, MS Windows Vista, MS Windows 7; - Intel Pentium IV 600 or above (or AMD analogue); - Main memory 256MB or above; - 10 free space on a hard disk; - Mouse and keyboard; - USB port; - Video adapter and color monitor with the resolution not less than 800 x 600; - CD or DVD ROM. 5. GUARDMAGIC SCA OVERWIEV 5.1. ABOUT SCA is a special interface adapter for converting USB interface to industrial EIA- 485 (RS-485) interface. 5.2. GUARDMAGIC SCA FRONT PANEL In SCA front panel located: EIA-485 connector (RJ45 type) for connecting to SCA adapter EIA-485 cable; Power LED (Green). Indicate that the SCA module is powering; USB LED (Red). Indicate that USB cable connected to PC 5.3. GUARDMAGIC SCA REAR PANEL In SCA rear panel located: USB connector (USB-B) for connection SCA adapter to PC; Power connector (12 V, DC) for connection SCA adapter to power source (power adapter 12 V, DC). 5

6. GUARDMAGIC SCA CONNECTION TO PC AND POWER SOURCE 6.1. GUARDMAGIC SCA CONNECTION TO PC AND POWER SOURCE SCA connection is shown bellow: AC 110... 230V DC 10V... 12V USB cable (USB-A to USB-B) 6.2. FTDI DRIVER ISTALLATION Before operation will be need to install FTDI driver in your PC. a) automatically installation Connect your PC to internet and connect your PC to SCA adapter. AC adapter connect to power source. Windows automatically find a new device in your PC and automatically install FTI driver in your PC. b) manual installation Copy FTDI driver from CD disk and install it in your PC. 6

7. FUEL LEVEL SENSOR CONNECTION 7.1. GUARDMAGIC DLLS1a, DLLS1b, DLLS2a, DLLS2b CONNECTION USB AC SCA EIA-485 connector Cable GM4.019-01 : DLLS1a; DLLS1b, DLLS2a; DLLS2b. for reference: Circuit GND Power + A (485-) B (485+) PIN 1 2 3 4 7.2. GUARDMAGIC DLLE1ct (GUARDMAGIC JBB01) CONNECTION USB AC SCA EIA-485 connector Cable GM4.019 JBB01 JBB01 In/Out1 In/Out2 Ex1 Ex2 Cable GM4.019 Wire mark Green White Yellow Red Circuit Power + GND A (485-) B (485+) + GND A B DLLE1ct; DLLE2ct Note: DLLE JBB01 connection is shown in: JBB01 installation manual and DLLE installation manual 7

7.3. GUARDMAGIC DLLS1ct, DLLS2ct DIRECT CONNECTION USB AC SCA EIA-485 connector Cable GM4.019 WAGO connectors DLLS1ct; DLLS2ct cable GM4.019 Wire mark White Green Yellow Red Circuit GND Power + A (485-) B (485+) cable from fuel level sensor Wire mark Yellow-green 1 2 3 7.4. GUARDMAGIC DLLS1ct, DLLS2ct CONNECTION BY ADDITIONAL CABLE USB SCA cable GM4.019-01 cable GM4.015 AC EIA-485 connector DLLS1ct; DLLS2ct Circuit GND Power + A (485-) B (485+) Wire mark Yellow-green 1 2 3 WAGO connectors 8

8. ORDER OF PROCEDURE Copy program GM DLLS-DLLE PT (FSProgrTool.exe) from CD disk to your PC hard disk; Connect SCA adapter to your PC (paragraph 6.1); Connect AC/DC adapter to power source and check LED status in SCA adapter. LED indicators in SCA adapter have to light; Install FTDI driver in your PC (paragraph 6.2); Connect fuel level sensor to to SCA adapter (paragraph 7); Run program GM DLLS-DLLE PT (description: paragraph 9); Start fuel level sensor setting (paragraph 10). Notes: Status of LED indicators 9

9. DLLS-DLLE PROGRAMMING TOOL SOFTWARE OVERVIEW Start the program GM DLLS-DLLE PT (FSProgrTool.exe). After start the program on the screen will open the basic form, shown on figure. 9.1. SOFTWARE OVERVIEW The GM DLLS-DLLE PT form consist of: 1. text menu; 2. "sensor data" part; 3. "settings" tab; 4. "calibration" tab; 5. connection settings and "Connect" button; 6. status bar. 10

9.2. FILE MENU File menu consists of the menu line with following items: File Menu File Language About Function Description Choice of the working language Information about the program 9.3. SENSOR DATA Show sensor data: Item Firmware Version Factory Number Freq Code Temp Fuel Meter Function Description Fuel sensor firmware version Fuel sensor factory number Current frequency Current fuel level code Current temperature Shows current fuel level in the fuel tank Frequency value and code value will change on fuel level change. 11

9.4. TAB "SETTINGS" The tab "Settings" is intended for the programming of fuel level sensor parameters. Item Frequency Max Frequency Min Function Description Frequency of minimal fuel level in the tank Frequency of maximal fuel level in the tank Communication Speed Communication speed with which the fuel level sensor (19 200, 38 400, 57 600) Operation Mode Network Address Divider Periodicity Filter Activation Filter Constant Malfunction Tc Setting Fuel level sensor operational mode (Slave - network mode, Master - stand alone mode) Fuel level sensor network address (available addresses - 1..23) Select the value of sensor length which sensor you are using Periodicity of data sending in Stand Alone mode (available values - 0..255) Activation of internal fuel filter Constant of data filter Malfunction bit sending activation Some main modules can not support this functionality Calibration sensor internal thermometer. Set one temperature point. 12

9.5. TAB "CALIBRATION" Item Calibration Table Clear Table Liters Add Value Function Description Clear Calibration Table Fuel level value in liters Add current fuel level code and corresponding to it fuel level value 9.6. CONNECTION SETTING AND CONNECT BUTTON Item Connection Speed RS232 port number Connect / Disconnect Function Description Fuel level sensor working speed (available values - 19200, 38400, 57600) Number of RS232 port to which fuel level sensor is connected Connect or disconnect to the fuel level sensor. 9.7. STATUS BAR Status bar is intended to show connection status. After connecting to the fuel sensor information about COM port number and connection speed is shown in the status bar. 13

10. PROGRAMMING PROCEDURE The fuel level sensor programming procedure is consistently completing the required fields on the persistence and saving entered data. For the data saving it is necessary to push button Update. 10.1. PIMERY FUEL SENSOR SETTING Attention!!! Sensor adjustment should be provided with the same fuel type equal to the vehicle s or machine operation fuel. The DLLS, DLLE sensor scale should be adjusted after tube cutting. «DLLS-DLLE Programming Tool» software makes it. Connect the sensor to PC by special 485 adapter (for example, SCA adapter). Start DLLS-DLLE Programming Tool software. After starting the main window will be shown. 14

Primary fuel sensor setting steps 1. Select necessary "Communication Speed", "RS 232 Port" and press the button "Connect" 2. Put the sensor tube completely into the fuel, pull out Sensor from the fuel, wait for about 2 minutes, and then press Fix Empty button. 3. Put the sensor again completely into the fuel, wait for 2 minutes, and press Fix Full button. 10.2. OPERATION MODE AND ADDRESS SETTING Working mode of Fuel Sensor and Sensor Address setting are carried out also by DLLS- DLLE Programming Tool software. When program is running select necessary "Operation Mode" and "Network Address" and press the button Update. 15

11. FUEL TANK CALIBRATION For fuel tank calibration it is necessary to select "Calibration" tab. See screenshot below. Fuel Tank calibration procedure showing below is only for independently calibration without units VB, FSM, MTF3. Fuel Tank Calibration procedure with units VB, FSM, MTF3 in detailed describe in this product installation manuals 11.1. PRINCIPAL PROVISIONS Fuel tank calibration is consecutive fixing values of a level of fuel, which is filled in vehicle tank or tank trailer (regular or cargo), with the subsequent entering these data in the working program. At carrying out of calibration operation it is convenient to take advantage of the form offered a calibration leaf p.7.4 16

As a measure of filled fuel is used the indicator of a filling station. Filling stations, as a rule, provide accuracy not worse 0,3 %. Code of filled fuel will be shown in calibration software. At calibration procedure fuel is filled in with portions approximately on 1/10-1/20 volumes of a fuel tank. As a rule, carrying out of calibration need to be spent on 5 to 15 control points. Calibration procedure is carried out independently for each fuel tank and fuel level sensor. 11.2. ACTION ORDER OF CALLIBRATION PROCEDURE Carrying out the operation of the calibration procedure is carried out in following order: 1. In a fuel tank of vehicle leave the minimal possible fuel level. This fuel level will be considered as MINIMAL level (like 1 liter); no more than 1%... 2 % of a tank volume; 2. Fix minimal value of the fuel by pressing Add Value button in program ("minimal fuel level" will be fix); 3. Insert a pistol of a fuel hose into a tank; 4. Add some control fuel to the fuel tank; 5. Wait till the value of the fuel level indicator in program will stop changes (field code). About 40 60 sec; 6. Enter the fuel level value in liters (field Liters ). Press Add Value button; 7. Execute the indications of the previous paragraph till filling the fuel tank full with fuel. 8. Write down the table fuel code and fuel volume in the paper table. In the future the values obtained for the calibration data table must be entered in the work program. 17

12. ABOUT FUEL LEVE SENSORS SETTING For operation with main modules ( VB, VF, mtf3, FSL, FSM modules) fuel level sensor have to be in SLAVE MODE ; Fuel level sensor communication speed have to be 19 200 kbit/sec ; In system based on products, sensors network address have to be: Modules Available sensor network address VB3, VB6, VF2 001 003 VB4, VB5, VB6, VB7, VB8 001 003 Regular tanks VB4, VB6 004 007 Service tanks VB8 004 007 Cargo tanks 008 014 FSM2/1 ; FSL 008 010 FSM3 008 010 For standard application filter activation have to be ON For standard application filter constant have to be 5 10 (for vehicle can be start with code: 10). Variation of filter constant allow to make Fine Tune of system. By default Malfunction has to be Off. Main notes: About divider code. Divider code depends of sensor length. Divider code have by default of factory sensor setting. 18