USER MANUAL. Maxwell Technologies BOOSTCAP 56V UPS Energy Storage Modules. Models: BMOD0130 P056 B02 BMOD0130 P056 B03. Document Number

Similar documents
XLM 62V Energy Storage Module

XLR Energy Storage Module

USER MANUAL. Maxwell Technologies Ultracapacitor Energy Storage Modules. Models: 16 V Series: 48 V Series: BMOD0110 P016 B01 BMOD0165 P048 B06

USER MANUAL. Maxwell Technologies. Ultracapacitor Energy Storage Modules Powered by DuraBlue

USER MANUAL. Maxwell Technologies. Ultracapacitor Energy Storage Modules Powered by DuraBlue Technology

APPLICATION NOTE

Maxwell s Highest Power and Energy Cell

USER MANUAL Notes on Using Ultracapacitor Cells

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Advanced Small Cell with XP Technology

High Frequency SineWave Guardian TM

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

ADI-125/750 ADI-125/1500 ADI-125/2500

4707 DEY ROAD LIVERPOOL, NY PHONE: (315) FAX: (315) M.S. KENNEDY CORPORATION MSK Web Site:

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Features. Description. Table of Contents

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

Model Fixed Rack-Mount Kit

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

PowerOhm Installation Manual for BM R Series Braking Modules

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Copyright 2016 Surya Powerfarad Energies Limited. P a g e 1

MIL-24/2600Q MIL-24/3200DQ

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

OWNERS MANUAL JANUARY 2007 ISO

DC to AC Power Inverters

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

DC to AC Power Inverters

APPLICATIONS: AVAILABLE OPTIONS

OWNERS MANUAL JANUARY 2007 ISO

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

PowerOhm Installation Manual for LG ATV Series Braking Modules

EPS/ELA-Series User Manual EPS/ELA 250W

Airpax Dimensions, Inc.

Maxwell Technologies Overview Corporate & Product

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

INSTALLATION & OPERATING MANUAL RW SERIES WALL-MOUNT RECTIFIERS

A1P OPERATING MANUAL

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

(typ.) (Range) ±18 330# 89 MPW MPW

PowerOhm Installation Manual for BM R Series Braking Modules

Inverter User Manual

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

BroadBand PowerShield. 20 AHr Battery. User Manual

Installing the Switch Chassis

Duracell Battery Glossary

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

GLOSSARY: TECHNICAL BATTERY TERMS

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

Owner s Guide. DC TO AC Power Inverter

Features IN THIS CHAPTER

WARRANTY INFORMATION...

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

QHW050F1, QHW075F1, and QHW100F1 Power Modules: dc-dc Converters; 36 to 75 Vdc Input, 3.3 Vdc Output; 33 W to 66 W

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

VRLA Batteries. Battery Installation And Start up Guide

innovations in battery charging

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

MOTORTRONICS Solid State AC Motor Control

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

GSL Electronics Modified Sine Wave Power Inverters

GMT Fuse Panel Installation Guide

BR62 Battery Rack Installation, Operation, & Maintenance Manual

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide

M Series External Battery Frame. User Guide

Type 947D Polypropylene, High Energy Density, DC Link Capacitors

STR3. Step Motor Drive. User Manual

Temperature controller. Side. Vac 3. Typically. Temperature controller. Side. Vac Driving SSR. Temperature controller. Resistor. Vac.

CDBR-B. Dynamic Braking Unit Instruction Manual. April 2009 Part Number: R1 Copyright 2009 Electromotive Systems

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

USER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

DC POWER SUPPLY ALIMENTATION C.C.

DYNAMIC BRAKING (DB) OPTION

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Owner s Manual. PowerVerterDC-to-AC Inverter

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

Metrosil / Resistor Module Features Application Operation

Kinetics Industries Inc. 140 Stokes Ave. Trenton, NJ Fax

The Power of Reliability INSTRUCTION MANUAL

DR8010 tm. Hardware Reference Manual. Document Revision B4 May 15, 2018

EV Power - Battery Control Unit Instructions. 8 Cell 24V

X100P Load Bank. Read all instructions before using the load bank. Contents

LV Capacitor CLMD03 Power Module Instruction manual

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

Transcription:

USER MANUAL Maxwell Technologies BOOSTCAP 56V UPS Energy Storage Modules Models: BMOD0130 P056 B02 BMOD0130 P056 B03 Document Number 1017025 Notice: The products described herein are covered by one or more of the following patents: 7307830, 7203056, 7027290, 7352558, 7295423, 7090946, 7508651, 7492571, 7342770, 6643119, 7384433, 7147674, 7317609, 7495349, 7102877 2010-11 Maxwell Technologies Inc.

1. Introduction The 56 Volt UPS energy storage modules are self-contained energy storage devices comprised of twenty-three individual ultracapacitor cells. The module includes bus bar connections and integrated cell voltage management circuitry. Units may be connected in series to obtain higher operating voltage, in parallel to provide higher current or longer run time, or a combination of series/parallel arrangements as needed. The module is intended for installation in a standard 19 equipment rack or a 23 UPS rack. The module is designed to provide short term backup power (module power ratings are for 15 second discharge) for graceful shutdown of systems, for ride through of power transients (sags, spikes, dropouts), and for transition to a permanent backup solution such as a fuel cell or diesel generator. The module is intended for occasional charge/discharge (typically less than once per hour) as it contains no active cooling features. To meet the lifetime requirements, the maximum operating temperature is 40 C/104 F and 56V per module. The absolute maximum operating conditions are 65 C/149 F and 62V. The cell voltage management provides the highest reliability for controlling overvoltage conditions. Passive circuits are always operating to help prevent overvoltage conditions. An optional alarm circuit is available which provides an open collector signal when the voltage exceeds 2.7V on any cell in the module (see section 6.2). Ultracapacitors function on electrostatic principles with no chemical reactions and no moving parts. They avoid the lifetime issues associated with chemical storage in batteries or mechanical issues associated with kinetic energy storage. The 56 Volt UPS modules are non-toxic and designed for years of maintenance-free operation. 2. Unpacking Inspect the shipping carton for signs of damage prior to unpacking the module. Damage to the shipping carton or module should be reported to the carrier immediately. Remove the module from the shipping carton and retain the shipping materials until the unit has been inspected and is determined to be operational. NOTE: The original shipping materials are approved for both air and ground shipment. module should be removed from the shipping carton by lifting it by the body of the module. The The shipping container should contain the following: 1 x Energy Storage Module 1 x Accessory Kit consisting of: M8 and M10 connector bolts 2010-11 Maxwell Technologies, Inc. Page 3

1 x Users Manual The following accessories are included with the B03 option: 1 x Deutsch connector shell 2 x crimp-on receptacles 1 x Deutsch wedgelock If the unit is found to be defective or any parts are missing, contact your supplier. A Return Material Authorization (RMA) number must be issued prior to returning the unit for repair or replacement. 3. Safety WARNING DANGER HIGH VOLTAGE HAZARD! Never touch the power terminals as the module can be charged and cause fatal electrical shocks. Always check that the module is fully discharged before manipulating the module. For more information about the discharge procedure, please refer to Paragraph 7.1. Do not operate unit above specified voltage. Do not operate unit above specified temperature rating. Do not touch terminals with conductors while charged. Serious burns, shock, or material fusing may occur. Protect surrounding electrical components from incidental contact. Provide sufficient electrical isolation when working above 50 V DC. Prior to installation on and removal from the equipment, it is mandatory to fully discharge the module. 2010-11 Maxwell Technologies, Inc. Page 4

4. Installation 4.1 Mechanical Figure 1. Three modules mounted in a 24" rack. Modules are intended for installation horizontally as shown in Figure 1. The module should be mounted on a shelf. The modules should further be secured to the rack using the front or side mounting holes. See the data sheet for available mounting locations. 2010-11 Maxwell Technologies, Inc. Page 5

Figure 2. View of side and front mounting holes. The 56V UPS Energy Module has eight M5 mounting holes. Four of these holes are shown in Figure 2. Refer to Figure 3 for the location of mounting holes. Figure 3. Drawing with locations of mounting holes. 2010-11 Maxwell Technologies, Inc. Page 6

Figure 4a. Example mounting bracket with hole. Figure 4b. Example mounting bracket with slot. Bracket must not contact housing 50mm Figure 4c. Example mounting bracket from front. Must have wraparound to avoid contact with plastic. Figure 4d. 50mm max width to avoid contact with plastic, or add spacer between bracket and plastic housing 4.2 Mounting Bracket Requirements for Seismic Zone 4 Compliance Minimum of 4 holes must be utilized to effectively mount the 56V Module. o Two front AND two back OR o Two left AND two right Bracket must contact face of brass insert and not make contact with plastic housing. 2010-11 Maxwell Technologies, Inc. Page 7

Maximum hole size of 6.0mm to ensure bracket tightens against face of brass insert. If a slot is used, a washer with a maximum hole diameter of 6.0 mm should be included, as shown in Figure 4b. M5 size screws with a maximum engaged thread length of 9 mm must be used. Maximum torque is 3 N-m. 5. Electrical WARNING CAUTION To avoid arcing and sparking the energy storage module should be in a discharged state and the system power disconnected during installation. The module is shipped discharged and with a shorting wire. The shorting wire should be removed prior to electrical connection. WARNING CAUTION To provide the lowest possible ESR the energy storage modules are not fused. Care should be taken within the application to prevent excessive current flow as required. Excessive current and/or duty cycle will result in overheating the module which will cause irreparable damage. Please consult the specific data sheet for each module for current and duty cycle capabilities. 5.1 Output Terminal Posts The output terminals of the module consist of internally threaded aluminum posts. Maximum thread depth is 16 mm. They are designed to connect directly to a ring lug or a bus bar. Apply a layer of high conductivity aluminum-aluminum anti-oxidant joint compound between the mating surfaces. For example, Noalox Anti-Oxidant Compound available from IDEAL is a viable choice. There are many other vendors that supply an equivalent compound.. The positive terminal is threaded for a M8 x 1.25 steel bolt (provided). The negative terminal is threaded for a M10 x 1.5 steel bolt (provided). When applying torque to the terminals, it is recommended to use a maximum torque of 20 N-m / 14.8 ft-lbs for the M8 and 30 N-m / 22.1 ft-lbs for the M10 bolts. 2010-11 Maxwell Technologies, Inc. Page 8

Anti-rotation features within the module prevent damage to the terminals when applying torque to the bolts. Attachment to the output terminals should be made with ring lugs or bus bars of an appropriate size for the application current. The energy storage modules have low ESR. As a result, the resistance of the cable connecting the energy storage module to the load can easily exceed the ESR of the module. Connection of modules in series or parallel or combination thereof should utilize the same gauge wire (or equivalent bus bar) as determined for final output connections. When connecting in series, connect the positive output terminal of one module to the negative output terminal of the next module (as shown in Figure 5 and Figure 7). For parallel connections, connect positive terminals together and negative terminals together (as shown in Figure 6 and Figure 7). The maximum operating voltage of a series connected system should not exceed 750V. Figure 5. Series connected modules (horizontal or vertical). In this example, the system would provide 30KW for 15 seconds at 168V maximum voltage. Figure 6. Parallel connected modules (horizontal or vertical). In this example, the system would provide 30KW for 15 seconds at 56V maximum voltage. 2010-11 Maxwell Technologies, Inc. Page 9

Figure 7. 3 Series x 2 Parallel connect modules. In this example, the system would provide 60KW for 15 seconds at 168V maximum voltage. 5.1.1 Module to Module Balancing The modules are equipped with a passive voltage management circuit that protects every cell within the module. Module-to-module balancing is not required. 5.2 Thermal Performance Low internal resistance of the energy storage modules enables low heat generation within the modules during use. As with any electronic component, the cooler the part operates the longer the service life. In most applications natural air convection should provide adequate cooling. In severe applications requiring maximum service life, forced airflow may be required. The thermal resistance, R th, of the units has been experimentally determined assuming free convection at ambient (~ 25 o C). The R th value provided on the data sheet is useful for determining the operating limits for the units. Using the R th value a module temperature rise can be determined based upon any current and duty cycle. The temperature rise can be expressed by the following equation. Δ T = I 2 R esr R th d f where: I = current RMS AC or DC (amps) R esr = resistance R ac for AC current or R dc for DC current (ohms) R th = thermal resistance ( o C/W) d f = duty cycle fraction This ΔT plus ambient should remain below the specified maximum operating temperature for the module (please refer to the module datasheet). 2010-11 Maxwell Technologies, Inc. Page 10

6. Operation 6.1 General The module should only be operated within specified voltage and temperature ratings. Determine whether current limiting is necessary on input/output based on current ratings of ancillary devices. Observe polarity indicated on module. Reverse polarity operation of the module(s) is not recommended. Electric isolation of the module is tested to 3500 VDC for maximum operating voltage of 750 VDC. When several modules are connected in series for operating at higher voltage, care must be taken to ensure proper creepage and clearance distances in compliance with national safety standards for electrical equipment. 6.2 Overvoltage Logic output (B03 models only) A single open collector logic output is available for overvoltage monitoring. This output will indicate if any cell in the module has gone into an over voltage condition. The over voltage signal is available via the connector supplied on the module. The logic output is isolated from the capacitor voltages. When multiple modules are installed, the logic outputs may be monitored individually or wire-or d to provide a single fault line. A table indicating the pin out, indication and maximum current is provided below. The maximum open circuit voltage is 5.5 VDC. NOTES: Pin Maximum Name Output # current 1 GRND 2 Overvoltage High Inactive 5 ma Low Active 3 Not used N/A N/A 4 No used N/A N/A 1. The Overvoltage pin will go active if any one cell goes into an over voltage condition, 2.7V nominal threshold 2. The signal Overvoltage (Pin 2) is an open collector output indicating when any cell voltage is above the threshold voltage. A pull-up resistor ( 1kΩ) connected to a 5V supply should be connected to Pin 2. In this configuration, the voltage at Pin 2 will be ~ 5V when the circuit is not active. When a cell in the module goes into an over-voltage condition, the output of Pin 2 goes low. This signal can be used as a signal to the system electronics to stop charging in order to allow the cell(s) to discharge to an acceptable voltage through the built-in passive balancing system. Figure 8 shows a typical connection to use this system. 3. The Overvoltage circuit can sink up to 5 ma with a V OL of no more than 0.4V. The leakage current when the output is off is 50 na. The proper value of the pull-up resistor should be calculated based upon overall system circuit design. 2010-11 Maxwell Technologies, Inc. Page 11

Figure 8. Typical connection to the monitor cable. (Users to verify values based on their circuit design). The mating connector parts for the output logic are provided in the accessory kit. The connector is designed for 22 gauge wire; if the wire length required is longer than 6 feet, a shielded cable is recommended. 7. Safety WARNING DANGER HIGH VOLTAGE HAZARD! Never touch the power terminals as the module can be charged and cause fatal electrical shocks. Always check that the module is fully discharged before manipulating the module. Please refer to the step by step instructions below for the manual discharge procedure. Do not operate unit above specified voltage. Do not operate unit above specified temperature rating. Do not touch terminals with conductors while charged. Serious burns, shock, or material fusing may occur. Protect surrounding electrical components from incidental contact. Provide sufficient electrical isolation when working above 50 V DC. Prior to installation on and removal from the vehicle or equipment, it is mandatory to fully discharge the module to guarantee the safety of the personnel. 2010-11 Maxwell Technologies, Inc. Page 12

WARNING A fully discharged module may bounce back if it is stored without a shorting wire connected to the + and terminals. This bounce back can be as much as 7.5V for the 56V module. 7.1 Discharge Procedure Proceed as follow to discharge the module: 1. Using a voltmeter, measure the voltage between the 2 terminals. 2. If the voltage is above 2V, a resistor pack (not supplied with the module) will need to be connected between the terminals. Proper care needs to be taken in the design and construction of such a dissipative pack. e.g. At 56V, for a 2 Ohm pack, the module will be discharged with a peak current of 28A and will take about 15 minutes to discharge. However, in this case, the heat/power dissipated in the resistor pack will be ~ 3.9kW. The resistor pack will need to be sized and provided with suitable cooling to handle this power dissipation. Additionally, proper enclosure or other packaging is necessary to ensure safety. In all cases, proper design of the dissipative resistor pack is necessary. 3. If the voltage is under 2V, connect the shorting wire provided by Maxwell (or similar wire) to the + and connectors. 4. The module is now safe for handling. However, leave the shorting wire connected at all times until the module is installed in the system and the power cables are connected. 8. Maintenance Prior to removal from the system, cable removal, or any other handling ensure that the energy storage module is completely discharged in a safe manner. The stored energy and the voltage levels may be lethal if mishandling occurs. Maintenance should only be conducted by trained personnel on discharged modules (Paragraph 7.1). 8.1 Routine Maintenance 8.1.1 Clean exterior surface of dirt/grime 8.1.1.1 Reason - Improve power dissipation performance. 8.1.1.2 Use a cleaning cloth dampened with a water/soap solution. Do not use high-pressure sprays or immersion 8.1.1.3 Frequency 8.1.1.3.1 Annually 2010-11 Maxwell Technologies, Inc. Page 13

8.1.2 Check mounting fasteners for proper torque 8.1.2.1 Reason - Avoid mechanical damage 8.1.2.2 Frequency 8.1.2.2.1 Annually 8.1.3 Inspect housing for signs of damage 8.1.3.1 Reason allows potential internal damage to be identified 8.1.3.2 Frequency 8.1.3.2.1 Annually 8.1.4 Check signal/ground connections 8.1.4.1 Reason avoid false signals or shock hazards 8.1.4.2 Frequency 8.1.4.2.1 Annually 9. Storage The discharged module can be stored in the original package in a dry place. Discharge a used module prior to stock or shipment. A wire across the terminals should be used to maintain short circuit after having discharged the module. 10. Disposal Do not dispose of module in the trash. Dispose of according to local regulations for general electronics waste. 11. Specifications Refer to datasheets at http://www.maxwell.com for specifications. 2010-11 Maxwell Technologies, Inc. Page 14

Contact Information: Maxwell Technologies, Inc. Global Headquarters 5271 Viewridge Ct, Suite 100 San Diego, CA 92123 USA Phone: +1 858 503 3300 Fax: +1 858 503 3301 Maxwell Technologies SA CH-1728 Rossens Switzerland Phone: +41 (0)26 411 85 00 Fax: +41 (0)26 411 85 05 Maxwell Technologies GmbH Brucker Strasse 21 D-82205 Gilching Germany Phone: +49 (0)8105 24 16 10 Fax: +49 (0)8105 24 16 19 Maxwell Technologies, Inc. Shanghai Representative Office #13E, CR Times Square 500 Zhangyang Road, Pudong Shanghai 200122, P.R. China Tel: +86 21 5836 8780 Fax: +86 21 5836 8790 www.maxwell.com 2010-11 Maxwell Technologies, Inc. Page 15