L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

Similar documents
Operating Manual Includes Pumps: PG-9000 Part #R809606

PL Submersible, Semi-Vortex, Water Feature Pump

AUTOMATIC SUBMERSIBLE UTILITY PUMP

SuperFlo 9,000 High Volume Pump Product Manual

GeyserMax-Flow Series

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Matala. VersiFlow Series. Instruction and Maintenance Manual

Owner s Manual Drill and Light Weight Portable Utility Pumps

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

OPERATION MANUAL TSURUMI MANUFACTURING CO., LTD.

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

SUBMERSIBLE PUMP HSE RANGE

Installation & Operating Manual

Powerful & Intelligent Submersible Pumps

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

SUBMERSIBLE PUMP HSE RANGE

SUNC3000 / Item #40885

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

Owners Manual: - Pumps

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

en Pump PS PS OPERATOR S MANUAL

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

SUBMERSIBLE DIRTY WATER PUMP

en Pump PS OPERATOR S MANUAL

GARDEN HOSE UTILITY PUMP

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

KTV/NK Series. Submersible General Dewatering Pump OPERATION MANUAL

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

Instruction Manual. * We reserve the right to amend specification without prior notice.

StormPro BA Series Sump Pump

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Instruction Manual. * We reserve the right to amend specification without prior notice.

en Pump PSR1 500 OPERATOR S MANUAL

Thank you for selecting the GD submersible grinder pump.

OPERATION & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

ESE Series Cast Iron Sewage Pumps

INSTALLATION & OPERATION MANUAL

OPERATION & MAINTENANCE INSTRUCTIONS

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

SUPER PUMP OUT SYSTEM

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

SUBMERSIBLE SUMP PUMP RANGE

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

1/2 HP SUMP PUMP OWNER'S MANUAL

OWNER S MANUAL. Evolution Series Fountain. 1/2 hp, 115V, 60 Hz

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

GD series Submersible Grinder Pump

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

SUBMERSIBLE WATER PUMPS

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Product Manual Manuel du Produit Manual del Producto

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

SUBMERSIBLE WATER PUMP

Owner s Manual & Safety Instructions

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752

PRE-PLUMBED SEWAGE SYSTEM

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

User s Manual. Automatic Switch-Mode Battery Charger

SUBMERSIBLE WATER PUMP

SUBMERSIBLE MINI-PUMP

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM

HALLMARK INDUSTRIES INC

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Submersible Sump/Drainage Pump

115 VOLT TRANSFER PUMP

ALITA INDUSTRIES, INC. Efficient and Reliable Air Moving Products ALITA LINEAR AIR COMPRESSORS OPERATION & MAINTENANCE MANUAL

StormPro BCV400 Sewage Ejector Pump

TSURUMI MANUFACTURING CO., LTD.

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)

barmesapumps.com 2AHS 0.5 & RPM Installation, Operation & Maintenance Manual Submersible Dewatering Pumps

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

Submersible Pump Instructions. Safety Instructions

BATTERY SAVER LOW RIPPLE HO

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

STEP-BY-STEP INSTALLATION GUIDE

WEDA PUMP. Submersible Water Pump WP300 INSTRUCTIONS & SPARE PARTS CATALOGUE WP300_ ENG_1

ALITA LINEAR AIR COMPRESSORS INSTRUCTION MANUAL

Product Manual Manuel du Produit Manual del Producto

Transcription:

L-SERIES PUMPS Operating Manual Includes Pumps: L-305 L-310 1-877-80-PONDS www.atlanticwatergardens.com

Introduction Thank you for selecting the TidalWave L-305/L-310 series pumps. Before using this pump please take a moment to review this manual. To avoid an accident do not use the pump in any way other than as described in this manual. Please note the manufacturer cannot be responsible for accidents arising because the product was not used as prescribed. After reading this manual keep it as a reference in case questions arise during use. Using the pump in a manner that is not prescribed will void the warranty. Model # L-305 (gph) (gpm) L-310 (gph) (gpm) Max 5 10 15 20 25 30 35 40 45 50 55 60 10380 7380 3960 190 173 149 13500 10560 7380 3240 237 225 201 176 * Operating pumps outside of the recommended range may cause bearing damage and premature failure. * Never operate L-Series pumps at total dynamic head heights exceeding 15 feet. Best Efficiency Point Recommended Operating Range Do Not Operate Range Prior to Operation and Installation When the pump is delivered, first perform the following checks: Check for any damage to pump and power cable that may have occurred during the shipment. Check the model number to make sure it is the product that was ordered and verify the voltage and frequency are correct. Caution DO NOT operate this product under any condition other than those for which it is specified. Failure to observe this precaution can lead to electrical shock, electrical leakage, fire, water leakage or other problems. L-305/L-310 pumps require a single phase 115 volt / 60 hz power supply. Always verify that the supplied power meets the requirements listed on the upper pump cover. 2

DO NOT apply any paint over the stainless steel motor body. Reduced cooling ability will result in overheat, overload, introduce undesirable performance reductions, periodic auto shut-off and pump malfunction. Never place your hand or any object in or near the inlet opening while this equipment is operating. If pump inlet is clogged, always turn off the power supply, fuse box or circuit breaker and wait until the motor is completely stopped before attempting to remove any clogged material. Please make sure that the power plug and the AC outlet receptacle is protected and away from water or pump discharge hose to prevent accidental electric shock or short circuit. Always operate the pump completely submerged in water. Avoid dry operation, which will not only lower performance but can cause the pump to overheat/malfunction, leading to electrical leakage, shock or premature failure. CAUTION: THIS PUMP IS TO BE USED IN A CIRCUIT PROTECTED BY A GROUND CIRCUIT INTERRUPTER. ATTENTION: CETTE POMPE DOIT ETRE BRANCHEE A UNE DERIVATION PROTEGEE PAR UN DISJONCTEUR DIFFERENTIEL. CAUTION: THIS PUMP HAS BEEN EVALUATED FOR USE IN WATER ONLY. Before You Start Check the model name plate to make sure once again that the product is of the correct voltage and frequency rating. The setting on the circuit breaker or other overload protector should be made in accordance with the rated currency of the pump. Turn off the power supply or circuit breaker before inserting the power supply plug to avoid electrical shock, shorting, or unexpected starting of the pump, which could lead to injury. Never operate the pump while it is suspended in air. The recoil may result in injury or other major accident. 3

Electrical Safety Electrical wiring should be installed by a qualified electrician in accordance with all applicable safety regulations. Incorrect wiring can lead to a pump malfunction, electrical shock or fire. Pumps should operate on a designated, circuit rated at 15 Amps (minimum). Pump must be protected by a ground fault circuit interrupter (GFCI). Pump must be plugged into a standard, properly grounded, three pronged outlet. Do not cut the electrical cable. If a cable with cut insulation or other damage is submerged in water, there is danger of water seeping into the pump motor and causing a short. This may result in damage to the pump, electrical shock or fire. Altering the electrical cable in any way will void the warranty. Never move or handle the pump by pulling on the electrical cable. Make sure the electrical cable does not become excessively bent or twisted, does not rub against a structure in a way that might damage it, and does not come in contact with heated surfaces. Operation In case of a power outage, turn off the power to the pump to avoid having it start unexpectedly when the power is restored. L-Series pumps are cooled internally as the water flows around the motor. The intake screen on L-Series pumps must be completely submersed during operation. In case of very excessive vibration, unusual noise or odor, turn off the power immediately and consult with your nearest dealer. Continuing to operate the pump under abnormal conditions may result in electrical leakage, electrical shock or fire. Motor Protection System The pump has a built-in motor protection system. The following reasons may cause the pump to stop automatically regardless of water level. 4 Motor overheating Excessive current Change in voltage polarity Open-phase operation or operation under constraint

Repeating cycles of stopping and restarting will damage the water pump. Do not continue operation at low lift, low water level, or while the inlet is clogged with debris. Not only will performance suffer, but also such conditions may cause noise, heavy vibration, and pump failure. Maintenance and Inspection Regular maintenance and inspections are a necessity for continued efficient functioning. If any abnormal conditions are noticed, refer to the section on Troubleshooting and take corrective measures immediately. During or after the warranty period, the customer is NOT to disassemble the pump for any reason. Monthly Inspection Check for any drop in performance. Reduced performance is usually caused by debris blocking the intake screen. Detach the power cable from the receptacle and turn off the power supply (circuit breaker). Disconnect the pump discharge and remove the pump from the water. Remove any accumulated debris from the surface of the pump, inlet screen and impeller. Make sure all nuts and bolts are fastened securely. Do not disassemble the pump for any reason. Disassembly will void the pump warranty. Refer operating and maintenance problems to a qualified technician. Winterizing Under no circumstances should the pump be left in frozen water. When the pump is out of use for an extended period, wash it and dry it thoroughly, then store it indoors. Note: Always run a test operation before putting the pump back into operation. When the pump is left installed in water it should be run at regular intervals (about once per week). 5

Warranty All TidalWave Pumps carry a two-year limited warranty. This limited warranty is extended solely to the original purchaser commencing from the date of original purchase receipt and is void if any of the following apply: The pump has been run while not fully submersed causing the thermal protection to trip. Skimmers using inadequate vertical filtration may create run dry conditions. The pump was not run on a dedicated circuit. The cord has been cut or altered. The pump has been misused or abused. Serial number tag has been removed. The pump has been fully or partially disassembled. Warranty Claims In case of warranty claims, pump should be returned to place of purchase accompanied by original receipt. 6

1 3 5 7 2 4 6 8 10 9 11 13 14 12 15 16 17 20 21 23 18 19 22 24 25 26 27 NO. Description NO. Description NO. Description 1 Outlet 2 Cable 3 Upper Cover 4 Handle 5 Capacitor 6 Cable Sleeve 7 Upper Bearing 8 Cable Base Cover 9 Bracket 10 Auto-cut 11 Motor Frame 12 Shaft (with rotor) 13 Stator 14 Outter Cover 15 Lower Bearing 16 Lubricant 17 M. Seal Bracket 18 Oil Plug 19 M. Seal 20 Casing 21 Oil Seal 22 Oil Seal Bush 23 Impeller 24 Impeller Key 25 Wear Ring 26 Strainer 27 Footing 7

Troubleshooting Guide Always turn off power before inspecting the pump. Failure to observe this precaution can result in a serious accident. Before ordering repairs, carefully read through this instruction booklet. If the problem persists, contact your dealer. Problem Possible Cause Possible Solution Power is off Turn power on Pump does not start Power failure Voltage drop/ Overload Check power supply or contact local power company Check/Replace the GFI (Ground Fault Interrupter) Power cord is not connected Connect power cord Pump is overheating Submerge pump/raise water level/ Allow pump to cool Pump stops after starting Power/Current overload Check length/size of power cable. Check or replace GFI Impeller is blocked Remove debris from the impeller chamber Diminished flow rate or no water flow Air lock Obstruction in pump or piping Piping is too long Restart/Clean air valve Clear obstruction Reduce length of pipe 1-877-80-PONDS www.atlanticwatergardens.com