FHSCP-UNV-10P-L-SD SPECIFICATIONS

Similar documents
FHSCP-UNV-10P-L-SD INSTALLATION INSTRUCTIONS

FHS2-UNV-36L INSTALLATION INSTRUCTIONS

FHS2-UNV-56S SPECIFICATIONS

This Driver Will Operate Constant Current LED Arrays With a Working Voltage Between 11-56VDC And Not Exceeding 20W.

Cat# DC LED Array Emergency Driver

FHEZ10A24 FHEZ10A24 - CEC 24" EZ EXIT EM T-Grid

TRMUNV065EC8XXA TRAUNV065EC8XXA Universal Voltage LED Canopy Retrofit Kit

MODEL : FHS2-UNV-36L

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

VKMUNV018RDxxxA. UNV DC Engines Retrofit Kits with 0-10V Dimming Universal Voltage (120~277) DC Engine

SPECIFICATION SHEET : FHS2-UNV-36L

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

Installation and Operation Instructions 10/04/13

IMPORTANT SAFEGUARDS

Installation Instructions Central Battery Units

Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

SURE-LITES FBP140XLP Instruction Manual

120VAC / Universal Input Half Round LED DC Engines and LED DC Engine Retrofit Kits

LED Driver Selection Guide

LED Driver Selection Guide

120VAC / Universal Input Round LED DC Engines and LED DC Engine Retrofit Kits

UL AND CODE COMPLIANCE

Self-Testing Industrial Series

OPTOTRONIC Programmable LED Emergency Driver and Battery Pack

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Spectron Industrial Series

TJT120034ACxxxB TJT120034ACxxxC 120V LED DirectAC Engine and Retrofit Kits

TJT120015ACxxxB TJT120015ACxxxC 120V LED DirectAC Engine and Retrofit Kits

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

Emergency and Exit Solutions

LED Retrofit Kits Vol. 1

Emergency and Exit Solutions Product Selection Guide. LED Emergency Backup Fluorescent Emergency Ballasts Emergency Lights & Exit Signs

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Europe Featured Products Catalogue

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Technical specification. POW12V20A-D1 Charger. LFP/LTO + BMS connector

EMIU 720W Mini Inverter

Technical specification. POW48V10A-D1 Charger. LFP/LTO + BMS connector

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

VR22-MU-xxx-8yy-xxxxA

SAVE THESE INSTRUCTIONS

Technical specification. POW24V20A-D1 Charger. LFP/LTO + BMS connector

15W (+/- 1W) 5.08" diameter x 0.75 H. Energy Star Luminaire CSD

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

TMU040005ELXXXA TMU040005ELXXXB

TMU040010ELXXXA TMU040010ELXXXB TMU040010ELXXXC

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

34W (+/- 1W) 9.55" diameter x 0.81 H. 2.5kV Common and Differential mode (Per ES Ring Wave Test) Sound Rating / Noise

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

23W (+/- 1W) Leading Edge (TRIAC) or Trailing Edge (ELV) /100% ~ 10% Beam Angle CRI Operating Temperature Range (Ta) Maximum Engine Case Temperature

FieldView External Charger. User Guide

EXP-EMG-2L-LE6. Explosion Proof Bug Eye Emergency LED Fixture Instruction Manual

VR44-MU-xxx-8yy-xxxxA

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

350 ma CONSTANT CURRENT LED DC MODULE, 17 LINEAR, 1845 LUMENS

LED. High-performance streetlight. -afortable and reliable

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

MIRRORLITE RECESSED EMERGENCY LIGHTING

V4 Cordless Lamp System User Guide

Product Installation Document

Uninterruptible Power Supply

Installation Instructions

POW72V35A/BMS CHARGER SPECIFICATION

62.6g / 0.13lbs. RoHS Compliant Dry and Damp Location IC Over Temperature Control

Lithium Power Supply

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Nova UAC (NV-UAC-M) Modified Sine Wave 650W 800W 1000W

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

MANUAL. Single charger

SAVE THESE INSTRUCTIONS

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Twelve Unit Rapid Charger

SMP3CTX Series Power Supply/Charger

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

Installation Manual. Integrated Prepaid Keypad Meters. For HXE34-KP Meters(CT & CTPT Connection) Hexing Electrical Co., Ltd. [2013.

Installation Instruction

SPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks

Installation and Operations Manual

AWZ 110. AWZ 13,8V/1A/7Ah/LM

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Mini-Roto TM Paddle Wheel Installation & Operation Manual

Operating Instructions

MaxLite LED UTILITY WRAP FIXTURES

Transcription:

SPECIFICATIONS Emergency LED Driver Universal Voltage: 100-277VAC, 50/60Hz Output Wattage: 1-10W Output Current: 620mA Max. Long Case and Terminal Output voltage range of 16-55VDC This Driver Will Operate The Following LED Modules: Any LED module designed to accept input voltage range of 16-55VDC and can operate up to current of 620mA. General Specifications Input Voltage Input Current Input Power Standby Input Power Driver Type Output Current Output Voltage Range Output Power Number of Output Channels RFI/EMI Output Type Battery Type Battery Capacity Available Battery Recharge Time Battery Discharge Time Ambient Operating Temperature Range Sound Rating Input Surge Protection Protections Service Life Approvals / Class 100-277VAC, 50/60Hz 0.06A Max. 6W <0.5W Constant Power 620mA Max. 16-55VDC 1-10W (1-10W @ 3000mA Battery, 1-6W @ 1800mA Battery, 1-5W @ 1500mA Battery) 1 Channel FCC Part 15A Non-Consumer Class 2 9.6VDC 3000mAh, 1800mAh, 1500mAh 12 Hours (Refer To Battery chart) 90 Minutes Min. 10 C to 55 C (50 F to 131 F) A Line-Neutral 2kV, Line & Neutral-Ground 2kV Over / Under Voltage Protection Output Open Circuit Protection Overload Protection 50,000 hours RoHS,, CEC Title 20 Mechanical Data Tolerance=±0.02" Page1of8

GENERAL INSTALLATION GUIDELINES FOR LED EMERGENCY DRIVER IMPORTANT SAFE PRACTICES When using electrical equipment and this lighting device basic safety precaution should be followed at all times including but not limited to the following: PLEASE READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY IMPORTANT: Do not connect battery until fixture is installed. IMPORTANT: An un-switched AC power source of 100VAC to 277VAC is required. This device is designed for use in fixtures listed for dry and damp locations. CAUTION: Make sure all electrical connections conform to the National Electrical Code and all applicable local regulations. CAUTION: Do not let power supply cords touch hot surfaces. CAUTION: Do not mount near gas or electric heaters. CAUTION: Do not use outdoors. CAUTION: Battery is rechargeable type and must be recycled or disposed of properly. Do not use this emergency driver with accessory equipment other than recommended by manufacturer; failure to follow this may cause an unsafe condition. Servicing should only be performed by qualified service personnel. Do not use this emergency driver for other than intended use. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. IMPORTANT: Indicator (LED light) illuminated indicates battery in charge mode when AC power is applied. It is recommended and required by applicable code to test emergency function to ensure proper operation of the system; push the test switch for thirty (30) seconds every 30 days to ensure the emergency driver is functioning as LED light source illuminated. Conduct a ninety minute (90) discharge test one time (1) per year; LED light source should be illuminated for a minimum of ninety minutes (90). ASSEMBLY and FIELD INSTALLATION WIRING: WARNING: AC power must be off before proceeding with assembly or installation of emergency driver. TESTING SYSTEM: The emergency battery requires a charge minimum of one (1) hour before testing the circuit. A full charge requires twelve (12) hours. Fulham Head Quarters: Fulham Co., Inc 12705 South Van Ness Ave. Hawthorne, CA 90250 Manufacturer: North China Fulham Electronic Co. Ltd. No. 9 Xingchang Road, Nanshao Zhen Changping Science Park, Beijing, P.R. China SAVE THESE INSTRUCTIONS Page2of8

SELF DIAGNOSTIC INSTRUCTIONS / OPERATION: The self diagnostic feature is factory enabled. The emergency LED driver will conduct a self check for thirty (30) minutes every thirty (30) days and ninety (90) minutes every 12 months. After every self check the LED indicator light will indicate a status signal. A single self-diagnostic test can be activated by pressing the test switch three (3) times. Refer to table 1 for details. The self diagnostic feature can be disabled by using the TPSB-100 SmartSet controller or by using the Smart Set software. The output emergency power is programmable up to 10W for a minimum of 90 minutes (refer to battery chart for information on max load ratings of batteries). TABLE 1 - Self Diagnostic Indications LED Indicator Description LED Indicator Status Signal Description of Status Signal Comment Permanent Green ON System OK AC mode Slow Flashing Green 1.0s ON and 1.0s OFF Self-Diagnostic test underway Flashing Red 4.0s ON and 1.0s OFF Battery not connected Connect the battery Slow Flashing Red 1.0s ON and 1.0s OFF Battery failure Change the battery Fast Flashing Red 0.1s ON and 0.1s OFF Charge circuit is broken Change the driver Green and Red Off OFF (With LED Load ON) DC mode Battery operation (emergency mode) Note: Can take up to one minute for status to be updated when issue is corrected. TPSB-100: For detail information on using TPSB-100 Driver Programming Box, please consult user s manual of TPSB-100. Page3of8

Wiring Diagrams 1 TEST TO LED Driver L N GND FHSCP-UNV-10P-L-SD PRG (-) PRG (+) LED (-) LED (+) To LED Driver Output (-) To LED Driver Output (+) BATTERY LINE WALL WHITE(COMMON) GND TO LED Driver BLACK WHITE LED DRIVER RED (+) BLUE (-) Driver Must Be Grounded + - NOTE: DRILL ½ (12.7mm) DIA. HOLE IN MOUNTING PLATE TO INSERT TEST + - LED (+) LED (-) TEST Page4of8

Wiring Diagrams 2 LINE WALL BLACK WHITE LED DRIVER RED (+) BLUE (-) Driver Must Be Grounded NOTE: DRILL ½ (12.7mm)DIA. HOLE IN MOUNTING PLATE TO INSERT TEST TEST Page5of8

Wiring Diagrams 3 TEST TO LED Driver L N GND FHSCP-UNV-10P-L-SD PRG (-) PRG (+) LED (-) LED (+) BATTERY LINE WALL WHITE(COMMON) GND TO LED Driver BLACK WHITE LED DRIVER RED (+) BLUE (-) Driver Must Be Grounded + - NOTE: DRILL ½ (12.7mm) DIA. HOLE IN MOUNTING PLATE TO INSERT TEST - + + - LED (+) LED (-) TEST Battery Chart Fulham Model No. Chemistry Compliant Pack Capacity Max Load for 90 min. Battery Voltage Recharge Time FHSBATL3-1.5-SD RoHS 1500mAh 5W 9.6V 12Hrs FHSBATL3-3-SD RoHS 3000mAh 10W 9.6V 12Hrs FHSBATL9-.6-SD RoHS 1800mAh 6W 9.6V 12Hrs FHSBATL6-1.5L-SD* RoHS 3000mAh 10W 9.6V 12Hrs CAUTION: Replace battery only with corresponding part number. * Note: These batteries do not include mounting means, separate mounting brackets are available. Page6of8

Battery Dimensions FHSBATL3-1.5-SD 5W, 1500mAh, 9.6V FHSBATL3-3-SD 10W, 3000mAh, 9.6V FHSBATL9-.6-SD 6W, 1800mAh, 9.6V Page7of8

Battery Dimensions FHSBATL6-1.5L-SD 10W, 3000mAh, 9.6V Mounting Bracket Dimensions (Optional) FHSBATSC6-1.5L Page8of8