Operator's manual ATSc Instrumentation en-gb

Similar documents
Remote engine start. Function

Flight Systems. Replacement for KASSEC DESCRIPTION

Remote engine start. Function. Behaviour. The remote engine start function is used to start the engine from outside the cab.

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

AUTOMATIC STAND-BY AND PEAK-LOAD CONTROL

Split shaft power take-off activation. General information

MLP2 - DUAL-BRANCH LUBRICATION SYSTEM

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

Adjustable parameters Signalling and visibility systems

Delomatic 400 GAS CHP controller TCP/IP Modbus communication

GENERATOR & SINGLE-FUNCTION PROTECTION

The measurements module provides the following engine features information:

Operator Manual. Transfer Switch. RSS100 and RSS Cummins Inc. All rights reserved. English

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

Accessories for power generation plants in Italy SMA GRID GATE

Parameters Powertrain

Remote activation of visibility and lighting functions

Deep Sea Electronics Plc

Komatsu Power Generation Systems

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list

4.2 Component Identification

DKG-109 AUTOMATIC MAINS FAILURE UNIT

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

ST Wiring diagram. Product description. Temperature controller. Order number

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

DKG-317 MANUAL AND REMOTE START UNIT

Slide Freedom Automatic Spray Unit Item # 43200

List of notes Powertrain

DEEP SEA ELECTRONICS PLC

Side marker lamps from the factory. General information

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

DKG-109J AUTOMATIC MAINS FAILURE UNIT

Release notes for Scania Diagnos & Programmer 3, version 1.17

MGE Galaxy PW kva 480 V. Operation

DEEP SEA ELECTRONICS PLC

8 Troubleshooting and Maintenance

DKG-509 AUTOMATIC MAINS FAILURE UNIT

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

Automatic Genset Controller, AGC-3 Functional description Display unit and menu structure PID-controller Procedure for parameter setup Parameter list

ControlReg200/ControlReg200P. Installation and maintenance

VOLUMETRIC BLENDING SYSTEM OPERATION MANUAL

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

ATC-400 Retrofit Kit for 240/120 or 208/120 V Automatic Transfer Switch Instruction Leaflet WARNING CAUTION CAUTION. Removal of ATC-200:

Activation of EG power take-off. Function

U n i n t e r r u p t i b l e P o w e r S y s t e m

MEGA WAY LCD PAGER ALARM WITH REMOTE ENGINE STARTER. Operation Manual MEGATRONIX CHATSWORTH, CA U.S.A. MEGA 2700 OPERATE 1

Documentation. RM-BV4 Micro DP. Filter control

Activation of a split shaft power take-off. Function

DEEP SEA ELECTRONICS PLC

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

DEEP SEA ELECTRONICS PLC DSE3210 Configuration Suite Software Manual

Installation Guide Programming Manual

CONCEPT 401 EC PRE-INSTALLATION INSTALLATION USER S MANUAL TECHNICAL MANUAL

Service Bulletin Buses

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

N1387 Series Troubleshooting Guide for N Alternators

825-P Modular Protection System for motors Specification Guide

REVISION HISTORY REVISION HISTORY

DKG-207 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT

TE2010-GE Instructions manual

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

User s Manual XOB15091 OBD II / EOBD CODE READER. All Rights Reserved. Warranty and Service

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Tower Electronic Systems

GCU-10. Automatic Engine Control Unit Operators Manual

DKG-707 MULTI GENSET PARALLELLING UNIT WITH J1939 INTERFACE

Visit for more technical information & downloads

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100

USER MANUAL FOR GC500 GENSET CONTROLLER SEDEMAC ABSTRACT

MicroGuard 586. Operation/Setup Manual MG-586. Crane Systems. Rated Capacity Indicator/Limiter System GREER COMPANY. Page 1 of 44

User Manual. Compact Tester II st Edition

CONTENTS ESC CONTENTS... 1 FEATURES... 2 LAYOUT... 3 DISPLAYS... 4 CONNECTIONS... 5 MENU... 6 MESSAGES... 7 SYSTEM OPERATION... 8

Advanced Genset Controller, AGC 200 Display readings Push-button functions Alarm handling Log list

Operator s Series 300 Generator Paralleling System

MEC 310 GENSET CONTROLLER

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

ST315B. User Handbook STAFFOR. ST315B Temperature Programmer. See separate handbook for Installation Instructions Issue: 2.00

Unit Protection System for Pumped-Storage Power Stations

DEEP SEA ELECTRONICS PLC

Te 804 Electronic Controller. Service, Operation & Technical Information Manual

Smart Key. User Manual

DKG-114 MANUAL AND REMOTE START UNIT

DEEP SEA ELECTRONICS PLC

Split shaft power take-off activation via BWS. General information about the function. Operation with the vehicle in motion and stationary

To ensure proper installation, digital pictures with contact information to before startup.

HGM6400 Automatic Genset Controller (With J1939 Interface) USER MANUAL Smartgen Technology

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT WITH PARALLEL TO MAINS AND DUAL GENSET PARALLEL FEATURES

S60. Quick GUIDE Web Edition

DEEP SEA ELECTRONICS PLC

AUTOMATIC AND MANUAL TRANSMISSION MODELS* *MUST USE M SERIES REMOTE STARTER!

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Powertrain Control Software

System Programming Instructions

Product Manual. Part Number: MVP-193 Mefi-6 ECU Revision: 1.0

SINGLE-PHASE PUMP START AND PROTECTION BOX Type V1M, V1N, V1E, V1F

DIESEL Engine Fire Pump Controllers Features

EMIU 720W Mini Inverter

Transcription:

Operator's manual ATSc Instrumentation en-gb 68 57 Issue.0

Preface................................ Function............................... Instrument panel........................ 4 Switch............................... 4 Indicator lamps........................ 5 Display with switches................... 6 Display................................ 7 Layout............................... 7 Navigation through the measured values for the parameters............................ 8 Alarm.............................. 0 Configuration mode................... Testing the instrument panel............. Test with load........................ Test without load...................... Components in the central electric unit.... OPM 60 en-gb Scania CV AB 0, Sweden

Preface Preface This Operator s manual describes operation of ATSc instrument panel. The information in this manual was correct at the time of going to press. Scania reserves the right to make alterations without prior notice. Note: Always use Scania spare parts for repair work. Function The instrument panel for the automatic transfer switch (ATS) can be used when a generator set is being used as a stand-by generator set in an electrical consumer network. The instrument panel is located in the switchgear of the electrical consumer network. When the instrument panel detects a power failure in the electrical power network, a signal is sent to the generator set requesting it to start and take over the load from the electrical consumers. When the instrument panel detects that the mains voltage is back up, the generator set stops. The display of the instrument panel indicates the voltages and frequencies of each phase, the engine running time, the next inspection, the number of times the generator has been connected and active alarm messages. Indicator lamps show the current operating mode, the status of the circuit breakers and the availability of mains voltage and generator voltage. The instrument panel can be run in both automatic and manual operating modes. OPM 60 en-gb Scania CV AB 0, Sweden

Instrument panel Instrument panel The figure below displays the instrument panel with switches, indicator lamps and display. V Hz h 7 8 9 4 0 5 6 8 7 STOP 6 4 5 05 Switch Item Switch Function 06 Acknowledges active alarm messages and cancels the alarm signal. Indicator lamp 4 goes out when there are no alarm messages. 4 5 07 08 050 Changes operating mode. In manual operating mode, indicator lamp 6 is on and in automatic operating mode indicator lamp 5 is on. This switch is deactivated when the operating mode has been selected externally. Closes or opens the circuit breaker in the generator set and in the automatic transfer switch respectively, depending on the current status of the circuit breakers. This switch is only active in manual operating mode. Starts the engine. This switch is only active in manual operating mode. If the instrument panel does not detect a generator voltage and frequency after 60 seconds, the Engine start failure alarm is triggered. This switch is deactivated when the instrument panel is in automatic operating mode or when the operating mode has been selected externally. OPM 60 en-gb 4 Scania CV AB 0, Sweden

Instrument panel Item Switch Function 6 STOP 09 Switches off the engine. This switch is always active. If the switch is pressed once the engine is switched off following a cooling period. If the circuit breaker in the generator set is closed and the circuit breaker in the automatic transfer switch is open when the switch is pressed, the former opens while the latter is closed, if there is mains voltage. If the switch is pressed twice the engine is switched off immediately. Indicator lamps Item Note: Function 9 The indicator lamp is on when mains voltage is available and it is within the limits. The indicator lamp flashes when mains voltage or frequency is not within limits. 0 The indicator lamp is on when the circuit breaker in the automatic transfer switch is closed. The indicator lamp is on when the circuit breaker in the generator set is closed. The indicator lamp is on when there is a generator voltage and frequency and they are within limits. The indicator lamp flashes when the generator voltage or frequency are not within limits. The indicator lamp is on when the engine is running. The indicator lamp flashes when the engine is running, but engine protection monitoring is not ready. The indicator lamp also flashes when the engine is in its startup or cooling phase. 4 The indicator lamp is on when there are alarm messages. 5 The indicator lamp is on in automatic operating mode. 6 The indicator lamp is on in manual operating mode. 7 The indicator lamp is on when the generator set is stopped. Press switches 7 and 8 at the same time to carry out a function test of all indicator lamps and the display. OPM 60 en-gb 5 Scania CV AB 0, Sweden

Instrument panel Display with switches Item Switch Function Scroll to show the monitored parameters on the display. This switch is active when the instrument panel is in normal operation. 00 7 Increase a value for the selected parameter when the instrument panel is in configuration mode. 0 8 Decrease a value for the selected parameter when the instrument panel is in configuration mode. 0 8 Alphanumeric display with 6 characters. Measured values, operating parameters and alarm messages are displayed here. OPM 60 en-gb 6 Scania CV AB 0, Sweden

Display Display Layout The display shows a number of numerical measured values during operation. Display with 6 characters 4 5 6 7 8 0 The first character in the display (from the left) shows the unit being measured: generator, automatic transfer switch or electrical power network. The second character in the display indicates the phase 8 being measured. The upper bar indicates L, the central bar indicates L and the lower bar indicates L. If only one bar is displayed the phase is being measured to neutral. If two bars are displayed, phase to phase is being measured. Characters to 6 indicate a numeric value with one decimal for the displayed parameter. The indicator lamps located above to the left by the first 4 characters indicate the following: Indicator lamp 4 on displays the unit of measurement voltage (V). Indicator lamp 5 on displays the unit of measurement frequency (Hz). Indicator lamp 6 on displays the number of running hours (h). Indicator lamp 7 on displays the number of times the generator has been connected (n). The example in the above figure shows that the generator voltage is 5.0 V between phase L and neutral. The bar in the first character indicates the unit generator. The bar in the second character indicates the measurement between phase L and neutral. Characters to 6 indicate the numerical value 5.0. Indicator lamp 4 on at the first character shows that the unit of measurement is voltage (V). OPM 60 en-gb 7 Scania CV AB 0, Sweden

Display Navigation through the measured values for the parameters With the instrument panel in normal operation the basic value is always displayed first when the instrument panel evaluates the measured voltage and the positions of the circuit breakers. Press switch to see the measured values of the parameters in the following sequence. Parameter Mains voltage V (V Line ). Mains voltage V (V Line ). Mains voltage V (V Line ). Mains voltage. Average of phase to phase voltages (two of three indicator lamps for phase are displayed alternately). Mains voltage V N (V Phase ). Mains voltage V N (V Phase ). Mains voltage V N (V Phase ). Mains voltage. Average of the phase voltages (the three indicator lamps for phase are displayed alternately). Rated mains frequency. Generator voltage V (V Line ). Generator voltage V (V Line ). Display 04 0 0 0 00 09 08 07 06 05 04 OPM 60 en-gb 8 Scania CV AB 0, Sweden

Display Parameter Generator voltage V (V Line ). Generator voltage. Average of phase to phase voltages (two of three indicator lamps for phase are displayed alternately). Generator voltage V N (V Phase ). Generator voltage V N (V Phase ). Generator voltage V N (V Phase ). Generator voltage. Average of the phase voltages (the three indicator lamps for phase are displayed alternately). Rated generator frequency. Engine running time counter in hours (six digit display with one decimal). Hour counter to next inspection (a negative value indicates that the service due date has been passed). Counter for the number of times the generator has been connected. Battery voltage Display 045 044 04 04 04 040 09 08 07 06 05 If switch is pressed again the display returns to the basic value. The display automatically returns to the basic value after 80 seconds if no switch is pressed. OPM 60 en-gb 9 Scania CV AB 0, Sweden

Display Alarm Alarm Alarm class Display 0 Generator overfrequency. F Shutdown. Generator underfrequency. F Shutdown. Generator overvoltage. F Shutdown. Generator undervoltage. F Shutdown. 4 Incorrect phase rotation. B Alarm. 0 Engine start failure. F Shutdown. Unintentional stop. F Shutdown. 40 Time for inspection. B Alarm. 05 05 05 050 049 048 047 046 5 Incorrect closing of the circuit breaker in the generator set. B Alarm. 054 5 Incorrect opening of the circuit breaker in the generator set. B Alarm. 04 5 Incorrect closing of the circuit breaker in the automatic transfer switch. B Alarm. 04 54 Incorrect opening of the circuit breaker in the automatic transfer switch. B Alarm. 044 OPM 60 en-gb 0 Scania CV AB 0, Sweden

Testing the instrument panel Configuration mode To go into configuration mode press switches and at the same time. The following parameters are displayed: 00 Password 0 Time to alarm signal reset 7 Display level. To display the other parameters, enter the password for parameter 00 Password (000). Press switch to scroll down among the parameters that can be changed. Press switch 7 to increase the value of the selected parameter or press switch 8 to decrease the value. Testing the instrument panel Test with load. Press switch to put the instrument panel in manual operating mode.. Press switch 5 to start the generator set engine.. When the frequency and voltage are within limits and indicator lamps and have switched from flashing to steadily lit, the circuit breaker in the automatic transfer switch can be opened and the circuit breaker in the generator set closed by pressing switch 4. This puts a load on the generator. 4. When the test with load is completed: return the load to the electrical power network by opening the circuit breaker in the generator set and closing the circuit breaker in the automatic transfer switch. Stop the generator set by pressing switch. This completes the test with load procedure and puts the instrument panel into automatic operating mode, in stand-by to detect a power failure in the electrical power network. Test without load. Press switch to put the instrument panel in manual operating mode.. Press switch 5 to start the generator set engine.. When the test without load is completed, stop the generator set by pressing switch. This completes the test without load procedure and puts the instrument panel into automatic operating mode, in stand-by to detect a power failure in the electrical power network. OPM 60 en-gb Scania CV AB 0, Sweden

Components in the central electric unit Components in the central electric unit The illustration below shows the location of the components inside the central electric unit. 4 5 6 7 8 9 0 4 5 6 7 8 9 0 40 59 Pos. Designation Description ATSc Instrument panel for an automatic transfer switch -4 F6-F4 Miniature circuit breakers for detecting mains voltage 5 F8 Miniature circuit breaker for network supply of -way power supply 6 F7 Miniature circuit breaker for external power supply 7 F9 Miniature circuit breaker for voltage supply from generator set to -way power supply 8-0 F-F Miniature circuit breakers for detecting voltage from generator set -way power supply Direct current power supply GR Relay for supply from generator set 4 GAR Relay for supply of external voltage to generator set 5 MAR Relay for supply of external voltage 6 RSR Relay for remote start 7 RSR Relay for remote start 8 MCRC Circuit breaker closes 9 MCRO Circuit breaker opens 0 GCR Generator set switch closes OPM 60 en-gb Scania CV AB 0, Sweden

Components in the central electric unit Pos. Designation Description MCRAC Circuit breaker closes automatically OPM 60 en-gb Scania CV AB 0, Sweden