TECHNICAL MANUAL SOFFIO Ducted units

Similar documents
BASTONE (dual) fancoil Units

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

CENTRIFUGAL FAN COIL UNIT VCE

Maestro. High Pressure Fan Coil Unit with Asynchronous Motor

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY. 1.5 kw kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

BRIZA 22 HYBRID HEATING & COOLING

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

AHN 064 to 304 EHN/CHN 064 to 304

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

Accessories. Series REC

D M S 760 C01 A A 1 1

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

Highline 260i EC Waterside Fan Coil Unit

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

UMXCA/UMXCBA ECVA/ECVBA

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

ARW DRY COOLERS AXIAL FANS VERSION, MEDIUM AND HIGH CAPACITY. CAPACITY FROM 20 TO 775 kw ARW DRY COOLERS

Fan coil units MAJOR 2 CV/CH

FS Fan-Coil Units Hi-Rise, Vertical

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Carisma The Ultra Quiet Fan Coil

Fan Coil Units. Technical Data. Flexi type unit ECDEN FWD-AT/AF

The World Leading Air-conditioning Company

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

KLIMA Active Chilled Beams

ED.X Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS. COOLING CAPACITY FROM 6,7 TO 138 kw. ED.X 331 U Kc

Prepared By : Checked By : Approved By : Page 1 out of 6

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

Total cooling capacity kw Total heating capacity kw Features

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

ACOUSTIC CABINET FANS CVB / CVT Series

something new in the air Technical Bulletin

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

BAC / BHC Product Specifications

technical catalogue tetris KW Chiller and heat pumps air/water

CHP

Typical Applications. Horizontal Installation

CHILLED WATER FAN-COIL UNITS

PHCD-Series. Catalog

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation. Low Energy Consumption

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

YFCN Fan Coil Unit centrifugal fan 2 & 4 pipe system A complete range from 1.0 kw to 7.6 kw

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

CATÁLOGO TÉCNICO COMERCIAL

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

SECTION AIR TERMINAL UNITS

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

Technical Sales Guide # 040 YDFC 0 1 Page 2

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

Fan coil unit NBS 100/150

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans.

Corp L3 Revised CB17/CBH17 SERIES UNITS SPECIFICATIONS CB17-95V CBH17-95V

AQWL/AQWH/AQWR 1404 to 2406

Air Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes

Air-Cooled Liquid Chiller with integrated hydraulic module

Address: VTS Clima L.L.C.

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

SysCoil 2. Fan Coil Units Models SVC, SVN, SHC, SHN to 8.75kW to 4.90kW. 94 to /h

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

Submittal. Front View Side View

Transcription:

TECHNICAL MANUAL SOFFIO Ducted units Page 1

INDEX 1-INTRODUCTION... 4 2-OPERATING LIMITS... 4 3- KEY TO READING CODES... 5 4-TECHNICAL SPECS... 6 5-TECHNICAL DATA (AC motors)... 7 5.1-Unit 2 pipes with 3 row coil... 7 5.2-Unit 4 pipes with 3 row coil + 1 row auxiliary coil... 8 6-TECHNICAL DATA OF OPTIONAL COILS (AC motors)... 9 6.1-Optional main coils... 9 6.2-Optional auxiliary coils... 9 6.3-Direct expansion coils... 10 6.4-Coils for district-cooling... 10 9- DIMENSIONS AND WEIGHTS... 11 9.1-Dimensions and weights for horizontal version... 11 9.2- Dimensions and weights for vertical version VC... 13 9.3-Dimensions and weights for vertical version VD... 15 9.4-Hydraulic connections and volume of coils... 17 10-ACCESSORIES... 17 10.1-Valves... 20 10.2-Condensation drainage pump... 23 10.3-Electric heater... 23 10.4-Flat flange (FP)... 24 10.5-Inlet flange (FRA)... 24 10.6-Inlet flange (FRAL)... 25 10.7-Inlet flange for vertical version (FRAV)... 26 10.8-Outlet grill (GM2) and inlet grill (GR)... 26 10.9-Decorative inlet grill (GRD)... 27 10.10-Plenum 90 (P90)... 27 10.11-External air mixture suction plenum (PMA)... 28 10.12-Straight Plenum (PD)... 29 10.13-Plenum with outlet grill (PGM2)... 29 Page 2

10.14-Plenum with inlet grill (PGR)... 30 10.15-Plenum with spigot (PS)... 31 10.16-Plenum for air regulation (PRA)... 31 10.17-Plenum with post-heating coil with 3 or 4 rows (PB3 PB4)... 32 10.18-Silenced plenum (SL)... 33 10.19-Free air application unit (BL)... 34 10.20-Bag filter plenum (FRAF6, FRAF7, FRAF8)... 34 11-Electrical connections... 36 Page 3

1-INTRODUCTION The SOFFIO Series is designed for the air-conditioning systems in residential and commercial application, for indoor installations, not to expose to low or high extreme temperatures, dust-free and non-explosive environment. The manufacturer is not responsible in case of incorrect use. The units are designed to be ducted. To install without ducts can produce malfunctioning or damage of the unit. 2-OPERATING LIMITS Power supply 230 240V/50Hz 240V/60Hz (1) Inlet water temperature 3 90 C Maximum temperature air outlet (2) 50 C Temperature of air inlet 10 50 C (1) +/-6% of margin on the voltage. All the technical data given in this manual refer to 230V / 50Hz. (2) In case of water with outlet temperature higher than 50 C, please verify the temperature of the air outlet with selection software TESI10 Minimal counter pressure (motor range) 50Hz 0Pa 0 Pa 0 Pa 0 Pa 0 Pa 60Hz 0 Pa 0 Pa 0 Pa 40 Pa 0 Pa The working with low external counter pressure, even if inside the motor range, may cause the separation of drops from the coil during summer operation (to be evaluated also according to the degree of humidity). To avoid this possibility, you should work with at least 40Pa of pressure and not more of the following air flow: Maximum air flow MODEL 21 31-38 41-81 CAPACITY 1250 mc/h 2300 mc/h 4500 mc/h We suggest to let the unit work to the extremes of these operating limits only for short periods, because the operation for a long period of time may reduce the normal duration of the components. Page 4

3- KEY TO READING CODES The standard version is horizontal, single panel, 3 row coils, three-speed AC motor, right hydraulic connections. All other versions are optional. Page 5

4-TECHNICAL SPECS STRUCTURE: made of galvanized steel, thickness 1.00 1, 50 mm. The sturdy structure prevents vibrations and includes the mounting brackets to the ceiling. On request, it can be painted. ACCESSIBILITY: the filter can be removed both from the bottom and the sides, without the aid of tools (if some accessories are installed on the suction side, please refer to the specific chapter of this manual for more information). Accessibility to internal components is guaranteed by removing the bottom panel. The plate of the fan deck can be removed without disconnecting the ducts and the operation can take place from below, without the need to intervene on the sides or front of the unit. FILTER: class G3 (EN779), thickness 15 mm, synthetic fiber. Other types upon request. FAN DECK (AC motors): the fans are forward curved blades, double suction centrifugal fan, directly coupled to the motor. The cochlea is made of galvanized steel, the fan in aluminum. The motor and the fans are balanced on the plate of the fan deck after their assembly. The motor is mounted on rubber anti-vibration supports, protection level IP20, 3 speeds. FAN DECK (EC motors): the fans have forward curved blades, double suction centrifugal fan, directly coupled to the motor. The cochlea is made of galvanized steel, the fan in aluminum (size 21-31) or in plastic (size 38-41-81). The motor and the fans are balanced on the plate of the fan deck after their assembly. The motor is mounted on rubber anti-vibration supports, protection level IP20, control signal 0-10V. COIL: made with copper tube 3/8" diameter and corrugated aluminum fins with high efficiency, with manual air purge valve at the top of the collector. The standard connections are right (looking in front of the air flow). Left on request. Nominal pressure PN10. The direct expansion coils (optional) are made with copper tube 5/16 "diameter and they are suitable to work with refrigerant R410A (up to 45bar). Other refrigerants on request. CONDENSATION DRAIN PAN: made of galvanized steel and painted to prevent rust. The drainage pipe and the edges are welded to avoid losses even after a long time. The drain pan is externally insulated with thermal insulation and it is mounted with slope towards the drain pipe to avoid water stagnations. INSULATION: made of polyurethane with thickness 10 mm, HF1 class according to the rule UL94 (flame retardant and not dripping). The thermo-acoustic insulation is protected against moisture and dust thanks to a surface film. ELECTRICAL PANEL: made in galvanized steel or plastic, it is positioned on the opposite side to hydraulic connections. On request it can be made with a watertight box in plastic and it can be placed on the same side of the hydraulic connections. Page 6

5-TECHNICAL DATA (AC motors) 5.1-Unit 2 pipes with 3 row coil EUROVENT certification not needed (*) Speed (E) min med max min med max min med max min med max min med max Air flow (E) mc/h 508 752 880 1374 1555 1630 1619 1854 2009 2326 2722 3071 2980 3516 4037 Pressure (E) Pa 23 50 68 40 50 56 38 50 59 37 50 64 35 50 67 COOLING air 27 C b.s., 19 C b.u. water inlet 7 C, outlet 12 C Total rating (E) kw 2.74 3.63 4.06 6.78 7.38 7.62 7.6 8.31 8.76 12.05 13.42 14.62 14.27 16.06 17.62 Sensible rating (E) kw 1.96 2.59 2.87 4.74 5.16 5.32 5.29 5.8 6.14 8.45 9.4 10.21 9.97 11.09 12.25 Water flow l/h 470 623 697 1163 1266 1307 1303 1425 1503 2067 2302 2509 2449 2756 3024 Δp water (E) kpa 8 13.5 16.6 14.4 16.8 17.8 17.7 20.9 23.1 11.2 13.7 16 15.3 19 22.5 HEATING air 20 C water inlet 50 C, same water flow of cooling Rating (E) kw 3.6 4.83 5.41 8.91 9.75 10.06 10.02 10.8 11.65 15.74 17.65 19.28 18.85 21.22 23.38 Water flow l/h 470 623 697 1163 1266 1307 1303 1397 1503 2067 2302 2509 2449 2756 3024 Δp water (E) kpa 6.9 11.7 14.4 12.3 14.3 15.2 15.1 17.2 19.7 9.5 11.5 13.5 12.9 16 19 ELECTRICAL POWER CONSUMPTION Power W 70 129 150 168 191 225 233 258 303 402 486 549 620 814 914 consumption (E) Max current A 0.8 1.3 1.6 2.5 4.5 SOUND DATA Sound power db(a) 51 60 65 64 68 69 65 67 70 65 68 70 70 74 77 suction+radial (E) Sound power outlet db(a) 50 59 64 63 67 68 64 66 69 64 67 69 69 73 76 (E) Sound pressure db(a) 42 51 56 55 59 60 56 58 61 56 59 61 61 65 68 suction+radial Sound pressure outlet db(a) 41 50 55 54 58 59 55 57 60 55 58 60 60 64 67 (E)= performances EUROVENT certified (*)= size 81 has no need to be EUROVENT certified Page 7

5.2-Unit 4 pipes with 3 row coil + 1 row auxiliary coil EUROVENT certification not needed (*) Speed (E) min med max min med max min med max min med max min med max Air flow (E) mc/h 500 734 856 1344 1506 1582 1573 1798 1939 2312 2695 3033 2946 3453 3989 Pressure (E) Pa 23 50 67 40 50 55 38 50 58 37 50 64 36 50 67 COOLING air 27 C b.s., 19 C b.u. water inlet 7 C, outlet 12 C Total rating (E) kw 2.7 3.58 3.99 6.68 7.2 7.47 7.45 8.14 8.59 11.97 13.34 14.52 14.23 15.85 17.38 Sensible rating (E) kw 1.94 2.54 2.8 4.66 5.02 5.2 5.19 5.66 5.96 8.4 9.32 10.11 9.85 11.01 12.19 Water flow l/h 463 614 684 1146 1236 1282 1278 1397 1474 2054 2289 2491 2441 2720 2982 Δp water (E) kpa 7.8 13.1 16 14 16.1 17.2 17.1 20.2 22.2 11.1 13.5 15.8 15.2 18.5 21.9 HEATING - air 20 C - water inlet 70 C, outlet 60 C Rating (E) kw 2.99 3.81 4.22 7.06 7.62 7.8 7.76 8.4 8.81 13.05 14.34 15.35 15.1 16.58 17.99 Water flow l/h 262 335 371 620 669 685 681 738 774 1146 1260 1348 1326 1456 1580 Δp water (E) kpa 2.6 4.1 4.9 5.6 6.5 6.8 6.7 7.8 8.5 6.5 7.8 8.9 8.6 10.2 11.9 ELECTRICAL POWER CONSUMPTION Power W 70 129 150 168 191 225 233 258 303 402 486 549 620 814 914 consumption (E) Max current A 0.8 1.3 1.6 2.5 4.5 SOUND DATA Sound power db(a) 51 60 65 64 68 69 65 67 70 65 68 70 70 74 77 suction+radial (E) Sound power outlet db(a) 50 59 64 63 67 68 64 66 69 64 67 69 69 73 76 (E) Sound pressure db(a) 42 51 56 55 59 60 56 58 61 56 59 61 61 65 68 suction+radial Sound pressure outlet db(a) 41 50 55 54 58 59 55 57 60 55 58 60 60 64 67 (E)= performances EUROVENT certified (*)= size 81 not need EUROVENT certification Page 8

6-TECHNICAL DATA OF OPTIONAL COILS (AC motors) 6.1-Optional main coils Speed min med max min med max min med max min med max min med max 4 ROW COIL COOLING air 27 C b.s., 19 C b.u. water inlet 7 C, outlet 12 C Total rating kw 3.1 4.2 4.8 7.8 8.6 8.9 8.8 9.8 10.3 13.7 15.5 17.0 16.6 18.7 20.8 Sensible rating kw 2.3 3.0 3.4 5.6 6.1 6.3 6.3 6.9 7.3 9.8 11.1 12.0 11.8 13.3 14.7 Water flow l/h 533 727 816 1340 1469 1523 1516 1674 1776 2354 2660 2922 2846 3217 3562 Δp water kpa 5.9 10.5 13 10.1 11.9 12.7 12.6 15.2 16.9 7.7 9.6 11.4 10.9 13.6 16.4 HEATING air 20 C water inlet 50 C, same water flow of cooling Rating kw 4.1 5.6 6.3 10.2 11.2 11.6 11.6 12.8 13.6 17.8 20.2 22.2 21.7 24.6 27.3 Water flow l/h 533 727 816 1340 1469 1523 1516 1674 1776 2354 2660 2922 2846 3217 3562 Δp water kpa 5.1 9.1 11.3 8.6 10.1 10.8 10.7 12.9 14.4 6.5 8.1 9.6 9.2 11.5 13.8 6 ROW COIL COOLING air 27 C b.s., 19 C b.u. - water inlet 7 C, outlet 12 C Total rating kw 3.7 5.1 5.9 9.7 10.7 11.1 11.1 12.3 13.2 17.2 19.6 21.7 21.1 24.1 26.9 Sensible rating kw 2.7 3.7 4.2 6.8 7.5 7.8 7.8 8.7 9.2 12.0 13.6 15.0 14.7 16.7 18.6 Water flow l/h 642 882 1009 1659 1836 1912 1903 2119 2265 2946 3365 3722 3624 4140 4616 Δp water kpa 6.4 11.5 14.8 15 18 19.4 19.2 23.4 26.5 16.5 21 25.3 24.1 30.6 37.3 HEATING air 20 C - water inlet 50 C, same water flow of cooling Rating kw 4.6 6.5 7.4 11.9 13.2 13.8 13.7 15.3 16.4 20.7 23.7 26.3 25.7 29.5 33.1 Water flow l/h 642 882 1009 1659 1836 1912 1903 2119 2265 2946 3365 3722 3624 4140 4616 Δp water kpa 5.5 9.9 12.8 12.6 15.2 16.4 16.3 19.8 22.4 13.8 17.5 21.1 20.1 25.6 31.2 6.2-Optional auxiliary coils Speed min med max min med max min med max min med max min med max ADDITIONAL 2 ROW COIL (4 PIPES) HEATING - air 20 C - water inlet 70 C, outlet 60 C Rating kw 4.9 6.3 7.0 11.6 12.5 12.9 12.9 14.1 14.8 21.0 23.3 25.2 24.7 27.4 30.1 Water flow l/h 428 553 615 1019 1098 1136 1134 1240 1304 1845 2043 2213 2166 2411 2648 Δp water kpa 3.9 6.2 7.6 6.7 7.7 8.2 8.2 9.7 10.7 4.4 5.3 6.1 5.9 7.2 8.6 Page 9

6.3-Direct expansion coils Speed min med max min med max min med max min med max min med max 4 ROW DIRECT EXPANSION COIL COOLING air 27 C b.s., 19 C b.u. R410A evaporation 5 C Total rating kw 4.3 5.9 6.7 10.6 11.7 12.2 12.1 13.4 14.2 19.2 21.8 24.0 23.4 26.6 29.5 Sensible rating kw 2.9 4.0 4.6 7.3 8.1 8.4 8.4 9.3 10.0 12.9 14.8 16.3 15.9 18.3 20.5 COOLING air 27 C b.s., 19 C b.u. R410A evaporation 7 C Total rating kw 3.7 5.0 5.6 8.9 9.8 10.2 10.2 11.3 12.0 16.2 18.4 20.3 19.8 22.5 25.1 Sensible rating kw 2.6 3.6 4.2 6.5 7.3 7.6 7.5 8.5 9.1 11.6 13.3 14.8 14.4 16.6 18.6 COOLING air 27 C b.s., 19 C b.u. R410A evaporation 10 C Total rating kw 2.8 3.7 4.2 6.7 7.2 7.5 7.4 8.1 8.5 12.2 13.6 14.8 14.5 16.2 17.7 Sensible rating kw 2.2 3.1 3.6 5.7 6.3 6.5 6.5 7.3 7.8 10.0 11.4 12.6 12.3 14.1 15.9 HEATING - air 20 C R410A condensation 40 C Total rating kw 2.7 3.6 4.0 6.4 7.0 7.3 7.2 8.0 8.4 11.8 13.2 14.5 14.1 15.9 17.6 HEATING - air 20 C R410A condensation 45 C Total rating kw 3.5 4.7 5.3 8.4 9.2 9.5 9.5 10.5 11.1 15.4 17.3 18.9 18.5 20.9 23.1 HEATING - air 20 C R410A condensation 50 C Total rating kw 4.4 5.9 6.6 10.5 11.5 11.9 11.8 13.1 13.8 19.1 21.5 23.6 23.0 26.0 28.8 6.4-Coils for district-cooling Speed min med max min med max min med max min med max min med max 4 ROW COIL COOLING air 24 C b.s., 18 C b.u. water inlet 5,5 C, outlet 14,5 C Total rating kw 2.0 3.1 3.6 6.6 7.2 7.4 7.4 8.1 8.6 12.0 13.5 14.7 14.3 16.2 17.7 Sensible rating kw 1.6 2.2 2.5 4.2 4.6 4.8 4.8 5.2 5.5 7.7 8.5 9.3 9.1 10.2 11.2 Water flow l/h 186 300 342 626 685 707 705 776 817 1145 1288 1399 1369 1542 1690 Δp water kpa 1.8 4.4 5.6 11.9 14 14.9 14.8 17.6 19.4 13.6 16.8 19.5 18.7 23.2 27.4 6 ROW COIL COOLING air 24 C b.s., 18 C b.u. - water inlet 5,5 C, outlet 14,5 C Total rating kw 3.2 4.5 5.1 8.4 9.3 9.6 9.6 10.6 11.2 15.0 17.0 18.7 18.3 20.7 23.0 Sensible rating kw 2.2 2.9 3.3 5.4 5.9 6.2 6.1 6.8 7.2 9.6 10.8 11.9 11.6 13.1 14.5 Water flow l/h 306 428 484 801 886 916 912 1010 1069 1432 1623 1782 1741 1973 2191 Δp water kpa 6.9 12.6 15.8 14.5 17.4 18.5 18.4 22.1 24.5 14.4 18 21.4 20.5 25.7 31 Page 10

9- DIMENSIONS AND WEIGHTS 9.1-Dimensions and weights for horizontal version Standard version (right connections) R.A.= air inlet M.A.= air outlet E.F.= filter extraction Optional version (left connections) 1 Main coil IN 2 Main coil OUT 3 Auxiliary coil IN 4 Auxiliary coil OUT 5 Condensate drain Page 11

A 660 1100 1100 1650 1650 M 708 1148 1148 1698 1698 B 550 550 550 650 650 N 570 1010 1010 1560 1560 C 300 300 300 375 375 O 50 50 50 60 60 D 240 240 240 300 300 P 230 230 230 275 275 E 20 20 20 25 25 Q 230 230 230 275 275 F 120 120 120 120 120 R 115 115 115 190 190 G 90 90 90 125 125 S 90 90 90 90 90 H 44 44 44 44 44 T 30 30 30 30 30 I 70 70 70 70 70 U 68 68 68 68 68 L 738 1178 1178 1728 1728 WEIGHT OF THE UNIT (kg) 3 rows 38 54 55 90 94 3 rows +1 (4 pipes) 40 57 58 94 98 3 rows +2 (4 pipes) 42 60 61 98 102 4 rows 40 57 58 94 98 4 rows +1 (4 pipes) 42 60 61 98 102 4 rows +2 (4 pipes) 44 63 64 102 106 6 rows 44 63 64 102 106 Page 12

9.2- Dimensions and weights for vertical version VC Standard version (right connections) R.A.= air inlet M.A.= air outlet E.F.= filter extraction Optional version (left connections) 1 Main coil IN 2 Main coil OUT 3 Auxiliary coil IN 4 Auxiliary coil OUT 5 Condensate drain Page 13

A 660 1100 1100 1650 1650 M 708 1148 1148 1698 1698 B 700 700 700 900 900 N 570 1010 1010 1560 1560 C 320 320 320 375 375 O 60 60 60 60 60 D 240 240 240 300 300 P 285 285 285 385 385 E 20 20 20 25 25 Q 285 285 285 385 385 F 115 115 115 115 115 R 120 120 120 181 181 F1 82 82 82 82 82 R1 69 69 69 131 131 G 222 222 222 284 284 S 175 175 175 206 206 G1 240 240 240 300 300 S1 200 200 200 231 231 H 30 30 30 73 73 T 44 44 44 44 44 H1 68 68 68 68 68 T1 94 94 94 94 94 I 128 128 128 140 140 U 184 184 184 217 217 I1 91 91 91 105 105 U1 160 160 160 193 193 L 740 1180 1180 1730 1730 WEIGHT OF THE UNIT (kg) 3 rows 40 57 58 94 98 3 rows +1 (4 pipes) 42 60 61 98 102 3 rows +2 (4 pipes) 44 63 64 102 106 4 rows 42 60 61 98 102 4 rows +1 (4 pipes) 44 63 64 102 106 4 rows +2 (4 pipes) 46 66 67 106 110 6 rows 46 66 67 106 110 Page 14

9.3-Dimensions and weights for vertical version VD Standard version (right pipe connections) R.A.= air inlet M.A.= air outlet E.F.= filter extraction Optional version (left connections) 1 Main coil IN 2 Main coil OUT 3 Auxiliary coil IN 4 Auxiliary coil OUT 5 Condensate drain Page 15

A 660 1100 1100 1650 1650 M 708 1148 1148 1698 1698 B 685 685 685 885 885 N 570 1010 1010 1560 1560 C 320 320 320 375 375 O 60 60 60 60 60 D 240 240 240 300 300 P 285 285 285 385 385 E 20 20 20 25 25 Q 285 285 285 385 385 F 115 115 115 115 115 R 120 120 120 181 181 F1 82 82 82 82 82 R1 69 69 69 131 131 G 222 222 222 284 284 S 160 160 160 191 191 G1 225 225 225 285 285 S1 185 185 185 216 216 H 30 30 30 73 73 T 44 44 44 44 44 H1 68 68 68 68 68 T1 94 94 94 94 94 I 128 128 128 140 140 U 184 184 184 217 217 I1 91 91 91 105 105 U1 160 160 160 193 193 L 740 1180 1180 1730 1730 V 30 30 30 30 30 WEIGHT OF THE UNIT (kg) 3 rows 40 57 58 94 98 3 rows +1 (4 pipes) 42 60 61 98 102 3 rows +2 (4 pipes) 44 63 64 102 106 4 rows 42 60 61 98 102 4 rows +1 (4 pipes) 44 63 64 102 106 4 rows +2 (4 pipes) 46 66 67 106 110 6 rows 46 66 67 106 110 Page 16

9.4-Hydraulic connections and volume of coils HYDRAULIC CONNECTIONS 1 Main coil IN 3/4" 3/4" 3/4" 1" 1" 2 Main coil OUT 3/4" 3/4" 3/4" 1" 1" 3 Auxiliary coil IN 3/4" 3/4" 3/4" 3/4" 3/4" 4 Auxiliary coil OUT 3/4" 3/4" 3/4" 3/4" 3/4" 5 Condensate drain pipe 20mm 20mm 20mm 20mm 20mm Direct expansion-liquid pipe R410A d.6 d.10 d.10 d.16 d.16 (to weld) Direct expansion-gas pipe R410A (to weld) d.10 d.16 d.16 d.18 d.18 INTERNAL VOLUME OF COILS (litres) 3 rows 1,1 2,0 2,0 4,0 4,0 4 rows 1,5 2,7 2,7 5,4 5,4 6 rows 2,2 4,0 4,0 8,1 8,1 Auxiliary 1 row 0,4 0,7 0,7 1,3 1,3 Auxiliary 2 rows 0,7 1,3 1,3 2,7 2,7 4 rows/direct expansion R410A 1,0 1,8 1,8 3,6 3,6 10-ACCESSORIES HYDRAULIC ACCESSORIES O/VC/VD A/K/C V22K 2 way valve ON-OFF 230V O/VC/VD K V42K 2 way valve ON-OFF for 4 pipes O/VC/VD K V23K 3 way valve ON-OFF 230V O/VC/VD K V43K 3 way valve ON-OFF 230V for 4 pipes O/VC/VD K V22MK 2 way modulating valve 0-10V O/VC/VD K V42MK 2 way modulating valve 0-10V for 4 pipes O/VC/VD K V23MK 3 way modulating valve 0-10V O/VC/VD K V43MK 3 way modulating 0-10V for 4 pipes O/VC/VD K PSC Condensate drainage pump O/VC/VD K VCS Auxiliary drain pan for valves O K ELECTRICAL ACCESSORIES TR24 Transformator 230Vac-24Vac, 20VA for modulating valve O/VC/VD A ETBN Power relay board for SOFFIO 21-31-38-41 O/VC/VD A Page 17

ETBN-6A Power relay board for SOFFIO 81 only O/VC/VD A EH Electric heater (installed inside the unit) O/VC/VD A EHR Relay for electric heater O/VC/VD A IPB Watertight electric box, on the same side of the water connections O/VC/VD A AERAULIC ACCESSORIES FP Flat flange (inlet or outlet) O/VC/VD A FRA Inlet flange with filter extraction from the bottom O A FRAL Inlet flange with filter extraction from the side O A FRAV Inlet flange for vertical version with filter extraction from the front VC A GM2 Outlet grill with double regulation O/VC/VD B GRD Decorative inlet grill O B GR Inlet grill O/VC/VD B P90 Plenum 90 (inlet or outlet) O/VC/VD B PMA Air mixture suction plenum O/VC/VD B PD Plenum (inlet or outlet) O/VC/VD B PGM2 Plenum with outlet grill with double regulation O/VC/VD B PGR Plenum with inlet grill O B PS Plenum with spigot (inlet or outlet) O/VC/VD B PRA Plenum of air regulation O/VC/VD B PB3 Plenum with post-heating coil with 3 rows O/VC/VD B PB4 Plenum with post-heating coil with 4 rows O/VC/VD B SL Silenced plenum (inlet or outlet) O/VC/VD B BL Free ducted unit O/VC/VD A ACCESSORIES FOR THE INSTALLATION TPP Roof cover O B ZA Socle set O B FILTRATION FRAF6 Inlet flange with bag filter class F6 O B FRAF7 Inlet flange with bag filter class F7 O B FRAF9 Inlet flange with bag filter class F8 O B FA1 Washable, wire mesh filter of polypropylene class G1 thickness 6mm O/VC/VD A FA2 Synthetic fiber filter class G3 thickness 20mm O/VC/VD A FA3 Synthetic fiber filter class G4 thickness 25mm O/VC/VD A FA4 Filter of mesh of galvanized steel class G1 thickness 15mm O/VC/VD A FA5 Filter of mesh of galvanized steel class G1 thickness 25mm O/VC/VD A FA6 Aluminum mesh filter class G1 thickness 15mm O/VC/VD A FA7 Aluminum mesh filter class G1 thickness 25mm O/VC/VD A Page 18

A/K/B: A = accessory mounted on the basic unit ; K = accessory supplied in kit, not mounted; B = accessory supplied assembled, but it is not mounted on the basic unit O/VC/VD: O = accessory available for horizontal version ; VC = accessory available for vertical version VC ; VD = accessory available for vertical version VD According to the table hereafter, the accessories of the group C can be directly connected to the structure of the unit. The accessories of the group D need the accessory FP (if they are connected in outlet) or FRA+FP (if they are connected in inlet) to be connected to the structure of the unit. Furthermore the accessories of the group D can be connected in series among them. Group OUTLET INLET FP - X (next FRA) FRA C X FRAL C X FRAV C X GM2 - X (end duct) GRD C X GR - X (end duct) P90 D X (next FP) X (next FRA+FP) PMA D X (next FRA+FP) PD D X (next FP) X (next FRA+FP) Page 19

PGM2 C X PGR C X PS D X (next FP) X (next FRA+FP) PRA D X (next FRA+FP) PB3 - PB4 C X SL C X (next FP) X (next FRA+FP) FRAF6-7 - 8 C X 10.1-Valves We suggest to use motorized valves in order to avoid condensation on the surface of the unit when the fan doesn t work. The valves are supplied in kit, not mounted, to avoid damages during transport and/or installation. VALVES FOR MAIN COIL GENERAL CHARACTERISTICS Dimensions of the connections 3/4 1 1 1 1 Kv (2 way valve) 2,5 4,5 4,5 6,5 8 Kv (3 way valve, linear) 2,5 4,5 4,5 6,5 8 Kv (3 way valve, by-pass) 1,6 3,1 3,1 3,3 6,7 Max differential pressure 1,0bar 0,7bar 0,7bar 1,5bar 1,0bar Nominal pressure 16bar Water temperature 4-110 C ON/OFF ACTUATOR Power supply 230V-50Hz (24V-50Hz on request) Power adsorbed 2,5W 2,5W 2,5W 18W 18W Positioning time 180s 180s 180s 240s 240s Characteristic (valve + actuator) N.C. (Normally Closed) Protection IP44 IP44 IP44 IP20 IP20 MODULANTING ACTUATOR Power supply 24V-50Hz Power adsorbed 1,5W 1,5W 1,5W 18W 18W Positioning time 8S 8S 8S 240s 240s Control signal 0-10V Impedance of control signal 100k 100k 100k 100k 100k Protection IP43 IP43 IP43 IP42 IP42 Page 20

VALVES FOR AUXILIARY COIL GENERAL CHARACTERISTICS Dimensions of the connections 3/4 3/4 3/4 1 1 Kv (2 way valve) 2,5 2,5 2,5 6,5 6,5 Kv (3 way valves, linear) 2,5 2,5 2,5 6,5 6,5 Kv (3 way valve, by-pass) 1,6 1,6 1,6 3,3 3,3 Max differential pressure 1,0bar 1,0bar 1,0bar 1,5bar 1,5bar Nominal pressure 16bar Water temperature 4-110 C ON/OFF ACTUATOR Power supply 230V-50Hz (24V-50Hz on request) Power adsorbed 2,5W 2,5W 2,5W 18W 18W Positioning time 180s 180s 180s 240s 240s Characteristic (valve + actuator) N.C. (Normally Closed) Protection IP44 IP44 IP44 IP20 IP20 MODULANTING ACTUATOR Power supply 24V-50Hz Power adsorbed 1,5W 1,5W 1,5W 18W 18W Positioning time 8S 8S 8S 240s 240s Control signal 0-10V Impedance of control signal 100k 100k 100k 100k 100k Protection IP43 IP43 IP43 IP42 IP42 Page 21

kpa kpa AERTESI srl Pressure drop direct way diagram 100 10 Kv=2,5 Kv=4,5 Kv=6,5 Kv=8 1 100 1000 10000 l / h Pressure drop by-pass diagram 100 10 Kv=1,6 Kv=3,1 Kv=3,3 Kv=6,7 1 100 1000 10000 l / h Page 22

10.2-Condensation drainage pump The condensation drainage pump is supplied in kit, not mounted, to avoid damages during transport and/or installation. Maximum water flow Maximum suction height (A) Maximum discharge height (B) Sound pressure at 1 m Power supply Alarm switch Thermal protection Protection 30 l/h 4m 13m (8 l/h) 34dB(A) 230V 50/60Hz NC 8 (electric resistence) 250V 90 C (auto-reset) IP20 10.3-Electric heater The electric heaters are made of aluminum and they have got a safety thermostat against the overheating. They are inside the unit between the coil and the fan deck. This accessory is not compatible with the auxiliary coil and with the 6 row coil. Together with the electric heater, we suggest to use our EHR (power relay). Power Capacity 2,5 kw 4,5 kw 4,5 kw 6 kw 6 kw Power supply 230V-50Hz-single phase N step 1 1 1 1 1 Page 23

10.4-Flat flange (FP) The flat flange is necessary to connect the accessories of the group D (pls refer to the table at the beginning of the paragraph) to the outlet flange or to our FRA (inlet flange). A 278 278 278 338 338 B 240 240 240 300 300 C 570 1010 1010 1560 1560 D 608 1048 1048 1598 1598 10.5-Inlet flange (FRA) The inlet flange is necessary to duct the suction. A filter with thickness 6-15-20-25mm can stay inside it; extraction from bottom. UNIT A 300 300 300 375 375 B 240 240 240 300 300 C 570 1010 1010 1560 1560 D 660 1100 1100 1650 1650 E 75 75 75 75 75 F 45 45 45 45 45 Page 24

FILTER 10.6-Inlet flange (FRAL) The inlet flange is necessary to duct the suction. A filter with thickness 6-15-20-25mm can stay inside it; extraction only from the side. UNIT A 300 300 300 375 375 B 240 240 240 300 300 C 570 1010 1010 1560 1560 D 660 1100 1100 1650 1650 E 85 85 85 85 85 F 55 55 55 55 55 FILTER Page 25

10.7-Inlet flange for vertical version (FRAV) The inlet flange is necessary to duct the suction. A filter with thickness 6-15-20-25mm can stay inside it; front extraction only. It is available only for VD version. A 320 320 320 375 375 B 240 240 240 300 300 C 570 1010 1010 1560 1560 D 660 1100 1100 1650 1650 E 75 75 75 75 75 F 45 45 45 45 45 FILTER 10.8-Outlet grill (GM2) and inlet grill (GR) The outlet grill with double regulation and the inlet grill with fixed wings are made of aluminum. The outlet grill can regulate the flow both in horizontal and vertical direction. They have got mounting holes which can be fixed with screws: for this reason they are suitable for both wall and ceiling installation. A 570 1010 1010 1560 1560 B 240 240 240 300 300 C 602 1042 1042 1592 1592 D 272 272 272 332 332 A,B : hole nominal dimensions C,D tollerance +/-10mm Page 26

10.9-Decorative inlet grill (GRD) The decorative inlet grill is used when the installation of the unit is unducted and you want to protect or hide the filter. It is made of galvanized steel, painted on request. The filter (thickness 15mm only) is inside. You can extract it by removing the decorative grill (through knobs). FILTER 10.10-Plenum 90 (P90) The plenum 90 can be installed both in outlet and inlet. A 278 278 278 338 338 B 240 240 240 300 300 C 570 1010 1010 1560 1560 D 608 1048 1048 1598 1598 E 335 335 335 395 395 F 335 335 335 395 395 Page 27

10.11-External air mixture suction plenum (PMA) The air mixture plenum is installed in the inlet and it allows a manual regulation of air capacity and renewal (67-33%). On request, it is possible to add the electric servo-control. A 278 278 278 338 338 B 240 240 240 300 300 C 570 1010 1010 1560 1560 D 608 1148 1148 1598 1598 E 170 315 315 500 500 F 360 655 655 1020 1020 G 630 1070 1070 1620 1620 H 300 300 300 350 350 I 40 40 40 40 40 Page 28

10.12-Straight Plenum (PD) The straight plenum can be installed both in outlet and inlet. A 278 278 278 338 338 B 240 240 240 300 300 C 570 1010 1010 1560 1560 D 608 1148 1148 1598 1598 E 630 1070 1070 1620 1620 F 300 300 300 350 350 10.13-Plenum with outlet grill (PGM2) The plenum with outlet grill with double regulation is used in case you need to direct the air flow in unducted installation and non-ducted outlet. The outlet grill is in aluminum and it can adjust the flow both in horizontal and vertical directions. UNIT A 300 300 300 375 375 B 660 1100 1100 1650 1650 C 80 80 80 80 80 Page 29

10.14-Plenum with inlet grill (PGR) The plenum with inlet grill is used in case you need to protect or hide the filter in unducted installation and non-ducted inlet. The inlet grill is in aluminum and it can contain the filter with thickness 15mm. A 300 300 300 375 375 B 660 1100 1100 1650 1650 C 80 80 80 80 80 FILTER Page 30

10.15-Plenum with spigot (PS) The plenum with spigot can be installed both in outlet and in inlet; it is suitable for the connection of circular ducts. A 278 278 278 338 338 B 240 240 240 300 300 C 570 1010 1010 1560 1560 n 2 3 3 4 4 D 200 200 200 250 250 E 608 1048 1048 1598 1598 F 100 100 100 100 100 G 200 200 200 200 200 10.16-Plenum for air regulation (PRA) The plenum for air regulation is installed in suction side and it allows the regulation of the air flow with pressure drop. The dumper is manually regulated. On request, it is possible to add the electric servo-control. A 278 278 278 338 338 B 240 240 240 300 300 C 570 1010 1010 1560 1560 D 608 1148 1148 1598 1598 E 630 1070 1070 1620 1620 F 300 300 300 350 350 Page 31

10.17-Plenum with post-heating coil with 3 or 4 rows (PB3 PB4) The post-heating plenum can be used in 4 pipe systems, when the auxiliary coils with 1 or 2 rows are not enough. The pressure drop, due to the post-heating coil, must be considered in the air flow capacity of the unit. POST-HEATING COIL SOFFIO 21 Air flow mc/h 500 600 700 800 900 1000 1100 Pressure drop PB3 Pa 10 13 16 20 27 28 32 Pressure drop PB4 Pa 14 18 22 26 31 37 42 POST-HEATING COIL SOFFIO 31-38 Air flow mc/h 1000 1200 1400 1600 1800 2000 2200 Pressure drop PB3 Pa 12 15 19 23 27 32 37 Pressure drop PB4 Pa 15 20 25 30 36 42 48 POST-HEATING COL SOFFIO 41-81 Air flow mc/h 2500 2750 3000 3250 3500 3750 4000 Pressure drop PB3 Pa 16 18 21 23 26 29 32 Pressure drop PB4 Pa 21 24 27 31 34 38 42 UNIT UNIT Page 32

A 278 278 278 342 342 B 240 240 240 300 300 C 570 1010 1010 1560 1560 D 660 1100 1100 1650 1650 E 370 370 370 470 470 10.18-Silenced plenum (SL) The silenced plenum can be used both in outlet and in inlet. The internal insulation is made of self-estinguish polyurethan foam ashlared film class HF1 (self-estinguish without drop) according to UL94. Noise absorbing performances are increased with internal insulated sectors. A 278 278 278 338 338 B 240 240 240 300 300 C 570 1010 1010 1560 1560 D 608 1148 1148 1598 1598 E 630 1070 1070 1620 1620 F 750 750 750 750 750 G 550 550 550 550 550 Page 33

10.19-Free air application unit (BL) If the standard unit operates in free air, in cooling mode it is possible to have a small water dropping from the coil out of the drain pan and in heating mode a fan motor overheating. When the unit is installed with free output, we suggest to order the code BL to avoid the a.m inconveniences. The application of this tool reduces the standard air flow for about 50-70Pa of external pressure. 10.20-Bag filter plenum (FRAF6, FRAF7, FRAF8) The inlet plenum with bag filter allows the filter extraction only from the bottom. The bag filter can be of class F6-F7-F8. The standard filter is installed inside the plenum before the bag filter. The pressure drop of the bag filter must be considered in the reduction of the air flow capacity. BAG FILTER SOFFIO 21 Air flow mc/h 500 600 700 800 900 1000 1100 Pressure drop FRAF6 / F7 Pa 8 9 10 15 21 28 36 Pressure drop FRAF8 Pa 10 11 12 18 24 31 44 BAG FILTER SOFFIO 31-38 Air flow mc/h 1000 1200 1400 1600 1800 2000 2200 Pressure drop FRAF6 / F7 Pa 28 38 48 60 80 100 120 Perdita di carico FRAF8 Pa 31 43 57 75 95 117 140 BAG FILTER SOFFIO 41-81 Air flow mc/h 2500 2750 3000 3250 3500 3750 4000 Pressure drop FRAF6 / F7 Pa 40 47 54 63 75 87 100 Pressure drop FRAF8 Pa 45 55 66 78 91 102 117 Page 34

UNIT A 300 300 300 375 375 B 240 240 240 300 300 C 570 1010 1010 1560 1560 D 660 1100 1100 1650 1650 E 475 475 475 475 475 F 445 445 445 445 445 FILTER Page 35

11-Electrical connections On the basic configuration the electrical panel has got the electric box type PA104 (pls refer to the here under pattern). For other configurations and accessories, pls refer to the specific wiring diagram supplied with the unit. Mac Vc Vh AC motor Heating/cooling valve (2 pipes) Cooling valve (4 pipes) Heating valve (4 pipes only) COM Common White MAX MAX speed Black MED MED speed Blue MIN MIN speed Red ----------------------------------------------------------------------------------------------------------------------------- ------------------- AERTESI Srl Unipersonale Viale della Tecnica, 6 Conselve (PD) Italy www.aertesi.com E-mail : info@aertesi.com Phone : +39 049 9501109 Page 36