ENERGY-SAVING HYDRAULIC POWER SOURCE USING INVERTER-MOTOR DRIVE

Similar documents
Development of a Clutch Control System for a Hybrid Electric Vehicle with One Motor and Two Clutches

Friction and Vibration Characteristics of Pneumatic Cylinder

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

Dynamic Behavior Analysis of Hydraulic Power Steering Systems

Estimation of Friction Force Characteristics between Tire and Road Using Wheel Velocity and Application to Braking Control

Preliminary Study on Quantitative Analysis of Steering System Using Hardware-in-the-Loop (HIL) Simulator

Study on the Servo Drive of PM-LSM to Be Used in Parallel Synchronous Drive

Active Vibration Control of Excavator Working Equipment with ADAMS

Low Speed Control Enhancement for 3-phase AC Induction Machine by Using Voltage/ Frequency Technique

A Study on the Measurement of Contact Force of Pantograph on High Speed Train

Research on Skid Control of Small Electric Vehicle (Effect of Velocity Prediction by Observer System)

Available online at ScienceDirect. Procedia CIRP 33 (2015 )

Braking Circuit of Small Wind Turbine Using NTC Thermistors under Natural Wind Condition

A study on the vibration analysis of a maglev vehicle A theoretical investigation of the effect of magnetic damping on a vibration control system

New Capacity Modulation Algorithm for Linear Compressor

1-3 RAMP AND TORQUE BOOST EXERCISE OBJECTIVE

Autonomous Voltage and Frequency Control by Smart Inverters of Photovoltaic Generation and Electric Vehicle

ENERGY RECOVERY SYSTEM FOR EXCAVATORS WITH MOVABLE COUNTERWEIGHT

LECTURE-23: Basic concept of Hydro-Static Transmission (HST) Systems

Analysis of Torsional Vibration in Elliptical Gears

FEASIBILITY STYDY OF CHAIN DRIVE IN WATER HYDRAULIC ROTARY JOINT

Performance of DC Motor Supplied From Single Phase AC-DC Rectifier

Special edition paper

CLOSED CIRCUIT HYDROSTATIC TRANSMISSION

Speed-Control of Energy Regulation Based Variable-Speed Electrohydraulic Drive

Design and experiment of hydraulic impact loading system for mine cable bolt

Modeling and Vibration Analysis of a Drum type Washing Machine

DESIGN AND EXPERIMENTATION OF TEST RIG TO CHARACTERIZE HYDROSTATIC DRIVEFOR LINEAR ACTUATOR

The research on gearshift control strategies of a plug-in parallel hybrid electric vehicle equipped with EMT

One-Cycle Average Torque Control of Brushless DC Machine Drive Systems

EFFECTIVENESS OF THE ACTIVE PNEUMATIC SUSPENSION OF THE OPERATOR S SEAT OF THE MOBILE MACHINE IN DEPEND OF THE VIBRATION REDUCTION STRATEGIES

Study Solution of Induction Motor Dynamic Braking

Development of Higher-voltage Direct Current Power Feeding System for ICT Equipment

Speed Control of 3-Phase Squirrel Cage Induction Motor by 3-Phase AC Voltage Controller Using SPWM Technique

Theoretical and Experimental Investigation of Compression Loads in Twin Screw Compressor

EE 370L Controls Laboratory. Laboratory Exercise #E1 Motor Control

A New Device to Measure Instantaneous Swept Volume of Reciprocating Machines/Compressors

Forced vibration frequency response for a permanent magnetic planetary gear

INDUCTION motors are widely used in various industries

Tension Control Inverter

EXPERIMENTAL RESEARCH OF PROPERTIES OF HYDRAULIC DRIVE FOR VALVES OF INTERNAL COMBUSTION ENGINES

TRANSIENT PERFORMANCE OF THREE PHASE INDUCTION MACHINE USING SYNCHRONOUSLY ROTATING REFERENCE FRAME

Appendix A: Motion Control Theory

Soft Start for 3-Phase-Induction Motor

Standard Drives A & D SD Application Note

Train Group Control for Energy-Saving DC-Electric Railway Operation

Analysis and measurement of damping characteristics of linear generator

International Journal of Scientific & Engineering Research, Volume 7, Issue 6, June ISSN

CONTROL AND PERFORMANCE OF A DOUBLY-FED INDUCTION MACHINE FOR WIND TURBINE SYSTEMS

Development of Feedforward Anti-Sway Control for Highly efficient and Safety Crane Operation

Study on Electromagnetic Levitation System for Ultrathin Flexible Steel Plate Using Magnetic Field from Horizontal Direction

Driving Characteristics of Cylindrical Linear Synchronous Motor. Motor. 1. Introduction. 2. Configuration of Cylindrical Linear Synchronous 1 / 5

Test Bed 1 Energy Efficient Displacement-Controlled Hydraulic Hybrid Excavator

Wind Turbine Emulation Experiment

Figure1: Kone EcoDisc electric elevator drive [2]

Research in hydraulic brake components and operational factors influencing the hysteresis losses

Cooling Enhancement of Electric Motors

Pitch Motion Control without Braking Distance Extension considering Load Transfer for Electric Vehicles with In-Wheel Motors

A STUDY ON A SOUND OPERATED VALVE FOR A WEARABLE PNEUMATIC SYSTEM

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY

Dev Bhoomi Institute Of Technology LABORATORY Department of Electrical And Electronics Engg. Electro-mechanical Energy Conversion II

CHAPTER 4: EXPERIMENTAL WORK 4-1

Potential of Large Output Power, High Thermal Efficiency, Near-zero NOx Emission, Supercharged, Lean-burn, Hydrogen-fuelled, Direct Injection Engines

Development of Large Scale Recuperator for Gas Turbine

The development of operation system of a liquid-fueled micro gas turbine

Development of Variable Geometry Turbocharger Contributes to Improvement of Gasoline Engine Fuel Economy

Performance study of combined test rig for metro train traction

Relationship between steering torque and ease of driving with bar type steering in high speed range

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

RESEARCH OF THE DYNAMIC PRESSURE VARIATION IN HYDRAULIC SYSTEM WITH TWO PARALLEL CONNECTED DIGITAL CONTROL VALVES

Fuzzy based Adaptive Control of Antilock Braking System

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

Design of pneumatic proportional flow valve type 5/3

Pressure Ratio Effect to Warm Displacer Type Pulse Tube Refrigerator

Asian Journal on Energy and Environment ISSN Available online at

Speed Control of Induction Motor using FOC Method

Charging and Discharging Method of Lead Acid Batteries Based on Internal Voltage Control

Development of Bi-Fuel Systems for Satisfying CNG Fuel Properties

Experimental Evaluation of New Magnetic Movement Converter for Linear Oscillatory Actuator

Maneuvering Experiment of Personal Mobility Vehicle with CVT-Type Steering Mechanism

Design and Test of Transonic Compressor Rotor with Tandem Cascade

837. Dynamics of hybrid PM/EM electromagnetic valve in SI engines

Addendum to Instruction Manual GP10 and VG10

China. Keywords: Electronically controled Braking System, Proportional Relay Valve, Simulation, HIL Test

Low-torque Deep-groove Ball Bearings for Transmissions

Seismic-upgrading of Existing Stacks of Nuclear Power Station using Structural Control Oil Dampers

Mohit Law. Keywords: Machine tools, Active vibration isolation, Electro-hydraulic actuator, Design guidelines, Sensitivity analysis

Development of Novel Connection Control Method for Small Scale Solar - Wind Hybrid Power Plant

Journal of Advanced Mechanical Design, Systems, and Manufacturing

Changchun, China. 1 State Key Laboratory of Automotive Simulation and Control, Jilin University, 5988 Renmin Street

PERFORMANCE OF FUNCTION RELATIONSHIP WITH TREND BY SELECTIVE ACTUATOR

Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG)

ONLINE NON-CONTACT TORSION SENSING METHOD USING FIBER BRAGG GRATING SENSORS AND OPTICAL COUPLING METHOD. Yoha Hwang and Jong Min Lee

Application Note CTAN #234

Development of a High Efficiency Induction Motor and the Estimation of Energy Conservation Effect

Discussion of Marine Stirling Engine Systems

A Study on the Starting Characteristics of a Reciprocating Compressor for a Household Refrigerator

Performance of Low Power Wind-Driven Wound Rotor Induction Generators using Matlab

SWIRL MEASURING EQUIPMENT FOR DIRECT INJECTION DIESEL ENGINE

Proposal of an Electromagnetic Actuator for Prosthetic Knee Joints

Transcription:

ENERGY-SAVING HYDRAULIC POWER SOURCE USING INVERTER-MOTOR DRIVE Yutaka Tanaka, Kazuo Nakano* Naoyuki Yamamoto** * Research Laboratory of Precision Machinery and Electronics **Graduate School Tokyo Institute of Technology Yokohama, Japan ABSTRACT From a view point of saving energy, power losses in hydraulic systems including power sources should be minimized as small as possible. In conventional hydraulic power units, the output power is adjusted by controlling a displacement of variable displacement pump to avoid a waste of excess power. In this study, it is proposed for adjustment of the output power that rotating speeds of a fixed displacement pump is controlled by making use of a inverter-motor drive. We apply a digital control scheme to the energy-saving hydraulic system. A pressure feedback control system and an estimated pressure feedback control system are discussed and the results are experimentally verified. Experimental results demonstrate that the studied systems are effective to save energy for constant pressure power sources. KEYWORDS energy saving, electro-hydraulic servo system, fixed displacement pump, invertermotor drive, accumulator NOMENCLATURE C1, C2: coefficient of delivery flowrate f: frequency of electric AC supply [Hz] fc: inverter command frequency [Hz] ft: inverter frequency [Hz] Gc: feedback gain K1, K2, K3: coefficient of total efficiency N: rotational speed of motor [rad/s] P1: setting system pressure [MPa] ps: system pressure [MPa] qs: pump delivery flowrate [cm3/s] ql: quiescent flowrate [cm3/s] r: reference input [rad] v: load velocity [rad/s] We: supply electric power [kw] : total efficiency Č INTRODUCTION Electro-hydraulic servo systems have been widely used for automatic control applications requiring high power and rapid response. Conventional valve controlled electro-hydraulic servo systems are usually powered by a constant pressure power source shown in Fig.la, where the system pressure is controlled by a relief valve. In this type of hydraulic power units, the power losses are inevitable because of the existence of the relief flow maintaining the system pressure at a certain constant value. From a view point of saving energy, power losses in hydraulic systems including power sources should be minimized as small as possible. In conventional eneigy-saving hydraulic power units, the output power is adjusted by controlling a displacement of pump to avoid a waste of excess power. It has been well known that

a so-called pressure compensated variable displacement pump1) is used for an energysaving power source shown in Fig.lb. However this type of power sources was not suitable for electrical remote control of pump delivery flowrate adapting to the change of operating conditions so far. On the other hand, an intelligent variable displacement pump 2) equipped with a pressure sensor, a tilt angle sensor, a control actuator and an electric amplifier is recently developed, but this variable displacement pump consists of many mechanical parts in need of maintenance and is usually more expensive than a fixed displacement pump. In order to minimize power losses in a hydraulic power source, two of the authors. have proposed a new type of energy-saving power source) shown in Fig.lc. In this power source, the delivery flowrate is controlled by change of rotating speed of a fixed displacement pump instead of changing a pump displacement. The rotating speed of the fixed displacement pump is controlled so as to supply the necessary amount of oil to the servo system and to maintain the system pressure at a certain constant level without making use of a relief valve. The speed control method by the inverter-motor drive is adopted to change the speed of the induction motor which drives the fixed displacement pump. energy saving. It is also discussed that the pump pressure and flowrate are indirectly estimated by the state variables of the inverter-motor. These estimated variables are used for the digital feedback control system. INVERTER-MOTOR DRIVE Electric AC induction motors are generally used for prime movers in hydraulic power sources. AC induction motors offer the advantage of maintenance free, lower initial cost and simple structure, but it is a demerit in a sense that their speeds are determined by the frequencies of the commercial electric supply. It was formerly difficult for AC induction motors to change the speeds. Recently, a variable speeds AC motor drive can be achieved by advances in power electric devices and microprocessors. Fig.2 PWM type transistor inverter a Fig.1 Comparison of hydraulic power units b Rotational speeds of a three-phase AC induction motor are determined as follows: In a previous paper 4), the system pressure was directly measured by a sensor and fedback to the analogue controller. The inverter-motor was controlled to keep the system pressure at a constant value by the analogue controller. The present research gives a digital control scheme by using a microcomputer. Then a tentative duty cycle of the servo system is given as an example and investigated to confirm the effect of the digital control system for (1) where N is a rotational speed of motor, f is a frequency of the electric AC supply, s and p are a slip and the number of poles of the motor respectively. The speed of AC motors is nearly proportional to the frequency under the small slip conditions. Then the speed of AC motors can be controlled by varying a frequency of electric

AC supply. These variable frequencies are provided by a so-called inverter which is able to transform the frequency of electric AC supply from the standard frequency' to an arbitrary frequency. In this study, we use a pulse width modulation (PWM) type transistor inverter shown in Fig.2, which is one of the high efficient frequency converter. This transistor inverter can change the frequency of AC electric power within the range of 0 to type accumulator. Fig.4 shows static characteristics of the pump delivery flowrate in the studied hydraulic power source, where the system pressure p3 is kept at 7 MPa and the flowrate is measured by a volumetric flowmeter. It is clear that the delivery flowrate qs is nearly proportional to the inverter frequency fi. 80 Hz which corresponds to the rotational speed range 0 to 251 rad/s given by Eq.(1) in the four-poles AC motor. The advantage of the inverter drive is that the speed control of AC motors can be easily realized in low cost, high efficiency and wide speed range. EXPERIMENTAL APPARATUS An experimental hydraulic circuit used in this study is shown in Fig.3. It consists of an electro-hydraulic position control servo system and a hydraulic power source. The servo system is composed of a nozzle flapper type electro-hydraulic servo valve, an axial piston motor (geometric displacement 1.55 cm3/rad) and an inertia load (polar moment of the inertia 6.0 ~10-4 kgm2). The load position and velocity are measured by a potentiometer and a tachometer, respectively. Fig.4 Pump delivery flowrate In a transient condition, the pump can't supply the sufficient amount of oil to the servo system, because the AC induction motor has so large rotational inertia that the motor can't respond rapidly comparing with the servo system. A typical transient response of inverter-motor drive is shown in Fig.5, where h is a command frequency to the inverter, ff is an inverter frequency which corresponds to the speed of the AC motor. A rotational inertia or an output torque limits a maximum acceleration and deceleration of the AC motor to 50 rad/s2 and 84 rad/s2 respectively. Fig.3 Experimental hydraulic circuit The hydraulic power source consists of a 1.5kW squirrel-cage three-phase induction motor controlled by a 2.SkVA transistor inverter, a gear pump (geometric displacement 0.56 cm3/rad) and a bladder 1 50 Hz or 60 Hz is the standard frequency for commercial AC supply in Japan. Fig.5 Transient response of inverter drive

To avoid an imbalance of oil flow between supply in the power source and demand in the servo system., a short delivery is supplemented by the transient flow from the accumulator. The accumulator is recharged by the excess delivery of the pump during a dwell time of the servo system. Total efficiency of the hydraulic power source is defined as follows: where p, and of is a system pressure and a pump delivery flowrate respectively and We is a supply power from the electric source to the inverter. Fig.6 shows the experimental relationship between the inverter frequency fi and the total efficiency 1, where the system pressure is kept at 7 MPa. In the frequency range 10 to 20 Hz, the values of the total efficiency is markedly low. This is attributed to the inherent characteristics of the pump and the AC motor, so we must avoid to drive the AC motor continually in this frequency range. The hydraulic power source always has to supply the sufficient amount of oil which corresponds to a quiescent flow in the servo valve. From this reason, the pump is driven in the frequency range higher than 30 Hz which corresponds to the necessary flowrate for compensation of the quiescent flow. PRESSURE FEEDBACK CONTROL In the studied system, a pressure feedback control was adopted. In the previous paper 4), the authors made use of an analo- Fig.6 Total efficiency of power source gue controller to maintain the system pressure at a constant. An analogue system is, however, inconvenient for changing system parameters. On the contrary, a digital control is flexible for the change of system parameters, e.g. the setting pressure, the quiescent flow and the duty cycle of the servo system. Digital Feedback Control A schematic diagram of the pressure feedback control system used in this study is shown in Fig.7. The system pressure ps is directly measured by the pressure transducer and fedback to the microcomputer through the A/D converter. The microcomputer calculates the inverter command frequency fc in order to maintain the system pressure at a constant value. In this digital control system, one microcomputer simultaneously reads data of the system pressure and calculates both the reference input to the servo system given periodically and the command frequency to the inverter. If a cycle time of the servo system is controlled by a software, the CPU is used for a time controller over the cycle time and can't afford to calculate the inverter command frequencies in a pressure feedback control Fig.7 Schematic diagram of pressure feedback system

loop. Therefore data of the reference input to the servo system given in advance are stored in memories of the microcomputer system and periodically transferred from the memories to the servo system through the D/A converter by the interrupt signal of PTM (Programmable Timer Module). Its cycle time is given in a control register in the PTM beforehand. The PTM in place of the CPU is used for the cycle time controller of the reference input to the servo system. Fig.8 shows a block diagram of the pressure feedback control system, in which a pressure transducer (P. T.) senses the system pressure. A pressure feedback gain G, is selected to an optimal value by computer simulation tests. The reference input to the servo system is given to the control path in a sense of the feedforward control to get necessary pump speed. The extra signal for the compensation of the quiescent flow ql described in the previous section is also added to the control path. shown by the cross-hatched area in Fig. 9. Fig.9 Tentative duty cycle Fig.8 Block diagram of pressure feedback system Duty Cycle In order to illustrate energy saving of the studied system, a tentative duty cycle for the servo system shown in Fig.9 is investigated. In these figures, r is a load displacement, v is a load velocity, q is a necessary flowrate and W is a necessary power. The system pressure is kept at a constant (7MPa). The necessary power is nearly proportional to the necessary flowrate as given by Eq.(2). In a constant pressure power source using a relief valve shown in Fig.1a, a pump delivery flowrate must be greater than or equal to the maximum necessary flowrate for the servo system. Therefore the energy requirement of the servo system for one duty cycle is calculated to be 2.4kW ~20 sec=1.33 ~10-2 kwh and the energy not required by the servo system is wasted at a relief valve as Fig.10 Experimental results of pressure feedback system Results and Discussion Fig.10 shows experimental results of the transient responses of the pressure feedback control system for three duty cycles. In these figures, r is the reference input, v is the measured load velocity, fi is the inverter frequency nearly equal to the pump delivery flowrate, ps is the system pressure and We is the supplied electric power from an electric source to the inverter.

Corresponding to the magnitude of the reference input, the speed of theac motor is controlled by the inverter and the pump changes the delivery flowrate. Since the shortage of the delivery caused by the response lag of the AC motor is supplemented by the flow from the accumulator, the system pressure is almost exactly maintained within a permissible range. Even if the actuator of the servo system is at a stand still, the AC motor continues the rotation in order to recharge the accumulator until the system pressure rises up to the setting pressure. Systemenergy is measured to be 5.89x 103 kwh during one duty cycle in Fig.10. Thus the use of the inverter-motor drive increases saving energy to: where C1 and C2 are constants shown in Table 1. The total efficiency markedly varies with the change of the AC motor speed, so the total efficiency expressed as a function of the inverter frequency fi. where K1, K2 and K3 shown in Table 1 are (5) determined by the experimental results in Fig.6. The dependence of the delivery flowrate and the total efficiency characteristics on the change of system pressure can be neglected. Table 1 Parameter values for Eq.(4),(5) [%] by eliminating relief flow. PRESSURE ESTIMATION Hydraulic power sources transform electric energy into hydraulic energy, therefore system pressures may be estimated by state variables of an electric AC motor. From Eq.(2), the system pressure may be written as: From Eq.(4),(5), the system pressure pi given by Eq.(3) is rewritten as follows: (3) (6) Namely, the electric power, the pump delivery flowrate and the total efficiency must be determined by the state variables of the AC motor in order to estimate the system pressure. The electric power We can be directly measured at the electric AC supply by a watt meter or an ammeter and a voltmeter. The pump delivery flowrate qi is nearly proportional to the speed of the AC motor, i.e. the inverter frequency fi. From the experimental results in Fig.4, the pump delivery flowrate qi is approximately given by the inverter frequency fi as follows: (4) Fig.11 shows a relationship between the values of the system pressure pi, and the electric power We as a function of the inverter frequencies A. The estimated values of the pressure given by Eq.(6) agree with the output values of the pressure sensor. Then the estimated pressure can be used for the digital pressure feedback control system. A schematic diagram and a block diagram of the pressure feedback system without sensing the system pressure are shown in Fig.12 and Fig.13 respectively. The state variables of the inverter-motor, i.e. the inverter frequency and the supply electric power, are measured to estimate the system pressure. The measured electric power is delayed by a little time lag of

command frequency from being unstable, the measured inverter frequency fi is delayed by using memories as a retardation element in the microcomputer system. In the control loop, it took 150 ms to calculate Eq.(6) including many multiplications. In order to allow a high speed operation of Eq.(6), the relation between the measured state variables of the inverter-motor and the values of the system pressure are tabulated in advance on memories of the microcomputer system3). As a result, the estimated value of the pressure is obtained at every 200.t,s by referring to the table in memories of the microcomputer system. Fig.11 Plot of system pressure versus electric power Fig.13 Block diagram of estimated pressure feedback system Fig.14 Experimental results of estimated pressure feedback system the watt meter. The estimated pressure is incorrectly calculated by the delayed electric power and the undelayed inverter frequency, so the closed loop to calculate the inverter command frequency becomes unstable. To prevent the inverter Fig.14 shows typical results obtained from the experimental system. The duty cycle is the same example as the pressure feedback system shown in Fig.10. The system energy is measured to be 6.05 x 103 kwh during one duty cycle. Comparing to Fig.12 Schematic diagram of estimated pressure feedback system

the results in Fig.10, the inverter frequency changes slowly because of the time delay. CONCLUSIONS This paper describes the energy saving hydraulic power source using the invertermotor drive. The AC motor which drives the fixed displacement pump is controlled by the inverter, so that the pump delivers the necessary flowrate for the duty cycle of the servo system. The digital control scheme is applied to the pressure feedback system. In addition, the system pressure is estimated by the state variables of the AC motor. The estimated pressure feedback control system without sensing the system pressure is developed. It is experimentally clarified for the other duty cycles that the both digital control systems using the microcomputer are quite effective to save energy for the constant pressure power source. REFERENCES 1) Russell W. Henke: Understanding pressure compensated pumps, Hydraulics & Pneumatics, Vol.38, No.11, 1985, pp.80-83 2) Hiroshi Ito, Toshio Hashimoto: Hydraulic equipment to meet the needs of mechatronics age, Journal of Japan Hydraulics & Pneumatics Society, Vol.18, No.5, 1987, pp.363-369 (in Japanese) 3) Shinichi Yokota, Kazuo Nakano: On extending the intelligent potential of a cylindrical choke type instantaneous flowmeter, Preprint of 2nd International Conference on Flow Measurement London, 1988, pp.35-46 4) Kazuo Nakano, Yutaka Tanaka: Energysaving type electro-hydraulic servo system, to be published in the Journal of Fluid Control, Vol.18, 1988