TW G-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM

Similar documents
TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER SYSTEM

TW1000E-20W-70-DCA In Enclosure w/ Double Check Assembly VARIABLE SPEED BOOSTER SYSTEM

Duplex Booster System Instruction Manual

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified

TPHK Series Immersible Pump

TS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc

TPAK Series COOLANT PUMP

TS Series. MultiStage Centrifugal Pump Instruction Manual. Walrus America Inc. ISO 9001 Certified

TPHK Series Immersible Pump

DuraMACTM Booster Pumps

245 W. Roosevelt Road Building 12, Suite 83 West Chicago, IL

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

StormPro BA Series Sump Pump

StormPro BCV400 Sewage Ejector Pump

ESE Series Cast Iron Sewage Pumps

SUPER PUMP OUT SYSTEM

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Variable Speed Product Line

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

HR-20P Pneumatically Controlled Pressure Regulator

Pump Installation and Service Manual HRS Hydromatic Retractable System

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

HALLMARK INDUSTRIES INC

GRUNDFOS PRODUCT GUIDE. Hydro Solo-E. Grundfos Hydro Solo-E booster sets 60 Hz

Matala. VersiFlow Series. Instruction and Maintenance Manual

ITT. Goulds Pumps. 5GB, 7GB, 10GB, 18GB, 25GB, 33GB High Pressure Multi-Stage Booster Pump. Engineered for life. Residential Water Systems FEATURES

Wilo CO-Helix Pressure Boosting Systems. Engineering Specification

SPC-PANEL Simplex, Single Phase Pump Control Panel

AUTOMATIC SUBMERSIBLE UTILITY PUMP

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

5GB, 7GB, 10GB, 18GB, 25GB, 33GB

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Installation & Operating Manual

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

OPERATING MANUAL. centrifugal fan SAFETY PRACTICES

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

GARDEN HOSE UTILITY PUMP

SUBMERSIBLE SUMP PUMPS

Aquavar e-abii. TECHNICAL BROCHURE BAQUAeABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

Performance Specifications

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

BC Series Multi-position Air Handler Engineering and Specification Guide (Electric and Water Heat)

SUBMERSIBLE SUMP PUMPS

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

IMPORTANT SAFETY INSTRUCTIONS

Variable Speed Misting Pump Totally Enclosed Direct Drive MODEL HDE-1PH-230VFD

QUALITY MISTING PUMPS

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

Hydrovar and Packaged Hydrovar

Operators Manual. Recirculating Chiller /06/08

READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP

Level One Electric Vehicle Charging Station Wall Mount Product Guide

MH Series - Horizontal Multistage Pump OWNER'S MANUAL

ProFlo FatBoy

BoosterpaQ Hydro MPC-ED Guide Specification

Owner s Manual Pelican Whole House Iron and Manganese Filtration System

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

OWNER S MANUAL Spa & Jetted Bathtub Pump

Water Jetter Units DU JT50 / DU JT100

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

Models: C22D, C23D, C24D

Mizer Single Pump and Starter Box

Ratio Feeder DB & DD Series Injectors

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

AquaBoost. Variable Speed Constant Pressure Systems MODEL ABS

GRINNELL MODEL CB800 CIRCUIT BALANCING VALVE INSTALLATION & SETTING HANDBOOK

SERIES 1000 ELECTRIC ACTUATORS

GeyserMax-Flow Series

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Presoak & Tire/Engine Cleaner Systems (Air Pump) DU TC_A & DU PS_A

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

General Installation Instructions for Valves and Gates

Model 1100 Turbine Flow Meter

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

TECHNICAL BROCHURE B5-33GB R4 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

45HB, 70HB. High Pressure Centrifugal Booster Pump MODEL. WARNING: This is a booster pump. It has no lift capability. DO NOT RUN DRY. DO NOT DEADHEAD.

AquaBoost Packaged Systems

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

Page Number. Contents: Product Features 2. Physical Data 2. Nomenclature. 3. Blower Performance 3. Electrical Data 4. Warranty.. 6

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Owner s Manual Drill and Light Weight Portable Utility Pumps

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

DPS. The SSV Dual Pump System

JET METER INSTRUCTIONS

Transcription:

TW1000-75G-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM

The TW1000-75G-40 Flag Frame Booster System is equipped with a centrifugal pump regulated by a variable frequency drive that controls the pump operation to maintain constant pressure regardless of varying demand or fluctuation in incoming pressure. This system will supply 75 GPM with a 40 PSI overboost. TW1000-75G-40 FLAG FRAME Features and Benefits: Residential & Commercial application Quiet, Compact & Powerful Variable Frequency Drive controlled pump Energy efficient operation Prewired & Factory Tested Lead-Free* (Wetted) components: Centrifugal Pump: Stainless Steel Relief valve: LF Brass or SS Pressure Gauge: Stainless Steel Transducer: Stainless Steel Check valve LF Brass or SS Fittings: LF Copper or SS *All lead-free brass shall contain <.25% Pb Technical Specifications: Pump: Gould 2MS Horse Power: 3 HP Controller: Vacon 40 - NEMA 1 Rating Flow Rate: 75 GPM Boost: 35 PSI Overboost Suction: 1 1/2 inch Discharge: 1 1/4 inch Tank: Flexcon H2P20 (20 Gal) Frame Size: 19 W x 25 H x 17 D Decibel rating: <80 db @ 3500 RPM Weight: 65 lbs (approx.) SPECIFY WHEN ORDERING 1. Discharge Pressure: PSI 2. Power: Independent circuit recommended TDH All parts shown are included in the system Actual system components may vary Some assembly required Pump performance curve Options Input Current (Amps) 208-220V/1 22.1 208-220V/3 13.4 360-480V/3 5.6 GPM

BOOSTER SYSTEM DIMENSIONS 25 17 19

Assembled Units: TOWLE WHITNEY LLC All wetted surfaces shall be lead free (<.25% Pb) in conformance with the 1/4/14 federal law Shall have a variable frequency drive (VFD) with a pressure transducer, pressure gauge, and relief valve Each system shall have a properly sized air charged pneumatic tank Pump shall be connected to a separate and independent disconnect box [supplied by others] Variable Frequency Drive (VFD) shall: GENERAL SPECIFICATIONS Shall be rated using specified power requirement, efficiency shall be 98% or better at full speed All factory preset values and/or last saved data values must remain available to the operator in the event of a complete power outage NEMA 1 rated conduit enclosure Operate to a program that protects the pump against damaging hydraulic conditions such as: - Motor overload, pump overflow surges, loss of prime due to incoming water supply interruption, hunting, overload through frequency/current optimization, hydraulic damage by restricting the pumps to operate beyond their published end of curve Automatically restart after an over-current, over-voltage, under-voltage or loss of input signal protective trip Have an operator control panel [keypad] for customization of parameters Include a feature to upload / download parameters into an external device to be used with another drive or the same drive Have a removable non-volatile memory device Be capable of accepting individual analog inputs from transducer. All transducer inputs must be wired to the variable frequency drive for continuous scan and comparison function Utilize a proportional ladder logic program - integral - derivative control function Display the following values: - Pump running/standby, pump speed in Hz, user adjustable parameters such as PID set points - Motor frequency, motor current, threshold set points for PID error, minimum operating frequency - Troubleshooting and diagnostics of faults Transducer: Shall be provided to supply all pressure signals to the variable frequency drive Shall be rated for required system pressure and shall be 4-20 ma analog Centrifugal pump: Shall have 304 stainless steel casing with impellers. Shall have a 316 stainless steel shaft sleeve and a replaceable tungsten carbide + HNBR mechanical seal Mechanical seal shall be rated to withstand pressure of up to 142 PSI Motor shall be totally enclosed fan cooled (TEFC) and manufactured in compliance with CE, RoHS and CSA Pneumatic expansion tank: Shall be rated for use with potable water with an operating pressure of a maximum 125 PSI Shall be pre-charged to a pressure of 10 PSI below system operating pressure Valves and fittings: Shall be sized appropriately to allow water velocity not exceeding 10 ft/sec, to minimize cavitation and turbulence Check valve shall be spring-loaded and silent Installation: Equipment shall be installed in accordance with applicable local building, electrical and plumbing codes Shall be installed indoors (unless otherwise specified) and protected from water spray

VACON 20 - NEMA 1 RATING

CENTRIFUGAL PUMP DIMENSIONS AND SPECIFICATIONS

PNEUMATIC EXPANSION TANK SPECIFICATIONS

CENTRIFUGAL PUMP WARRANTY Booster Pump Systems Three Year Limited Warranty This warranty applies to booster pump systems built by Towle Whitney LLC, and shall: Exist 36 months from the date of shipment. Be in effect only after installation photographs are received by Towle-Whitney LLC. Towle-Whitney LLC liability under this warranty shall be limited to the repair or replacement of any part or parts found to be defective (material or workmanship) within the warranty period. Towle-Whitney LLC shall determine whether the part needs to be returned, or field scrapped. The warranty excludes: Any water damage or consequential damage. Transducers. Pump Seals. Debris in water causing internal pump damage. Systems not installed in accordance with Installation and Maintenance Instructions. Labor, transportation, and related costs incurred by the customer. Misuse, negligence, inappropriate chemicals or additives in water. Inadequate protection from freezing. Lightning, high voltage spikes, accidents, floods, or acts of God. Re-Installation costs of repaired or replacement equipment. Re-Imbursement for the loss caused by interruption of service. This warranty applies to all states and territories of the United States and Canada only. There are no express or implied warranties, including merchantability or fitness for a particular purpose, which extend beyond those warranties described or referred to above. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages and some jurisdictions do not allow limit actions on how long implied warranties may last. Therefore, the above limitations or exclusions may not apply. This warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction.