ASSA ABLOY Universal Door Closers with Heavy Duty Spring Stop Parallel Arms

Similar documents
DC3210 Series. Multi-Sized 1 thru 6 DEEP REVEAL APPLICATION WITH M103 OPTION(615F59 CLAMP KIT) Recommended Closer Size

ASSA ABLOY Universal Door Closers

Hinge (Pull) Side Door Application DC6230 Series Multi-Sized 1 thru 6 DC6430 Series Half-Size 1 thru 6. Door Mounted DC6230 & DC6430

Series 9540 J9540. Installation Instructions Multi-Sized 1 to 6 Non-Hold Open. Regular Arm Applications. Parallel Arm Applications

Installation Instructions (07-08) CAUTION

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

DC5000 Series. Cam Action Door Closer

Installation Instructions CAUTION

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Door Closer Arms DC F95 (Non-Hold Open) Regular Arm Used with regular arm mounting (pull side) and top jamb mounting (push side)

ASSA ABLOY MPI (Infinite Hold Open Range) Support Unit Models. Multi-Point Electromechanical Overhead Concealed Closer Holder Releasing Device

TS93 PT/PTH. Surface applied door closer. Installation instructions: Push side track mount with dead stop (PT) Optional hold open (PTH)

These door closers should NOT be installed on the exposed side (weather side) of exterior doors.

TS9356 PKT 90/119. Surface applied door closer. Installation instructions: Pocket door track mount in 90 /119 pocket (Closer on wall)

DC3000 Series. Door Closers

Installation Instructions Series 78-B/FHA Hold Open

Connected To Control Box Series. Closer. Set Screw. Arm Screw. Right Hand Shown. 1/8" I.D. Air Inlet Tubing Connected To Control Box

ROFU TJ 152-A. Y ALE SECURITY GROUP 50BC Series Door Closer. 50BC Series Door Closers. Sizing Chart for Installations. Ordering Information

D O O R C L O S E R S

Door Closers. DC8000 Series

5300 Series 5300 SERIES

D o o r C l o s e r s

1 of 6. Installation Instructions. ED3200/ED3200A Series Rim Exit Device ASSA ABLOY. Plug FM362 (05/15) Inactive Case. Chassis. Inactive Case.

DC8000 Series. Door Closers

1130 Series. Door Closers. SARGENT Manufacturing Company 2004, 2007 All rights reserved

4040XPT Series Door controls

4040XP Series Door controls

Door Controls DOOR CLOSERS

5300 Series. Architectural Commercial Door Control

TS93 EMF T/PT/TDE. Surface applied door closer

1461 Series Door controls

Multi-sized cast iron closer for high use applications DOOR CLOSER CATALOG

5600 Series Power Operator Installation and Instruction Manual

Installation Instructions

Installation Instructions. Non Hold Open Models. Sized (Sizes 2,3,4,5) Weaker BC 9303BC 9304BC 9305BC. Stronger +

351 Series Door Closers Models: Finishes: BHMA BHMA Description

*24828* 1 Installation. Left Hand Shown, Right Hand Opposite. Customer Service

7100 Series. Heavy Duty Architectural Door Control

422 Series. Cam Action Door Closer

51 Series Door Closers. An ASSA ABLOY Group brand

Door Closer. DC4600 Series

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

3100 Series. Commercial Door Control

4031 Series Door controls

268, 269 & 278. Concealed Door Closers

Standard closer offers 3 installation options. - Regular (Pull side) - Top Jamb (Push side) - Parallel Arm (Push side)

7100SZ Series SafeZone Installation and Instruction Manual

5100 Series. Architectural Door Control

5300 Series. Architectural Door Control

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

51 Series Door Closers. An ASSA ABLOY Group brand

Concealed overhead closer for high-end applications DOOR CLOSERS CATALOG

9000 Series Trinity The world's most intelligent door closer

626F Exit Device Trim Installation Instructions

8000 Series Tri-Style Non Handed Door Closer

Closer with traditional styling for low to moderate traffic openings 78-B/F DOOR CLOSER CATALOG

1-3/4" MOUNTING INSTRUCTIONS: 1150 SERIES SURFACE MOUNTED 1500 LB. ELECTROMAGNETIC LOCK

JACKSON CORPORATION Series

General Information 351 Series Powerglide

78-B/F Series. Traditional Door Closers

PULL SIDE MOUNTED PUSH SIDE MOUNTED DOUBLE LEVER ARM LEVER ARM P DOUBLE LEVER ARM SINGLE LEVER ARM 4110T 4210T*

3100 Series. Commercial Door Control

High Security Closers Series

S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS

7100 Series. Heavy Duty Architectural Door Control

Series. Non Hold Open Door Closers Parallel Arm. * conditions permitting. Parts. Mark and Drill Holes. Installation Sequence.

HOW TO TELL HAND OF DOOR:

Door Closer Cycle. How to Select the Proper Closer. Things to Consider

Architectural Commercial Door Control

HIGH SECURITY CLOSERS SERIES

QUICKSHIP DELIVERS PDQ S PRIORITY Series WHEN TIME EQUALS MONEY. Architectural Door Control SUGGESTED ARCHITECTURAL SPECIFICATIONS HOW TO ORDER

*24213* 4040-SE Sentronic. 1 Voltage. 6 Adjusting Hold-Open Door Position. 7 Regulation. 2 Tracking. 8 Door Closer Cover.

1430/1431 SERIES POWERGLIDE DOOR CLOSERS

HIGH SECURITY SERIES

5200 Series

5700 Series Power Operator Stop (Push) Side Mount Installation and Instruction

PUSH SIDE M O U N T E D PULL SIDE M O U N T E D D O U B L E LEVER ARM LEVER ARM P D O U B L E LEVER ARM S I N G L E LEVER ARM

Copyright , 2018 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Series. Powerglide Door Closer

*HINGE (pull) side mount shown

Norton ABS-AMERICAN BUILDING SUPPLY, INC Series Multi-Sized Closers - Packed 6 per case

RTS88. Overhead Concealed Door Closer

D-3550 / D-3551 SERIES: DOOR CLOSERS. D-3550 / D-3551 Series. Door Closers. Trusted experts. Proven reliability. Simply STANLEY.

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual

KAWNEER 1686 EL CONCEALED EXIT DEVICE

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw.

High Security Closers Series

9540 SERIES. Cast Iron Door Closer

1500 Series Door Closers

D-1610/D-1611 SERIES: DOOR CLOSERS. D-1610/D-1611 Series. Door Closers. Trusted experts. Proven reliability. Simply STANLEY.

MOUNTING INSTRUCTIONS FOR TJ1000 SERIES INSWINGING DOORS ******READ THOROUGHLY BEFORE INSTALLING******

351 SERIES POWERGLIDE DOOR CLOSER

3010 Series. 4 Latch. Hold Open Arm Door Closers Regular Arm. Installation Sequence. Mark and Drill Holes. Parts. Sweep. Set Hold Open.

Since 1880 The American Original Architectural Series Door Closers

Power drill Center punch Wire stripper

2300 OPERATING/APPLICATION/INSTALLATION INSTRUCTIONS

*4110 HCUSH mount shown

SWING DOOR SOFT ENCLOSURE (part# 16733)

Modern. Security. Doric s range of Door Closers are compact. & Clean design

Transcription:

DC610 Series Multi-Sized 1 thru 6 DC610 Series Half-Size 1 thru 6 Installation Instructions Universal Closers with Heavy Duty Spring Stop Parallel Arms A11 - Non- Arm A1 - Arm STANDARD APPLICATION WITH DEEP REVEAL APPLICATION WITH M103 OPTION(615F59 CLAMP KIT) FLUSH PARTITION APPLICATION WITH M10 OPTION (615F60 ) IMPORTANT: An improperly installed or incorrectly adjusted door closer may cause property damage or personal injury; and will void product warranty. To avoid personal injury, DO NOT DISASSEMBLE THIS CLOSER BODY. closers must be securely fastened to a properly reinforced door and frame with fasteners provided. closers with a HOLD OPEN ARM (A1) are not permitted to be installed in fire door assemblies. and frame must be specifically templated for 85,, 95, 100, 105 or 110 door swing. Type of Installation Interior Parallel Arm ' " ' 6" 3' 0" 3' 6" ' 0" ' 6" Size of & Closer Exterior In -swinging Exterior Out -swinging ' 6" 3' 0" *3' 6" *' 0" Recommended Closer Size 1 3 5 6 **Max. Opening lbs/f 8 1 16 6 RHR TO DETERMINE HAND OF YOUR : LEFT HAND RIGHT HAND LHR *DC610 Series Recommended **NOTE: These forces are for standard templating with bearing type hinges and do not account for pressure differentials and draft. Half size closers DC610 are capable of being adjusted to next higher setting. 80-9360-6003-15 Rev. 07/1

Parallel Arm Application A11 or A1 Arm SEE CHART TO SELECT DEGREE OF OPENING AND WIDTH FOR YOUR. THEN, DETERMINE FRAME CONDITION: STANDARD & DEEP REVEAL (use Dim s. A & B) or FLUSH PARTITION (use Dim s A & C) *Dimension C is only used for Flush Partition application (Frame Template 1C). S 8 " TO 3 S 33 " TO 1 S " TO 8 Opening 615F5 NHO ARM (A11) 615F5 NHO ARM (A11) 615F56 NHO ARM (A11) 615F51 HO ARM (A1) 615F53 HO ARM (A1) 615F55 HO ARM (A1) HOLD OPEN 85 95 100 105 110 DEAD STOP 95 100 105 110 115 Dim. A 11 (79) 10-1/(67) 10 (5) 9-1/ (1) 9 (9) 8-1/ (16) 1. Templates Mark (for closer bracket) and Jamb (for arm bracket). FRAME TEMPLATE 1A (Standard Application with Bracket) For Deep use Frame Template 1B (Page 3). For Flush Partition use Frame Template 1C (Page 3). Frame s 1-7/8 " to -5/8 " (8mm to 117mm) Dim. B *Dim. C 10 (5) 10-1/8(57) 9-1/ (1) 9-5/8 () 9 (9) 9-1/8 (3) 8-1/ (16) 8-5/8 (19) 8 (03) 8-1/8 (06) 7-1/ (191) 7-5/8 (19) Dim. A Dim. B *Dim. C Dim. A Dim. B *Dim. C 13-1/8(333) 1-5/8(31) 1 (305) 11-5/8(95) 11 (79) 10-1/(67) FRAME STOP REVEAL 1-1/(311) 11-5/8(95) 11-1/8(83) 10-5/8(70) 10-1/8(57) 9-1/ (1) 7/16 (11.1) FRAME STOP TOP OF 1-(31) 11-3/(98) 11-1/(86) 10-3/(73) 10-1/(60) 9-5/8 () (50.8) 1-1/ (31.8) 15-1/8(38) 1-1/(368) 13-7/8(35) 13-1/(337) 1-3/(3) 1-1/(311) 3/ (19) -3/ (70) 1-(365) 13-3/(39) 13-1/8(333) 1-1/(318) 1-1/8(308) 11-1/(9) B TYP. (9.5) HINGE 1/ OR C L (1.7) PIVOT 1-1/(368) 13-7/8(35) 13-1/(337) 1-5/8(31) 1-1/(311) 11-5/8(95) Template is Typical for all Frame Templates 1A, 1B, and 1C MOUNTING SCREW SPECIFICATIONS ARM AND CLOSER 1/-0 oval head machine screw or 1/-1 self-drilling screw. 3/16 (.8) diameter pilot hole required for Wood Applications. CLOSER NOTES: Check hand of door, see page 1. Right Hand Application Shown Left Hand Opposite 1 (5.) Dimensions given in inches (mm). Do Not Scale Drawing. Closer must be installed in a true horizontal plane to ensure proper closer performance. }or{option M5: Sex nuts, furnished when ordered Drill thru 9/3 (7.1) Enlarge to (9.5) Dia. This Side Only ( Places) -5/16 (109.5) L 1/-0 THREAD (10) 1-1/8 (9) -3/ (70) A THICKNESS " 1- (35mm) 1-3/ " (mm) & OVER SEX NUT LENGTH L 1-9/3 " (33mm) 1-1/3 " (mm) 80-9360-6003-15 Rev. 07/1 Page

Parallel Arm Application A11 or A1 Arm FRAME TEMPLATE 1B DEEP REVEAL APPLICATION with M103 OPTION (615F59 CLAMP KIT) -3/ Frame s Over -5/8 " (117mm) B HINGE FRAME STOP (70) C L OR TYP. PIVOT (50.8) (9.5) FRAME CLAMP REVEAL 7/16 (11.1) - (111.1) -1/8 (5) 1/ (1.7) 615F59 CLAMP (TYP) 5/16 (8) SPACER CLAMP Clamps Only Clamps with Spacer FRAME FRAME TEMPLATE 1C FLUSH PARTITION APPLICATION with M10 OPTION (615F60 ) 3/ (19.1) Frame s 0 to 1/8 (0mm to 3mm) C " " 615F60 Frame 1-3/ () 1-1/ (38.1) -1/ (63.5) 1/ (1.7). Install Closer Bracket 3. Mount Closer Body to Closer Bracket 1/-1 x 1-1/ OH Self-Drilling () or 1/-0 x 3/ OHMS w/ Sex Nuts () (M5 Option) Pin Hole End Countersunk Hole End Holding Pins 1/-0 x 1/ OHMS () 80-9360-6003-15 Rev. 07/1 Page 3

Parallel Arm Application A11 or A1 Arm. Connect Arm To Closer Using hex wrench provided, close (turn clockwise) CLOSING SPEED VALVE (see page for location on closer). DO NOT OVER TIGHTEN. Open door to approximately 60 Using wrench on underside of spindle, rotate spindle approximately 135 toward hinge edge of door. Install arm on spindle at an approximate angle to door. Reopen CLOSING SPEED VALVE. Install and tighten arm washer and screw. ARM ALL ANGLES SHOWN ARE APPROXIMATE 60 135 WRENCH Rotate 135 SPINDLE SPINDLE AT REST ARM CENTERLINE SPINDLE ROTATED 135 HOLD OPEN ADJUSTMENTS - A1 ARMS ONLY On Rotate Off To Decrease To Increase 80-9360-6003-15 Rev. 07/1 Page

Spring Power Adjustment Locate spring power adjuster from Illustration below DC600 Half Size Adjustment as Desired DC600 Size 1 thru 6 Adjustment See Chart DC600 SPRING POWER ADJUSTMENT CHART All DC600 closers are factory set at an approximate Size 3. Adjust closer as necessary for door size using this chart. Readjustment may be required to suit prevailing conditions. CLOSING SPEED VALVE SPRING POWER ADJUSTER (5/16 WRENCH or SOCKET) " OPTION M71 DELAYED ACTION VALVE BACKCHECK LOCATION VALVE BACKCHECK INTENSITY VALVE (FLAT TIP SCREWDRIVER W/ 5 " (17mm) Min. Shaft Length) Interior (71) 6 (76) 3 0 (915) 3 6 (1067) Size of Exterior Exterior In Out Swing Swing 6 (76) 3 0 (915) 3 6 (1067) 6 (76) ' 0 " (119) 3 0 (915) No. of Full (360 ) Turns Clockwise of Power Adjuster 8 1 16 Date Stamp Equivalent Closer Size (Approx.) 3 5 LATCHING SPEED VALVE Power Size Stamp Latch Closing Speed De la ye Action Option M-71 d Backcheck Closing Speed Valve (3/3 Allen Wrench Provided) To adjust speed of door closing from fully open to a position " to 5 from closed, turn Closing Speed Valve CLOCKWISE to SLOW closing, COUNTER-CLOCKWISE to SPEED closing. Latching Speed Valve (3/3 Allen Wrench Provided) After closing speed has been obtained, turn latching speed valve CLOCKWISE to SLOW latching or COUNTER-CLOCKWISE to SPEED latching for last " to 5 " of door travel. NOTE: Set combination of CLOSING and LATCHING speeds to between 3 and 7 seconds Use of door by handicapped, elderly or small children, may require even greater closing time. Backcheck Location Valve (3/3 Allen Wrench Provided) Valve is closed, as shipped, from factory. To increase the degree of door opening where backcheck takes effect, turn valve counter-clockwise. VALVE CLOSED OCCURS AT 65-70 OPEN 95-100 Degrees shown are approximate Backcheck Intensity Valve Turn valve COUNTER- CLOCKWISE to reduce backcheck or CLOCKWISE to increase backcheck. (Backcheck should be set to give a soft cushioning action, not a sudden stop). Installing Cover Full Cover (Standard) Slip cover over closer. Hold tightly against closer mounting surface. Secure on each side with 6-3 x 1/ " PBHMS screws. Delayed Action Valve (3/3 Allen Wrench Provided) Turn valve CLOCKWISE to SLOW closing, COUNTER- CLOCKWISE to SPEED closing. Delayed action may be adjusted from 0 seconds to 90 seconds, depending on degree of door swing. Delay occurs at the beginning of the door closing cycle from fully open down to 70, where the closing speed valve then begins its control. Copyright 006, 01 Corbin Russwin, Inc., an Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 80-9360-6003-15 Rev. 07/1 Page 5