Special Pivots, Rescue Hardware, Lipped Strike SPECIAL PIVOTS 0519 E0519 MISC.HARDWARE For use on pocket door applications. For door weight to 270 lbs., use (3) 0519 For door weight to 360 lbs., use (4) 0519 Non-handed, full mortise Listed for fire doors on 3 hour A label, and 20 minute wood doors Needle bearings supplied standard Available in most architectural finishes including US32D 90 degree max. door swing For Power Transfer For door weight to 270 lbs., use (3) 0519 For door weight to 360 lbs., use (4) 0519 Non-handed, full mortise 90 degree max. door swing ( 8) 28ga. wires supplied standard 0923 REINFORCING PIVOT Handed (indicate when ordering) Full Surface Reinforcing Pivot for 1/8 inset doors hung on 4-1/2 pivots with 3/4 to centerline of pivot. A solution to the problems of hinge or reinforcement failure resulting in sagging doors, loose scre ws, pulled out knuckles or split w ood. Easy on-site installation for maintenance personnel For use on doors up to 300# Allows for 1/8 inset from face of door to face of frame US2G Galvanized Finish Supplied with all required fasteners. Security fasteners optional 4590 RESCUE STOP For Converting a double acting center hung door to single acting Allows door to swing open in opposite direction if a hospital or nursing home patient falls and obstructs the normal swing of the door Meets ANSI Spec A1882 Stainless steel, US32D standard Pushing in on the spring loaded stop allows emergency operation of the door. Stop automatically returns to normal position when released DIRECTION OF NORMAL SWING DOOR RESCUE STOP IN NORMAL POSITION FRAME DIRECTION OF EMERGENCY OPERATION DOOR FRAME RESCUE STOP MAY BE TEMPORARILY DEPRESSED TO ALLOW DOOR TO OPEN IN OPPOSITE DIRECTION COPYRIGHT 2009 INTERNATIONAL DOOR CLOSERS, INC.
Misc. Hardward (con t) COMBO DOUBLE LIPPED STRIKE AND RESCUE STOP For 5-3/4 and 6-3/4 frame with 1-3/4 door To be used with ABH 0127 or 0128 center hung pivot sets. Ideal for hospital or nursing home bathroom doors. Stop can be rotated into frame to allow center hung or 1/8 inset double acting doors to swing out in case of emergency. Available in US32D, US32, US3, US4, US10B. For other finishes, contact factory..093 thick material Meets ANSI A1882 Non-handed For Center Hung Doors For 1/8 Inset Door CR4550/60 CR4550/CR4591 5-3/4 x 2-3/4 CR4560/CR4592 6-3/4 x 2-3/4 CR4570/80 CR4570/CR4594 5-3/4 x 2-3/4 CR4580/CR4593 6-3/4 x 2-3/4 Custom sizes available Holdback option available (CR4550,60,70,80 only) - (handed) CR4591/92 CR4594/93 3780 UNIVERSAL COORDINATOR 3760 3 780 Universal Coordinator is for pairs of doors up to 8 wide. The long arm holds the active door open until the short arm is depressed by the inactive door. When the doors are closed, the arms are hidden by the stop-mounted aluminum case. CARRY BAR One size for all pairs of doors up to 8 wide Non-handed Stop mounted Matte black finish (USP) Meets ANSI 156.3, Type 21 requirements (when used with carry bar) Mounting brackets not required when using stop mounted hardware UL listed for use with pairs of swinging fire doors with astragal For pair of doors, where inactive door can be opened before active door US UL C Patent No. 6,250,014 Mounted on inactive door N ot for use with exposed vertical rod panic devices USP standard, plated finishes available 3751/3752 MOUNTING BRACKETS 3751 5 3752 For stop mounted hardware 3751 for Stop widths up to 2-1/2 3752 for Stop widths over 2-1/2 Ready to paint aluminum, plated finishes available 5 1920 Air Lane Drive Nashville, TN 37210 (615) 885-7060 (800) 225-6737 FAX: (615) 885-0903 1140 North Kraemer Place Anaheim, CA 92806 (714) 666-0390 (800) 544-4422 FAX: (714) 666-2215
Misc. Hardward (con t) 3790 GRAVITY COORDINATOR For use on pairs of doors to allow inactive door to close before active door UL listed for use with pairs of swinging fire doors with astragal Non-handed Stainless steel Use on pairs of doors with astragal on: UL AUTOMATIC FLUSH BOLTS US C - Active door up to 4 - Inactive door over 3 4 - Both doors over 2 10 When active door is closed the bolt automatically projects to lock inactive door. Bolt retracts when active door is opened. BHMA 4.4 TYPE 25: ANSI 156.3 UL Listed 1862P UL 1860P 1860P PAIRS FOR METAL DOORS Fits ANSI prep for Metal doors 3/4 throw with 2 vertical adjustment. Adjustment can be made without removing door from frame UL listed 3 hrs on metal door up to 4 wide and 8 high If strike is misaligned, override prevents damage to door, frame or flush bolt If single unit required, order 1860S Dust proof strikes - 1870 for floor and/or threshold, 1872 for threshold only 1862P PAIRS FOR WOOD DOORS 3/4 throw with 3/4 ver tical adjustment. Adjustment can be made without removing door from fr ame UL listed 1-1/2 hrs on wood doors up to 4 and 8 high If strike and bolt are misaligned, override prevents damage to door, frame or flush bolt If single unit required, order 1862S Dust proof strikes - 1870 for floor and/or threshold, 1872 for threshold only 1920 Air Lane Drive Nashville, TN 37210 (615) 885-7060 (800) 225-6737 FAX: (615) 885-0903 1140 North Kraemer Place Anaheim, CA 92806 (714) 666-0390 (800) 544-4422 FAX: (714) 666-2215
MANUAL FLUSH BOLTS DUST PROOF STRIKES Misc. Hardward (con t) Used to lock and unlock an inactive door when the active door is open. When the inactive door is closed, moving the lock lever up locks it and moving the lever down unlocks it. Meets FED SPEC 1049 : BHMA L14081: ANSI 156.16. UL Listed. 1855S SINGLE UNIT FOR METAL DOORS Non-handed 5/8 throw with 7/8 vertical adjustment Standard rod length is 12. Other lengths are available on request If pair is required, order 1855P Dust proof strikes - 1870 for floor and/or threshold, 1872 for threshold only Available in most architectural finishes UL listed for use on metal covered doors up to 4 wide and 10 high 1857S SINGLE UNIT UL FOR WOOD DOORS US C Same features as 1855 with the addition of a special top guide for wood doors If pair is required, order 1857P 1855S 1857S Dust proof strikes - 1870 for floor and/or threshold, 1872 for threshold only 1870 1872 1870 FOR DOORS WITHOUT THRESHOLDS 1872 FOR DOORS WITH THRESHOLDS For use with any ABH flush bolts Prevents dirt, dust and debris from clogging floor strikes BOTTOM FIRE BOLT 1858 FOR METAL DOORS 1859 FOR WOOD DOORS Eliminates the need for automatic bottom flush bolt and dust proof strike At 230 degrees F. the plug and cover melt, allowing the bolt to project locking the doors together 1811 VERTICAL ROD PROTECTOR 1813 1812 Assist in handicap conformance Use in hospitals, schools, etc. Installs with #6 x 3/4 screws directly into the door Installs on any type of wood, metal or plastic door, any thickness. Covers the latching bolt and lower portion of the vertical rod assembly Fire rated Stainless Steel, Satin Finish 1811 - for pairs of doors - 24 rod cover standard (custom lengths available) 1812 - Right hand single unit 1813 - Left hand single unit Latch bolt cover - 2 1/8 projection (2-1/16 interior clearance) Rod cover - 1 1/16 projection (1 interior clearance) 1801 APPLIED STOP 1802 SPECIAL DOOR SILENCER For use with single or double doors without stops Available in all BHMA finishes Supplied with machine & woodscrews } 24 rod cover standard (custom lengths available) For metal doors 1/4 Projection Grey Available in bags of 100 or bulk pack 1920 Air Lane Drive Nashville, TN 37210 (615) 885-7060 (800) 225-6737 FAX: (615) 885-0903 1140 North Kraemer Place Anaheim, CA 92806 (714) 666-0390 (800) 544-4422 FAX: (714) 666-2215
Misc. Hardward (con t) 1803 FLOOR STOPS 1803 2 diameter x 1-3/8 high bumper 1803 H1803 Diameter and Height as required HD1803 rod 5/8 diameter x 3 long H1803 4 diameter x 1-3/8 high bumper rod 5/8 diameter x 3 long HD1803 Bumper diameter x height as required rod 1-1/4 diameter x 18 long EHD1803 3-1/4 diameter x 2 high bumper rod 5/8 diameter x 3 long For use in high abuse areas Ideal for correctional acilities, f schools, institutions No exposed fasteners Installed with quick set cement EHD1803 1803HO FLOOR STOP & HOLDER Ideal for high abuse installations like schools, heavy doors and correctional facilities. Installed with quick set cement door is hooked to floor portion with a stainless steel hook NEW! 1804 PIPE STOP & HOLDER Heavy duty construction for use in schools, institutions and correctional facilities All stainless steel components with rubber bumper The rubber bumper on the door hits the floor portion when used as a stop Door is hooked to floor portion with stainless steel hook when used as holder Floor portion secured in cement Door portion - installed with (4) #8 x 1-1/4 screws (supplied standard), sex bolts optional Floor portion is solid 1 diameter x 1 long stainless steel rod 1920 Air Lane Drive Nashville, TN 37210 (615) 885-7060 (800) 225-6737 FAX: (615) 885-0903 1140 North Kraemer Place Anaheim, CA 92806 (714) 666-0390 (800) 544-4422 FAX: (714) 666-2215
Misc. Hardward (con t) 1805 ALL STAINLESS STEEL SERIES SURFACE BOLTS DL N1805 Custom Lengths Available All stainless steel components 1 throw 8 (N1815) 12 standard (N1825) With bracket for lock - suffix L lock by others Heavy duty for extreme conditions Made of all stainless steel, finish US32D 3/4 wide x 3/4 thick bar Unit locks automatically. To release press knob toward door while unlatching. N1805L Special lengths available on request Sex bolts available Top and bottom strikes available With bracket for lock - suffix L lock by others with double lock bracket Suffix DL Accepts lock (not provided) with 3/8 max. diametr shackle and 1-3/4 min. shackle opening height. HD1805 Custom Lengths Available Custom Lengths Available 12 (HD1825TB) and 24 (HD1835TB) standard, custom lengths available Sex bolts standard Supplied with top and bottom strikes 1880 SLIDE BOLT PADLOCK LATCH NEW! Patent Pending T-Strike ASA Strike Ideal for lockers and temporary locking situations Stainless steel assembly Non-handed reversible with built-in fail safe Fits standard 160 or 161 prep in 1-3/4 or 1-3/8 doors Standard T-strike or ASA strike available For use with 3/8 diameter padlock (not provided) Model 1884 for 2-3/4 backset (161 prep) Model 1888 for 2-3/8 backset (160 prep) 1920 Air Lane Drive Nashville, TN 37210 (615) 885-7060 (800) 225-6737 FAX: (615) 885-0903 1140 North Kraemer Place Anaheim, CA 92806 (714) 666-0390 (800) 544-4422 FAX: (714) 666-2215