EntreMatic EMSL USER S MANUAL

Similar documents
Assa Abloy: Besam Automatic Door System Slim Thermo

Max. stand-by power without accessories Use frequency 100% Max leaf width Motor Motor powered at 36V with encoder Max.

Operators for sliding doors

REVOLVING DOOR AUTOMATIC TWO-WING REVOLVING DOOR

USER INSTRUCTIONS FOR SLIDING DOORS

FORD ECOSPORT Quick Reference Guide

FORD ECOSPORT Quick Reference Guide

High performance door Albany RR300. ASSA ABLOY Entrance Systems

GARAGE DOOR OPENER OWNER S MANUAL S3/S4

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Infinity & Infinity HD

In-Head Automatic Swing Door Operator DORMA. ED 200i

High performance door Albany RR300. ASSA ABLOY Entrance Systems

Ditec Valor HS and Ditec Valor HH Automatic pedestrian doors for controlled atmosphere environments

User s Manual. Automatic Switch-Mode Battery Charger

Ditec Valor H Automatic pedestrian doors for controlled atmosphere environments

Automatic Sliding Door Retrofit Drive Assembly. Installation Manual DoorControlsUSA.com

Albany RapidRoll 3000 Series The high performance doors for external and internal applications for the manufacturing industry. Technical data sheet

HIGH SECURITY PORTALS

USERS GUIDE BODYGUARD III SMR PRESENCE SENSOR

HIGH SECURITY PORTALS

Ditec automatic pedestrian sliding doors.

SLIDING DOOR OPERATOR INSTRUCTION MANUAL

Tourniket. The all round revolving door. Door Systems

TM 50 TM 80 USER MANUAL GARAGE DOOR OPERATORS ENGLISH TM50/80 MO911/1V0 SKRW433 SKR Note the operator s serial number here:

System MINI. You want to get all advantages of a Swimming pool Enclosure but you don t want to block your wonderful outside view?

Setup and Programming Manual

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

High-performance door Albany RR500. ASSA ABLOY Entrance Systems

Instruction Manual LA-SDO1 Sectional garage door opener

RF6 / RF10 / RF18 Installation Instructions

HANDBOOK APp-RCZ_01_2010_anglais_cag_pdf_couv1 couv1 03/11/ :25:15

OPERATOR S MANUAL CUSTOMER SERVICE CHECKBOOK

Gate & Door Controller with LCD and Intelligent Technology

four - leaf revolving door

242 Overhead sectional doors

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

SAFETY

TEL: G&C Electronics CC E. T.

POLARSTART PS-3025 SH Multi-Channel Remote Starter System for AUTOMATIC Transmissions

ESA II CONTROLLER AND WIRING MANUAL

C.4.CHRONO TILT AND TURN

Automatic Swing Door Operator DFA 127 IN (Inverse) Operating instructions E

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

Albany RR1000. Mechanical Installation Manual. PN: 6410T0029 Version - Rev: 04/23/2014. ASSA ABLOY Entrance Systems

5600 Series Power Operator Installation and Instruction Manual

ELECTROMAGNETIC LOCKS

four - leaf revolving door

Tourniket. The all round revolving door. Door Systems

Sensors & Accessories for Automatic Doors

OPERATIONS MANUAL LEVER CHAIN HOIST

HÖRMANN DSA 100 DSA 100 L DSA 200 DSA 200L. page 1

Metal-Roll Door Albany RapidRoll F. ASSA ABLOY Entrance Systems

Door closers catalogue 2008

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

BODYGUARD III-C USER S GUIDE

Ultra 5.0 Manufactured By Hanil Science Industrial Co., Ltd. In Korea

GaraRoll Roller Garage Doors

OPERATING INSTRUCTIONS

Talos Revolving Doors Talos Circular Sliding Doors

Barrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind)

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

ECLIPSE Laundry Dispenser Controller

GARAGE DOOR OPERATOR USER S MANUAL

RS-230-DP. Operation Guide

IMPORTANT SAFETY RECOMMENDATIONS

Ditec VALOR Sliding doors automation (Original instructions)

contents OPERATOR Maintenance SHAFT-120 Installation and Operating Manual DoorHan, 2012

Product card User manual. KP Strong Safe

MEGA WAY LCD PAGER ALARM WITH REMOTE ENGINE STARTER. Operation Manual MEGATRONIX CHATSWORTH, CA U.S.A. MEGA 2700 OPERATE 1

Product datasheet High speed door Albany HS9010PFR. ASSA ABLOY Entrance Systems

Swish Automatic Door Operators Swish Automation In-transom operator system.

Sliding Door Operator Besam SL500 T. Installation and Service Manual Original instructions, NA

CARE-C Light Curtain Installation Instructions.

From Aquarama creativity and innovation the future takes shape

INSTALLATION and OPERATION BALL WASHER MODEL NO: BW-001N

Adaptive cruise control (ACC)

Hardware Solution for Windows

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

B12.13 SALTO 4138 FOR SLOPING HEAD WINDOWS

LP550/LP560 Installation Instructions

Skippa Mobility Scooter Owner Manual

Sliding door operator

Instrument Panel TABLE OF CONTENTS. Instrument Panel Warning Lights and Indicators Meter Cluster ODOmeter/Trip ODOmeter...

ATM Lighting sp. z o.o

SPEEDROLLER SERVICE MANUAL CE DECLARATIONS LOG BOOK USER MANUAL. Edition : May 2011

Diesel Cooker x100. Operating and Maintenance Instructions

EDR G /03

GREEN & GREEN 1000 ELECTRONIC LAVATORY FAUCET. InstallatIon and maintenance guide

A U T O M A T I C T R A N S M I S S I O N M U L T I - C H A N N E L T W O - W A Y L C D R E M O T E S T A R T E R AS-2510 TW.

C.9.CHRONO INVISI TILT AND TURN

12/24 VOLT AUTOMATIC SOLAR CHARGE CONTROLLER

Prolift SCL/Prolift HD

DTS 600/800 SECTIONAL DOOR OPERATOR INSTALLATION MANUAL. Comply to: SANS IEC NRCS Cert. no /002

Lane Keep Assist. Lane markings WARNING S01892

UltraSecure 3000 Owners Manual

ED900. Low energy operator. Customizing Features: Book 3 of 3

High speed doors. Fast logistic solutions

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

Transcription:

EntreMatic EMSL USER S MANUAL AAF238EMA FAA076D1EMEI Issued 2006-08-15

All rights in and to this material are the sole property of ASSA ABLOY Entrance Systems AB. Copying, scanning, alterations or modifications are expressly forbidden without the prior written consent of applicable company within ASSA ABLOY Entrance Systems AB. 2 Issued 2006-08-15 FAA076D1EMEI

Table of content: 1. Important information... 4 2. Introduction... 5 3. Service... 6 4. Locks... 7 4.1 Locking... 7 4.2 Unlocking... 7 5. Operation... 8 5.1 Programme selectors... 8 6. Safety... 9 6.1 Integrated safety... 9 6.2 Safety system with presence sensor... 9 6.3 Safety system with photocells... 9 6.4 Emergency escape... 10 7. Troubleshooting... 11 8. Maintenance... 12 8.1 Inspection... 12 9. Accessories... 13 FAA076D1EMEI Issued 2006-08-15 3

Important information 1.0 Important information Important notice! To avoid bodily injury, material damage and malfunction of the product, the instructions contained in this manual must be strictly observed. Note! Instructions, design, specifications and illustrations which are contained in this manual are not binding. Rights reserved for changes without previous notice. Environment This operator may be equipped with batteries containing materials which are hazardous to the environment. Remove the batteries from the operator before it is scrapped. The batteries must be disposed of safely. 4 Issued 2006-08-15 FAA076D1EMEI

Introduction 2.0 Introduction This manual contains the necessary details and instructions for the daily use of the sliding door operator, EntreMatic EMSL. The EntreMatic EMSL is designed to offer continuous use, a high degree of safety and maximum lifetime. The system is self-adjusting to the effects caused by normal variations in the weather conditions and to minor friction changes caused by e.g. dirt. FAA076D1EMEI Issued 2006-08-15 5

Service 3.0 Service When your door needs to be serviced, contact the nearest authorized EntreMatic service centre. Place for telephone number, stamp, sticker or the like. We recommend inspection of doors at least once a year. According to regulations inspection of emergency escape doors is required at least twice a year, carried out by an authorized service centre. Please check the service book. 6 Issued 2006-08-15 FAA076D1EMEI

4.0 Locks Locks 4.1 Locking 4.2 Unlocking Doors used for emergency escape in buildings such as hospitals and homes for elderly people may not be locked or put in programme selection OFF. In other buildings emergency escape doors may be locked or put in programme selection OFF after it is secured that all people has left the building. Unlock all the mechanical locks before switching on the operator. Note that more than one lock may be fitted. AAF239EMA AAB454 FAA076D1EMEI Issued 2006-08-15 7

Operation 5.0 Operation 5.1 Programme selectors The functions of the door are set with different key programme selectors. The key must always be removed on emergency escape doors after changing settings. Flush mounted PSMB-5/PS-5M Surface mounted PSMB-5/PS-5M AAF268EMA AAF269EMA Programme selector functions Off Exit Auto Auto width The door cannot be opened with inner and outer activation units. The door is locked if an electromechanical locking device has been fitted. The door can be opened with a key switch/emergency push-button (if fitted). Passage from inside only. The door is normally locked if an electromechanical locking device has been fitted. The door can only be opened with the inner activation unit and with a key switch/emergency push-button (if fitted). Two-way traffic, normal operation of the door. The door can be opened with the inner and outer activation units and with a key switch/emergency push-button (if fitted). In this setting, two-way traffic is obtained. The operator selects full or partial opening depending on the volume of traffic. The door can be opened with the inner and outer activation units and with a key switch (if fitted). With an emergency push-button the door opens fully. If the door remains partly open, or is prevented from closing, for more than 10 sec. full opening is automatically selected. If the door is closed, from full opening, for more than 10 sec. the next opening will be partial. The width of the partial opening is 75% of full opening. Open The door is permanently open. The door can be moved by hand e.g. for window cleaning. All activation units but emergency push button (if fitted) are disconnected. Reset Set the programme selector to "Auto". Insert a narrow object in the small hole on the programme selector and push. The operator makes a system test of the battery (if selected), electro-mechanical lock, watch dog relay and closed position. The operator is after closing reset and ready for normal operation. Note! The Reset is not available on the PS-5M. 8 Issued 2006-08-15 FAA076D1EMEI

6.0 Safety Safety 6.1 Integrated safety To permit a safe passage between closing doors, the doors reverse immediately if an obstruction is met. They then resume their interrupted movement at low speed to check whether the obstruction has disappeared or not. If an obstruction is met between opening doors and surrounding walls or interior fittings, the doors stop immediately, and then close after a time delay. 6.2 Safety system with presence sensor Usually the safety system incorporates a presence sensor installed above the door opening. If the presence sensor detects an object in the doorway, while the doors are closing, the doors reverse immediately. They then resume their interrupted movement as soon as the object is removed. AAE593BEM 6.3 Safety system with photocells The safety system can incorporate presence photocells in the door opening. If an object is breaking the infrared (invisible) beam between the photocell units, while the doors are closing, the doors reverse immediately. They then resume their interrupted movement as soon as the object is removed. AAF241EMA FAA076D1EMEI Issued 2006-08-15 9

Safety 6.4 Emergency escape The operator can be fitted with different emergency escape units to ensure a safe evacuation of the building. Break-out unit PSB The door leaves and the side screens are swung outwards when a defined pressure are applied to them. The break-out function can also be used to create a wide opening. From fully swung out position, the door leaves can manually be slid sideways offering the possibility to transport wide objects through the opening, or to make a shop entrance more inviting during good weather conditions. AAE619BEM Mechanical emergency unit MEU An elastic cord is used to open the door in the event of power failure. Until the power is restored the door remains open. The operator will then resume the function set by the programme selector. The emergency unit is supervised by the operator control unit, which means that the door opens and remains in this position if a proper emergency opening no longer can be achieved. Every 3.5 h the following opening impulse generates an emergency opening. If the elastic cord opens the door within the limited time the test is successful and the door resumes the function set by the programme selector. Electrical emergency unit EEU The door is opened by means of a rechargeable battery unit in the event of power failure. The door remains in this position until the power is restored. The operator will then resume the function set by the programme selector. The emergency unit is supervised by the operator control unit, which means that the door opens and remains in this position if a proper emergency opening no longer can be achieved. Every 3.5 h the following opening impulse generates an emergency opening. If there is no opening impulse within an additional half hour the operator control unit generates the opening impulse itself. If the battery opens the door within the limited time the test is successful and the door resumes the function set by the programme selector. 1 0 Issued 2006-08-15 FAA076D1EMEI

Troubleshooting 7.0 Troubleshooting What s wrong The door does not open The motor does not start The motor starts but stops during opening The door does not close The motor does not start The motor starts but stops during closing The door moves slowly Remedies Change the setting of the programme selector. Check the mains switch. If break-out unit PSB is installed, check that the door leaves and side screens are completely closed. Unlock the mechanical locks. Clean the floor guide. Check for objects jammed under the door. Change the setting of the programme selector. If presence photocells are fitted, clean the protecting covers. Check the mains switch. Clean the floor guide. Check for objects jammed under the door. Prevent traffic using the door and allow it to do a complete opening and closing cycle with low speed. Reset the operator by setting the programme selector to "Auto" and pushing a narrow object in the small hole on the programme selector. Allow the operator to control the closed position without interruption. FAA076D1EMEI Issued 2006-08-15 11

Maintenance 8.0 Maintenance The cover, doors, windows and profiles must be subjected to regular inspection and cleaning, the frequency of which is governed by the environmental conditions (at least once a year). The best way to remove dust and dirt from the EMSL is to use ordinary water and a sponge. A neutral washing-up liquid may be used. 8.1 Inspection Note! Do not expose windows, doors or profiles to alkalis. Both aluminium and glass are sensitive to alkalis. Note! Do not clean with high pressure water. Operator, programme selector and sensor may be damaged and water may enter into the profiles. Note! Do not use detergents or abrasive additives. Note! Do not scrub with materials like Scotch-brite, as this will cause mechanical damage. (1) Make sure that the glazing rubbers have not shrunk at the corners. (2) Make sure that the glazing rubbers are undamaged and straight. (3) Make sure that the draught excluders are clean and undamaged. (4) Make sure that the rubber seals are clean and undamaged. (5) Make sure that the glass is clean. (6) Make sure that the cover and profiles are clean. 6 5 2 1 AAF240EMA 3 4 1 2 Issued 2006-08-15 FAA076D1EMEI

Accessories 9.0 Accessories The sliding door operator, EntreMatic EMSL, can be equipped with the following standard or optional equipment. If you wish to upgrade your operator, or add some extra equipment, contact your EntreMatic representative. Cover Activation units Programme selector PSMB-5 and PS-5M Made in clear anodized aluminium as standard. Paint finished in RAL colours or anodizing optional. See separate manuals or installation drawings. See page 8 and separate installation drawing 1000 154. Programme selector PS-2 See separate installation drawing 1000 155. Electromechanical locking device LD LDP Manual unlocking device MOLD Micro switch kit LSK Electrical emergency unit EEU Mechanical emergency unit MEU Break-out unit PSB Interlocking Emergency opening External error indication Push button PB Double carriage wheels DCW Synchronization See separate installation drawing 1000 151. Locked without power. Locked with power. For manual unlocking of the electromechanical locking device LD. See separate installation drawing 1000 214. For indication of door and lock position. See separate installation drawing 1000 146. Used if a door is required to be opened by means of a rechargeable battery unit and remain in this position in the event of power failure (EXU-1/EXU-3 required). See page 10. Every 3.5h the following opening impulse generates an emergency opening. If there is no opening impulse within an additional half hour the operator control unit generates the opening impulse itself. If the battery opens the door within the limited time the test is successful and the door resumes the function set by the programme selector. Note! The test is never performed in programme selector setting Open or in setting Off. Used if a door is required to be opened and remain opened by means of an elastic cord in the event of power failure (see separate drawing 1000 152). Every 3.5 h the following opening impulse generates an emergency opening. If the elastic cord opens the door within the limited time the test is successful and the door resumes the function set by the programme selector. Enables the door/side screens to be broken outwards in case of emergency by applying a defined pressure. (Typical to reduce energy losses and not for security reasons) used between two operators when the first operator must close before the other one can open (EXU-1 required). (Fireman's opening) opens the door in any programme selector setting (EXU-1 required). Obtained if a lamp or a buzzer is connected to EXU-1. Used to give opening impulse to the door. See separate installation drawing 1000 215. Used for door weights over 100 kg and for narrow door leaves as anti-tilt. Used between the operators of two single sliding doors, working together in very large openings. FAA076D1EMEI Issued 2006-08-15 13