Emergency Response Trailer 14

Similar documents
REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

SUNTURA HD SOLAR TRACKER

SUNTURA SOLAR TRACKER

Professional Weather Center

INDOOR LED BAR DIGIT HOCKEY SCOREBOARD INSTRUCTION MANUAL REVISION DATE: PART#:

Users Guide for Ac-sync

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

PVI 60KW, PVI 82KW, PVI 95KW

BroadBand PowerShield. 20 AHr Battery. User Manual

Installation & Operators Manual

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Owner s Guide CA 4555

BP1204 INSTALLATION/OWNER'S MANUAL

4-SIDED BASKETBALL SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

CTFRP Series Power Supplies

HBC-20 - LED HIGH BAY

INSTALL GUIDE Dodge/RAM 5.7L HEMI

SIDE-WIND, A-FRAME TRAILER JACK. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

Extreme Duty Grapple (Rock, Skeleton, Scrap & Tine) Operation and Maintenance Manual

Mechanical Spiral Sensor

Extreme Duty Grapple (Rock, Skeleton, Scrap & Tine) Operation and Maintenance Manual

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

II DISTRIBUTION & SUBSTATION TYPE C

The Luxury of Outdoor Living

ASSEMBLY / OPERATION INSTRUCTIONS. Low Profile Motorcycle Dolly

BlinkerBeam Solar Controller

INSTALLATION/OWNERS MANUAL

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

INSTRUCTIONS TUBULAR CONTROL ARMS & COIL-OVER CONVERSION FOR AMC MUSCLE CARS: 1970 AMX JAVELIN SPIRIT, HORNET, GREMLIN, CONCORD

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

User s Manual TX MHz Powercaster TM Transmitter

Cabling for power, control, and video must be run to the installation site before the mount is installed.

ASSEMBLY / OPERATION INSTRUCTIONS. Low Profile / Stand-Up Motorcycle Dolly

Installation Power Management Unit Battery Cables and Battery Harness

Window Thermometer models / / 00423

Tissue Master. User Manual

Read this entire manual before operation begins.

Installation Guide. Marine Filter SURT023M SURT024M

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

RCL-7A. User s Guide. Battery Charging Station. Technology in Depth

Owners Manual. LifeGuard Power Lift Model # Rev. 2/1/13

Remote Vehicle Control System. Keyless Entry and Convenience System

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

FENIEX ROCKER PANEL Series MODEL # D-11971

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

CA 5054 Owner s Guide

Owner s Guide CA 5055

Read all instructions before installing and using. Installer: This manual must be delivered to the end user.

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

Congratulations on your FLI Charge purchase!

User s Manual. Item no. 2561

CAUTION 7.0 WARRANTY CONTENTS. 1.0 Overview... 2

Heliporter. Owner s Manual. H250 Series. By Paravion Technology, Inc. Copyright 2017 Paravion Technology, Inc.

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

Owner s Guide ca4054 ca4554

Thermometer models / 00831A

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

Service Guide JATCO Environmental Protection Tank Model J-7000

Wireless Thermometer model 00380

AUTO-BLiP. User Manual Lotus INTELLIGENT DOWNSHIFTS. Version 1.0

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

Fifth Wheel Power Hitch Operations Manual

Model 407SE Swivel Drawbar Eye

Power Distribution Units

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

AXS609 AXS612 AXS514 AXS SERIES. INSTALLATION/OWNER'S MANUAL Car Audio

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

Owner s Guide. ca5154

Toro Sprayer Calibration Tool

Model 123 Weld-On Adjustable Drawbar Eye

Safety Sentry Electronic Breakaway Switch

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

Model 6 Weld-On Drawbar Eye

Thermometer model 00826

AUTO-BLiP. User Manual Ford Mustang INTELLIGENT DOWNSHIFTS. Version 1.2

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

User s Manual. Complete Off-Grid Solar Kits (100 to 600 Watts) Complete Off-Grid Solar Kit Manual Revision 1.0

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.2

Owner s Guide PR1BZ PR1BZLR

Baxley Trailer Company 3300 E. Cottonwood Rd. Dothan, Al (334) Fax (334)

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

INSTALLATION & OWNER'S MANUAL

Installation Manual DIAPHRAGM WELL TANK

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

GORE TRAILER MANUFACTURING INCORPORATED 305 Gore Trailer Road Whiteville, North Carolina 28472

TK TRACK LED SCOREBOARD S.O INSTRUCTION MANUAL REVISION DATE: PART#:

Owner s Manual & Safety Instructions

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Owner s Guide. ca6154

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

Potentiometer Thrust Plate Kit (50421) Installation & Operator s Instruction Manual

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Premium Supply. Tilt Deck. Models PCK-TD PCK-PTD CTD-310-K. Operator s Manual and Installation Instructions

Premium Supply. Tilt Deck. Models PCK-TD PCK-PTD. Operator s Manual and Installation Instructions

Transcription:

Emergency Response Trailer 14 User & Genave / NRC, Inc. www.genave.com support@genave.com Copyright 2017. Genave / NRC, Inc. Tech. Publication No. 9000-0000-115 Rev 01

Warning If incorrectly used, this equipment can cause severe injury. Those who use and maintain the equipment should be trained in its proper use, warned of its dangers, and should read the manuals before attempting to set up, operate, adjust or service the equipment. Keep this manual for future reference. Important Safety Information System Planning Proper planning is the cornerstone to an effective warning system. The Federal Emergency Management Agency (FEMA) publishes the Outdoor Warning Guide CPG 1-17, which should be used in planning your system. In addition, you should recognize and understand the following items: Outdoor warnings sirens and equipment are not intended to be heard indoors. Conversely indoor devices are not intended to cover outdoor environments. All devices have specific purposes and distances that they can be considered effective. Proper placement and selection of the correct equipment is necessary to cover a desired area. Refer to the FEMA guide for placement guidelines. Training is necessary to ensure those responsible can correctly activate the system. It is also necessary that everyone understand the purpose of the warning system and the protective actions they need to take when the system is activated. Periodic tests can serve to accomplish the training for the operators, in addition to demonstrating the various signals to the public. All warning systems must have contingency plans in case equipment problems or operator errors interfere with its performance. Just as with the primary warning system, the contingency plans should be periodically tested to make sure those responsible know how to implement them and the necessary response from the public is achieved. 9000-0000-115 Revision 1 2 of 14 Genave Electronics

Important Safety Information Installation & Service Precautions Electrocution, severe personal injury and damage to equipment can occur during installation or servicing this equipment. All electrical work should be performed by, or under the supervision of an experienced electrician and in accordance with all applicable electrical, fire, building and safety codes. This equipment can start at any time from local controls, automatic timers, radio remote, commands from a computer and many other sources. The sound output can cause hearing damage, while other attached equipment can cause personal injury when they engage. Whenever working in or around the equipment you must assume it could activate at any moment, and take appropriate precautions to protect yourself and others. You should completely disable the equipment before working on or in close proximity to any part of it. You must test the system and equipment to insure it is operating correctly after the installation, as well as after any work has been performed. System Operation Training is necessary to ensure those responsible can correctly activate the system. It is also necessary that everyone understand the purpose of the siren and the protective actions they need to take when the system is activated. Periodic tests can serve to accomplish the training for the operators, in addition to demonstrating the various signals to the public. You must carefully read and completely understand all the information about the system including its abilities and its limitations. Since no warning system is infallible, you must have contingency plans for warning, in the event the primary systems do not perform as expected, for any reason. 9000-0000-115 Revision 1 3 of 14 Genave Electronics

2017, Genave/NRC, Inc. ERT-14 Hardware Phone 651-460-6616 Fax 651-460-6686 PRINTED IN USA The contents of this manual are the property of Genave/NRC, Inc. and are copyrighted. Any reproduction in whole or in part is strictly prohibited. For additional copies of this manual or software, please contact Genave/NRC, Inc. Warranty: Genave/NRC, Inc. products are warranted to be free from defects in material and workmanship for a period of ONE (1) year from the date of shipment. Genave, during this period, will repair or replace any parts, which upon our examination appear to be defective in materials or workmanship. This warranty does not apply to defects, malfunctions or breakage due to improper installation, servicing, handling or use thereof, nor to units that have been damaged by lightening or other Acts of God, excess current, reversed supply connection, nor to units that have had their serial numbers altered or removed. Equipment damaged in Acts of War, abuse, misuse, tampering, submersion or willful destruction will also void this warranty. Prior to returning equipment for warranty repair, contact the Genave Customer Service Department for an RMA number. They can be reached by using the telephone number or fax number listed above. Genave/NRC, Inc. (Genave) and its licensers offer this warranty in lieu of any and all other guarantees or warranties, either express or implied, including without limitation the implied warranties of merchantability and fitness for a particular purpose, regarding hardware or software. Genave and its licensors do not warrant, guarantee or make any representations regarding the use or the results of the use of the software or hardware in terms of its correctness, accuracy, reliability, most recent or otherwise. You assume the entire risk as to the results and performance. The exclusion of implied warranties is not permitted by some jurisdictions. The above exclusion may not apply to you. In no event will Genave, its licensors, directors, officers, employees or agents (collectively Genave s licensor) be liable to you for any consequential, incidental or indirect damages (including damages for loss of business profits, business interruption, loss of business information, and the like) arising out of the use or inability to use the software or hardware even if the Genave and/or its licensor has been advised of the possibility of such damages. Because some jurisdictions do not allow the exclusion or limitation of liability for consequential or incidental damages, the above limitations may not apply to you. Genave and its licensors liability to you for actual damages from any cause whatsoever, and regardless of the form of the action (whether in contract, tort, (including negligence), product liability or otherwise), are expressly excluded. Genave reserves the right to make changes in specifications at any time and without notice. The information furnished by Genave is believed to be accurate and reliable, however, no responsibility is assumed by Genave for its use, nor infringements of patents or other rights of third parties resulting from its use. No license is granted under any patents or patent rights of Genave/NRC, Inc., its licensors or suppliers. Life Support Policy: Genave/NRC, Inc. products are not authorized for use as critical components in life support devices or systems without the express written approval of the president of Genave/NRC, Inc. As used herein: 1) Life support devices or systems are devices or systems which, (a) are intended for surgical implants into the body, or (b) support or sustain life, or whose failure to perform, when properly used in accordance with instructions, can reasonably be expected to result in a significant injury to the user. 2) Critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. CSP, Communications Signal Processor, Genave Operating System, GOS, CSP-105, CSP-107, CSP-108, CSP-120, RXC-3000 and RXCPro are Trademarks of Genave/NRC, Inc. The Genave name and logo are Registered trademarks of Genave/NRC, Inc. Touch- Other names used in this manual are trademarks of their respective companies. 9000-0000-115 Revision 1 4 of 14 Genave Electronics

Emergency Response Trailer Trailering... 7 Hitch Type... 7 Trailer Lights... 7 Safety Chains... 7 License Plate... 7 Setup and Deployment... 8 Site Selection... 8 Power Lines... 8 Wheel Chock Deployment... 8 Disconnecting the towing vehicle... 8 Safety Ensure Siren Control Power is Off... 8 Stabilizers Leveling... 8 Mast and System Deployment... 9 Safety Maximum Wind Speeds... 9 Remove Control Pendant... 9 Extending the Mast... 9 Applying AC power... 9 Take Down and Stowing... 10 Safety Maximum Wind Speeds... 10 Retracting the Mast... 10 Safety Turn Off Control Power... 10 Rotate Dolly Wheel... 10 Return Jacks... 10 Return Wheel Chocks... 10 System Power... 11 Batteries... 11 Solar... 11 AC... 11 Trailer Maintenance... 12 Tire Pressure... 12 Tire Wear... 12 Bearings... 12 9000-0000-115 Revision 1 5 of 14 Genave Electronics

Coupler... 12 Lights... 12 Battery... 12 Take Down / Stowing Checklist... 13 Turn Off Controls... 13 Mast... 13 Trailer... 13 Setup / Deployment Checklist... 14 Safety... 14 Trailer... 14 Mast... 14 Turn on Controls... 14 9000-0000-115 Revision 1 6 of 14 Genave Electronics

Trailering Before attempting to move the ERT (Emergency Response Trailer), the siren must be lowered and all equipment must be properly stowed. Hitch Type The ERT has a standard 2 inch receiver coupler. The coupler is a quick connect 2 inch. It may also be changed to Lunette or NATO ring. Trailer Lights The trailer light plug is a standard 4 pin connector. All of the trailer lights are LED style and sealed. Safety Chains The trailer is equipped with two standard safety chains. Be sure to cross them before connecting to the vehicle. License Plate The unit comes equipped with holes located in the middle of the rear body plate that align to the holes on a standard license plate. A license plate illumination light is also supplied for this purpose. 9000-0000-115 Revision 1 7 of 14 Genave Electronics

Setup and Deployment Site Selection Select a firm, level site without any overhead obstructions. Position the trailer so that the solar array gets a full view of the Southern sky. Power Lines The trailer must be positioned at least thirty (30) feet away from any overhead power lines. Wheel Chock Deployment Remove the wheel chocks from their trailer position and place firmly on each side of the tire for all tires. Disconnecting the towing vehicle The tow vehicle must be disconnected from the hitch when deploying. The outrigger jacks and tongue are not designed to lift the tow vehicle. Safety Ensure Siren Control Power is Off Before performing any work around the siren, open the control compartment verify the main power switch off. Verify the unit is off by opening the control cabinet and visually checking that the master switch is in the OFF position. Stabilizers Leveling Once disconnected from the tow vehicle, use the tongue jack to initially level the trailer. Next, after removing the locking pins, proceed to remove the stabilizers from their trailering location. Connect the leg to the jack before connecting the leg to the body. Insert the locking and securing pins and crank all 4 trailer jacks equally until each has a slight amount of weight so that they cannot be moved. Finally, crank the tongue jack until it no longer touches the ground. Place a spirit level on the body and adjust the four stabilizers on the trailer until the body is level in all directions. 9000-0000-115 Revision 1 8 of 14 Genave Electronics

Mast and System Deployment Safety Maximum Wind Speeds Do not attempt to extend the mast in winds above 35 mph. WIND MPH MAX 35 Remove Control Pendant The control for raising and lowering the mast is housed in the control cabinet. The mast cannot be raised or lowered without the main power switch in the ON position. Practice caution when turning on the master switch as this also turns on the power to the control board, amplifiers and the siren could activate. Extending the Mast The control pendant has a long enough cable so you can stand clear of the trailer while extending the mast. As the mast is extending, monitor the mast and cables for any snags. Stop the extension at once if there are any problems or entanglements. The mast has an upper limit control and will automatically stop when it is at the maximum height. Applying AC power The ERT can be plugged into 110 volt, 60 Hz power to charge its batteries. The batteries are always connected to the solar chargers as well as the AC chargers. The system will automatically charge the batteries from either the solar cells or from the AC charger. The plug-in is located on the right-hand side of the rear of the body. Equipment Ground 9000-0000-115 Revision 1 9 of 14 Genave Electronics

Take Down and Stowing Safety Maximum Wind Speeds Do not attempt to retract the mast in winds above 35 mph. WIND MPH MAX 35 Retracting the Mast As the mast is retracting, monitor the mast and cables for any snags. Stop the retraction at once if there are any problems or entanglements. When fully retracted, the mast nests completely into each previous section. The mast is a gravity retract only, and does not use power to retract. Safety Turn Off Control Power Turn off main switch and return pendant to its location within the control cabinet. Rotate Dolly Wheel Rotate dolly wheel to the vertical position and crank the dolly wheel down until it has some weight placed on it. Return Jacks Lower each leg and jack then unpin and return jack to their transport position at the front of the trailer. Make certain that the securing pins are reinstalled before moving the trailer. If the unit is equipped with handle bungies, install them before transporting trailer. Return Wheel Chocks Remove wheel chocks and store them in their transport location. 9000-0000-115 Revision 1 10 of 14 Genave Electronics

System Power Batteries One high quality battery supply power to all the computer boards, radio equipment, amplifier system, mast winch and all the other components on the ERT. They are charged by either the solar or AC power, depending which source has the higher charge voltage. The battery power will last up to (3) three days without a charging source. The battery is a type 4D marine. Solar A solar panel can supply the necessary power to recharge the batteries and run the ERT. The solar array must be facing the optimum sun position. The ERT requires an unobstructed view of the Southern sky. The panel is large enough to charge the batteries in Northern latitudes in winter. If the sun is obstructed from the panel, you must plug the ERT into an AC power source. AC The AC power connection located on the side of the body accepts a standard extension cord with 110 to 120 volt, 60 Hz AC power. The battery is charged from the AC source whenever it is available. There are no switches or jumpers necessary to move when connecting or disconnecting the AC power. The ERT system automatically makes the transfer between AC and solar power. 9000-0000-115 Revision 1 11 of 14 Genave Electronics

Trailer Maintenance Tire Pressure Check tire pressure before traveling with trailer. Tire Wear Change tires if there is 3/32 or less tread remaining. Bearings Lubricate the bearings every 1000 miles of travel. The trailer has Zerk fittings on each hub for this purpose. Use only wheel bearing grease. Coupler Check for wear of the coupler before each trip or every 1000 miles. Lights Check lights before each trip. Battery Load test the battery once per year. 9000-0000-115 Revision 1 12 of 14 Genave Electronics

Take Down / Stowing Checklist Turn Off Controls Power switch in battery cabinet turned ON. Power status visually verified in control cabinet. Mast Winds below 35 mph. No overhead obstructions. Mast fully retracted. Pendant returned to cabinet. Power switch turned OFF. Trailer Jacks and outriggers returned to transport location. Outrigger securing pins installed. Tongue hinge pin and locking pin installed. Chocks secured. Trailer lights checked. Coupler checked. Chains checked. All items on trailer secured. All debris removed. 9000-0000-115 Revision 1 13 of 14 Genave Electronics

Setup / Deployment Checklist Safety Power switch in battery cabinet is turned ON. Power off status visually verified in control cabinet. Trailer Firm level ground. Face solar panels South. Wheels chocked. All stabilizers extended, jacked down and pinned. Trailer is level. Mast Winds below 35 mph. No overhead obstructions. 30ft away from power lines. Speaker covers removed. Final leveling completed. Mast fully extended. Turn on Controls Hearing and safety protection. Power status visually verified in control cabinet. Low power Chirp test, optional. High power Chirp test, optional. Chirp test from remote wireless switch, optional. 9000-0000-115 Revision 1 14 of 14 Genave Electronics