INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03

Similar documents
INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00

INSTRUCTION MANUAL Oil level with pointer indicator

INSTRUCTION MANUAL CRS Combined insulation bushing

Shanghai Huaming Power Equipment Co.,Ltd.

On-Load Tap-Changer OILTAP MS

Pressure Relief Device Comem PRD Order sheet

On-Load Tap-Changer Type V

1ZSE en, Rev. 4. On-load tap-changers, type UC User s manual

On-Load Tap-Changer Type CM Operating Instructions

ABB SpA COMEM Operating Unit Power Grids Division Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

Transformer bushings, type GOH. Technical guide

Operating instructions Solenoid interlock EX-AZM About this document. Content

Angle seat valve with piston actuator VZXA-...-K

Assembly instructions

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

USE AND INSTALLATION HANDBOOK

Buchholz Relay MBP Gas and Oil Actuated Relay

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

TIDALFLUX 2300 F Quick Start

VERSAFLOW MAG 4000 Quick Start

PISTON ACCUMULATOR. Installation and operation manual Revision

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

LV Capacitor CLMD03 Power Module Instruction manual

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

Transformer Protection Relay MCHD

On-load tap-changer OILTAP V

Transformer bushings, type GOA 250. Installation and maintenance guide

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

Read and understand this manual for safely usage.

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

On-load tap-changers, types UCG, UCL, UCC and UCD with motor-drive mechanisms, types BUE and BUL Spare Parts List

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

RF Point Level Control with Sensor Monitor

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

OPTIFLUX 2000 Quick Start

Electrical network protection VIP30, VIP35. User s manual 12/2008

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

OFFICINE OROBICHE S.p.A. 1/7 INSTRUCTION MANUAL FOR FLOW SWITCHES PL SERIES

PIX-H Metal-clad switchgear up to 17.5kV

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

Test report. Type VRLTC load tap changer VRLTC 1500A Type test summary report

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

WATERFLUX 3070 Quick Start

Electrobar Elite. Instruction Manual. Conductor Bar System. ELITE-03A October 2011 Part Number: R3 Copyright 2011 Electromotive Systems

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

DIGITAL RCD(ELCB) TESTER

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

UniGear. Technical Guide

Oil-free piston compressors KK and piston vacuum pumps KV

User Manual Rittal PMC UPS 6kVA

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

SMC BATTERY CHARGER USER S MANUAL SMC USER S MANUAL

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Type 6213 EV, 6281 EV

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

GAS ACTUATED RELAYS FOR OIL FILLED TRANSFORMERS EN

Solenoid Valve DF-SA-series

Bowl feeder WV401-1 / Translation of operating and installation instructions

TGI Vacuum Circuit-Breaker Air isolator Earthing switch

Installation manual portable distributors

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

MODVAR Low voltage reactive power compensation modules Installation manual

1. Safety practices General Introduction Standards...3

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

ROM Series. Keeping the World Flowing. Installation Manual. Valve Actuators

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

Angle seat valve with diaphragm actuator VZXA-...-M

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

B kv T&D GAS INSULATED SWITCHGEAR

OPERATING INSTRUCTION

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

Angle seat valve with piston actuator VZXA-...-K

VQ400M SERIES CLASS A COMBINATION VALVES INSTRUCTION SHEET APPLICATION

Assembly and operating Instructions. Bypass Flow Meter DST

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

TECHNICAL DATA TYPE WDG/WLG/WSG OFF- CIRCUIT TAP CHANGER

Transcription:

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR469000 OR25 REV03 I

II

CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 RELAY FOR ON LOAD TAP CHANGER OR-25 2.1 Drawing 3 2.2 Operating principle 4 2.3 Technical features 4 2.4 Tests 4 3 INSTALLATION 3.1 Assembly 5 3.2 Mechanical test 5 3.3 Electrical connection 6 4 CONNECTION 4.1 Electrical contacts layout 6 5 OPERATION AND MAINTENANCE 5.1 Maintenance 7 5.2 Storage 7 0

1

1. Safety 1.1 Safety instructions Make sure that any personnel installing and operating the relay for OLTC OR-25 : Are technically qualified and competent Fully comply with these assembling instructions Improper operations or misuse could cause danger to: Life and limb To the equipment and other assets of the operator To the proper function of the equipment Safety instructions in this manual are shown in three different forms to emphasize important information. WARNING This information indicates particular danger to life and health. Disregarding such a warning can lead to serious or fatal injury CAUTION This information indicates particular danger to equipment or other property of the user. Serious or fatal injury cannot be excluded. NOTE This note gives important or specific information concerning the equipment. 1.2 Specified applications The relay for OLTC is used to protect the on-load tap-changer and the transformer when a malfunction occurs in the diverter switch or selector switch oil compartment. It is important to observe the limit values indicated on the nameplate and in the operating instruction before commissioning the device. 1.3 Safety notes on the equipment operation Electrical installation is subject to the relevant national safety rules. It is mandatory for safety reasons to connect the grounding cable. CAUTION Installation, electrical connection and fitting the device may only be carried out by qualified personnel and only in accordance to this instruction manual. It is the responsibility of the user to make sure that the device is used for the specified application only. For safety matters, please avoid any unauthorized and improper usage. WARNING All relevant fire protection regulations must be strictly followed 2

2. RELAY FOR ON LOAD TAP CHANGER TYPE OR-25 2.1 Drawing In figure 1, the external dimensions are provided for the relay type OR-25: Fig.1 C B A E F D 3

2.2 Operating principle Fig.2 The relay for OLTC application is positioned in the pipe work between the on-load tap-changer head and the oil conservator. This relay responds only if oil flow occurs from the on-load tap-changer head to the oil conservator. If this happens, the flow vane (2/D) which has 2 magnets (2/E) switches the reed (2/F). The circuit breakers are tripped and the transformer is de-energized. The housing (2/A) consists of powder painted or treated aluminum parts and is provided with flanges for the connection to the on-load tap-changer head pipe and the oil conservator pipe. The terminals of the reed switches are positioned in the terminal box (2/B) and sealing is guaranteed by an OR gasket. The terminal box is ventilated by a breather with IP grade 65/68. The terminal box cover is fixed to the terminal box with 4 screws (2/C). 2.3 Technical features General data Overall dimension See chapter 2.1 Material Ambient temperature All the external part are resistant to transformer oils, salt fog and UV rays -40 to80 C Oil temperature -40 to115 C Degree of protection Weight Oil flow speed (oil temperature 20 C) Switch electrical data (according to EN50126-1/2) IP65 in accordance with EN60529 ~3 Kg 0.70 ± 0.15 m/s 1.00 ± 0.15 m/s 1.50 ± 0.20 m/s 3.00 ± 0.40 m/s Breaking capacity Voltage Current Breaking capacity Dielectric strength of contacts 24 d.c. to 220 V d.c. 2 A for 1000 maneuvers 250 W L/R<40 ms 230 V a.c. 2 A for 1000 maneuvers 400 VA cos>0.5 Short duration power frequency withstand voltage 1 min kv (r.m.s.) Lightning impulse withstand voltage kv (peak) Between circuits and earth 2 4 Between contacts in open positions 1 3 2.4 Tests Type test: Relevant Standard: Routine test Relevant Standard: Vibration test EN 60137-3-4 EN 60068-3-3 Oil leakage test in hot oil (90 C for 30 minutes at 100kPa) EN 50216-2 Vacuum test (2.5 kpa for 24 hours) EN 50216-2 Operation test Leakage test (250 kpa for 2 minutes at 100 C) EN 50216-2 Mechanical test EN 50216-2 Salt fog test (500 hours) UNI EN ISO 9227 Flow vane test EN 50216-2 Degree of protection IP65 EN 60529 Dielectric test EN 50216-2 4

3. INSTALLATION 3.1 Assembly Install the relay in the pipe leading from the on-load tap-changer head to oil conservator (located as near as possible to the on-load tapchanger). Install the relay in a horizontal position and the test button upwards. The red arrow on the relay must point towards the conservator. Use a pipe of at least 25 mm nominal diameter between the relay and the on-load tap-changer / oil conservator. Install the relay well supported and protected against vibrations in this pipe connection. Between the relay flanges and pipe flanges, install the plane gasket that can be found in the box for the device. NOTE The pipe from the relay to the oil conservator must be placed with an inclination to ensure free escape of switching gas. COMEM recommends an angle of 2.5 degree from horizontal (at maximum 5 degree). Provide a stop valve between relay and oil conservator. NOTE Install the relay in a location where the influence of magnetic fields is felt as little as possible. After the installation check the function of the relay. The trip contacts can be tested manually moving the rod (mechanical test chapter 3.2). 3.2 Mechanical test Unscrew the plug (Fig.3/A) then slowly push the upper button (Fig.3/B) following the red arrow direction (figure below). In this way the internal mechanism is moved and the magnets switch the trip reeds. The button, after being released, will automatically come back to the original position as well as the internal components. This test does not provide the conformity of the electrical scheme. After the flow vane operation, the re-arming is manual pushing the upper button. D C B A 5 Fig.3

3.3 Electrical connection The reed switch of the relay can either be provided as NO, NC or CHANGE OVER contacts. The various types of contact combinations are available in chapter 4.1. CAUTION Connect the relay into the tripping circuit of the circuit breakers for the transformer so it is protected and immediately disconnected by the circuit breakers when the relay of the transformer is tripped. Remove the terminal box cover (3/C) un-screwing the four M5 screws (3/D). Feed the wire through the cable gland M20x1.5 (standard solution). Other cable glands are available, for further information contact COMEM. The cable gland M20x1.5 is adequate for leads with an outside diameter of 8 to 14 mm. Connect the leads (terminal bolts M6, max torque 2 Nm) following the electrical scheme shown on the label under the terminal box cover. Connect the protective conductor to the ground screw M4 in the terminal box (max torque: 5 Nm). Fix the terminal box cover on the terminal box. During this step check the terminal box cover gasket, the surface must be clean. The relay responds to oil flow, not gas accumulated. It is not necessary to discharge air from the relay when filling oil into the transformer tank. Gas accumulation in this type of relay is normal. WARNING Potential exposed gases collect in the relay while the on-load tap-changer is in operation. When you open the relay, make sure that there are not open fires or spark near it. Otherwise a danger of explosion exists. A period of time must pass before beginning further work on the relay so that the gases have time to volatilize. 4. CONNECTION 4.1 Electrical contacts layout Diagram AO: 1-2 (NO contact) Diagram LO: 1-2-3 (CHANGE OVER contact) Diagram GO: 1-2 (NO contact), 3-4 (NO contact) Diagram VO: 1-2 (NC contact), 3-4 (NC contact) Diagram RO: 1-2 (NC contact), 3-4 (NO contact) Diagram CO: 1-2-C1 (CHANGE OVER contact), 3-4-C2 (CHANGE OVER contact) Diagram LO: 1-2-3 (CHANGE OVER contact) Diagram SO: 1-2 (NO contact), 3-4 (NO contact), C1-C2 (NO contact) 6

5. Maintenance 5.1 Maintenance During regular checking of the transformer, we recommend performing the following checks on the relay for on-load tap changers: Check the exterior condition of the device To verify the contacts function following the chapter 3.2 (Mechanical test) Check the gaskets condition and if any leakage exists 5.2 Movement, transport and storage The OR25 for OLTC storage must remain in the original packaging and in a dry place with temperature range between -10 C to 40 C. Upon receiving the OR25, please check: The outer surface of the packaging to check that it is intact That there are no breakages to the packaging If damages are found, please contact COMEM, providing the data given on the shipping list and the serial number of the OR25 for OLTC. 7

8

Strada Regionale 11, Signolo 22 36054 Montebello Vic.No (VI) - Italy Tel. +39 0444 449311 - Fax -39 0444 449352 440359 http://www.comem.com e-mail:comem@comem.com 9